Ali Kadivar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ali Kadivar has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Kaveh Niayesh
Department of Electrical Energy, the Norwegian University of Science and Technology (NTNU), Trondheim, Norway
3 shared publications Kaveh Niayesh
Department of Electric Power Engineering (IEL), NTNU, Trondheim, NORWAY
2 shared publications- Fahim Abid
Norwegian University of Science and Technology
1 shared publication - Majid Sanaye-Pasand
University of Tehran
1 shared publication Nina. Sasaki Støa-Aanensen
SINTEF Energy Research, Trondheim, Norway
1 shared publication
Latest Publications
- Open Access
- 10 November 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (5) , 055203
Metal vapor content of an electric arc initiated by exploding wire in a model N2 circuit breaker: simulation and experiment
A conductive wire can explode by rapidly heating it to vaporization temperature by flowing a current through it. This process is utilized to generate high-temperature high-density plasmas. The temperature and pressure distributions at the time of the explosion are not easily measured. Moreover, the amount of metal vapor from the wire that remains within the arcing area is unknown. This work presents the whole-process model of a single-wire electrical explosion from solid-state to plasma formation. For this purpose, the voltage drop and resistance of the exploding copper wire in solid-state are simulated through a zero-dimensional thermo-electrical model. Then, compressible Euler equations are implemented with nodal discontinuous Lagrange shape functions in a one-dimensional model to compute the flow of the generated copper vapor (due to the wire explosion) in surrounding nitrogen gas. The aim is to calculate the distributions of pressure, density, velocity, temperature, and mass flow along the cylindrical shock waves to estimate the arc’s copper/nitrogen mixture ratio in free burning and nozzle constricted arcs. This mixture ratio is used to calculate the precise percentage of the metal vapor in the arcing area and to calculate Townsend growth coefficients utilizing to estimate the streamer breakdown of the mixture. The simulation results show good agreement with the experimental results in terms of the temporal evolution of the plasma channel boundary, the shock front speed estimation as well as the arc voltage magnitude numerically calculated deploying the extracted mixture percentage from this study, manifesting the validity of the model. It shows that despite the low-pressure studies, the exploding wire method is not suitable for circuit breakers employing supercritical fluids as the insulation.
- 10 November 2020
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 54 (5) , 055203
Open AccessMetal vapor content of an electric arc initiated by exploding wire in a model N2 circuit breaker: simulation and experiment
A conductive wire can explode by rapidly heating it to vaporization temperature by flowing a current through it. This process is utilized to generate high-temperature high-density plasmas. The temperature and pressure distributions at the time of the explosion are not easily measured. Moreover, the amount of metal vapor from the wire that remains within the arcing area is unknown. This work presents the whole-process model of a single-wire electrical explosion from solid-state to plasma formation. For this purpose, the voltage drop and resistance of the exploding copper wire in solid-state are simulated through a zero-dimensional thermo-electrical model. Then, compressible Euler equations are implemented with nodal discontinuous Lagrange shape functions in a one-dimensional model to compute the flow of the generated copper vapor (due to the wire explosion) in surrounding nitrogen gas. The aim is to calculate the distributions of pressure, density, velocity, temperature, and mass flow along the cylindrical shock waves to estimate the arc’s copper/nitrogen mixture ratio in free burning and nozzle constricted arcs. This mixture ratio is used to calculate the precise percentage of the metal vapor in the arcing area and to calculate Townsend growth coefficients utilizing to estimate the streamer breakdown of the mixture. The simulation results show good agreement with the experimental results in terms of the temporal evolution of the plasma channel boundary, the shock front speed estimation as well as the arc voltage magnitude numerically calculated deploying the extracted mixture percentage from this study, manifesting the validity of the model. It shows that despite the low-pressure studies, the exploding wire method is not suitable for circuit breakers employing supercritical fluids as the insulation.
