Richard M. Crooks

Richard M. Crooks

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Richard M. Crooks has a total of 312 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers

    33 Unresolved Questions in Nanoscience and Nanotechnology

    by Chad A. Mirkin, Sarah Hurst Petrosko, Natalie Artzi, Koray Aydin, Austin Biaggne, C. Jeffrey Brinker, Katherine E. Bujold, Y. Charles Cao, Rachel R. Chan, Chaojian Chen, et al.

    Significant advances in science and engineering often emerge at the intersections of disciplines. Nanoscience and nanotechnology are inherently interdisciplinary, uniting researchers from chemistry, physics, biology, medicine, materials science, and engineering. This convergence has fostered novel ways of thinking and enabled the development of materials, tools, and technologies that have transformed both basic and applied research, as well as how we address critical societal challenges. In this Nano Focus, we pose and explore 33 questions whose answers could profoundly impact fields such as energy, electronics, the environment, optics, and medicine. These questions highlight the need for deeper foundational understanding, improved tools and techniques, and innovative applications─each with significant societal relevance. Together, they represent a global call-to-action for the scientific community.


  • Electrooxidation of CO on Platinum Nanoparticles Supported on NiO Thin Films

    by Aigerim Galyamova, Hyunwoo Ha, Graeme Henkelman, Richard M. Crooks


  • Open Access

    Ethanol Electrooxidation at 1–2 nm AuPd Nanoparticles

    by Juliette W. Strasser, Richard M. Crooks

    We report a systematic study of the electrocatalytic properties and stability of a series of 1–2 nm Au, Pd, and AuPd alloy nanoparticles (NPs) for the ethanol oxidation reaction (EOR). Following EOR electrocatalysis, NP sizes and compositions were characterized using aberration-corrected scanning transmission electron microscopy (ac-STEM) and energy dispersive spectroscopy (EDS). Two main findings emerge from this study. First, alloyed AuPd NPs exhibit enhanced electrocatalytic EOR activity compared to either monometallic Au or Pd NPs. Specifically, NPs having a 3:1 ratio of Au:Pd exhibit an ~8-fold increase in peak current density compared to Pd NPs, with an onset potential shifted ~200 mV more to the negative compared to Au NPs. Second, the size and composition of AuPd alloy NPs do not (within experimental error) change following 1.0 or 2.0 h chronoamperometry experiments, while monometallic Au NPs increase in size from 2 to 5 nm under the same conditions. Notably, this report demonstrates the importance of post-catalytic ac-STEM/EDS characterization for fully evaluating NP activity and stability, especially for 1–2 nm NPs that may change in size or structure during electrocatalysis.


  • Open Access

    Electrokinetic separation techniques for studying nano- and microplastics

    by Jonathan R. Thompson, Richard M. Crooks

    In recent years, microplastics have been found in seawater, soil, food, and even human blood and tissues. The ubiquity of microplastics is alarming, but the health and environmental impacts of microplastics are just beginning to be understood. Accordingly, sampling, separating, and quantifying exposure to microplastics to devise a total risk assessment is the focus of ongoing research. Unfortunately, traditional separation methods (i.e., size- and density-based methods) unintentionally exclude the smallest microplastics (<10 μm). Limited data about the smallest microplastics is problematic because they are likely the most pervasive and have distinct properties from their larger plastic counterparts. To that end, in this Perspective, we discuss using electrokinetic methods for separating the smallest microplastics. Specifically, we describe three methods for forming electric field gradients, discuss key results within the field for continuously separating microplastics, and lastly discuss research avenues which we deem critical for advancing electrokinetic separation platforms for targeting the smallest microplastics.


  • Open Access

    Enhanced electrocatalytic activity of Cu-modified, high-index single Pt NPs for formic acid oxidation

    by Ke Huang, Richard M. Crooks

    A key goal of nanoparticle-based catalysis research is to correlate the structure of nanoparticles (NPs) to their catalytic function. The most common approach for achieving this goal is to synthesize ensembles of NPs, characterize the ensemble, and then evaluate its catalytic properties. This approach is effective, but it excludes the certainty of structural heterogeneity in the NP ensemble. One means of addressing this shortcoming is to carry out analyses on individual NPs. This approach makes it possible to establish direct correlations between structures of single NPs and, in the case reported here, their electrocatalytic properties. Accordingly, we report on enhanced electrocatalytic formic acid oxidation (FAO) activity using individual Cu-modified, high-indexed Pt NPs. The results show that the Cu-modified Pt NPs exhibit significantly higher currents for FAO than the Pt-only analogs. The increased activity is enabled by the Cu submonolayer on the highly stepped Pt surface, which enhances the direct FAO pathway but not the indirect pathway which proceeds via surface-absorbed CO*.


