ABArno Bouwens

Arno Bouwens

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Arno Bouwens has a total of 89 co-authors. Here are the top co-authors by number of shared publications:

  • Theo Lasser

    Laboratoire d’Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne CH-1015, Switzerland

    18 shared publications
  • Daniel Szlag

    Laboratoire d’Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne CH-1015, Switzerland

    12 shared publications
  • Corinne Berclaz

    Laboratoire d'Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, CH1015, Lausanne, Switzerland

    6 shared publications
  • Jérôme Extermann

    Laboratoire d'Optique Biomédicale, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland

    6 shared publications
  • Tristan Bolmont

    Laboratoire d'Optique Biomédicale, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland

    6 shared publications
  • Paul James Marchand

    Laboratoire d'optique biomédicale (LOB) Swiss Federal Institute of Technology Lausanne (EPFL) CH-1015 Lausanne Switzerland

    5 shared publications

Latest Publications

  • Open Access

    Self-contained and modular structured illumination microscope

    by Robin Van Den Eynde, Wim Vandenberg, Siewert Hugelier, Arno Bouwens, Johan Hofkens, Marcel Müller, Peter Dedecker

    We present a modular implementation of structured illumination microscopy (SIM) that is fast, largely self-contained and that can be added onto existing fluorescence microscopes. Our instrument, which we call HIT-SIM, can theoretically deliver well over 50 super-resolved images per second and is readily compatible with existing acquisition software packages. We provide a full technical package consisting of schematics, a list of components and an alignment scheme that provides detailed specifications and assembly instructions. We illustrate the performance of the instrument by imaging optically large samples containing sequence-specifically stained DNA fragments.

  • Author Correction: Combined multi-plane phase retrieval and super-resolution optical fluctuation imaging for 4D cell microscopy

    by A. Descloux, K. S. Grußmayer, E. Bostan, T. Lukes, A. Bouwens, A. Sharipov, S. Geissbuehler, A.-L. Mahul-Mellier, H. A. Lashuel, M. Leutenegger, et al.


  • Imaging of cortical structures and microvasculature using extended-focus optical coherence tomography at 13 μm

    by Paul J. Marchand, Daniel Szlag, Jérôme Extermann, Arno Bouwens, David Nguyen, Markus Rudin, Theo Lasser

    Extended-focus optical coherence tomography (xf-OCT) is a variant of optical coherence tomography (OCT) wherein the illumination and/or detection modes are engineered to provide a constant diffractionless lateral resolution over an extended depth of field (typically 3 to 10× the Rayleigh range). xf-OCT systems operating at 800 nm have been devised and used in the past to image brain structures at high-resolution in vivo, but are limited to ∼500  μm in penetration depth due to their short illumination wavelength. Here we present an xf-OCT system optimized to an image deeper within the cortex by using a longer illumination central wavelength of 1310 nm. The system offers a lateral resolution of 3 and 6.5 μm, over a depth of 900 μm and >1.5  mm using a 10× and 5× objective, respectively, in air. We characterize the system’s resolution using microbeads embedded in PDMS and demonstrate its capabilities by imaging the cortical structure and microvasculature in anesthetized mice to a depth of ∼0.8  mm. Finally, we illustrate the difference in penetration depths obtainable with the new system and an xf-OCT system operating at 800 nm.


  • Open Access

    In vivo high-resolution cortical imaging with extended-focus optical coherence microscopy in the visible-NIR wavelength range

