Anirban Das
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anirban Das has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Chao-Sung Lai
Department of Electronic Engineering, Chang Gung University, Taoyuan City, Taiwan, ROC; Department of Materials Engineering, Ming-Chi University of Technology, New Taipei City, Taiwan, ROC; Department of Nephrology, Chang Gung Memorial Hospital, Taoyuan City, Taiwan, ROC; Research Center for Intelligent Sensor Device, Institute of Pioneer Semiconductor Innovation, National Yang Ming Chiao Tung University, Hsinchu City, Taiwan, ROC
8 shared publications - Chia-Ming Yang
Department of Electronic Engineering, Institute of Electro-Optical Engineering, Chang-Gung University, Taoyuan City, Taiwan (R.O.C.)
5 shared publications - Steffi Krause
School of Engineering and Materials Science, Queen Mary University of London, Mile End Road, London E1 4NS, U.K.
5 shared publications - Bo Zhou
Imperial College London
4 shared publications Tsung-Cheng Chen
4 shared publications- De-Wen Zhang
Xi’an Jiaotong University
2 shared publications
Latest Publications
- Open Access
Photoelectrochemical imaging of action potentials for single cardiomyocytes through contact force manipulation of organoids
Accurate monitoring of cardiomyocyte action potentials (APs) is essential to understand disease propagation and for trials of novel therapeutics. Patch clamp techniques offer ‘gold standard’ measurements in this field, but are notoriously difficult to operate and only provide measurements of a single cell. Here we propose photoelectrochemical imaging (PEI), in conjunction with a setup for controlling the contact force between the cardiomyocyte organoids and the sensor surface, for measuring APs with high sensitivity. The method was validated through the use of drugs, and the results successfully visualized the expected electrophysiological changes to the APs. PEI allows for several cells to be monitored simultaneously, opening further research to the electrophysiological interactions of adjoining cells. This method expands the applications of PEI to three-dimensional geometries and provides the fields of stem cell research, drug trials and heart disease modelling with an invaluable tool to further investigate the role of APs.
Open AccessPhotoelectrochemical imaging of action potentials for single cardiomyocytes through contact force manipulation of organoids
Accurate monitoring of cardiomyocyte action potentials (APs) is essential to understand disease propagation and for trials of novel therapeutics. Patch clamp techniques offer ‘gold standard’ measurements in this field, but are notoriously difficult to operate and only provide measurements of a single cell. Here we propose photoelectrochemical imaging (PEI), in conjunction with a setup for controlling the contact force between the cardiomyocyte organoids and the sensor surface, for measuring APs with high sensitivity. The method was validated through the use of drugs, and the results successfully visualized the expected electrophysiological changes to the APs. PEI allows for several cells to be monitored simultaneously, opening further research to the electrophysiological interactions of adjoining cells. This method expands the applications of PEI to three-dimensional geometries and provides the fields of stem cell research, drug trials and heart disease modelling with an invaluable tool to further investigate the role of APs.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Hematite Nanorods as a Platform for Photoelectrochemical Imaging and Sensing
A photoelectrochemical imaging system (PEIS) using α-Fe 2 O 3 (hematite) thin films as the sensor substrate has been demonstrated for mapping the dynamic responses of multiple independent cells simultaneously. Herein, one-dimensional (1D) hematite nanorods (NRs) synthesized via a simple hydrothermal method are proposed as a platform for PEIS with enhanced photocurrent responses, good stability and excellent spatial resolution for applications requiring concurrent imaging of live cells and ion sensing applications. The photoelectrochemical sensing capability of hematite NRs was demonstrated by recording live cell images and by a high pH sensitivity without any surface modification. In contrast to potentiometric field-effect sensors based on silicon substrates, the deposition of a ion-sensitive PVC membrane on the highly structured hematite surface resulted in enhanced adhesion and an amperometric response to calcium ions (Ca 2+ ).
