Shahab Ud Din
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shahab Ud Din has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Farooq Ahmad Chaudhary
School of Dentistry, Shaheed Zulfiqar Ali Bhutto Medical University, Islamabad, Pakistan
7 shared publications Mangala Patel
Centre for Oral Bioengineering (Dental Physical Sciences Unit), Bart’s and The London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
5 shared publications- Mohammad Khursheed Alam
Department of Preventive Dentistry, Jouf University, Sakakah, Saudi Arabia
4 shared publications Sandra Parker
Centre for Oral Bioengineering (Dental Physical Sciences Unit)
4 shared publicationsMichael Braden
Centre for Oral Bioengineering (Dental Physical Sciences Unit), Bart's and The London School of Medicine and Dentistry, Queen Mary University of London, UK
3 shared publications- Muhammad Qasim Javed
Department of Conservative Dental Sciences, College of Dentistry, Qassim University, Buraidah, Saudi Arabia
3 shared publications
Latest Publications
- Open Access
- 17 February 2023
- Published by MDPI AG in Healthcare
- Vol. 11 (4) , 606
Oral Health-Related Quality of Life in Patients with Chronic Oral Mucosal Diseases: Reliability and Validity of Urdu Version of Chronic Oral Mucosal Disease Questionnaire (COMDQ)
The aim of the study was to translate and validate the Urdu version of the Chronic Oral Mucosal Disease Questionnaire (COMDQ) and measure the oral health-related quality of life (OHRQoL) in Pakistani patients with chronic oral mucosal disease. One hundred and twenty patients with chronic oral mucosal diseases were recruited for this study. Two types of reliability of the COMDQ were tested. First, the internal consistency was calculated using Cronbach’s alpha, and second, test-retest reliability was calculated using intraclass correlation coefficients (ICC). Convergent validity was assessed for testing the validity of the COMDQ by examining the correlations with the Visual Analogue Scale (VAS) and OHIP-14 using Pearson’s correlations coefficient, and a t-test was used to compare the COMDQ domains and the socio-demographic characteristics. The most prevalent chronic oral mucosal disease (COMD) among the participants was recurrent aphthous stomatitis (47.5%), and the least prevalent was oral granulomatosis (6.6%). The total mean score for COMDQ was 43.5 (SD = 18.4). It showed a high level of internal consistency (Cronbach’s a = 0.81), and test-retest reliability was also good (r = 0.85). The total score of COMDQ was strongly correlated with the total score of OHIP-14 and VAS (r = 0.86 and r = 0.83), which indicated good convergent validity. The score of pain and the functional limitation domain reported a significant difference with age (p < 0.021) and employment status (p < 0.034). The Urdu version of COMDQ is an accurate, valid, and reliable instrument that can be used to assess the OHRQoL in patients with chronic oral mucosal diseases in Pakistani and other Urdu-speaking populations of different age groups.
- 17 February 2023
- Published by MDPI AG in Healthcare
- Vol. 11 (4) , 606
Open AccessOral Health-Related Quality of Life in Patients with Chronic Oral Mucosal Diseases: Reliability and Validity of Urdu Version of Chronic Oral Mucosal Disease Questionnaire (COMDQ)
The aim of the study was to translate and validate the Urdu version of the Chronic Oral Mucosal Disease Questionnaire (COMDQ) and measure the oral health-related quality of life (OHRQoL) in Pakistani patients with chronic oral mucosal disease. One hundred and twenty patients with chronic oral mucosal diseases were recruited for this study. Two types of reliability of the COMDQ were tested. First, the internal consistency was calculated using Cronbach’s alpha, and second, test-retest reliability was calculated using intraclass correlation coefficients (ICC). Convergent validity was assessed for testing the validity of the COMDQ by examining the correlations with the Visual Analogue Scale (VAS) and OHIP-14 using Pearson’s correlations coefficient, and a t-test was used to compare the COMDQ domains and the socio-demographic characteristics. The most prevalent chronic oral mucosal disease (COMD) among the participants was recurrent aphthous stomatitis (47.5%), and the least prevalent was oral granulomatosis (6.6%). The total mean score for COMDQ was 43.5 (SD = 18.4). It showed a high level of internal consistency (Cronbach’s a = 0.81), and test-retest reliability was also good (r = 0.85). The total score of COMDQ was strongly correlated with the total score of OHIP-14 and VAS (r = 0.86 and r = 0.83), which indicated good convergent validity. The score of pain and the functional limitation domain reported a significant difference with age (p < 0.021) and employment status (p < 0.034). The Urdu version of COMDQ is an accurate, valid, and reliable instrument that can be used to assess the OHRQoL in patients with chronic oral mucosal diseases in Pakistani and other Urdu-speaking populations of different age groups.
