David E. Claridge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David E. Claridge has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Davide Ziviani
Ray W. Herrick Laboratories, School of Mechanical Engineering, Purdue University 1 , 177 S. Russell Street, West Lafayette, Indiana 47907-2099
3 shared publications Juan-Carlos Baltazar
3 shared publicationsMingsheng Liu
Architectural Engineering, University of Nebraska
3 shared publicationsSong Deng
Energy Systems Laboratory
3 shared publications- Amin Isazadeh2 shared publications
Charles Culp
2 shared publications
Latest Publications
- Open Access
- 27 June 2026
- Published by Elsevier in SSRN Electronic Journal
Closed-Form and Reduced-Order Solutions for Transient Heat Conduction in a Solid Slab with Prescribed Heat-Flux/Convection Boundary Conditions and a Unified Variable-Thickness Framework
This study develops a unified analytical framework for transient one-dimensional heat conduction in a source-free, constant-property solid slab subjected to a prescribed heat flux at one boundary and convection at the opposite boundary, with an extension to a prescribed variable slab thickness. For the fixed-thickness baseline problem, exact dimensional and nondimensional solutions are derived through steady-transient decomposition and eigenfunction expansion under mixed boundary conditions. The nondimensional formulation reveals the governing roles of the Fourier and Biot numbers and reconstructs the dimensional temperature field exactly.Two variable-thickness extensions are then established. The first is a reduced-order frozen-geometry formulation that treats thickness evolution through interval-wise updates and consistent remapping between successive slab states. The second is an exact moving-boundary formulation obtained by transforming the governing equation from the evolving physical domain to a fixed computational coordinate. The fixed-thickness slab is recovered exactly as a limiting case when the thickness remains constant.Validation against the steady-state limit confirms exact recovery of the classical conduction-convection series thermal-resistance model. Illustrative studies verify dimensional-nondimensional consistency, demonstrate the thermal effect of prescribed thickness variation, and compare the reduced-order and exact moving-boundary formulations. In the nondimensional sensitivity analysis, increasing the Biot number from 0.02 to 10 decreases the steady nondimensional heated-wall response from 51 to 1.1 (about 97.8%) and the steady nondimensional fluid-solid-interface response from 50 to 0.1 (about 99.8%), while the normalized conductive temperature drop across the slab remains unchanged. The resulting framework provides a physically interpretable benchmark and a rapid analytical tool for variable-thickness thermal analysis.
- 27 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessClosed-Form and Reduced-Order Solutions for Transient Heat Conduction in a Solid Slab with Prescribed Heat-Flux/Convection Boundary Conditions and a Unified Variable-Thickness Framework
This study develops a unified analytical framework for transient one-dimensional heat conduction in a source-free, constant-property solid slab subjected to a prescribed heat flux at one boundary and convection at the opposite boundary, with an extension to a prescribed variable slab thickness. For the fixed-thickness baseline problem, exact dimensional and nondimensional solutions are derived through steady-transient decomposition and eigenfunction expansion under mixed boundary conditions. The nondimensional formulation reveals the governing roles of the Fourier and Biot numbers and reconstructs the dimensional temperature field exactly.Two variable-thickness extensions are then established. The first is a reduced-order frozen-geometry formulation that treats thickness evolution through interval-wise updates and consistent remapping between successive slab states. The second is an exact moving-boundary formulation obtained by transforming the governing equation from the evolving physical domain to a fixed computational coordinate. The fixed-thickness slab is recovered exactly as a limiting case when the thickness remains constant.Validation against the steady-state limit confirms exact recovery of the classical conduction-convection series thermal-resistance model. Illustrative studies verify dimensional-nondimensional consistency, demonstrate the thermal effect of prescribed thickness variation, and compare the reduced-order and exact moving-boundary formulations. In the nondimensional sensitivity analysis, increasing the Biot number from 0.02 to 10 decreases the steady nondimensional heated-wall response from 51 to 1.1 (about 97.8%) and the steady nondimensional fluid-solid-interface response from 50 to 0.1 (about 99.8%), while the normalized conductive temperature drop across the slab remains unchanged. The resulting framework provides a physically interpretable benchmark and a rapid analytical tool for variable-thickness thermal analysis.