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessHematite Nanorods as a Platform for Photoelectrochemical Imaging and Sensing
A photoelectrochemical imaging system (PEIS) using α-Fe 2 O 3 (hematite) thin films as the sensor substrate has been demonstrated for mapping the dynamic responses of multiple independent cells simultaneously. Herein, one-dimensional (1D) hematite nanorods (NRs) synthesized via a simple hydrothermal method are proposed as a platform for PEIS with enhanced photocurrent responses, good stability and excellent spatial resolution for applications requiring concurrent imaging of live cells and ion sensing applications. The photoelectrochemical sensing capability of hematite NRs was demonstrated by recording live cell images and by a high pH sensitivity without any surface modification. In contrast to potentiometric field-effect sensors based on silicon substrates, the deposition of a ion-sensitive PVC membrane on the highly structured hematite surface resulted in enhanced adhesion and an amperometric response to calcium ions (Ca 2+ ).
- 28 October 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (11) , 3568-3575
Ammonia Gas Sensor Response of a Vertical Zinc Oxide Nanorod-Gold Junction Diode at Room Temperature
Conventional metal oxide semiconductor (MOS) gas sensors have been investigated for decades to protect our life and property. However, the traditional devices can hardly fulfill the requirements of our fast developing mobile society, because the high operating temperatures greatly limit their applications in battery-loaded portable systems that can only drive devices with low power consumption. As ammonia is gaining importance in the production and storage of hydrogen, there is an increasing demand for energy-efficient ammonia detectors. Hence, in this work, a Schottky diode resulting from the contact between zinc oxide nanorods and gold is designed to detect gaseous ammonia at room temperature with a power consumption of 625 μW. The Schottky diode gas sensors benefit from the change of barrier height in different gases as well as the catalytic effect of gold nanoparticles. This diode structure, fabricated without expensive interdigitated electrodes and displaying excellent performance at room temperature, provides a novel method to equip mobile devices with MOS gas sensors.
- 28 October 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (11) , 3568-3575
Ammonia Gas Sensor Response of a Vertical Zinc Oxide Nanorod-Gold Junction Diode at Room Temperature
Conventional metal oxide semiconductor (MOS) gas sensors have been investigated for decades to protect our life and property. However, the traditional devices can hardly fulfill the requirements of our fast developing mobile society, because the high operating temperatures greatly limit their applications in battery-loaded portable systems that can only drive devices with low power consumption. As ammonia is gaining importance in the production and storage of hydrogen, there is an increasing demand for energy-efficient ammonia detectors. Hence, in this work, a Schottky diode resulting from the contact between zinc oxide nanorods and gold is designed to detect gaseous ammonia at room temperature with a power consumption of 625 μW. The Schottky diode gas sensors benefit from the change of barrier height in different gases as well as the catalytic effect of gold nanoparticles. This diode structure, fabricated without expensive interdigitated electrodes and displaying excellent performance at room temperature, provides a novel method to equip mobile devices with MOS gas sensors.
- Open Access
InGaN as a Substrate for AC Photoelectrochemical Imaging
AC photoelectrochemical imaging at electrolyte–semiconductor interfaces provides spatially resolved information such as surface potentials, ion concentrations and electrical impedance. In this work, thin films of InGaN/GaN were used successfully for AC photoelectrochemical imaging, and experimentally shown to generate a considerable photocurrent under illumination with a 405 nm modulated diode laser at comparatively high frequencies and low applied DC potentials, making this a promising substrate for bioimaging applications. Linear sweep voltammetry showed negligible dark currents. The imaging capabilities of the sensor substrate were demonstrated with a model system and showed a lateral resolution of 7 microns.
Open AccessInGaN as a Substrate for AC Photoelectrochemical Imaging
AC photoelectrochemical imaging at electrolyte–semiconductor interfaces provides spatially resolved information such as surface potentials, ion concentrations and electrical impedance. In this work, thin films of InGaN/GaN were used successfully for AC photoelectrochemical imaging, and experimentally shown to generate a considerable photocurrent under illumination with a 405 nm modulated diode laser at comparatively high frequencies and low applied DC potentials, making this a promising substrate for bioimaging applications. Linear sweep voltammetry showed negligible dark currents. The imaging capabilities of the sensor substrate were demonstrated with a model system and showed a lateral resolution of 7 microns.