- Open Access
Reproduction of Fine Details and Compatibility of Vinyl Polysiloxane Impression Materials
The purpose of this study was to develop novel experimental (Exp) vinyl polysiloxane (VPS) impression materials (ab initio) and to evaluate their reproduction of fine details and compatibility with pouring materials. The Exp materials were compared with three commercial VPSs (Aquasil Ultra Monophase (Aq M), Extrude Medium-Bodied (Extr M), Elite HD Monophase (Elt M)) under dry, moist and wet conditions. Five VPSs (Exp-I–V) were developed, out of which Exp-I and II were hydrophobic while Exp-III, IV and V were hydrophilic. In the current study, Exp-II is the control for Exp-III, IV and V. Exp-I was the control for Exp-II, in which tear strength of the VPS was improved by adding a novel cross-linking agent. This part of the study has already been published by the authors. Under dry conditions, all commercial and Exp materials reproduced the 20 µm line satisfactorily. Under moist conditions, all commercial and some of the Exp (III, IV and V) materials reproduced the 20 µm line satisfactorily, with the exception of Exp-I and II. Under wet conditions, Aq M, Extr M and Exp-IV and V reproduced the continuous line, while Elt M and Exp-I, II and III failed to produce the line. For compatibility, all commercial and Exp VPSs, under dry conditions, reproduced the 50 µm line on the cast. Under moist conditions, Elt M and Exp-I and II did not record the line, while Aq M, Extr M and Exp-III, IV and V reproduced this line. Under wet conditions, Aq M, Extr M and Exp-IV and V reproduced the continuous line of 50 µm, while Elt M and Exp-I, II and III failed to record this line. Performance of the materials depends on the type and amount of surfactant incorporated. These data provide useful knowledge for clinicians on recording and pouring impressions with greater accuracy of reproduction of fine details and compatibility with cast/die materials.
Open AccessReproduction of Fine Details and Compatibility of Vinyl Polysiloxane Impression Materials
The purpose of this study was to develop novel experimental (Exp) vinyl polysiloxane (VPS) impression materials (ab initio) and to evaluate their reproduction of fine details and compatibility with pouring materials. The Exp materials were compared with three commercial VPSs (Aquasil Ultra Monophase (Aq M), Extrude Medium-Bodied (Extr M), Elite HD Monophase (Elt M)) under dry, moist and wet conditions. Five VPSs (Exp-I–V) were developed, out of which Exp-I and II were hydrophobic while Exp-III, IV and V were hydrophilic. In the current study, Exp-II is the control for Exp-III, IV and V. Exp-I was the control for Exp-II, in which tear strength of the VPS was improved by adding a novel cross-linking agent. This part of the study has already been published by the authors. Under dry conditions, all commercial and Exp materials reproduced the 20 µm line satisfactorily. Under moist conditions, all commercial and some of the Exp (III, IV and V) materials reproduced the 20 µm line satisfactorily, with the exception of Exp-I and II. Under wet conditions, Aq M, Extr M and Exp-IV and V reproduced the continuous line, while Elt M and Exp-I, II and III failed to produce the line. For compatibility, all commercial and Exp VPSs, under dry conditions, reproduced the 50 µm line on the cast. Under moist conditions, Elt M and Exp-I and II did not record the line, while Aq M, Extr M and Exp-III, IV and V reproduced this line. Under wet conditions, Aq M, Extr M and Exp-IV and V reproduced the continuous line of 50 µm, while Elt M and Exp-I, II and III failed to record this line. Performance of the materials depends on the type and amount of surfactant incorporated. These data provide useful knowledge for clinicians on recording and pouring impressions with greater accuracy of reproduction of fine details and compatibility with cast/die materials.