  • Open Access

    Paper Biosensor for the Detection of NT-proBNP Using Silver Nanodisks as Electrochemical Labels

    by Yi Peng, Nikhil Raj, Juliette W. Strasser, Richard M. Crooks

    We report on the use of silver nanodisks (AgNDs), having a diameter of 50 ± 8 nm and a thickness of 8 ± 2 nm, as electrochemical labels for the detection of a model metalloimmunoassay for the heart failure biomarker NT-proBNP. The detection method is based on an electrochemically activated galvanic exchange (GE) followed by the detection of Ag using anodic stripping voltammetry (ASV). The AgNDs labels are superior to Ag nanocubes and Ag nanospheres in terms of the dynamic range for both the model and NT-proBNP metalloimmunoassays. The linear dynamic range for the model composite is 1.5 to 30.0 pM AgNDs. When AgND labels are used for the NT-proBNP assay, the dynamic range is 0.03–4.0 nM NT-proBNP. The latter range fully overlaps the risk stratification range for heart failure from 53 pM to 590 pM. The performance improvement of the AgNDs is a result of the specific GE mechanism for nanodisks. Specifically, GE is complete across the face of the AgNDs, leaving behind an incompletely exchanged ring structure composed of both Ag and Au.


  • Single atoms and small clusters of atoms may accompany Au and Pd dendrimer-encapsulated nanoparticles

    by Juliette W. Strasser, Richard M. Crooks

    We report the presence of small clusters of atoms (2 or –OH) and the elemental composition of the DENs (Au or Pd). Second, dialysis can be used to remove the majority of SAs/SCs in cases where a high density of SAs/SCs are present. The foregoing conclusions provide insights into the mechanisms for Au and Pd DEN synthesis and stability. Ultimately, these results demonstrate the need for careful characterization of systems containing nanoparticles to ensure that SAs/SCs, which may be below the detection limit of most analytical methods, are taken into consideration (especially for catalysis experiments).


  • Plastic-based lateral flow immunoassay device for electrochemical detection of NT-proBNP

    by Nikhil Raj, Richard M. Crooks

    Here we report an easily fabricated, plastic-based lateral flow device for carrying out metalloimmunoassays. The device is called ocFlow to emphasize the open-channel design. We have shown that the ocFlow is capable of magnetic microbead (MμB)-based metalloimmunoassays for the detection of two types of immunoconjugates: a model composite (MC) and a sandwich immunoassay for the heart failure marker NT-proBNP. In both assays, Ag nanoparticles (AgNPs) were used as electrochemically detectable labels. NT-proBNP and MC concentrations as low as 750.0 pM and 10.0 pM, respectively, could be detected using the ocFlow device. Four key conclusions can be drawn from the results presented herein. First, immunoconjugates attached to the MμBs can be transported in the flow channel using combined hydrodynamic and capillary pressure passive pumping. Second, the ocFlow device is capable of on-chip storage, resolvation, and conjugate formation of both the MC and NT-proBNP composites. Third, electrochemical detection can be conducted on analytes suspended in serum by rinsing the electrodes with a wash buffer. Finally, and perhaps most significantly, the assay is quantitative and has a detection limit for NT-proBNP in the high picomolar range when the necessary reagents are stored on the device in a dry form.


  • Enriching Cations Using Electric Field Gradients Generated by Bipolar Electrodes in the Absence of Buffer

    by Jonathan R. Thompson, Richard M. Crooks

    We report that ionic current gradients and corresponding electric field gradients formed at bipolar electrodes are useful for enriching cations up to ∼350‐fold at specific locations in microfluidic devices. The enrichment mechanism is determined by collecting current data, measuring solution conductivity, and by performing pH indicator experiments. These data reveal the dynamic nature of the enrichment mechanism. Specifically, they show the complex relationship between the ionic current gradients formed at the bipolar electrode and the extent of cation enrichment. Finally, we demonstrate cation enrichment is possible in buffer‐free solutions containing up to 50.0 mM KCl. This finding is significant because it broadens the range of solutions in which membrane‐free, electrochemical separations using bipolar electrodes can be performed.


  • Open Access

    Detection Efficiency of Ag Nanoparticle Labels for a Heart Failure Marker Using Linear and Square-Wave Anodic Stripping Voltammetry

    by Nikhil Raj, Richard M. Crooks

    In this article, we compare linear sweep anodic stripping voltammetry (LASV) and square-wave anodic stripping voltammetry (SWASV) for detection of a nano metalloimmunoassay. Two separate immunoassays were examined: a model assay, based on interactions between antibodies, and a sandwich assay for the heart failure marker NT-proBNP. In both cases, one antibody is linked to a magnetic microbead, and one is linked to a spherical Ag nanoparticle label. Electrochemical detection is carried out on a paper device. The three analytical figures of merit studied were the precision of the measurements, the calibration sensitivity, and the limit of detection (LOD). For the NT-proBNP assay, the results show that after optimization of the pulse amplitude and frequency of the potential input for SWASV, the detection efficiency is substantially higher compared to LASV. Specifically, the calibration sensitivity increased by up to ~40 fold, the average coefficient of variation decreased by ~40%, and the (LOD) decreased to 300.0 pM. Finally, for a model immunoassay, a ~10-fold decrease in the LOD was observed for SWASV compared to LASV.