    by Paul J. Marchand, Daniel Szlag, Arno Bouwens, Theo Lasser

    Optical coherence tomography (OCT)1 has emerged in the past decade as a valuable tool to study cerebral physiology,2 3. 4. 5. – 6 through its ability to perform three-dimensional (3-D) imaging of tissue and vasculature at very high acquisition rates, with A-scan rates typically ranging from 10 to 100 kHz. Although most OCT systems operate in the infrared spectral range to maximize the penetration depth in tissue, recent studies have exploited a visible light source to benefit from the characteristic spectral signatures of certain endo- and exogeneous agents at shorter wavelengths.7,8 Such spectrosopic OCT systems have been used to increase the contrast of Alzheimeric plaques in brain tissue9 and to quantify hemoglobin concentration in the retina10,11 and in the brain.12,13 Shifting the central wavelength additionally enables increasing the axial resolution of OCT systems as it is determined by δz∝λc2/Δλ, where λc is the central wavelength of the source and Δλ is its bandwidth. Submicron axial resolutions can thus be reached by employing broadband sources in the visible wavelength range.9,14 15. 16. – 17 A higher lateral resolution is also gained through this illumination wavelength shift, as it is proportional to the ratio between the source’s central wavelength λc and the objective’s numerical aperture (NA). However, increasing the lateral resolution in conventional OCT systems reduces the depth-of-field (DOF) by restricting the confocal gating and effectively hampering the multiplexing advantage of Fourier domain OCT. As such, optical coherence microscopy18 (OCM), the high-NA version of OCT, might require an additional scan in depth to obtain 3-D images.19,20 This effect can be mitigated by splitting the illumination and detection modes of the OCM system and by illuminating the sample with so-called diffractionless beams, such as Bessel beams.21 The resulting system, termed extended-focus OCM (xfOCM),22 performs 3-D images with a high lateral resolution maintained over larger DOFs than conventional OCM setups (typically 3 to 10× larger). Recently, we developed a high-resolution xfOCM platform, combining an ultrabroadband source spanning from the visible to the near-infrared wavelength range (from 500 to 850 nm) with high NA optics, to perform submicron resolution imaging of fixed brain slices and living cells.16 Although its high resolution enables resolving subcellular structures, its ∼60  μm DOF limits its compatibility with in vivo cortical imaging. We therefore present a system based on our previous work, optimized for cortical imaging, where the lateral resolution was reduced to image over the entire penetration depth available with visible light (∼150  μm). The system’s resolution was characterized using a mirror and nanoparticles embedded in PDMS, and its imaging performance was assessed by imaging fine cerebral structures, such as myelinated axons, capillaries, and neuronal cells in the superficial somatosensory cortex of mice.


  • Combined multi-plane phase retrieval and super-resolution optical fluctuation imaging for 4D cell microscopy

    by A. Descloux, K. S. Grußmayer, E. Bostan, T. Lukes, A. Bouwens, A. Sharipov, S. Geissbuehler, A.-L. Mahul-Mellier, H. A. Lashuel, M. Leutenegger, et al.


  • Open Access

    Interferometric synthetic aperture microscopy for extended focus optical coherence microscopy

    by Séverine Coquoz, Arno Bouwens, Paul J. Marchand, Jérôme Extermann, Theo Lasser

    Optical coherence microscopy (OCM) is an interferometric technique providing 3D images of biological samples with micrometric resolution and penetration depth of several hundreds of micrometers. OCM differs from optical coherence tomography (OCT) in that it uses a high numerical aperture (NA) objective to achieve high lateral resolution. However, the high NA also reduces the depth-of-field (DOF), scaling with 1/NA2. Interferometric synthetic aperture microscopy (ISAM) is a computed imaging technique providing a solution to this trade-off between resolution and DOF. An alternative hardware method to achieve an extended DOF is to use a non-Gaussian illumination. Extended focus OCM (xfOCM) uses a Bessel beam to obtain a narrow and extended illumination volume. xfOCM detects back-scattered light using a Gaussian mode in order to maintain good sensitivity. However, the Gaussian detection mode limits the DOF. In this work, we present extended ISAM (xISAM), a method combining the benefits of both ISAM and xfOCM. xISAM uses the 3D coherent transfer function (CTF) to generalize the ISAM algorithm to different system configurations. We demonstrate xISAM both on simulated and experimental data, showing that xISAM attains a combination of high transverse resolution and extended DOF which has so far been unobtainable through conventional ISAM or xfOCM individually.


  • Open Access

    Correcting for photodestruction in super-resolution optical fluctuation imaging

    by Yves Peeters, Wim Vandenberg, Sam Duwé, Arno Bouwens, Tomáš Lukeš, Cyril Ruckebusch, Theo Lasser, Peter Dedecker

    Super-resolution optical fluctuation imaging overcomes the diffraction limit by analyzing fluctuations in the fluorophore emission. A key assumption of the imaging is that the fluorophores are independent, though this is invalidated in the presence of photodestruction. In this work, we evaluate the effect of photodestruction on SOFI imaging using theoretical considerations and computer simulations. We find that photodestruction gives rise to an additional signal that does not present an easily interpretable view of the sample structure. This additional signal is strong and the resulting images typically exhibit less noise. Accordingly, these images may be mis-interpreted as being more visually pleasing or more informative. To address this uncertainty, we develop a procedure that can robustly estimate to what extent any particular experiment is affected by photodestruction. We also develop a detailed assessment methodology and use it to evaluate the performance of several correction algorithms. We identify two approaches that can correct for the presence of even strong photodestruction, one of which can be implemented directly in the SOFI calculation software.


