RCRiccardo Compagnoni

Riccardo Compagnoni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Riccardo Compagnoni has a total of 200 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The biplanar cut in medial closing‐wedge distal femoral osteotomy is associated with a four‐fold lower rate of lateral hinge fractures at non‐inferior coronal correction

    by Alessio Maione, Pierrenzo Pozzi, Simone Gallizzi, Matteo Davide Parmigiani, Simone Romano, Alessandra Menon, Filippo Calanna, Riccardo Compagnoni, Paolo Ferrua, Massimo Berruto, et al.

    Purpose: This study compares the outcomes of medial closing‐wedge distal femoral osteotomy (MCW‐DFO) performed with a monoplanar versus a biplanar technique, evaluating radiological correction as primary outcome and hinge fracture incidence, overall complication profile and patient‐reported outcome measures as secondary outcomes. Methods: A retrospective analysis was conducted on a consecutive series of 82 patients (86 knees) with genu valgum who underwent MCW‐DFO between 2010 and 2024. Patients were divided into a monoplanar group (44 knees) and a biplanar group (42 knees). Primary outcome was the evaluation of the hip–knee–ankle angle (HKA) and lateral distal femoral angle (LDFA), assessed on weight‐bearing full‐length radiographs pre‐ and postoperatively. Secondary outcomes included hinge fracture incidence, overall complication rate and patient‐reported outcome measures (PROMs) comprising the International Knee Documentation Committee score, Knee Society Score, Knee Injury and Osteoarthritis Outcome Score, Tegner Activity Scale and Visual Analogue Scale for pain. Results: Both groups achieved equivalent and significant coronal correction, with no between‐group differences in postoperative HKA (180.1° ± 2.5° vs. 179.8° ± 4.4°, p = 0.502) or LDFA (90.7° ± 2.6° vs. 91.5° ± 4.1°, p = 0.339). Hinge fractures were significantly more frequent in the monoplanar group (75.0% vs. 19.0%, p < 0.001), and non‐inferiority of the biplanar technique was formally demonstrated for all radiographic parameters. All PROMs improved significantly from baseline in both groups, with the magnitude of improvement exceeding the minimal clinically important difference thresholds for all scores. Conclusions: Biplanar MCW‐DFO protocol was associated with a lower incidence of lateral hinge fractures than monoplanar procedure, while achieving comparable coronal correction, as formally confirmed by non‐inferiority testing. Although trends toward better activity level and pain relief were observed in the biplanar group, these differences did not retain statistical significance and should be considered hypothesis‐generating. These findings warrant prospective investigation of the biplanar technique as a potentially preferable approach for MCW‐DFO. Level of Evidence: Level III, case‐control study.

  • Open Access

    Needle Arthroscopy in Orthopedic Practice: Clinical Applications, Evidence Architecture, and Translational Gaps—A Scoping Review

    by Hubert Makowski, Piotr Łukowiak, Karolina Michno, Maciej Ciesielski, Jan Mianowski, Michał Maciejowski, Błażej Wójtowicz, Riccardo Compagnoni, Pietro Simone Randelli, Marcin Domżalski, et al.