- Open Access
- 15 April 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (9) , 5896-5903
Photoelectrochemical Imaging System for the Mapping of Cell Surface Charges
The surface charge of cells affects cell signaling, cell metabolic processes, adherence to surfaces and cell proliferation. Our understanding of the role of membrane charges is limited due to the inability to observe changes without interfering, chemically or physically, with the cell or its membrane. Here, we report that a photoelectrochemical imaging system (PEIS) based on label-free ac-photocurrent measurements at indium tin oxide (ITO) coated glass substrates can be used to map the basal surface charge of single live cells under physiological conditions. Cells were cultured on the ITO substrate. Photocurrent images were generated by scanning a focused, modulated laser beam across the back of the ITO coated glass substrate under an applied bias voltage. The photocurrent was shown to be sensitive to the negative surface charge of the substrate facing, basal side of a single living cell – an area not accessible to other electrochemical or electrophysiological imaging techniques. The PEIS was used to monitor the lysis of mesenchymal stem cells.
- 15 April 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (9) , 5896-5903
Open AccessPhotoelectrochemical Imaging System for the Mapping of Cell Surface Charges
The surface charge of cells affects cell signaling, cell metabolic processes, adherence to surfaces and cell proliferation. Our understanding of the role of membrane charges is limited due to the inability to observe changes without interfering, chemically or physically, with the cell or its membrane. Here, we report that a photoelectrochemical imaging system (PEIS) based on label-free ac-photocurrent measurements at indium tin oxide (ITO) coated glass substrates can be used to map the basal surface charge of single live cells under physiological conditions. Cells were cultured on the ITO substrate. Photocurrent images were generated by scanning a focused, modulated laser beam across the back of the ITO coated glass substrate under an applied bias voltage. The photocurrent was shown to be sensitive to the negative surface charge of the substrate facing, basal side of a single living cell – an area not accessible to other electrochemical or electrophysiological imaging techniques. The PEIS was used to monitor the lysis of mesenchymal stem cells.
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 47, 1-3
High photocurrent and operation frequency for light-addressable potentiometric sensor by thinner Si substrate
LAPS with different thickness of P-type silicon wafers are first investigated for photocurrent, operation frequency of applied ac signal and pH sensing performance, respectively. A high dielectric constant material, niobium oxide (NbOx), was directly deposited as the sensing membrane by reactive radio frequency sputtering. pH sensitivity is around 60.3 mV/pH with linearity of 99.1%. Thin Si substrate has higher photovoltage, especially with high-frequency ac signal. With ac signal of 20kHz, photovoltage of 350 um Si shows comparable to 500 um Si. Even in frequency higher than 50 kHz, fast scanning speed could be achieved by analog mirror and red laser for chemical image sensor.
- 1 July 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 47, 1-3
High photocurrent and operation frequency for light-addressable potentiometric sensor by thinner Si substrate
LAPS with different thickness of P-type silicon wafers are first investigated for photocurrent, operation frequency of applied ac signal and pH sensing performance, respectively. A high dielectric constant material, niobium oxide (NbOx), was directly deposited as the sensing membrane by reactive radio frequency sputtering. pH sensitivity is around 60.3 mV/pH with linearity of 99.1%. Thin Si substrate has higher photovoltage, especially with high-frequency ac signal. With ac signal of 20kHz, photovoltage of 350 um Si shows comparable to 500 um Si. Even in frequency higher than 50 kHz, fast scanning speed could be achieved by analog mirror and red laser for chemical image sensor.
- 1 July 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 198, 225-232
A high-speed, flexible-scanning chemical imaging system using a light-addressable potentiometric sensor integrated with an analog micromirror
- 1 July 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 198, 225-232
A high-speed, flexible-scanning chemical imaging system using a light-addressable potentiometric sensor integrated with an analog micromirror
- 1 January 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 190, 664-672
Miniaturized amorphous-silicon based chemical imaging sensor system using a mini-projector as a simplified light-addressable scanning source
- 1 January 2014
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 190, 664-672
Miniaturized amorphous-silicon based chemical imaging sensor system using a mini-projector as a simplified light-addressable scanning source