KCKevin G. Cornwell

Kevin G. Cornwell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kevin G. Cornwell has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Local amiodarone delivery via an extracellular collagen matrix patch to reduce new-onset postoperative atrial fibrillation

    by Kevin G. Cornwell, Peter J. Jackson, Clayton A. Kaiser, Clementene S. Clayton, Gretel Monreal, Mark S. Slaughter, Niv Ad, Yiannis Monovoukas


  • Open Access

    Fundamentals of Extracellular Matrix Biomaterial Assimilation: Effect of Suture Type on Attachment Strength and Cell Repopulation

    by David M. MD Adelman, Kevin G. Cornwell

    Background: The clinical results with extracellular matrix biomaterials are confounded by expectations of material response based on years of experience with permanent or degradable synthetic polymers. However, the remodeling or assimilation of extracellular matrix biomaterials is dictated by cell-mediated processes rather than fibrous encapsulation or hydrolytic degradation. Previously, we found that tissue adherence and revascularization were dictated by proximity with de-epithelialized host tissue. We now investigate the effects of polymer and fixation type on attachment strength and rate of cell repopulation in an intra-abdominal implant model. Methods: An intra-abdominal implant model in rats was used to probe assimilation properties at 4 weeks and 12 weeks with permanent and degradable suture types as well a combination of suture and biologic attachment (mesothelial abrasion). The mechanical strength of the attachment was measured by peel testing and the repopulation by automated cell counting of histologic sections. Results: The intensity of the biologic response was greater with degradable polymers than permanent polypropylene. Tissue attachment strength ranged from 2 to 15 N but changed in elasticity with time. The magnitude and distribution of cell repopulation was highly variable by suture type but ultimately did not affect the long-term strength of the soft tissue attachment. Conclusions: The tissue approximating polymer sutures were stretchy and of similar strength regardless of degradation rate or polymer type. The strongest attachment, most rapid repopulation of the deep matrix regions, and most uniform distribution of cells were found with the addition of biologic attachment.


  • Clinically available reinforcing materials for soft tissue reconstruction

    by Kevin G Cornwell, Charles Bret Jessee, David M Adelman

    Navigating the rapidly evolving field of materials for soft tissue reinforcement is challenging given the volume of clinically available options. Additionally, the current generally accepted classifications of these mesh materials confound the understanding of their utility by grouping disparate materials that have attributes overlapping category boundaries and that do not fully consider their clinically functionality. This review article highlights, from a materials science perspective, the most important attributes of these materials to improve the clinical decision-making process in the selection of the most appropriate features and design for the patient, surgery and clinical need. These characteristics include the physical attributes that directly impact the surgical procedure and immediate postoperative mechanical requirements as well as the post-implantation properties such as an adequate reinforcement time, strength of the resulting tissue and infection risk profile.


  • Open Access

    Bioprosthetic Versus Synthetic Mesh: Analysis of Tissue Adherence and Revascularization in an Experimental Animal Model

    by David M. MD Adelman, Kevin G. Cornwell

    Background: Both synthetic and bioprosthetic meshes play important roles in surgical procedures such as ventral hernia repair. Although sometimes used interchangeably, these devices have inherently different properties. We therefore sought to better understand how these materials interact with the host environment to optimize surgical techniques and to improve outcomes. Methods: Synthetic mesh (polypropylene, Prolene) or bioprosthetic mesh (acellular fetal/neonatal bovine dermis, SurgiMend) was implanted intraperitoneally into rats lateral to a ventral incision in a novel intra-abdominal implant model. Two variables were modified with each material: (1) tight or loose tissue apposition, altered by modifying suture placement; and (2) abdominal wall injury, altered by selective abrasion of the peritoneal lining. After 5 weeks, the meshes and abdominal wall were evaluated grossly and histologically. The analysis focused on the degree of inflammatory response, neovascularization, and mesh adherence to the surrounding tissues. Results: Synthetic mesh adhered to the abdominal wall and visceral organs, regardless of the degree of apposition or tissue injury, due to a foreign body–mediated inflammatory reaction. In areas of noninjured peritoneal lining, SurgiMend was adherent peri-suture. Neovascularization entered the mesh from these apposition points and spread outward. In areas of denuded peritoneal lining, the adherent and vascularized areas were significantly greater and not merely coincident with suture placement. Conclusions: The inflammatory and wound healing responses with bioprosthetic mesh seem fundamentally different from synthetic mesh. Understanding these differences may lead to varied outcomes in adherence and vascularization of the materials, and ultimately the efficacy of hernia repair. Additionally, these differences highlight the need for further basic research to optimize mesh selection for surgical technique.