    Background: Needle arthroscopy can alter not only portal size but also the diagnostic and treatment pathway by enabling direct visualization under local anesthesia and selected limited interventions. Its diffusion across joints, however, may be outpacing clinical validation. Methods: This PRISMA-ScR-guided review mapped PubMed/MEDLINE-indexed primary publications from database inception through 31 July 2026. The quantitative flow is therefore an auditable but incomplete evidence map rather than a complete census of the technology; studies indexed exclusively outside PubMed may have been missed. Backward reference-list screening was used as a completeness check, while earlier Scopus, Web of Science, and Cochrane histories were retained as sensitivity sources and not pooled into the quantitative flow. Two reviewers independently screened and charted records using a shared form. Reports were de-duplicated by PMID, DOI, and normalized title and characterized by anatomy, design, application, platform, outcomes, harms reporting, study-design hierarchy, and principal methodological limitation. Technical or cadaveric feasibility was analyzed separately from clinical and comparative evidence. Results: The final map comprised 105 unique primary publications: 49 technical, 41 clinical, and 15 cadaveric. Technical and cadaveric reports (64/105, 61.0%) outnumbered clinical reports (41/105, 39.0%), limiting estimation of clinical effectiveness. Ninety publications (85.7%) appeared from 2021 onward; the 2026 count is incomplete because the search ended on 31 July. For descriptive display across the complete map, nine reports (8.6%) were in Levels I–II and 93 (88.6%) in IV–V; among the 41 clinical reports, 29 (70.7%) were IV–V and 12 (29.3%) were I–III. NanoScope accounted for 87 of 107 platform mentions (81.3%). Diagnostic and second-look applications had the most consistent comparative rationale, but lesion-specific estimates varied by joint and reference standard. Reported harms were generally minor where surveillance was described, but rare-harm inference was limited by small samples and inconsistent adverse-event ascertainment. Conclusions: The field remains promising but unproven: technical breadth exceeds comparative clinical validation. Because the quantitative evidence map is PubMed/MEDLINE-only and dominated by technical, cadaveric, and IV–V reports, current evidence is insufficient to estimate clinical effectiveness or justify replacement of MRI or conventional arthroscopy. Needle arthroscopy should therefore be viewed as an indication-specific complement and a hypothesis-generating technology rather than a replacement platform. Multicentre comparative studies and randomized trials, where ethically and practically feasible, are needed to test patient benefit and clinical application.

  • Open Access

    Long-Term Clinical and Radiological Outcomes of Cementless Total Knee Arthroplasty in Patients with Rheumatoid Arthritis

    by Filippo Calanna, Silvia De Martinis, Leonardo Clausetti, Alessia Invernizzi, Luca Tanel, Roberto Viganò, Alessandra Menon, Alessio Maione, Riccardo Compagnoni, Paolo Ferrua, et al.

    Background: Total knee arthroplasty (TKA) is an established treatment for end-stage rheumatoid arthritis (RA). Although cemented fixation has traditionally been preferred because of concerns regarding poor bone quality, advances in implant design and osseointegration have renewed interest in cementless fixation. This study evaluated the long-term clinical and radiological outcomes of cementless TKA in patients with RA. Methods: A retrospective single-center study included adult patients with RA who underwent primary cementless TKA between 2004 and 2021 using the same cruciate retaining implant. Clinical outcomes were assessed using range of motion (ROM), Visual Analog Scale (VAS), Oxford Knee Score (OKS), and patient satisfaction. Radiographic evaluation assessed implant fixation, while implant survivorship was analyzed using bilateral clustering via a Marginal Cox model analysis. Results: Seventy-five cementless TKAs performed in 52 patients were analyzed after a mean clinical follow-up of 10.8 ± 3.8 years. Mean ROM was 101° ± 26.5°, mean VAS score was 0.88 ± 1.84, and mean OKS was 40.3 ± 7.1. Overall, patients were satisfied or very satisfied in 89.6% of implants. Radiographic assessment showed no evidence of progressive radiolucent lines, osteolysis, implant subsidence, aseptic loosening, or malalignment. Only one revision was required because of periprosthetic joint infection, resulting in an implant survivorship of 98.3% at long-term follow-up. Conclusions: Cementless TKA demonstrated excellent long-term implant survival, durable radiographic fixation, and favorable clinical and functional outcomes in patients with rheumatoid arthritis. These findings support modern cementless fixation as a reliable and effective alternative to cemented TKA in carefully selected RA patients.

