Farzin Arjmand
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Farzin Arjmand has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Olivier Monasson
CY Cergy Paris Université, CNRS, BioCIS, Cergy Pontoise, France
3 shared publicationsAlima Chali
Université Paris Cité, CNRS, ITODYS (UMR-7086), Paris, France
2 shared publicationsElisa Peroni
CY Cergy Paris Université, CNRS, BioCIS, Cergy Pontoise, France
2 shared publicationsGuy Dirras
Université Sorbonne Paris Nord, CNRS, LSPM, Villetaneuse, France
2 shared publicationsLefu Zhang
School of Nuclear Science and Engineering, School of Mechanical Engineering, Shanghai Jiao Tong University, No. 800 Dongchuan Road, Shanghai 200240, PR China
2 shared publicationsLoïc Perrière
Université Paris-Est Créteil, CNRS, ICMPE, Thiais, France
2 shared publications
Latest Publications
- 28 July 2025
- Published by SAGE Publications in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
- Vol. 61 (5) , 670-681
Corrosion inhibition by grafted nitrophenyl and BMP-2 peptide derivatives on a Ti 35 Zr 25 Nb 25 (MoTa) 15 high-entropy alloy
Nitrophenyl layers of varying thicknesses were grafted onto an arc-melted Ti 35 Zr 25 Nb 25 (MoTa) 15 high-entropy alloy via electrochemical reduction of 4-nitrobenzenediazonium tetrafluoroborate. A fluorescent peptide derived from bone morphogenetic protein 2 (BMP-2) was then covalently tethered to these films. Electrochemical corrosion behaviour was assessed in 0.1 M NaCl by potentiodynamic polarisation and electrochemical impedance spectroscopy. Grafted nitrophenyl films reduced the corrosion current density ( I corr ) by more than 10-fold and diminished anodic current densities by over 1550-fold, while shifting the corrosion potential ( E corr ) to more positive values. Subsequent BMP-2 coupling further increased the resistive impedance of the coating and eliminated diffusion-limited (Warburg) behaviour. These results demonstrate that, for the Ti 35 Zr 25 Nb 25 (MoTa) 15 alloy in chloride media, sequential nitrophenyl grafting and peptide immobilisation yield a robust, corrosion-resistant and biofunctional surface.
- 28 July 2025
- Published by SAGE Publications in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
- Vol. 61 (5) , 670-681
Corrosion inhibition by grafted nitrophenyl and BMP-2 peptide derivatives on a Ti 35 Zr 25 Nb 25 (MoTa) 15 high-entropy alloy
Nitrophenyl layers of varying thicknesses were grafted onto an arc-melted Ti 35 Zr 25 Nb 25 (MoTa) 15 high-entropy alloy via electrochemical reduction of 4-nitrobenzenediazonium tetrafluoroborate. A fluorescent peptide derived from bone morphogenetic protein 2 (BMP-2) was then covalently tethered to these films. Electrochemical corrosion behaviour was assessed in 0.1 M NaCl by potentiodynamic polarisation and electrochemical impedance spectroscopy. Grafted nitrophenyl films reduced the corrosion current density ( I corr ) by more than 10-fold and diminished anodic current densities by over 1550-fold, while shifting the corrosion potential ( E corr ) to more positive values. Subsequent BMP-2 coupling further increased the resistive impedance of the coating and eliminated diffusion-limited (Warburg) behaviour. These results demonstrate that, for the Ti 35 Zr 25 Nb 25 (MoTa) 15 alloy in chloride media, sequential nitrophenyl grafting and peptide immobilisation yield a robust, corrosion-resistant and biofunctional surface.