- Open Access
Validation and Reliability Testing of the Child Oral Impacts on Daily Performances (C-OIDP): Cross-Cultural Adaptation and Psychometric Properties in Pakistani School-Going Children
Background: This study aimed to develop an Urdu version of Child-Oral Impact on Daily Performance (C-OIDP) and assess its reliability and validity for children’s oral health-related quality of life (OHRQoL) assessment in Pakistan. Methods: A total of 200 school-going children aged 11–14 were recruited from two public schools. For the adaptation process, the original English version of C-OIDP was translated into Urdu, reviewed by an expert committee, back-translated into Urdu, and then reviewed again by the same expert committee and pilot tested on 10 children. A clinical examination was carried out to record dental and gingival status followed by a face-to-face interview to measure oral health-related quality of life in children using C-OIDP-U. Reliability, internal consistency, construct and discriminant validity were assessed. Results: The Cronbach’s alpha for C-OIDP-U was 0.69, the mean C-OIDP-U score was 10.2 ± 8.1 and 77.3% of the children reported at least one oral impact. Eating (40.3%) and difficulty in cleaning mouth (38.7%) were the two most impacted daily performances. For construct validity, the associations were significant between the C-OIDP-U score and all subjective oral health measures (p < 0.001). For discriminant validity, a significant association was observed between the C-OIDP-U score and clinical oral variables, children with DMFT + dmft ≥ 1, Gingival index > 1 and having malocclusion reported a higher C-OIDP-U score when compared to their counterparts. Conclusion: This study showed that C-OIDP is a valid, reliable and efficient instrument of OHRQoL for use in Pakistani children.
Open AccessValidation and Reliability Testing of the Child Oral Impacts on Daily Performances (C-OIDP): Cross-Cultural Adaptation and Psychometric Properties in Pakistani School-Going Children
Background: This study aimed to develop an Urdu version of Child-Oral Impact on Daily Performance (C-OIDP) and assess its reliability and validity for children’s oral health-related quality of life (OHRQoL) assessment in Pakistan. Methods: A total of 200 school-going children aged 11–14 were recruited from two public schools. For the adaptation process, the original English version of C-OIDP was translated into Urdu, reviewed by an expert committee, back-translated into Urdu, and then reviewed again by the same expert committee and pilot tested on 10 children. A clinical examination was carried out to record dental and gingival status followed by a face-to-face interview to measure oral health-related quality of life in children using C-OIDP-U. Reliability, internal consistency, construct and discriminant validity were assessed. Results: The Cronbach’s alpha for C-OIDP-U was 0.69, the mean C-OIDP-U score was 10.2 ± 8.1 and 77.3% of the children reported at least one oral impact. Eating (40.3%) and difficulty in cleaning mouth (38.7%) were the two most impacted daily performances. For construct validity, the associations were significant between the C-OIDP-U score and all subjective oral health measures (p < 0.001). For discriminant validity, a significant association was observed between the C-OIDP-U score and clinical oral variables, children with DMFT + dmft ≥ 1, Gingival index > 1 and having malocclusion reported a higher C-OIDP-U score when compared to their counterparts. Conclusion: This study showed that C-OIDP is a valid, reliable and efficient instrument of OHRQoL for use in Pakistani children.