  • Enhanced Proliferation and Migration of Fibroblasts on the Surface of Fibroblast Growth Factor-2-Loaded Fibrin Microthreads

    by Kevin G. Cornwell, George D. Pins

    Fibrin microthreads are discrete biopolymer fibers, 50–100 μm in diameter, produced from the natural extracellular matrix protein of the provisional matrix that promotes tissue regeneration in the in vivo wound healing environment. The goals of this study were to investigate the feasibility of creating fibrin microthreads containing fibroblast growth factor-2 (FGF-2), and to study the potential of a fibrin matrix to bind signaling proteins known to promote wound healing and regulate cell function in localized cellular microenvironments on scaffold surfaces. FGF-2 was loaded into fibrin microthreads in concentrations ranging from 0 to 200 ng/mL, to investigate the effect of the material on fibroblast attachment, proliferation, cellular outgrowth, and alignment. Although FGF-2-loaded microthreads did not affect fibroblast attachment, they significantly increased cellular outgrowth and proliferation relative to unloaded microthreads. The most pronounced effects were observed at day 7 of cell culture. Further, all of the fibrin microthreads promoted the alignment of fibroblasts and their cytoskeletal components along the long axis of threads, independent of the FGF-2 concentration. Ultimately, we anticipate that these fibrin microthreads will be a promising biopolymer material to promote the regeneration of injured tissues because of their mechanical stability and their matrix signaling capabilities, particularly when loaded with matrix-bound growth factors such as FGF-2.


  • TissueMend™

    by Kenneth S James, Kevin C Cornwell, A Gerson Greenburg


  • Extracellular Matrix Biomaterials for Soft Tissue Repair

    by Kevin G. Cornwell, Adam Landsman, Kenneth S. James


  • Discrete crosslinked fibrin microthread scaffolds for tissue regeneration

    by Kevin G. Cornwell, George D. Pins

    In this study, we report on the development of discrete fibrin microthreads as well as novel scaffolds composed of arrays of fibrin threads. These scaffolds exhibit mechanical properties that are significantly greater than fibrin gels and cellular responses suggesting that the materials are conducive to the development of organized, aligned tissues. Fibrin microthreads were produced by coextruding solutions of 70 mg/mL fibrinogen and 6 U/mL thrombin through small diameter polyethylene tubing. Uncrosslinked fibrin microthreads averaged 55–65 μm in hydrated diameter and achieved ultimate tensile strengths approaching 4.5 MPa. The strengths and stiffnesses of the microthreads were approximately twofold greater when the materials were treated with exposure to ultraviolet (UV) light. Although UV crosslinking attenuated fibroblast proliferation, uncrosslinked fibrin microthreads supported fibroblast attachment, proliferation, and alignment, suggesting that they represent a viable biomaterial for the aligned regeneration of tissues. Because of the physiologic roles of fibrin matrices in the early phase of wound healing, we anticipate that these fibrin‐based microthreads will direct the spatially and temporally complex processes of cell‐mediated tissue ingrowth and regeneration. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2007


  • Crosslinking of discrete self‐assembled collagen threads: Effects on mechanical strength and cell–matrix interactions

    by Kevin G. Cornwell, Pedro Lei, Stelios T. Andreadis, George D. Pins

    Bundles of threads extruded from type I collagen have been researched extensively as scaffolds to promote the repair and regeneration of torn tendons and ligaments. The success of these scaffolds has been limited by insufficient tissue ingrowth from the wound margin, which may be inhibited by the chemical or physical crosslinking treatment used to increase the mechanical properties and decrease the degradation rate of these scaffolds. Recently, self‐assembled collagen threads extruded from solutions of type I collagen molecules were shown to possess ultimate tensile strengths and structural properties comparable to native tendon fibers; however the tissue response to these threads has yet to be determined. The goal of this study was to investigate the effects of various crosslinking techniques on the mechanical properties as well as the in vitro rate of new tissue ingrowth on these threads. Our findings indicate that the physical crosslinking techniques, dehydrothermal (DHT) or ultraviolet light (UV), most significantly improve the mechanical strengths of the threads, but most significantly decrease the rate of cell migration. In contrast, carbodiimide (EDC) crosslinking achieved sub‐optimal strength generation, but demonstrated improved cell migration rates. Future studies will investigate the design of threads with surface biochemistries that maximize tissue ingrowth while maintaining the mechanical stability of the scaffold. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2007