- Open Access
Effects of Fast Elongation on Switching Arcs Characteristics in Fast Air Switches
This paper is devoted to investigating the effects of high-speed elongation of arcs inside ultra-fast switches (ucontact 5–80 m/s), through a 2-D time-dependent model, in Cartesian coordinates. Two air arcs in series, one between a stationary anode and a moving cathode and the other between a stationary cathode and a moving anode in the arc chamber, are considered. A variable speed experimental setup through a Thomson drive actuator is designed to support this study. A computational fluid dynamics (CFD) equations system is solved for fluid velocity, pressure, temperature, and electric potential, as well as the magnetic vector potential. Electron emission mechanisms on the contact surface and induced current density due to magnetic field changes are also considered to describe the arc root formation, arc bending, lengthening, and calculating the arc current density, as well as the contact temperatures, in a better way. Data processing techniques are utilized to derive instantaneous core shape and profiles of the arc to investigate thermo-electrical characteristics during the elongation progress. The results are compared with another experimentally verified magnetohydrodynamics model of a fixed-length, free-burning arc in the air. The simulation and experimental results confirm each other.Open AccessEffects of Fast Elongation on Switching Arcs Characteristics in Fast Air Switches
This paper is devoted to investigating the effects of high-speed elongation of arcs inside ultra-fast switches (ucontact 5–80 m/s), through a 2-D time-dependent model, in Cartesian coordinates. Two air arcs in series, one between a stationary anode and a moving cathode and the other between a stationary cathode and a moving anode in the arc chamber, are considered. A variable speed experimental setup through a Thomson drive actuator is designed to support this study. A computational fluid dynamics (CFD) equations system is solved for fluid velocity, pressure, temperature, and electric potential, as well as the magnetic vector potential. Electron emission mechanisms on the contact surface and induced current density due to magnetic field changes are also considered to describe the arc root formation, arc bending, lengthening, and calculating the arc current density, as well as the contact temperatures, in a better way. Data processing techniques are utilized to derive instantaneous core shape and profiles of the arc to investigate thermo-electrical characteristics during the elongation progress. The results are compared with another experimentally verified magnetohydrodynamics model of a fixed-length, free-burning arc in the air. The simulation and experimental results confirm each other. - 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 216-220
Simulation of Free Burning Arcs and Arcs Inside Cylindrical Tubes Initiated by Exploding Wires
This paper is devoted to fundamental physics and numerical simulation of arcs initiated by an exploding wire. That is primarily used to perform simplified experiments on switching arcs without having complex moving contacts or for study the switching arc under controlled conditions. One of the main issues in the accuracy of these experiments is that a certain amount of metal vapor is inserted into the arcing medium, which can affect the switching arc characteristics through affecting the thermodynamic characteristics of the gas mixture.The current study aims to address this issue by solving the magneto-hydrodynamics (MHD) equations in local thermodynamic equilibrium (LTE) for temperature and electric potential. Impact of copper vapor on arc characteristics has been considered throughout modeling thermal and electrical conductivity as well as radiation properties for metal vapor percentage in the gas mixture.Current magnitude effect on arc characteristics is studied through increasing arc current to 300 and 600 A in experimentally verified MHD model for the free-burning arc. Results of the experimental setup are utilized to support and verify this study.Effects of severely arc quenching through very narrow tubes (150 A through nozzle diameter of 2 mm) on thermal arc behavior, maximum current density inside the tube and arc voltage oscillations near current zeros are investigated through MHD simulations. The simulation results show good agreement with the experimental results except at current zeros, where the LTE conditions are not fulfilled.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 216-220
Simulation of Free Burning Arcs and Arcs Inside Cylindrical Tubes Initiated by Exploding Wires
This paper is devoted to fundamental physics and numerical simulation of arcs initiated by an exploding wire. That is primarily used to perform simplified experiments on switching arcs without having complex moving contacts or for study the switching arc under controlled conditions. One of the main issues in the accuracy of these experiments is that a certain amount of metal vapor is inserted into the arcing medium, which can affect the switching arc characteristics through affecting the thermodynamic characteristics of the gas mixture.The current study aims to address this issue by solving the magneto-hydrodynamics (MHD) equations in local thermodynamic equilibrium (LTE) for temperature and electric potential. Impact of copper vapor on arc characteristics has been considered throughout modeling thermal and electrical conductivity as well as radiation properties for metal vapor percentage in the gas mixture.Current magnitude effect on arc characteristics is studied through increasing arc current to 300 and 600 A in experimentally verified MHD model for the free-burning arc. Results of the experimental setup are utilized to support and verify this study.Effects of severely arc quenching through very narrow tubes (150 A through nozzle diameter of 2 mm) on thermal arc behavior, maximum current density inside the tube and arc voltage oscillations near current zeros are investigated through MHD simulations. The simulation results show good agreement with the experimental results except at current zeros, where the LTE conditions are not fulfilled.