- Open Access
Physico-Mechanical Properties of Commercially Available Tissue Conditioner Modified with Synthesized Chitosan Oligosaccharide
This study aims to compare the hardness, sorption and solubility of commercially available tissue conditioner [TC] modified with chitosan [CS] and synthesized chitosan oligosaccharide [COS] in antifungal concentration. COS was synthesized by acid hydrolysis and characterized by FTIR and XRD. Experimental materials were formulated by incorporating each per gram of TC powder with effective antifungal concentration of chitosan 1.02 mg (Group 1: TC-CS) and 0.51 mg COS (Group 2: TC-COS). A commercially available TC was used as control (Group 0: CTC). Shore A hardness test was performed according to ASTM D 2240-05 (2010) standards on samples stored in dry environment, distilled water (DW) and artificial saliva (AS) at 37 °C (n = 5 per group). Percent weight changes (n = 5 per group) after storage in DW and AS was used to record sorption and solubility. One-way Anova with post hoc Tukey’s test was applied. FTIR and XRD confirmed low molecular weight and amorphous nature of COS. Experimental groups had higher Shore A hardness values; however, these changes were not significant. Greatest variations in durometer values (p ≤ 0.05) were observed during the first 24 h. Experimental groups had higher (p ≤ 0.05) percentage sorption and solubility. Samples stored in DW had significantly higher (p = 0.019) sorption, whereas material had higher (p = 0.005) solubility in AS. Mean solubility values in both immersion mediums was highest for Group 2, followed by group 1 and group 0. In addition, significant (p ≤ 0.05) increase in solubility upon aging was noted for each material. Experimental tissue conditioner had higher hardness, sorption and solubility. However, these changes are not substantial to interfere with their tissue healing property. Therefore, these materials may be considered and explored further as potential antimicrobial drug delivery agent for denture stomatitis patients.
Open AccessPhysico-Mechanical Properties of Commercially Available Tissue Conditioner Modified with Synthesized Chitosan Oligosaccharide
This study aims to compare the hardness, sorption and solubility of commercially available tissue conditioner [TC] modified with chitosan [CS] and synthesized chitosan oligosaccharide [COS] in antifungal concentration. COS was synthesized by acid hydrolysis and characterized by FTIR and XRD. Experimental materials were formulated by incorporating each per gram of TC powder with effective antifungal concentration of chitosan 1.02 mg (Group 1: TC-CS) and 0.51 mg COS (Group 2: TC-COS). A commercially available TC was used as control (Group 0: CTC). Shore A hardness test was performed according to ASTM D 2240-05 (2010) standards on samples stored in dry environment, distilled water (DW) and artificial saliva (AS) at 37 °C (n = 5 per group). Percent weight changes (n = 5 per group) after storage in DW and AS was used to record sorption and solubility. One-way Anova with post hoc Tukey’s test was applied. FTIR and XRD confirmed low molecular weight and amorphous nature of COS. Experimental groups had higher Shore A hardness values; however, these changes were not significant. Greatest variations in durometer values (p ≤ 0.05) were observed during the first 24 h. Experimental groups had higher (p ≤ 0.05) percentage sorption and solubility. Samples stored in DW had significantly higher (p = 0.019) sorption, whereas material had higher (p = 0.005) solubility in AS. Mean solubility values in both immersion mediums was highest for Group 2, followed by group 1 and group 0. In addition, significant (p ≤ 0.05) increase in solubility upon aging was noted for each material. Experimental tissue conditioner had higher hardness, sorption and solubility. However, these changes are not substantial to interfere with their tissue healing property. Therefore, these materials may be considered and explored further as potential antimicrobial drug delivery agent for denture stomatitis patients.
- Open Access
Dimensional changes of commercial and novel polyvinyl siloxane impression materials following sodium hypochlorite disinfection
Background: Dental impressions are used to record anatomy of teeth and surrounding oral structures. Impression materials become contaminated with saliva and blood requiring disinfection, which may have negative impact on dimensional stability of materials. Objective: Comparatively evaluate linear dimensional changes of synthesized Tetra-functional (dimethylsilyl) orthosilicate (TFDMOS) containing Polyvinylsiloxane (PVS) impressions following sodium hypochlorite disinfection. Methods: Percentage dimensional changes of three commercial PVS (Elite HD Monophase, Extrude and Aquasil Ultra Monophase) and five experimental PVS impression materials were measured. Experimental material contained novel cross-linking agent (TFDMOS) and a non-ionic surfactant (Rhodasurf CET-2) that is Exp-A (without TFDMOS), Exp-B (with TFDMOS), Exp-C (TFDMOS+ 2% Rhodasurf CET-2), Exp-D (TFDMOS+ 2.5% Rhodasurf CET-2) Exp-E (TFDMOS+ 3% Rhodasurf CET-2). Samples were made using rectangular stainless-steel molds (40 × 10 × 3 mm3) and linear dimensional changes were measured using a calibrated travelling microscope at 10× magnification after immersion in distilled water (D.W) and 1% Sodium Hypochlorite solution at two different time intervals i.e., 30 min and 24 h. Results: Samples immersed in 1% NaOCl showed significant (p < 0.05) dimensional changes after 30 min of immersion. Exp-E showed significantly greater dimensional changes than their control (Exp-A and Exp-B). In distilled water, there were no significant difference among the tested materials. Aquasil exhibited highest expansion (0.06%) in both solutions. At 24 h, among the commercial materials, Extrude had the greatest expansion followed by Aquasil and Elite in DW while Aquasil showed the greatest expansion followed by Extrude and Elite in NaOCl. Conclusion: Experimental PVS had linear dimensional changes within the ISO 4823; 2015 recommended range. However, extended immersion can negatively affect the linear dimensions.
