Arno Bouwens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Arno Bouwens has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
Theo Lasser
Laboratoire d’Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne CH-1015, Switzerland
18 shared publicationsDaniel Szlag
Laboratoire d’Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne CH-1015, Switzerland
12 shared publicationsCorinne Berclaz
Laboratoire d'Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, CH1015, Lausanne, Switzerland
6 shared publications- Jérôme Extermann
Laboratoire d'Optique Biomédicale, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
6 shared publications Tristan Bolmont
Laboratoire d'Optique Biomédicale, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
6 shared publications- Paul James Marchand
Laboratoire d'optique biomédicale (LOB) Swiss Federal Institute of Technology Lausanne (EPFL) CH-1015 Lausanne Switzerland
5 shared publications
Latest Publications
- Open Access
Self-contained and modular structured illumination microscope
We present a modular implementation of structured illumination microscopy (SIM) that is fast, largely self-contained and that can be added onto existing fluorescence microscopes. Our instrument, which we call HIT-SIM, can theoretically deliver well over 50 super-resolved images per second and is readily compatible with existing acquisition software packages. We provide a full technical package consisting of schematics, a list of components and an alignment scheme that provides detailed specifications and assembly instructions. We illustrate the performance of the instrument by imaging optically large samples containing sequence-specifically stained DNA fragments.
Open AccessSelf-contained and modular structured illumination microscope
We present a modular implementation of structured illumination microscopy (SIM) that is fast, largely self-contained and that can be added onto existing fluorescence microscopes. Our instrument, which we call HIT-SIM, can theoretically deliver well over 50 super-resolved images per second and is readily compatible with existing acquisition software packages. We provide a full technical package consisting of schematics, a list of components and an alignment scheme that provides detailed specifications and assembly instructions. We illustrate the performance of the instrument by imaging optically large samples containing sequence-specifically stained DNA fragments.
- 5 June 2018
- Published by Springer Nature in Nature Photonics
- Vol. 12 (7) , 438
Author Correction: Combined multi-plane phase retrieval and super-resolution optical fluctuation imaging for 4D cell microscopy
- 5 June 2018
- Published by Springer Nature in Nature Photonics
- Vol. 12 (7) , 438
Author Correction: Combined multi-plane phase retrieval and super-resolution optical fluctuation imaging for 4D cell microscopy
- 10 April 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (8) , 1782-1785
Imaging of cortical structures and microvasculature using extended-focus optical coherence tomography at 13 μm
Extended-focus optical coherence tomography (xf-OCT) is a variant of optical coherence tomography (OCT) wherein the illumination and/or detection modes are engineered to provide a constant diffractionless lateral resolution over an extended depth of field (typically 3 to the Rayleigh range). xf-OCT systems operating at 800 nm have been devised and used in the past to image brain structures at high-resolution in vivo, but are limited to in penetration depth due to their short illumination wavelength. Here we present an xf-OCT system optimized to an image deeper within the cortex by using a longer illumination central wavelength of 1310 nm. The system offers a lateral resolution of 3 and 6.5 μm, over a depth of 900 μm and using a and objective, respectively, in air. We characterize the system’s resolution using microbeads embedded in PDMS and demonstrate its capabilities by imaging the cortical structure and microvasculature in anesthetized mice to a depth of . Finally, we illustrate the difference in penetration depths obtainable with the new system and an xf-OCT system operating at 800 nm.- 10 April 2018
- Published by Optica Publishing Group in Optics Letters
- Vol. 43 (8) , 1782-1785
Imaging of cortical structures and microvasculature using extended-focus optical coherence tomography at 13 μm
Extended-focus optical coherence tomography (xf-OCT) is a variant of optical coherence tomography (OCT) wherein the illumination and/or detection modes are engineered to provide a constant diffractionless lateral resolution over an extended depth of field (typically 3 to the Rayleigh range). xf-OCT systems operating at 800 nm have been devised and used in the past to image brain structures at high-resolution in vivo, but are limited to in penetration depth due to their short illumination wavelength. Here we present an xf-OCT system optimized to an image deeper within the cortex by using a longer illumination central wavelength of 1310 nm. The system offers a lateral resolution of 3 and 6.5 μm, over a depth of 900 μm and using a and objective, respectively, in air. We characterize the system’s resolution using microbeads embedded in PDMS and demonstrate its capabilities by imaging the cortical structure and microvasculature in anesthetized mice to a depth of . Finally, we illustrate the difference in penetration depths obtainable with the new system and an xf-OCT system operating at 800 nm.- Open Access