- Open Access
- 11 November 2024
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 31 (1) , 1-17
Exploring the theoretical minimum energy use in the U.S. office building sector
- 11 November 2024
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 31 (1) , 1-17
Open AccessExploring the theoretical minimum energy use in the U.S. office building sector
- 7 September 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 187
Thermal management in legacy air-cooled data centers: An overview and perspectives
- 7 September 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 187
Thermal management in legacy air-cooled data centers: An overview and perspectives
- Top Cited Papers
- 6 January 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 174
Global trends, performance metrics, and energy reduction measures in datacom facilities
- 6 January 2023
- Published by Elsevier in Renewable and Sustainable Energy Reviews
- Vol. 174
Top Cited PapersGlobal trends, performance metrics, and energy reduction measures in datacom facilities
- 1 December 2021
- Published by Elsevier in Energy and Buildings
- Vol. 253, 111534
Occupancy analysis in commercial building cooling energy modelling with domestic water and electricity consumption
- 1 December 2021
- Published by Elsevier in Energy and Buildings
- Vol. 253, 111534
Occupancy analysis in commercial building cooling energy modelling with domestic water and electricity consumption
- 1 November 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 199, 111950
A simplified methodology to optimize the cooling tower approach temperature control schedule in a cooling system
- 1 November 2019
- Published by Elsevier in Energy Conversion and Management
- Vol. 199, 111950
A simplified methodology to optimize the cooling tower approach temperature control schedule in a cooling system
- 22 July 2007
- Published by Tech Science Press in Energy Engineering
- Vol. 104 (4) , 52-64
Continuous Commissioning® of A Large University Campus Domestic Hot Water System
Texas A&M University's central domestic hot water (DHW) system is a sub-system of the campus' 36.5 MW co-generation, and serves a total of more than 6 million square feet of dormitory, office, classroom, library, hotel, restaurant, and lab spaces in 68 campus buildings, being one of the largest of such systems. In the last five years, more and more students complained about “cold showers” in their dorms. Some temporary measures were taken, but could not solve the problems completely and were wasting energy. It brought the attention of the university's Physical Plant Department and Residence Life Department, which determined to completely resolve the issue. The Continuous Commissioning® (CC®) process was implemented. Previous to field actions, a much simplified hydraulic model was built to study the distribution system characteristics for the best direction of CC. The results show the building circulation flow will remain within an acceptable range while the loads vary, which demonstrates manual balancing is applicable. Following that, a system-wide survey with field measurements was conducted to establish the baseline. After analysis performed from a system point of view, a detailed plan was proposed and carried out during the Christmas break. Primary CC results are positive and as expected. Currently, fine-tuning and follow-up CC is still in progress, but it has turned into an obvious success of CC and team work.
- 22 July 2007
- Published by Tech Science Press in Energy Engineering
- Vol. 104 (4) , 52-64
Continuous Commissioning® of A Large University Campus Domestic Hot Water System
Texas A&M University's central domestic hot water (DHW) system is a sub-system of the campus' 36.5 MW co-generation, and serves a total of more than 6 million square feet of dormitory, office, classroom, library, hotel, restaurant, and lab spaces in 68 campus buildings, being one of the largest of such systems. In the last five years, more and more students complained about “cold showers” in their dorms. Some temporary measures were taken, but could not solve the problems completely and were wasting energy. It brought the attention of the university's Physical Plant Department and Residence Life Department, which determined to completely resolve the issue. The Continuous Commissioning® (CC®) process was implemented. Previous to field actions, a much simplified hydraulic model was built to study the distribution system characteristics for the best direction of CC. The results show the building circulation flow will remain within an acceptable range while the loads vary, which demonstrates manual balancing is applicable. Following that, a system-wide survey with field measurements was conducted to establish the baseline. After analysis performed from a system point of view, a detailed plan was proposed and carried out during the Christmas break. Primary CC results are positive and as expected. Currently, fine-tuning and follow-up CC is still in progress, but it has turned into an obvious success of CC and team work.