  • Open Access

    Increased sagittal patellar height and reduced trochlear engagement on MRI are associated with recurrent patellar instability in skeletally immature knees: A comparative study

    by Francesco Puglia, Paolo Ferrua, David H. Dejour, Marco Nicoletti, Alessio Volpe, Riccardo Compagnoni, Antonio Memeo, Pietro Simone Randelli

    Purpose: To apply the magnetic resonance imaging (MRI)‐based concept of functional patella alta to skeletally immature patients and compare sagittal patellar height and trochlear engagement between paediatric knees with objective patellar instability (OPI) and controls without patellofemoral disorders. Methods: This retrospective study included 85 skeletally immature knees (42 OPI and 43 controls) from 83 patients undergoing MRI between 2021 and 2025. OPI required at least two lateral patellar dislocations. Measurements included patellar height index (PHI), sagittal patellar cartilage length (SPCL), patello‐tibial distance (PTD), patellar tendon length (PTL), sagittal trochlear cartilage length (STCL) and sagittal patellofemoral engagement (SPE). Three blinded observers measured every knee; their mean was analysed. Functional patella alta was defined using control‐derived interquartile‐range thresholds. Interobserver reliability used two‐way random‐effects, absolute‐agreement intraclass correlation coefficients (ICCs). Group comparisons and logistic regression were performed. Results: OPI knees had significantly higher PHI (1.178 ± 0.171 vs. 1.083 ± 0.132; p = 0.005) and lower SPE (0.354 ± 0.207 vs. 0.484 ± 0.200; p = 0.004), with greater SPCL, PTD and PTL and shorter STCL (all p < 0.05). Groups were unmatched for age, with older OPI patients ( p < 0.001). Functional patella alta occurred in 16/85 knees (18.8%): 14/42 OPI (33.3%) and 2/43 controls (4.7%) and was strongly associated with OPI (odds ratio [OR] 10.25; 95% confidence interval [CI] 2.16–48.66; p = 0.003). Reliability was excellent for SPE (ICC 0.95), PTL (0.97) and PTD (0.94), good for SPCL (0.80) and moderate for PHI (0.72). Conclusion: Paediatric recurrent patellar instability is characterised by increased patellar height and reduced sagittal trochlear engagement on MRI. Functional patella alta applies to skeletally immature knees, but instability occurs at lower sagittal engagement values than in adults. These cohort‐specific exploratory thresholds require external validation before clinical use. Level of Evidence: Level III, retrospective comparative study.

  • Synovial Pathologies of the Knee

    by Riccardo Compagnoni, Arianna Pieroni, Paolo Ferrua, Pietro Randelli

  • Arthroscopic Treatment of Tibial Plateau Fractures

    by Pietro Randelli, Riccardo Compagnoni, Arianna Pieroni, Carlo Minoli

  • Open Access

    All‐epiphyseal, all‐inside ACL reconstruction yields high return‐to‐sport and minimal growth‐related complications at mid‐ to long‐term follow‐up in skeletally immature patients

    by Panagiotis Ntagiopoulos, Georgios Kalinterakis, Pierrenzo Pozzi, Dimitris Fligkos, George Themistocleous, Sotirios Themistokleous, Triantafyllia Dimou, Riccardo Compagnoni, Paolo Ferrua, Pietro Simone Randelli

    Purpose: Paediatric anterior cruciate ligament (ACL) injuries are becoming increasingly frequent. Surgical management remains challenging due to the risk of growth plate disturbance. Physeal‐sparing techniques aim to restore stability while minimizing this risk. The purpose of this study is to evaluate the clinical, functional and radiological outcomes of an all‐inside, all‐epiphyseal ACL reconstruction in skeletally immature patients, with particular attention to complications, return to sport (RTS) and the influence of associated injuries. Methods: Seventy‐eight patients (48 males and 30 females; mean age 13.1 years, range: 9–16) underwent physeal‐sparing ACL reconstruction between 2015 and 2024. All procedures were performed using hamstring autograft with all‐epiphyseal sockets under fluoroscopic guidance. Pre‐ and postoperative assessments included plain radiographs, magnetic resonance imaging (MRI) and clinical evaluation. Outcome measures were Lysholm, Paediatric International Knee Documentation Committee (Pedi‐IKDC) and visual analogue scale (VAS) scores, recorded preoperatively and at a mean follow‐up of 48 months (range: 24–82). Return‐to‐play rates, complications and growth disturbances were documented. Subgroup analyses investigated the effect of meniscal/chondral lesions, gender and surgical delay. Results: Significant postoperative improvements were achieved in all clinical scores: Lysholm (53.4–94.6, p < 0.01), Pedi‐IKDC (53.5–90.6, p < 0.01) and VAS (5.6–1.8, p < 0.01). No growth arrest, angular deformities, or leg length discrepancies were identified. Complications included one infection, two re‐ruptures and one residual laxity. RTS was achieved in 94.8% of patients, with a mean recovery period of 11.1 months. Meniscal and chondral lesions were associated with inferior outcomes and delayed return‐to‐play. Delayed surgery significantly increased the risk of meniscal injury (odds ratio [OR]: 5.1, p = 0.001). Conclusion: All‐inside physeal‐sparing ACL reconstruction demonstrates excellent mid‐ to long‐term outcomes in skeletally immature patients. The technique offers high RTS rates and minimal growth‐related complications. Early surgical intervention may reduce the risk of secondary meniscal and chondral damage. Level of Evidence: Level IV, retrospective case series.