Open AccessDimensional changes of commercial and novel polyvinyl siloxane impression materials following sodium hypochlorite disinfection
Background: Dental impressions are used to record anatomy of teeth and surrounding oral structures. Impression materials become contaminated with saliva and blood requiring disinfection, which may have negative impact on dimensional stability of materials. Objective: Comparatively evaluate linear dimensional changes of synthesized Tetra-functional (dimethylsilyl) orthosilicate (TFDMOS) containing Polyvinylsiloxane (PVS) impressions following sodium hypochlorite disinfection. Methods: Percentage dimensional changes of three commercial PVS (Elite HD Monophase, Extrude and Aquasil Ultra Monophase) and five experimental PVS impression materials were measured. Experimental material contained novel cross-linking agent (TFDMOS) and a non-ionic surfactant (Rhodasurf CET-2) that is Exp-A (without TFDMOS), Exp-B (with TFDMOS), Exp-C (TFDMOS+ 2% Rhodasurf CET-2), Exp-D (TFDMOS+ 2.5% Rhodasurf CET-2) Exp-E (TFDMOS+ 3% Rhodasurf CET-2). Samples were made using rectangular stainless-steel molds (40 × 10 × 3 mm3) and linear dimensional changes were measured using a calibrated travelling microscope at 10× magnification after immersion in distilled water (D.W) and 1% Sodium Hypochlorite solution at two different time intervals i.e., 30 min and 24 h. Results: Samples immersed in 1% NaOCl showed significant (p < 0.05) dimensional changes after 30 min of immersion. Exp-E showed significantly greater dimensional changes than their control (Exp-A and Exp-B). In distilled water, there were no significant difference among the tested materials. Aquasil exhibited highest expansion (0.06%) in both solutions. At 24 h, among the commercial materials, Extrude had the greatest expansion followed by Aquasil and Elite in DW while Aquasil showed the greatest expansion followed by Extrude and Elite in NaOCl. Conclusion: Experimental PVS had linear dimensional changes within the ISO 4823; 2015 recommended range. However, extended immersion can negatively affect the linear dimensions.
- Open Access
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 4099071
Work‐Related Musculoskeletal Disorders and Their Associated Risk Factors among Pakistani Dental Practitioners: A Cross‐Sectional Study
Background. Work‐related musculoskeletal disorders (WMSDs) have a negative impact on quality of life, and dentists are at risk of WMSDs due to the nature of work being static, repetitious, and for a long duration. The study was aimed at measuring the prevalence and distribution of work‐related musculoskeletal disorders and determining the risk factors associated with affliction among Pakistani dentists. Methods. An online cross‐sectional survey was conducted using a validated questionnaire consisting of four sections. The first section had questions related to sociodemographic information, the second section had questions that assessed the intensity and frequency of musculoskeletal pain (MSP), third section questions were concerned with the effect of MSP on the respondents’ daily life, while the last section contained questions on whether they perceived their work in the dental clinic as a cause of their pain. Chi‐square and one‐way ANOVA tests were used for the analysis of the data in SPSS‐23. Results. A total of 600 completely filled questionnaires were received with a response rate of 76.4%, and about 87% of the dental practitioners had some sort of MSD. The intensity and frequency of WMSDs were statistically significant (p < 0.05) in association with all the sociodemographic characteristics. The lower back area was the most reported site of WMSD pain (51.3%) followed by the neck/upper back (21.3%) and shoulder (17.6%). The site of pain was statistically significant (p < 0.05) in association with all the sociodemographic characteristics except gender (p = 0.11). A majority of participants (95.4%) had sought medical treatment and taken sick leaves (70%) due to WMSDs pain during their life. Participants attributed a number of working years and working posture as the two main reasons behind WMSDs. Conclusion. Considering the high prevalence of WMSDs among dentists, preventive strategies that minimize the occurrence of WMSDs should be adopted by dental professionals. The impact of WMSDs can be reduced by maintaining good posture, taking breaks and rest in between work, doing regular exercise, and improving the work environment.