- 24 March 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (03) , 036012-7
In vivo high-resolution cortical imaging with extended-focus optical coherence microscopy in the visible-NIR wavelength range
Optical coherence tomography (OCT)1 has emerged in the past decade as a valuable tool to study cerebral physiology,2 3. 4. 5. – 6 through its ability to perform three-dimensional (3-D) imaging of tissue and vasculature at very high acquisition rates, with A-scan rates typically ranging from 10 to 100 kHz. Although most OCT systems operate in the infrared spectral range to maximize the penetration depth in tissue, recent studies have exploited a visible light source to benefit from the characteristic spectral signatures of certain endo- and exogeneous agents at shorter wavelengths.7,8 Such spectrosopic OCT systems have been used to increase the contrast of Alzheimeric plaques in brain tissue9 and to quantify hemoglobin concentration in the retina10,11 and in the brain.12,13 Shifting the central wavelength additionally enables increasing the axial resolution of OCT systems as it is determined by , where is the central wavelength of the source and is its bandwidth. Submicron axial resolutions can thus be reached by employing broadband sources in the visible wavelength range.9,14 15. 16. – 17 A higher lateral resolution is also gained through this illumination wavelength shift, as it is proportional to the ratio between the source’s central wavelength and the objective’s numerical aperture (NA). However, increasing the lateral resolution in conventional OCT systems reduces the depth-of-field (DOF) by restricting the confocal gating and effectively hampering the multiplexing advantage of Fourier domain OCT. As such, optical coherence microscopy18 (OCM), the high-NA version of OCT, might require an additional scan in depth to obtain 3-D images.19,20 This effect can be mitigated by splitting the illumination and detection modes of the OCM system and by illuminating the sample with so-called diffractionless beams, such as Bessel beams.21 The resulting system, termed extended-focus OCM (xfOCM),22 performs 3-D images with a high lateral resolution maintained over larger DOFs than conventional OCM setups (typically 3 to larger). Recently, we developed a high-resolution xfOCM platform, combining an ultrabroadband source spanning from the visible to the near-infrared wavelength range (from 500 to 850 nm) with high NA optics, to perform submicron resolution imaging of fixed brain slices and living cells.16 Although its high resolution enables resolving subcellular structures, its DOF limits its compatibility with in vivo cortical imaging. We therefore present a system based on our previous work, optimized for cortical imaging, where the lateral resolution was reduced to image over the entire penetration depth available with visible light (). The system’s resolution was characterized using a mirror and nanoparticles embedded in PDMS, and its imaging performance was assessed by imaging fine cerebral structures, such as myelinated axons, capillaries, and neuronal cells in the superficial somatosensory cortex of mice.- 24 March 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (03) , 036012-7
Open AccessIn vivo high-resolution cortical imaging with extended-focus optical coherence microscopy in the visible-NIR wavelength range
Optical coherence tomography (OCT)1 has emerged in the past decade as a valuable tool to study cerebral physiology,2 3. 4. 5. – 6 through its ability to perform three-dimensional (3-D) imaging of tissue and vasculature at very high acquisition rates, with A-scan rates typically ranging from 10 to 100 kHz. Although most OCT systems operate in the infrared spectral range to maximize the penetration depth in tissue, recent studies have exploited a visible light source to benefit from the characteristic spectral signatures of certain endo- and exogeneous agents at shorter wavelengths.7,8 Such spectrosopic OCT systems have been used to increase the contrast of Alzheimeric plaques in brain tissue9 and to quantify hemoglobin concentration in the retina10,11 and in the brain.12,13 Shifting the central wavelength additionally enables increasing the axial resolution of OCT systems as it is determined by , where is the central wavelength of the source and is its bandwidth. Submicron axial resolutions can thus be reached by employing broadband sources in the visible wavelength range.9,14 15. 