  • Open Access

    Label-free three-dimensional imaging of Caenorhabditis elegans with visible optical coherence microscopy

    by Séverine Coquoz, Paul J. Marchand, Arno Bouwens, Laurent Mouchiroud, Vincenzo Sorrentino, Daniel Szlag, Johan Auwerx, Theo Lasser

    Fast, label-free, high-resolution, three-dimensional imaging platforms are crucial for high-throughput in vivo time-lapse studies of the anatomy of Caenorhabditis elegans, one of the most commonly used model organisms in biomedical research. Despite the needs, methods combining all these characteristics have been lacking. Here, we present label-free imaging of live Caenorhabditis elegans with three-dimensional sub-micrometer resolution using visible optical coherence microscopy (visOCM). visOCM is a versatile optical imaging method which we introduced recently for tomography of cell cultures and tissue samples. Our method is based on Fourier domain optical coherence tomography, an interferometric technique that provides three-dimensional images with high sensitivity, high acquisition rate and micrometer-scale resolution. By operating in the visible wavelength range and using a high NA objective, visOCM attains lateral and axial resolutions below 1 μm. Additionally, we use a Bessel illumination offering an extended depth of field of approximately 40 μm. We demonstrate that visOCM’s imaging properties allow rapid imaging of full sized living Caenorhabditis elegans down to the sub-cellular level. Our system opens the door to many applications such as the study of phenotypic changes related to developmental or ageing processes.


  • Visible spectrum extended-focus optical coherence microscopy for label-free sub-cellular tomography

    by Paul J. Marchand, Arno Bouwens, Daniel Szlag, David Nguyen, Adrien Descloux, Miguel Sison, Séverine Coquoz, Jérôme Extermann, Theo Lasser

    We present a novel extended-focus optical coherence microscope (OCM) attaining 0.7 μm axial and 0.4 μm lateral resolution maintained over a depth of 40 μm, while preserving the advantages of Fourier domain OCM. Our system uses an ultra-broad spectrum from a supercontinuum laser source. As the spectrum spans from near-infrared to visible wavelengths (240 nm in bandwidth), we call the system visOCM. The combination of such a broad spectrum with a high-NA objective creates an almost isotropic 3D submicron resolution. We analyze the imaging performance of visOCM on microbead samples and demonstrate its image quality on cell cultures and ex-vivo brain tissue of both healthy and alzheimeric mice. In addition to neuronal cell bodies, fibers and plaques, visOCM imaging of brain tissue reveals fine vascular structures and sub-cellular features through its high spatial resolution. Sub-cellular structures were also observed in live cells and were further revealed through a protocol traditionally used for OCT angiography.


  • Open Access

    Statistical parametric mapping of stimuli evoked changes in total blood flow velocity in the mouse cortex obtained with extended-focus optical coherence microscopy

    by Paul J. Marchand, Arno Bouwens, Tristan Bolmont, Vincent K. Shamaei, David Nguyen, Daniel Szlag, Jérôme Extermann, Theo Lasser

    Functional magnetic resonance (fMRI) imaging is the current gold-standard in neuroimaging. fMRI exploits local changes in blood oxygenation to map neuronal activity over the entire brain. However, its spatial resolution is currently limited to a few hundreds of microns. Here we use extended-focus optical coherence microscopy (xfOCM) to quantitatively measure changes in blood flow velocity during functional hyperaemia at high spatio-temporal resolution in the somatosensory cortex of mice. As optical coherence microscopy acquires hundreds of depth slices simultaneously, blood flow velocity measurements can be performed over several vessels in parallel. We present the proof-of-principle of an optimised statistical parametric mapping framework to analyse quantitative blood flow timetraces acquired with xfOCM using the general linear model. We demonstrate the feasibility of generating maps of cortical hemodynamic reactivity at the capillary level with optical coherence microscopy. To validate our method, we exploited 3 stimulation paradigms, covering different temporal dynamics and stimulated limbs, and demonstrated its repeatability over 2 trials, separated by a week.