- 16 December 2024
- Published by Springer Nature in Emergent Materials
- Vol. 8 (1) , 537-559
In-situ chemical grafting of aminophenyl and RGD peptide on an equimolar high-entropy HfNbTaTiZr alloy: electrochemical behavior and surface characterization
- 16 December 2024
- Published by Springer Nature in Emergent Materials
- Vol. 8 (1) , 537-559
In-situ chemical grafting of aminophenyl and RGD peptide on an equimolar high-entropy HfNbTaTiZr alloy: electrochemical behavior and surface characterization
- 22 July 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (4)
L-PBF processing and characterization of a Ti35Nb30Zr29Mo3Ta3 multiprincipal element alloy for medical implants
This Letter reports on the processing, mechanical properties, electrochemical performance, and toxicity behavior of a multiprincipal element Ti35Nb30Zr29Mo3Ta3 alloy. The recovered centimeter-sized cubes or parallelepipeds were polished before analysis. It was found that the homogeneity and yield stress of the alloys get increased when higher volumetric energy densities are applied during processing. The synthesized alloys also exhibited a Young modulus closer to those of bones than those usually reported on the conventional orthopedic metals (60–80 GPa for this alloy against 110 and 4–30 GPa for the Ti-6Al-4V and bone, respectively). The electrochemical corrosion assays performed at 25 and 37 °C, in sodium chloride (NaCl, 0.1 M), deoxygenated high glucose Dulbecco's Modified Eagle Medium (DMEM), and deoxygenated DMEM implemented with fetal bovine serum showed corrosion potentials (Ecorr) ranged in the order NaCl(25 °C) ≈ DMEM + PBS(37 °C) > DMEM(37 °C) and impedances much larger in the DMEM and DMEM + PBS media than in NaCl. Finally, pre-osteoblasts cells cultured in the medium conditioned by the alloy did not evidence cytotoxicity effect, because no effects on the cell proliferation and morphology were observed. These data suggest the biocompatibility of this alloy, indicating no acute toxicity, which is a prerequisite for the integration of an alloy as a bioimplant.
- 22 July 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 125 (4)
L-PBF processing and characterization of a Ti35Nb30Zr29Mo3Ta3 multiprincipal element alloy for medical implants
This Letter reports on the processing, mechanical properties, electrochemical performance, and toxicity behavior of a multiprincipal element Ti35Nb30Zr29Mo3Ta3 alloy. The recovered centimeter-sized cubes or parallelepipeds were polished before analysis. It was found that the homogeneity and yield stress of the alloys get increased when higher volumetric energy densities are applied during processing. The synthesized alloys also exhibited a Young modulus closer to those of bones than those usually reported on the conventional orthopedic metals (60–80 GPa for this alloy against 110 and 4–30 GPa for the Ti-6Al-4V and bone, respectively). The electrochemical corrosion assays performed at 25 and 37 °C, in sodium chloride (NaCl, 0.1 M), deoxygenated high glucose Dulbecco's Modified Eagle Medium (DMEM), and deoxygenated DMEM implemented with fetal bovine serum showed corrosion potentials (Ecorr) ranged in the order NaCl(25 °C) ≈ DMEM + PBS(37 °C) > DMEM(37 °C) and impedances much larger in the DMEM and DMEM + PBS media than in NaCl. Finally, pre-osteoblasts cells cultured in the medium conditioned by the alloy did not evidence cytotoxicity effect, because no effects on the cell proliferation and morphology were observed. These data suggest the biocompatibility of this alloy, indicating no acute toxicity, which is a prerequisite for the integration of an alloy as a bioimplant.
- 4 February 2022
- Published by Elsevier in Corrosion Science
- Vol. 198, 110143
Hydrogen absorption in solution/mill annealed Alloy 600 at room temperature H2SO4 and high-temperature pressurized water
- 4 February 2022
- Published by Elsevier in Corrosion Science
- Vol. 198, 110143
Hydrogen absorption in solution/mill annealed Alloy 600 at room temperature H2SO4 and high-temperature pressurized water
- 12 April 2019
- Published by Wiley in Materials and Corrosion
- Vol. 70 (7) , 1179-1191
Water chemistry, solution resistivity, and oxygen reduction reaction in simulated primary coolant of pressurized water reactors
The effect of temperature (25 °C–300 °C) on the ohmic potential drop (ΔEΩ) and resistivity (Rsol) of a simulated primary coolant of the pressurized water reactors was investigated using electrochemical impedance spectroscopy (EIS) and galvanostatic potentiometry. The variations in the conductivity and pH of the solution showed that by increasing the temperature the magnitude of the Rsol and therefore ΔEΩ of the system first decreases rapidly (until ~150 °C) and then reaches a relatively stable plateau value. Increasing the pressure of the system decreased the magnitude of the Rsol in the oxygenated coolant. Investigation of the oxygen reduction reaction (ORR) on platinum (Pt), 316L stainless steel (SS), Alloy 690, and carbon steel revealed the great effect of water chemistry, in particular pH on the rate of the ORR on these materials. OH− adsorption on Pt reduced the rate of the ORR on this metal at temperatures higher than ~100 °C. Finally, it was found that higher H3O+ concentrations reduce the rate of the ORR on iron‐ and nickel‐based alloys, while increasing the OH− concentration at temperatures higher than ~150 °C accelerates the rate of the ORR on these alloys.