16. – 17 A higher lateral resolution is also gained through this illumination wavelength shift, as it is proportional to the ratio between the source’s central wavelength and the objective’s numerical aperture (NA). However, increasing the lateral resolution in conventional OCT systems reduces the depth-of-field (DOF) by restricting the confocal gating and effectively hampering the multiplexing advantage of Fourier domain OCT. As such, optical coherence microscopy18 (OCM), the high-NA version of OCT, might require an additional scan in depth to obtain 3-D images.19,20 This effect can be mitigated by splitting the illumination and detection modes of the OCM system and by illuminating the sample with so-called diffractionless beams, such as Bessel beams.21 The resulting system, termed extended-focus OCM (xfOCM),22 performs 3-D images with a high lateral resolution maintained over larger DOFs than conventional OCM setups (typically 3 to larger). Recently, we developed a high-resolution xfOCM platform, combining an ultrabroadband source spanning from the visible to the near-infrared wavelength range (from 500 to 850 nm) with high NA optics, to perform submicron resolution imaging of fixed brain slices and living cells.16 Although its high resolution enables resolving subcellular structures, its DOF limits its compatibility with in vivo cortical imaging. We therefore present a system based on our previous work, optimized for cortical imaging, where the lateral resolution was reduced to image over the entire penetration depth available with visible light (). The system’s resolution was characterized using a mirror and nanoparticles embedded in PDMS, and its imaging performance was assessed by imaging fine cerebral structures, such as myelinated axons, capillaries, and neuronal cells in the superficial somatosensory cortex of mice. - 26 February 2018
- Published by Springer Nature in Nature Photonics
- Vol. 12 (3) , 165-172
Combined multi-plane phase retrieval and super-resolution optical fluctuation imaging for 4D cell microscopy
- 26 February 2018
- Published by Springer Nature in Nature Photonics
- Vol. 12 (3) , 165-172
Combined multi-plane phase retrieval and super-resolution optical fluctuation imaging for 4D cell microscopy
- Open Access
- 22 November 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (24) , 30807-30819
Interferometric synthetic aperture microscopy for extended focus optical coherence microscopy
Optical coherence microscopy (OCM) is an interferometric technique providing 3D images of biological samples with micrometric resolution and penetration depth of several hundreds of micrometers. OCM differs from optical coherence tomography (OCT) in that it uses a high numerical aperture (NA) objective to achieve high lateral resolution. However, the high NA also reduces the depth-of-field (DOF), scaling with 1/NA2. Interferometric synthetic aperture microscopy (ISAM) is a computed imaging technique providing a solution to this trade-off between resolution and DOF. An alternative hardware method to achieve an extended DOF is to use a non-Gaussian illumination. Extended focus OCM (xfOCM) uses a Bessel beam to obtain a narrow and extended illumination volume. xfOCM detects back-scattered light using a Gaussian mode in order to maintain good sensitivity. However, the Gaussian detection mode limits the DOF. In this work, we present extended ISAM (xISAM), a method combining the benefits of both ISAM and xfOCM. xISAM uses the 3D coherent transfer function (CTF) to generalize the ISAM algorithm to different system configurations. We demonstrate xISAM both on simulated and experimental data, showing that xISAM attains a combination of high transverse resolution and extended DOF which has so far been unobtainable through conventional ISAM or xfOCM individually.
- 22 November 2017
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (24) , 30807-30819
Open AccessInterferometric synthetic aperture microscopy for extended focus optical coherence microscopy
Optical coherence microscopy (OCM) is an interferometric technique providing 3D images of biological samples with micrometric resolution and penetration depth of several hundreds of micrometers. OCM differs from optical coherence tomography (OCT) in that it uses a high numerical aperture (NA) objective to achieve high lateral resolution. However, the high NA also reduces the depth-of-field (DOF), scaling with 1/NA2. Interferometric synthetic aperture microscopy (ISAM) is a computed imaging technique providing a solution to this trade-off between resolution and DOF. An alternative hardware method to achieve an extended DOF is to use a non-Gaussian illumination. Extended focus OCM (xfOCM) uses a Bessel beam to obtain a narrow and extended illumination volume. xfOCM detects back-scattered light using a Gaussian mode in order to maintain good sensitivity. However, the Gaussian detection mode limits the DOF. In this work, we present extended ISAM (xISAM), a method combining the benefits of both ISAM and xfOCM. xISAM uses the 3D coherent transfer function (CTF) to generalize the ISAM algorithm to different system configurations. We demonstrate xISAM both on simulated and experimental data, showing that xISAM attains a combination of high transverse resolution and extended DOF which has so far been unobtainable through conventional ISAM or xfOCM individually.