  • Open Access

    Palliative high tibial osteotomy achieves comparable outcomes to corrective osteotomy in varus knees with medial compartment osteoarthritis: A long‐term clinical and radiological retrospective study

    by Alessio Maione, Giuseppe Fedele, Pierrenzo Pozzi, Matteo Davide Parmigiani, Alessandra Menon, Filippo Calanna, Riccardo Compagnoni, Paolo Ferrua, Massimo Berruto, Pietro Simone Randelli

    Purpose: The long‐term outcomes of palliative high tibial osteotomy (PO) remain insufficiently defined. This study compared the clinical and radiological outcomes of PO with those of corrective osteotomy (CO) in patients with varus knee deformity. Secondary aim was to evaluate arthroplasty‐free survival. It was hypothesized that PO and CO would yield comparable results and similar conversion rates to total knee arthroplasty (TKA). Methods: A retrospective cohort study was conducted on patients who underwent lateral closing wedge‐high tibial osteotomy (LCW‐HTO) between 2001 and 2017. Patients with extra‐articular varus deformity (hip–knee–ankle angle [HKA] < 177°, lateral distal femoral angle [LDFA] > 90° or medial proximal tibial angle [MPTA] < 85°) were assigned to the CO group. Those with intra‐articular deformity and normal MPTA and LDFA were assigned to the PO group. Radiographic evaluation included HKA, MPTA, LDFA, joint line obliquity (JLO) and joint line convergence angle (JLCA). Clinical outcomes were assessed using the Hospital for Special Surgery (HSS) score, International Knee Documentation Committee (IKDC) subjective score, Numeric Rating Scale (NRS) for pain, Tegner Activity Scale and Crosby–Insall grading. Results: Forty patients were included, 20 in each group. The mean age was 49 ± 11 years, and the mean follow‐up was 10.5 ± 2.9 years. Preoperative HKA averaged 174° ± 3.3° and improved to 179° ± 1.5°. Moreover, 25% of PO patients and 10% of CO patients postoperatively exceeded the JLO threshold of ≤4°. Both groups demonstrated significant clinical improvement, with no between‐group differences except for higher HSS scores in the PO group. Osteoarthritis (OA) progression was limited, and TKA conversions were infrequent. Conclusion: PO may represent an effective joint‐preserving option for intra‐articular varus deformity. Despite less optimal correction of JLO and JLCA, PO achieved clinical and radiological outcomes comparable to CO, with similarly low conversion rates to TKA. Level of Evidence: Level IV, retrospective cohort study.

  • Open Access

    Various surgical techniques result in different outcomes for full extensor mechanism ruptures following total knee replacement: A systematic review by the European Knee Associates (ESSKA‐EKA)

    by Bruno Violante, Riccardo Compagnoni, Artur Kroell, Michael Engl, Octav Russu, George Mihai Avram, Sarper Gursu, Elvire Servien, Francesco Puglia, Pietro Simone Randelli, et al.