- 12 April 2019
- Published by Wiley in Materials and Corrosion
- Vol. 70 (7) , 1179-1191
Water chemistry, solution resistivity, and oxygen reduction reaction in simulated primary coolant of pressurized water reactors
The effect of temperature (25 °C–300 °C) on the ohmic potential drop (ΔEΩ) and resistivity (Rsol) of a simulated primary coolant of the pressurized water reactors was investigated using electrochemical impedance spectroscopy (EIS) and galvanostatic potentiometry. The variations in the conductivity and pH of the solution showed that by increasing the temperature the magnitude of the Rsol and therefore ΔEΩ of the system first decreases rapidly (until ~150 °C) and then reaches a relatively stable plateau value. Increasing the pressure of the system decreased the magnitude of the Rsol in the oxygenated coolant. Investigation of the oxygen reduction reaction (ORR) on platinum (Pt), 316L stainless steel (SS), Alloy 690, and carbon steel revealed the great effect of water chemistry, in particular pH on the rate of the ORR on these materials. OH− adsorption on Pt reduced the rate of the ORR on this metal at temperatures higher than ~100 °C. Finally, it was found that higher H3O+ concentrations reduce the rate of the ORR on iron‐ and nickel‐based alloys, while increasing the OH− concentration at temperatures higher than ~150 °C accelerates the rate of the ORR on these alloys.
- 25 February 2014
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 18 (7) , 1779-1788
Microcapillary electrochemical droplet cells: applications in solid-state surface analysis
- 25 February 2014
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 18 (7) , 1779-1788
Microcapillary electrochemical droplet cells: applications in solid-state surface analysis
- 27 November 2008
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 10 (3) , 247-252
Seroprevalence of human T lymphtropic virus (HTLV) among tissue donors in Iranian tissue bank
Iranian Tissue Bank prepares a wide range of human tissue homografts such as; heart valve, bone, skin, amniotic membrane and other tissues for different clinical applications. The purpose of this study was to determine the seroprevalence of HTLV in tissue donors. About 1,548 tissue donors were studied during a 5-years period by ELISA assays. HTLV1,2—antibodies were tested for all of donors with other tests upon American Association of Tissue Banks (AATB) standards. About 25 (1.61%) out of 1,548 tissue donors were HTLV positive that 17 donors were male and 8 were female (female/male ratio was approximately 47%). Regarding to the prevalence of HTLV among tissue donors and importance of cell and tissue safety and quality assurance, we recommend that all blood, cell and tissue banks should be involved both routine serological methods and other complementary tests such as polymerase chain reaction (PCR) for diagnosis of HTLV.
- 27 November 2008
- Published by Springer Nature in Cell and Tissue Banking
- Vol. 10 (3) , 247-252
Seroprevalence of human T lymphtropic virus (HTLV) among tissue donors in Iranian tissue bank
Iranian Tissue Bank prepares a wide range of human tissue homografts such as; heart valve, bone, skin, amniotic membrane and other tissues for different clinical applications. The purpose of this study was to determine the seroprevalence of HTLV in tissue donors. About 1,548 tissue donors were studied during a 5-years period by ELISA assays. HTLV1,2—antibodies were tested for all of donors with other tests upon American Association of Tissue Banks (AATB) standards. About 25 (1.61%) out of 1,548 tissue donors were HTLV positive that 17 donors were male and 8 were female (female/male ratio was approximately 47%). Regarding to the prevalence of HTLV among tissue donors and importance of cell and tissue safety and quality assurance, we recommend that all blood, cell and tissue banks should be involved both routine serological methods and other complementary tests such as polymerase chain reaction (PCR) for diagnosis of HTLV.