- Open Access
- 5 September 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-10
Correcting for photodestruction in super-resolution optical fluctuation imaging
Super-resolution optical fluctuation imaging overcomes the diffraction limit by analyzing fluctuations in the fluorophore emission. A key assumption of the imaging is that the fluorophores are independent, though this is invalidated in the presence of photodestruction. In this work, we evaluate the effect of photodestruction on SOFI imaging using theoretical considerations and computer simulations. We find that photodestruction gives rise to an additional signal that does not present an easily interpretable view of the sample structure. This additional signal is strong and the resulting images typically exhibit less noise. Accordingly, these images may be mis-interpreted as being more visually pleasing or more informative. To address this uncertainty, we develop a procedure that can robustly estimate to what extent any particular experiment is affected by photodestruction. We also develop a detailed assessment methodology and use it to evaluate the performance of several correction algorithms. We identify two approaches that can correct for the presence of even strong photodestruction, one of which can be implemented directly in the SOFI calculation software.
- 5 September 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-10
Open AccessCorrecting for photodestruction in super-resolution optical fluctuation imaging
Super-resolution optical fluctuation imaging overcomes the diffraction limit by analyzing fluctuations in the fluorophore emission. A key assumption of the imaging is that the fluorophores are independent, though this is invalidated in the presence of photodestruction. In this work, we evaluate the effect of photodestruction on SOFI imaging using theoretical considerations and computer simulations. We find that photodestruction gives rise to an additional signal that does not present an easily interpretable view of the sample structure. This additional signal is strong and the resulting images typically exhibit less noise. Accordingly, these images may be mis-interpreted as being more visually pleasing or more informative. To address this uncertainty, we develop a procedure that can robustly estimate to what extent any particular experiment is affected by photodestruction. We also develop a detailed assessment methodology and use it to evaluate the performance of several correction algorithms. We identify two approaches that can correct for the presence of even strong photodestruction, one of which can be implemented directly in the SOFI calculation software.
- Open Access
- 20 July 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (7) , e0181676
Label-free three-dimensional imaging of Caenorhabditis elegans with visible optical coherence microscopy
Fast, label-free, high-resolution, three-dimensional imaging platforms are crucial for high-throughput in vivo time-lapse studies of the anatomy of Caenorhabditis elegans, one of the most commonly used model organisms in biomedical research. Despite the needs, methods combining all these characteristics have been lacking. Here, we present label-free imaging of live Caenorhabditis elegans with three-dimensional sub-micrometer resolution using visible optical coherence microscopy (visOCM). visOCM is a versatile optical imaging method which we introduced recently for tomography of cell cultures and tissue samples. Our method is based on Fourier domain optical coherence tomography, an interferometric technique that provides three-dimensional images with high sensitivity, high acquisition rate and micrometer-scale resolution. By operating in the visible wavelength range and using a high NA objective, visOCM attains lateral and axial resolutions below 1 μm. Additionally, we use a Bessel illumination offering an extended depth of field of approximately 40 μm. We demonstrate that visOCM’s imaging properties allow rapid imaging of full sized living Caenorhabditis elegans down to the sub-cellular level. Our system opens the door to many applications such as the study of phenotypic changes related to developmental or ageing processes.
- 20 July 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (7) , e0181676
Open AccessLabel-free three-dimensional imaging of Caenorhabditis elegans with visible optical coherence microscopy
Fast, label-free, high-resolution, three-dimensional imaging platforms are crucial for high-throughput in vivo time-lapse studies of the anatomy of Caenorhabditis elegans, one of the most commonly used model organisms in biomedical research. Despite the needs, methods combining all these characteristics have been lacking. Here, we present label-free imaging of live Caenorhabditis elegans with three-dimensional sub-micrometer resolution using visible optical coherence microscopy (visOCM). visOCM is a versatile optical imaging method which we introduced recently for tomography of cell cultures and tissue samples. Our method is based on Fourier domain optical coherence tomography, an interferometric technique that provides three-dimensional images with high sensitivity, high acquisition rate and micrometer-scale resolution. By operating in the visible wavelength range and using a high NA objective, visOCM attains lateral and axial resolutions below 1 μm. Additionally, we use a Bessel illumination offering an extended depth of field of approximately 40 μm. We demonstrate that visOCM’s imaging properties allow rapid imaging of full sized living Caenorhabditis elegans down to the sub-cellular level. Our system opens the door to many applications such as the study of phenotypic changes related to developmental or ageing processes.