    Purpose: Extensor mechanism (EM) ruptures after total knee arthroplasty (TKA) are rare but lead to substantial functional impairment and morbidity. Treatment remains challenging due to the diversity of surgical techniques and the limited number of comparative studies. The European Knee Associates (EKA) group conducted a systematic review to evaluate available treatments for EM rupture following primary TKA, assess outcomes such as extensor lag, patient‐reported outcome measures (PROMs) and walking status, and to identify prevailing trends and complication rates. Methods: A systematic review was registered in PROSPERO (CRD42022341591) and conducted according to Preferred Reporting Items for Systematic Review and Meta‐Analysis and Cochrane guidelines. PubMed/Medline and Scopus databases were searched for clinical studies published between 2014 and 2024 reporting outcomes after EM repair in TKA patients. Inclusion criteria encompassed retrospective and prospective studies in English or German. Studies on EM ruptures due to infection, revision TKA, or patellectomy were excluded. Data extraction included demographics, time‐to‐reconstruction, repair type, extensor lag, PROMs and walking status. Due to heterogeneity, a meta‐analysis was not feasible, and results were descriptively reported. Results: A total of 32 studies comprising 893 EM rupture cases were included. The mean patient age was 66.8 years (standard deviation [SD] ± 7.4), with a mean body mass index of 34.5 (SD ± 6.2). Patellar tendon ruptures (39%) were the most frequent. Nine different surgical techniques were identified, including allografts, synthetic meshes, autografts and direct repairs. The overall complication rate was 16%, with autografts having the highest complication rate (38%). All repair techniques led to improvements in extensor lag and post‐operative Knee Society Scores exceeding the minimal clinically important difference thresholds. However, walking status and PROMs were inconsistently reported. Conclusions: EM failure after TKA remains a complex complication with variable outcomes depending on treatment strategy. Standardization of surgical techniques and outcome measures, along with multicenter collaborations, is crucial to improve future patient care as the number of TKA procedures continues to rise. Level of Evidence: Level III, systematic review of Level III studies.


  • Custom‐made total knee arthroplasty with mechanical alignment achieves 94% patient satisfaction at mid‐term follow‐up

    by Pietro Randelli, Valerio Monteleone, Paolo Ferrua, Alessio Maione, Joil Ramazzotti, Riccardo Compagnoni, Filippo Calanna

    Purpose: A notable proportion of patients remain dissatisfied following a total knee arthroplasty (TKA), often due to issues like prosthetic implant overhang, overstuffing, ligament imbalance and paradoxical motion. Custom made implants (CMI) aim to improve this condition by providing patient‐specific solutions tailored to individual knee joint characteristics. The purpose of this prospective study is to evaluate the clinical and radiological outcomes of patients undergoing CMI TKA. Methods: This prospective study evaluated clinically and radiologically 31 patients (33 knees) undergoing TKA with custom‐made prostheses implanted using mechanical alignment. Pre‐ and post‐operative assessments included patient‐reported outcome measures (PROMs), radiographic evaluations, and analysis of intraoperative and postoperative data. The mean follow‐up period was of 39 ± 22.6 months (range: 9–66 months). Results: Clinical outcomes, including functional scores and range of motion, showed significant improvements over time. Specifically, at a mean follow‐up of three years after the custom TKA, the Oxford Knee Score (OKS) improved from a preoperative value of 24.3 ± 8.5 to a postoperative value of 41.2 ± 5.9 ( p < 0.01), and the Knee Society Score (KSS) (functional) increased from 54.4 ± 14.2 to 89.8 ± 14.6 ( p < 0.01). Similarly, it was observed an increase in the Forgotten Joint Score (FJS), reaching an average value of 85.8 ± 27.0 (range: 15–100) three years post‐surgery. The radiographic analysis showed an increase in the mechanical Lateral Distal Femoral Angle (mLDFA) from 89.2 ± 4.4 to 90.6 ± 2.5 ( p = 0,03). No significant complications were observed, with the exception of one patient who was diagnosed with aseptic loosening. The overall satisfaction rate was 94%. Conclusions: CMI demonstrate good clinical and radiological outcomes at mid‐term follow‐up, encouraging further studies to support the potential implementation of this type of implant. Level of Evidence: Level II, prospective cohort study.