Jeanette M. Torrescano‐Alvarez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeanette M. Torrescano‐Alvarez has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
M. Curioni
3 shared publicationsP. Skeldon
2 shared publications- Xiangrong Zhou
The University of Manchester
2 shared publications Fabio Scenini
Corrosion and Protection Centre, School of Materials, University of Manchester, Manchester M13-9PL, United Kingdom
1 shared publicationH. Habazaki
1 shared publicationMichele Curioni
Corrosion and Protection Centre, School of Materials The University of Manchester Manchester M13 9PL UK
1 shared publication
Latest Publications
- 1 February 2019
- Published by Elsevier in Electrochimica Acta
- Vol. 296, 783-789
Incorporation of alloying elements into porous anodic films on aluminium alloys: The role of cell diameter
- 1 February 2019
- Published by Elsevier in Electrochimica Acta
- Vol. 296, 783-789
Incorporation of alloying elements into porous anodic films on aluminium alloys: The role of cell diameter
- 14 September 2018
- Published by Wiley in Surface and Interface Analysis
- Vol. 51 (12) , 1135-1143
Effect of anodizing conditions on the cell morphology of anodic films on AA2024‐T3 alloy
The effects of applied current density, anodizing time, and electrolyte temperature on the cell and pore morphology of anodic films and the voltage‐time response obtained during galvanostatic anodizing of AA2024‐T3 alloy in sulphuric acid electrolytes have been studied. Scanning electron microscopy was employed to observe the film morphology. Sponge‐like porous structure was promoted by anodizing at relatively low current density and high electrolyte temperature. In contrast, linear porous structure was favoured under the converse conditions. Intermediate conditions resulted in films containing either sequential layers of the 2 morphologies or a morphology incorporating features of the 2 types; such conditions were associated with anodizing voltages in the range 25 to 35 V. The reasons for the morphological differences are proposed to be due to interactions between film growth stresses and stresses arising from oxygen evolution on the development of the alumina cells.
- 14 September 2018
- Published by Wiley in Surface and Interface Analysis
- Vol. 51 (12) , 1135-1143
Effect of anodizing conditions on the cell morphology of anodic films on AA2024‐T3 alloy
The effects of applied current density, anodizing time, and electrolyte temperature on the cell and pore morphology of anodic films and the voltage‐time response obtained during galvanostatic anodizing of AA2024‐T3 alloy in sulphuric acid electrolytes have been studied. Scanning electron microscopy was employed to observe the film morphology. Sponge‐like porous structure was promoted by anodizing at relatively low current density and high electrolyte temperature. In contrast, linear porous structure was favoured under the converse conditions. Intermediate conditions resulted in films containing either sequential layers of the 2 morphologies or a morphology incorporating features of the 2 types; such conditions were associated with anodizing voltages in the range 25 to 35 V. The reasons for the morphological differences are proposed to be due to interactions between film growth stresses and stresses arising from oxygen evolution on the development of the alumina cells.
- 1 June 2018
- Published by Elsevier in Electrochimica Acta
- Vol. 275, 172-181
Effects of oxygen evolution on the voltage and film morphology during galvanostatic anodizing of AA 2024-T3 aluminium alloy in sulphuric acid at −2 and 24 °C
- 1 June 2018
- Published by Elsevier in Electrochimica Acta
- Vol. 275, 172-181
Effects of oxygen evolution on the voltage and film morphology during galvanostatic anodizing of AA 2024-T3 aluminium alloy in sulphuric acid at −2 and 24 °C
- Open Access
- 27 September 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , C728-C734
Gravimetric Measurement of Oxygen Evolution during Anodizing of Aluminum Alloys
A gravimetric method based on changes in buoyancy force of a submerged gas-collecting container has been optimized to measure the evolution of oxygen during anodizing of an aluminum alloy. Previously, the gravimetric method has been used to measure hydrogen evolution from magnesium and aluminum during corrosion processes, either at the free corrosion potential or under relatively low polarization. However, during anodizing, the comparatively higher values of current applied and the heating effects associated with power dissipation might introduce artefacts in the gas measurement. Optimization of the experimental setup enabled reduction or elimination of such artefacts, so that a reliable measurement could be obtained. The results show that typically about 15 to 20% of the current applied to an AA 2024-T3 aluminum alloy during anodizing in sulfuric acid under the present conditions was used in generating oxygen.
