Jonathan J. Elsner
Research Subjects
Jonathan J. Elsner has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Eran Linder-Ganz
Research & Development Center, Active Implants Corporation, Netanya 42505, Israel
13 shared publications Avi Shterling
Research & Development Center, Active Implants Corporation, Netanya 42505, Israel
11 shared publications- Farshid Guilak
Washington University and Shriners Hospitals for Children
11 shared publications Gal Zur
Research and Development Center, Active Implants Corporation, Netanya 42505, Israel
6 shared publicationsMaoz Shemesh
Research and Development Center, Active Implants, Netanya 42505, Israel
4 shared publicationsMeital Zilberman
Department of Biomedical Engineering, The Iby and Aladar Fleischman Faculty of Engineering, Tel-Aviv University, Tel-Aviv 69978, Israel
4 shared publications
Latest Publications
- 1 September 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 49, 310-320
Quantification of in vitro wear of a synthetic meniscus implant using gravimetric and micro-CT measurements
- 1 September 2015
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 49, 310-320
Quantification of in vitro wear of a synthetic meniscus implant using gravimetric and micro-CT measurements
- 1 September 2014
- Published by Elsevier in Clinical Biomechanics
- Vol. 29 (8) , 898-905
In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: A pilot study using open-MRI
- 1 September 2014
- Published by Elsevier in Clinical Biomechanics
- Vol. 29 (8) , 898-905
In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: A pilot study using open-MRI
- 1 June 2014
- Published by Elsevier in Acta Biomaterialia
- Vol. 10 (6) , 2762-2768
Pore size distribution of bioresorbable films using a 3-D diffusion NMR method
- 1 June 2014
- Published by Elsevier in Acta Biomaterialia
- Vol. 10 (6) , 2762-2768
Pore size distribution of bioresorbable films using a 3-D diffusion NMR method
- 1 January 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 29, 42-55
Viscoelastic properties of a synthetic meniscus implant
- 1 January 2014
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 29, 42-55
Viscoelastic properties of a synthetic meniscus implant
- 26 June 2013
- Published by ASME International
Biomechanical Versus Clinical Considerations in the Development of a Novel Polycarbonate-Urethane Meniscus Implant
The menisci are semi-lunar wedge-shaped structures that play critical roles in load distribution, shock absorption, and joint congruity in the knee. Meniscal tears are common knee injuries that subsequently lead to degenerative arthritis, attributed primarily to the changes in stress distribution in the knee. In such cases there is a need to protect the articular cartilage by either repairing or replacing the menisci. While traditionally, meniscal replacement involves implantation of allografts, problems related to availability, size matching, cost and risk of disease transmission limit their use. Another potential treatment option is that of biodegradable scaffolds, which are based principally on tissue engineering concepts. The variability in body response to biodegradable implants and the quality of the tissue formed still pose a problem in this respect, particularly in light of the intense loading conditions in the knee. Moreover, the aforementioned repair and regenerative approaches are generally limited to younger patients. Therefore, the goal of this study was, to develop a synthetic meniscal implant which can replace the injured meniscus, restore its function, and relieve pain.
- 26 June 2013
- Published by ASME International
Biomechanical Versus Clinical Considerations in the Development of a Novel Polycarbonate-Urethane Meniscus Implant
The menisci are semi-lunar wedge-shaped structures that play critical roles in load distribution, shock absorption, and joint congruity in the knee. Meniscal tears are common knee injuries that subsequently lead to degenerative arthritis, attributed primarily to the changes in stress distribution in the knee. In such cases there is a need to protect the articular cartilage by either repairing or replacing the menisci. While traditionally, meniscal replacement involves implantation of allografts, problems related to availability, size matching, cost and risk of disease transmission limit their use. Another potential treatment option is that of biodegradable scaffolds, which are based principally on tissue engineering concepts. The variability in body response to biodegradable implants and the quality of the tissue formed still pose a problem in this respect, particularly in light of the intense loading conditions in the knee. Moreover, the aforementioned repair and regenerative approaches are generally limited to younger patients. Therefore, the goal of this study was, to develop a synthetic meniscal implant which can replace the injured meniscus, restore its function, and relieve pain.
- 26 June 2013
- Published by ASME International
Viscoelastic Properties of a Synthetic Meniscus Implant
Meniscal tears often lead to degenerative arthritis, attributed primarily to the changes in the magnitude and pattern of stress distribution in the knee. While meniscal replacement traditionally involves implantation of allografts, problems related to availability, size matching, and cost limit their use. In this regard, there are significant potential advantages to a bio-stable synthetic meniscus implant that combines long-term durability with a dependable biomechanical performance resembling that of the natural meniscus. The Nusurface® medial Meniscus Implant is a poly-(carbonate-urethane) implant that recreates the functionality of the meniscus, as evidenced by compression tests to determine its pressure distribution capability [1] and finite element analyses [2] in its virgin state. However, the overall success of such an implant is dependent on its long-term functional properties, and biomechanical testing of the NUsurface® device has not yet examined the effect of varying and dynamic testing conditions. In particular, the pre-test soaking in physiologic solution and the loading rate can have non-trivial influences on the properties of the device. Therefore the aims of this study were to characterize the strain-rate response, as well as the viscoelastic properties of the implant as measured by creep, stress relaxation, and hysteresis after simulated use.