- 17 May 2006
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 30 (13) , 1075-1091
Missing data estimation for 1–6 h gaps in energy use and weather data using different statistical methods
Analysing hourly energy use to determine retrofit savings or diagnose system problems frequently requires rehabilitation of short periods of missing data. This paper evaluates four methods for rehabilitating short periods of missing data. Single variable regression, polynomial models, Lagrange interpolation, and linear interpolation models are developed, demonstrated, and used to fill 1–6 h gaps in weather data, heating data and cooling data for commercial buildings. The methodology for comparing the performance of the four different methods for filling data gaps uses 11 1-year data sets to develop different models and fill over 500 000 ‘pseudo-gaps’ 1–6 h in length for each model. These pseudo-gaps are created within each data set by assuming data is missing, then these gaps are filled and the ‘filled’ values compared with the measured values. Comparisons are made using four statistical parameters: mean bias error (MBE), root mean square error, sum of the absolute errors, and coefficient of variation of the sum of the absolute errors. Comparison based on frequency within specified error limits is also used. A linear interpolation model or a polynomial model with hour-of-day as the independent variable both fill 1–6 missing hours of cooling data, heating data or weather data, with accuracy clearly superior to the single variable linear regression model and to the Lagrange model. The linear interpolation model is the simplest and most convenient method, and generally showed superior performance to the polynomial model when evaluated using root mean square error, sum of the absolute errors, or frequency of filling within set error limits as criteria. The eighth-order polynomial model using time as the independent variable is a relatively simple, yet powerful approach that provided somewhat superior performance for filling heating data and cooling data if MBE is the criterion as is often the case when evaluating retrofit savings. Likewise, a tenth-order polynomial model provided the best performance when filling dew-point temperature data when MBE is the criterion. It is possible that the results would differ somewhat for other data sets, but the strength of the linear and polynomial models relative to the other models evaluated seems quite robust. Copyright © 2006 John Wiley & Sons, Ltd.
- 17 May 2006
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 30 (13) , 1075-1091
Missing data estimation for 1–6 h gaps in energy use and weather data using different statistical methods
Analysing hourly energy use to determine retrofit savings or diagnose system problems frequently requires rehabilitation of short periods of missing data. This paper evaluates four methods for rehabilitating short periods of missing data. Single variable regression, polynomial models, Lagrange interpolation, and linear interpolation models are developed, demonstrated, and used to fill 1–6 h gaps in weather data, heating data and cooling data for commercial buildings. The methodology for comparing the performance of the four different methods for filling data gaps uses 11 1-year data sets to develop different models and fill over 500 000 ‘pseudo-gaps’ 1–6 h in length for each model. These pseudo-gaps are created within each data set by assuming data is missing, then these gaps are filled and the ‘filled’ values compared with the measured values. Comparisons are made using four statistical parameters: mean bias error (MBE), root mean square error, sum of the absolute errors, and coefficient of variation of the sum of the absolute errors. Comparison based on frequency within specified error limits is also used. A linear interpolation model or a polynomial model with hour-of-day as the independent variable both fill 1–6 missing hours of cooling data, heating data or weather data, with accuracy clearly superior to the single variable linear regression model and to the Lagrange model. The linear interpolation model is the simplest and most convenient method, and generally showed superior performance to the polynomial model when evaluated using root mean square error, sum of the absolute errors, or frequency of filling within set error limits as criteria. The eighth-order polynomial model using time as the independent variable is a relatively simple, yet powerful approach that provided somewhat superior performance for filling heating data and cooling data if MBE is the criterion as is often the case when evaluating retrofit savings. Likewise, a tenth-order polynomial model provided the best performance when filling dew-point temperature data when MBE is the criterion. It is possible that the results would differ somewhat for other data sets, but the strength of the linear and polynomial models relative to the other models evaluated seems quite robust. Copyright © 2006 John Wiley & Sons, Ltd.