- 27 September 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (13) , C728-C734
Open AccessGravimetric Measurement of Oxygen Evolution during Anodizing of Aluminum Alloys
A gravimetric method based on changes in buoyancy force of a submerged gas-collecting container has been optimized to measure the evolution of oxygen during anodizing of an aluminum alloy. Previously, the gravimetric method has been used to measure hydrogen evolution from magnesium and aluminum during corrosion processes, either at the free corrosion potential or under relatively low polarization. However, during anodizing, the comparatively higher values of current applied and the heating effects associated with power dissipation might introduce artefacts in the gas measurement. Optimization of the experimental setup enabled reduction or elimination of such artefacts, so that a reliable measurement could be obtained. The results show that typically about 15 to 20% of the current applied to an AA 2024-T3 aluminum alloy during anodizing in sulfuric acid under the present conditions was used in generating oxygen.
- 14 December 2016
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 73 (5) , 463-470
Application of Side-View Imaging and Real-Time Hydrogen Measurement to the Investigation of Magnesium Corrosion
This work illustrates how side-view optical imaging, anodic potentiodynamic polarization, and real-time hydrogen evolution measurements can be applied and complementarily used to study the processes occurring on a corroding magnesium surface. Side-view imaging reveals that hydrogen evolution takes three different forms: (i) large and stable bubbles on the uncorroded regions, (ii) a stream of fine hydrogen bubbles at the corrosion front, and (iii) medium-sized bubbles behind the corrosion front. The observation suggests that the relatively large bubbles ahead and behind the corrosion front are associated with a purely cathodic reaction that provides the “remote current.” This current, combined with the depassivating role of chloride ions, maintains the corrosion front active, generating regions where either the metal is locally directly exposed to the electrolyte or is only covered by a poorly protective chloride-rich film. Regardless of the precise nature or morphology of the poorly protective (or absent) surface film at the corrosion front, additional hydrogen evolution occurs as a result of the large overpotential available. Overall, the anodic current associated with magnesium oxidation is the sum of the “remote current,” which is manifested with hydrogen evolution ahead and behind the corrosion front, and the “local” current associated with hydrogen evolution at the corrosion front. From the electrical viewpoint, the corrosion front acts as a current amplifier, where the current amplification effect can be measured directly by real-time gravimetric hydrogen measurement performed simultaneously with anodic potentiodynamic polarization.
- 14 December 2016
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 73 (5) , 463-470
Application of Side-View Imaging and Real-Time Hydrogen Measurement to the Investigation of Magnesium Corrosion
This work illustrates how side-view optical imaging, anodic potentiodynamic polarization, and real-time hydrogen evolution measurements can be applied and complementarily used to study the processes occurring on a corroding magnesium surface. Side-view imaging reveals that hydrogen evolution takes three different forms: (i) large and stable bubbles on the uncorroded regions, (ii) a stream of fine hydrogen bubbles at the corrosion front, and (iii) medium-sized bubbles behind the corrosion front. The observation suggests that the relatively large bubbles ahead and behind the corrosion front are associated with a purely cathodic reaction that provides the “remote current.” This current, combined with the depassivating role of chloride ions, maintains the corrosion front active, generating regions where either the metal is locally directly exposed to the electrolyte or is only covered by a poorly protective chloride-rich film. Regardless of the precise nature or morphology of the poorly protective (or absent) surface film at the corrosion front, additional hydrogen evolution occurs as a result of the large overpotential available. Overall, the anodic current associated with magnesium oxidation is the sum of the “remote current,” which is manifested with hydrogen evolution ahead and behind the corrosion front, and the “local” current associated with hydrogen evolution at the corrosion front. From the electrical viewpoint, the corrosion front acts as a current amplifier, where the current amplification effect can be measured directly by real-time gravimetric hydrogen measurement performed simultaneously with anodic potentiodynamic polarization.