- 26 June 2013
- Published by ASME International
Viscoelastic Properties of a Synthetic Meniscus Implant
Meniscal tears often lead to degenerative arthritis, attributed primarily to the changes in the magnitude and pattern of stress distribution in the knee. While meniscal replacement traditionally involves implantation of allografts, problems related to availability, size matching, and cost limit their use. In this regard, there are significant potential advantages to a bio-stable synthetic meniscus implant that combines long-term durability with a dependable biomechanical performance resembling that of the natural meniscus. The Nusurface® medial Meniscus Implant is a poly-(carbonate-urethane) implant that recreates the functionality of the meniscus, as evidenced by compression tests to determine its pressure distribution capability [1] and finite element analyses [2] in its virgin state. However, the overall success of such an implant is dependent on its long-term functional properties, and biomechanical testing of the NUsurface® device has not yet examined the effect of varying and dynamic testing conditions. In particular, the pre-test soaking in physiologic solution and the loading rate can have non-trivial influences on the properties of the device. Therefore the aims of this study were to characterize the strain-rate response, as well as the viscoelastic properties of the implant as measured by creep, stress relaxation, and hysteresis after simulated use.
- Open Access
- 31 May 2011
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 29 (12) , 1859-1866
Long‐term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: A 20 million cycles wear simulation
Soft bearing materials that aim to reproduce the tribological function of the natural joint are gaining popularity as an alternative concept to conventional hard bearing materials in the hip and knee. However, it has not been proven so far that an elastic cushion bearing can be sufficiently durable as a long term (∼20 years) articulating joint prosthesis. The use of new bearing materials should be supported by accurate descriptions of the implant following usage and of the number, volume, and type of wear particles generated. We report on a long‐term 20 million cycle (Mc) wear study of a commercial hip replacement system composed of a compliant polycarbonate‐urethane (PCU) acetabular liner coupled to a cobalt–chromium alloy femoral head. The PCU liner showed excellent wear characteristics in terms of its low and steady volumetric wear rate (5.8–7.7 mm3/Mc) and low particle generation rate (2–3 × 106particles/Mc). The latter is 5–6 orders of magnitude lower than that of highly cross‐linked polyethylene and 6–8 orders of magnitude lower than that of metal‐on‐metal bearings. Microscopic analysis of the implants after the simulation demonstrated a low damage level to the implants' articulating surfaces. Thus, the compliant PCU bearing may provide a substantial advantage over traditional bearing materials. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 29:1859–1866, 2011
- 31 May 2011
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 29 (12) , 1859-1866
Open AccessLong‐term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: A 20 million cycles wear simulation
Soft bearing materials that aim to reproduce the tribological function of the natural joint are gaining popularity as an alternative concept to conventional hard bearing materials in the hip and knee. However, it has not been proven so far that an elastic cushion bearing can be sufficiently durable as a long term (∼20 years) articulating joint prosthesis. The use of new bearing materials should be supported by accurate descriptions of the implant following usage and of the number, volume, and type of wear particles generated. We report on a long‐term 20 million cycle (Mc) wear study of a commercial hip replacement system composed of a compliant polycarbonate‐urethane (PCU) acetabular liner coupled to a cobalt–chromium alloy femoral head. The PCU liner showed excellent wear characteristics in terms of its low and steady volumetric wear rate (5.8–7.7 mm3/Mc) and low particle generation rate (2–3 × 106particles/Mc). The latter is 5–6 orders of magnitude lower than that of highly cross‐linked polyethylene and 6–8 orders of magnitude lower than that of metal‐on‐metal bearings. Microscopic analysis of the implants after the simulation demonstrated a low damage level to the implants' articulating surfaces. Thus, the compliant PCU bearing may provide a substantial advantage over traditional bearing materials. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 29:1859–1866, 2011
- 1 January 2011
- Published by Elsevier in Acta Biomaterialia
- Vol. 7 (1) , 325-336
In vitro microbial inhibition and cellular response to novel biodegradable composite wound dressings with controlled release of antibiotics
- 1 January 2011
- Published by Elsevier in Acta Biomaterialia
- Vol. 7 (1) , 325-336
In vitro microbial inhibition and cellular response to novel biodegradable composite wound dressings with controlled release of antibiotics
- 1 December 2010
- Published by Elsevier in Acta Biomaterialia
- Vol. 6 (12) , 4698-4707
Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints
- 1 December 2010
- Published by Elsevier in Acta Biomaterialia
- Vol. 6 (12) , 4698-4707
Wear rate evaluation of a novel polycarbonate-urethane cushion form bearing for artificial hip joints