- 20 June 2017
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (7) , 3343-3359
Visible spectrum extended-focus optical coherence microscopy for label-free sub-cellular tomography
We present a novel extended-focus optical coherence microscope (OCM) attaining 0.7 μm axial and 0.4 μm lateral resolution maintained over a depth of 40 μm, while preserving the advantages of Fourier domain OCM. Our system uses an ultra-broad spectrum from a supercontinuum laser source. As the spectrum spans from near-infrared to visible wavelengths (240 nm in bandwidth), we call the system visOCM. The combination of such a broad spectrum with a high-NA objective creates an almost isotropic 3D submicron resolution. We analyze the imaging performance of visOCM on microbead samples and demonstrate its image quality on cell cultures and ex-vivo brain tissue of both healthy and alzheimeric mice. In addition to neuronal cell bodies, fibers and plaques, visOCM imaging of brain tissue reveals fine vascular structures and sub-cellular features through its high spatial resolution. Sub-cellular structures were also observed in live cells and were further revealed through a protocol traditionally used for OCT angiography.
- 20 June 2017
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (7) , 3343-3359
Visible spectrum extended-focus optical coherence microscopy for label-free sub-cellular tomography
We present a novel extended-focus optical coherence microscope (OCM) attaining 0.7 μm axial and 0.4 μm lateral resolution maintained over a depth of 40 μm, while preserving the advantages of Fourier domain OCM. Our system uses an ultra-broad spectrum from a supercontinuum laser source. As the spectrum spans from near-infrared to visible wavelengths (240 nm in bandwidth), we call the system visOCM. The combination of such a broad spectrum with a high-NA objective creates an almost isotropic 3D submicron resolution. We analyze the imaging performance of visOCM on microbead samples and demonstrate its image quality on cell cultures and ex-vivo brain tissue of both healthy and alzheimeric mice. In addition to neuronal cell bodies, fibers and plaques, visOCM imaging of brain tissue reveals fine vascular structures and sub-cellular features through its high spatial resolution. Sub-cellular structures were also observed in live cells and were further revealed through a protocol traditionally used for OCT angiography.
- Open Access
- 2 December 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (1) , 1-15
Statistical parametric mapping of stimuli evoked changes in total blood flow velocity in the mouse cortex obtained with extended-focus optical coherence microscopy
Functional magnetic resonance (fMRI) imaging is the current gold-standard in neuroimaging. fMRI exploits local changes in blood oxygenation to map neuronal activity over the entire brain. However, its spatial resolution is currently limited to a few hundreds of microns. Here we use extended-focus optical coherence microscopy (xfOCM) to quantitatively measure changes in blood flow velocity during functional hyperaemia at high spatio-temporal resolution in the somatosensory cortex of mice. As optical coherence microscopy acquires hundreds of depth slices simultaneously, blood flow velocity measurements can be performed over several vessels in parallel. We present the proof-of-principle of an optimised statistical parametric mapping framework to analyse quantitative blood flow timetraces acquired with xfOCM using the general linear model. We demonstrate the feasibility of generating maps of cortical hemodynamic reactivity at the capillary level with optical coherence microscopy. To validate our method, we exploited 3 stimulation paradigms, covering different temporal dynamics and stimulated limbs, and demonstrated its repeatability over 2 trials, separated by a week.
- 2 December 2016
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (1) , 1-15
Open AccessStatistical parametric mapping of stimuli evoked changes in total blood flow velocity in the mouse cortex obtained with extended-focus optical coherence microscopy
Functional magnetic resonance (fMRI) imaging is the current gold-standard in neuroimaging. fMRI exploits local changes in blood oxygenation to map neuronal activity over the entire brain. However, its spatial resolution is currently limited to a few hundreds of microns. Here we use extended-focus optical coherence microscopy (xfOCM) to quantitatively measure changes in blood flow velocity during functional hyperaemia at high spatio-temporal resolution in the somatosensory cortex of mice. As optical coherence microscopy acquires hundreds of depth slices simultaneously, blood flow velocity measurements can be performed over several vessels in parallel. We present the proof-of-principle of an optimised statistical parametric mapping framework to analyse quantitative blood flow timetraces acquired with xfOCM using the general linear model. We demonstrate the feasibility of generating maps of cortical hemodynamic reactivity at the capillary level with optical coherence microscopy. To validate our method, we exploited 3 stimulation paradigms, covering different temporal dynamics and stimulated limbs, and demonstrated its repeatability over 2 trials, separated by a week.