MPMasauso Moses Phiri

Masauso Moses Phiri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masauso Moses Phiri has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Miniaturization and Automation Protocol of a Urinary Organic Acid Liquid-Liquid Extraction Method on GC-MS

    by Masauso Moses Phiri, Elmarie Davoren, Barend Christiaan Vorster

    The aim of this study was to improve the extraction method for urinary organic acids by miniaturizing and automating the process. Currently, manual extraction methods are commonly used, which can be time-consuming and lead to variations in test results. To address these issues, we reassessed and miniaturized the in-house extraction method, reducing the number of steps and the sample-to-solvent volumes required. The evaluated miniaturized method was translated into an automated extraction procedure on a MicroLab (ML) Star (Hamilton Technologies) liquid handler. This was then validated using samples obtained from the ERNDIM External Quality Assurance program. The organic acid extraction method was successfully miniaturized and automated using the Autosampler robot. The linear range for most of the thirteen standard analytes fell between 0 to 300 mg/L in spiked synthetic urine, with low (50 mg/L), medium (100 mg/L), and high (500 mg/L) levels. The correlation coefficient (r) for most analytes was >0.99, indicating a strong relationship between the measured values. Furthermore, the automated extraction method demonstrated acceptable precision, as most organic acids had coefficients of variation (CVs) below 20%. In conclusion, the automated extraction method provided comparable or even superior results compared to the current in-house method. It has the potential to reduce solvent volumes used during extraction, increase sample throughput, and minimize variability and random errors in routine diagnostic settings.


  • Open Access

    Tobacco Use among HIV-Positive and HIV-Negative Women and Men in Zambia—Demographic and Health Survey, 2018

    by Alissa C. Kress, Carlen Stadnik, Masauso Moses Phiri, Fastone M. Goma, Evelyn Twentyman

    Country-specific estimates of tobacco use among people living with HIV (PLWH) are lacking for much of sub-Saharan Africa. We aim to evaluate the association between the HIV status and tobacco product use status, frequency, and intensity, using nationally representative data from Zambia. We analyzed data from the 2018 Demographic and Health Survey conducted in Zambia among women aged 15–49 years and men aged 15–59 years. We performed logistic regression to assess the associations of HIV status, selected sociodemographic, and other characteristics with indicators of tobacco use (i.e., status, frequency, and intensity). Among women, 14.3% tested positive for HIV and 2.7% reported current smoking or tobacco use; women living with HIV were more likely to report currently smoking or using tobacco than women living without HIV (4.4% vs. 2.4%; aPR: 1.46). Among men, 8.4% tested positive for HIV and 19.5% reported current smoking; men living with HIV were more likely than men living without HIV to report current smoking (27.8% vs. 18.7%; aPR: 1.22). Several sociodemographic characteristics were associated with tobacco use, including age, residence (urban/rural), education level, employment status, and wealth index. The frequency and intensity of smoking among men who currently smoked did not differ by HIV status. Tobacco use was more likely in PLWH than those without HIV in Zambia. Our findings highlight the need to encourage and support tobacco cessation among PLWH, possibly by offering cessation services at existing intersections with health care or integrating cessation support into mHealth and other alternative models of care.


  • Open Access

    Demographic characteristics associated with awareness of cigarette health warnings and thinking about quitting among current adult cigarette smokers in Zambia, 2017

    by Masauso M. Phiri, April D. Summers, Alissa C. Kress, Isabel Garcia de Quevedo, Ralph Caraballo, Evelyn Twentyman

    Introduction: Noticing health warnings on cigarette packages has been associated with thinking about quitting. This study examined sociodemographic characteristics associated with awareness of health warnings on cigarette packages and thinking about quitting because of health warning labels...


  • Open Access

    Diagnostic accuracy of Schistosoma immunochromatographic IgG/IgM rapid test in the detection of schistosomiasis in Zambia

    by Jolezya Mudenda, Benson M. Hamooya, Shadreck Tembo, Hikabasa Halwindi, Joyce Siwila, Masauso Moses Phiri

    Background: Schistosomiasis or bilharzia is one of the neglected tropical diseases affecting over 230 million people globally. In Zambia, the infection poses as one of the major public health burdens among parasitic infections. The diagnosis of schistosomiasis in endemic countries is still a challenge. The aim of this study was to evaluate the diagnostic performance of the Schistosoma immunochromatographic (ICT) IgG–IgM rapid diagnostic test in the detection of schistosome infections from Schistosoma haematobium and mansoni in Siavonga district in Zambia. Results: The diagnostic performance of Schistosoma ICT IgG–IgM test was evaluated using 430 of the 440 participants’ samples which had complete data. The prevalence of S. haematobium and S. mansoni was 4.4% and 6%, respectively, while seroprevalence was 71.4%. The sensitivity and specificity of the Schistosoma ICT IgG–IgM test was found to be 100% and 32.2%, respectively. The associated positive predictive value was 13.8% and 100% for negative predictive value. Diagnostic accuracy [area under the curve (AUC)] was 0.57 [95% confidence interval (CI) 0.52, 0.62]. Conclusions: The Schistosoma ICT IgG–IgM proved to have remarkably high sensitivity with a fairly good specificity and diagnostic accuracy for the detection of both urinary and intestinal schistosomiasis. We therefore recommend the test as it is ideal for screening in the light of current focus of disease elimination in endemic countries.