- Open Access
- 26 July 2019
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 52 (40) , 404003
Two-way interaction between switching arc and solid surfaces: distribution of ablated contact and nozzle materials
This paper is devoted to two-way plasma-surface interactions by investigating how the plasma arc ablates the nozzle and contacts and how the distribution of ablated materials changes the plasma parameters. For this purpose, a two-dimensional time-dependent model, in axial symmetric coordinates, for an arc at atmospheric pressure burning within a polytetrafluoroethylene nozzle is created. A computational fluid dynamics equations system is solved for plasma velocity, pressure, temperature, magnetic vector potential, and electrical potential. Radiation is modeled based on net emission coefficient and contacts, and nozzle ablation is also considered to better describe the arc formation, contact cooling, and arc temperatures, more precisely. The sublimated materials from contacts and nozzle will be used to calculate the distribution of plasma composition (i.e. ablated mixture ratio). The calculated ratio is used to change the plasma parameters, and data processing techniques are utilized to derive particle distribution and temperature profiles of the arc to investigate its thermo-electrical behavior. The simulation results show good agreement with the measurements obtained in an experimental setup already designed and published. This study provides support to the experimental work and contrariwise. The presence of ablated points on nozzle and contacts, which further modify plasma parameters and therefore the arc voltage are discussed.
- 26 July 2019
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 52 (40) , 404003
Open AccessTwo-way interaction between switching arc and solid surfaces: distribution of ablated contact and nozzle materials
This paper is devoted to two-way plasma-surface interactions by investigating how the plasma arc ablates the nozzle and contacts and how the distribution of ablated materials changes the plasma parameters. For this purpose, a two-dimensional time-dependent model, in axial symmetric coordinates, for an arc at atmospheric pressure burning within a polytetrafluoroethylene nozzle is created. A computational fluid dynamics equations system is solved for plasma velocity, pressure, temperature, magnetic vector potential, and electrical potential. Radiation is modeled based on net emission coefficient and contacts, and nozzle ablation is also considered to better describe the arc formation, contact cooling, and arc temperatures, more precisely. The sublimated materials from contacts and nozzle will be used to calculate the distribution of plasma composition (i.e. ablated mixture ratio). The calculated ratio is used to change the plasma parameters, and data processing techniques are utilized to derive particle distribution and temperature profiles of the arc to investigate its thermo-electrical behavior. The simulation results show good agreement with the measurements obtained in an experimental setup already designed and published. This study provides support to the experimental work and contrariwise. The presence of ablated points on nozzle and contacts, which further modify plasma parameters and therefore the arc voltage are discussed.
- 1 September 2014
- Published by Elsevier in Measurement
- Vol. 55, 473-486
Practical methods for electrical and mechanical measurement of high speed elongated arc parameters
- 1 September 2014
- Published by Elsevier in Measurement
- Vol. 55, 473-486
Practical methods for electrical and mechanical measurement of high speed elongated arc parameters
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5 pp.
Design of an online adaptive auto-reclose algorithm for HV transmission lines
This paper proposes an adaptive auto-reclose scheme for high voltage transmission lines. It presents application of wavelet transform in identification of transient and permanent faults by processing the fault generated high frequency voltage transients. It can also be utilised to determine adaptive reclosure time with capturing arc extinction time. A nonlinear time dependent dynamic resistance representation of the primary and secondary arcs is developed as well. Performance of the proposed method is validated by some simulation studies. Some simulations are carried out on a typical 400 kV circuit for various system and fault conditions and obtained results are presented in the paper
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5 pp.
Design of an online adaptive auto-reclose algorithm for HV transmission lines
This paper proposes an adaptive auto-reclose scheme for high voltage transmission lines. It presents application of wavelet transform in identification of transient and permanent faults by processing the fault generated high frequency voltage transients. It can also be utilised to determine adaptive reclosure time with capturing arc extinction time. A nonlinear time dependent dynamic resistance representation of the primary and secondary arcs is developed as well. Performance of the proposed method is validated by some simulation studies. Some simulations are carried out on a typical 400 kV circuit for various system and fault conditions and obtained results are presented in the paper