  • Open Access

    Gold Nanostar Colorimetric Detection of Fructosyl Valine as a Potential Future Point of Care Biosensor Candidate for Glycated Haemoglobin Detection

    by Danielle Wingrove Mulder, Masauso Moses Phiri, Barend Christiaan Vorster

    Diabetes Mellitus is a growing global concern. The current methods used to detect glycated haemoglobin are precise, however, utilise expensive equipment, reagents and consumables. These are luxuries which rural communities cannot access. The nanotechnology methods which have been developed for glycated haemoglobin detection are predominantly electrochemically based, have complicated lengthy fabrication processes and utilise toxic chemicals. Here a fructosyl amino acid oxidase gold nanostar biosensor has been developed as a potential future point of care biosensor candidate for glycated haemoglobin detection. The workup done on this biosensor showed that it was able to give a spectrophotometric readout and colorimetric result with naked eye detection in blank serum spiked with fructosyl valine.


  • Open Access

    Plasmonic Detection of Glucose in Serum Based on Biocatalytic Shape-Altering of Gold Nanostars

    by Masauso Moses Phiri, Danielle Wingrove Mulder, Barend Christiaan Vorster

    Nanoparticles have been used as signal transducers for optical readouts in biosensors. Optical approaches are cost-effective with easy readout formats for clinical diagnosis. We present a glucose biosensor based on the biocatalytic shape-altering of gold nanostars via silver deposition. Improved sensitivity was observed due to the nanostars clustering after being functionalised with glucose oxidase (GOx). The biosensor quantified glucose in the serum samples with a 1:1000 dilution factor, and colorimetrically distinguished between the concentrations. The assay demonstrated good specificity and sensitivity. The fabricated glucose biosensor is a rapid kinetic assay using a basic entry level laboratory spectrophotometric microplate reader. Such a biosensor could be very useful in resource-constrained regions without state-of-the-art laboratory equipment. Furthermore, naked eye detection of glucose makes this a suitable biosensor for technology transfer to other point-of-care devices.


  • Open Access

    Modified HEPES one-pot synthetic strategy for gold nanostars

    by Danielle Wingrove Mulder, Masauso Moses Phiri, Anine Jordaan, Barend Christiaan Vorster

    Gold nanostars are being used more regularly in the biosensing field. Despite their useful attributes, there is still a need to optimize aspects of the synthesis and stability. The seedless, synthetic method comprising 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) is a facile, rapid method; however, it produces heteromorphic nanostars. The modification of a HEPES method resulted in a silver-assisted, seedless gold nanostar synthesis method. The nanostars resulting from this method were monodispersed, multi-branched and approximately 37 ± 2 nm in diameter. It proved to be a repeatable method that produced homogeneous and robust nanostars. Once functionalized with polyvinylpyrrolidone 10 000, the new nanostars were observed to be stable in various environments such as salt, ionic strength and cell culture medium. In conclusion, the addition of the silver nitrate improved the morphology of the reported HEPES nanostars for the purpose of nanobiosensor development.


  • Open Access

    Facile immobilization of glucose oxidase onto gold nanostars with enhanced binding affinity and optimal function

    by Masauso Moses Phiri, Danielle Wingrove Mulder, Shayne Mason, Barend Christiaan Vorster

    Gold nanoparticles provide a user-friendly and efficient surface for immobilization of enzymes and proteins. In this paper, we present a novel approach for enzyme bioconjugation to gold nanostars (AuNSs). AuNSs were modified with l -cysteine (Cys) and covalently bound to N -hydroxysulfosuccinimide (sulfo-NHS) activated intermediate glucose oxidase (GOx) to fabricate a stable and sensitive AuNSs–Cys–GOx bioconjugate complex. Such a strategy has the potential for increased attachment affinity without protein adsorption onto the AuNSs surface. Good dispersity in buffer suspension was observed, as well as stability in high ionic environments. Using the AuNSs–Cys–GOx bioconjugates showed greater sensitivity in the measuring of low concentrations of glucose based on plasmonic and colorimetric detection. Such a novel approach for enzyme immobilization can lead to AuNSs–Cys–GOx bioconjugate complexes that can be used as catalytic nanodevices in nanobiosensors based on oxidases in biomedical applications.


  • Open Access

    Seedless gold nanostars with seed-like advantages for biosensing applications

    by Masauso Moses Phiri, Danielle Wingrove Mulder, Barend Christiaan Vorster

    Gold nanostars (AuNSs) are seen as promising building blocks for biosensors with potential for easy readouts based on naked-eye and ultraviolet–visible spectroscopy detection. We present a seedless synthesis strategy for AuNSs that has the advantages of the seeded methods. The method used ascorbic acid as a reducing agent and silver nitrate as an anisotropic growth control assisting agent. AuNSs with multiple branches and a diameter of 59 nm were produced. They showed good stability when capped with PVP and modified with an enzyme in relatively strong ionic conditions. We investigated their application in plasmonic sensing by modifying them with glucose oxidase and detection of glucose. The AuNSs were found to be a good scaffold for the enzyme, proved to be stable and sensitive as transducers. Thus, the AuNSs showed good promise for further applications in plasmonic biosensing for in vivo biomedical diagnosis.