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 4099071
Open AccessWork‐Related Musculoskeletal Disorders and Their Associated Risk Factors among Pakistani Dental Practitioners: A Cross‐Sectional Study
Background. Work‐related musculoskeletal disorders (WMSDs) have a negative impact on quality of life, and dentists are at risk of WMSDs due to the nature of work being static, repetitious, and for a long duration. The study was aimed at measuring the prevalence and distribution of work‐related musculoskeletal disorders and determining the risk factors associated with affliction among Pakistani dentists. Methods. An online cross‐sectional survey was conducted using a validated questionnaire consisting of four sections. The first section had questions related to sociodemographic information, the second section had questions that assessed the intensity and frequency of musculoskeletal pain (MSP), third section questions were concerned with the effect of MSP on the respondents’ daily life, while the last section contained questions on whether they perceived their work in the dental clinic as a cause of their pain. Chi‐square and one‐way ANOVA tests were used for the analysis of the data in SPSS‐23. Results. A total of 600 completely filled questionnaires were received with a response rate of 76.4%, and about 87% of the dental practitioners had some sort of MSD. The intensity and frequency of WMSDs were statistically significant (p < 0.05) in association with all the sociodemographic characteristics. The lower back area was the most reported site of WMSD pain (51.3%) followed by the neck/upper back (21.3%) and shoulder (17.6%). The site of pain was statistically significant (p < 0.05) in association with all the sociodemographic characteristics except gender (p = 0.11). A majority of participants (95.4%) had sought medical treatment and taken sick leaves (70%) due to WMSDs pain during their life. Participants attributed a number of working years and working posture as the two main reasons behind WMSDs. Conclusion. Considering the high prevalence of WMSDs among dentists, preventive strategies that minimize the occurrence of WMSDs should be adopted by dental professionals. The impact of WMSDs can be reduced by maintaining good posture, taking breaks and rest in between work, doing regular exercise, and improving the work environment.
- Open Access
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 1703869
Comparison of the Hardness of Novel Experimental Vinyl Poly Siloxane (VPS) Impression Materials with Commercially Available Ones
Purpose. To determine the hardness and Young’s moduli of both commercial and experimental vinyl poly siloxane (VPS). Methods. The purpose of this study was to develop a medium‐bodied experimental (Exp‐I, II, III, IV, and V) VPS impression materials and to analyse their effects on hardness and Young’s modulus and compare them with three commercial VPS materials (Aquasil, Elite, and Extrude) using Shore A hardness tester. Measurements were recorded after 1, 24, 72, and 168 hours of mixing. The results were analysed with one‐way ANOVA and post hoc Tukey’s test using the SPSS PASW statistical 22 software. Results. Commercial and experimental vinyl polysiloxane exhibited higher Shore A hardness values with time (i.e., 1 hour after mixing, 24 hours after mixing, 72 hours after mixing, and 1 week after mixing). All Comml and Exp VPS demonstrated a significant increase (ANOVA, p < 0.05) in hardness at increasing time points. Generally, all commercial VPS exhibited significantly higher values for Shore A hardness compared to all Exp formulations. For commercial products, Elt M presented significantly highest values at all‐time points followed by Aq M then Extr M. Exp‐I was significantly harder than all other Exp VPS at all‐time points. Young’s modulus values were directly related to Shore A hardness; materials with higher Shore A hardness values had higher Young’s moduli. Conclusion. Continued polymerisation of elastomeric impression materials results in increased hardness over time. Hardness, Young’s moduli, and rigidity of the set commercial and experimental VPS materials were within the required limits. Shore A hardness and Young’s moduli were directly proportional to each other, and commercial and experimental materials had enough rigidity to contain the stone during pouring.
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 1703869
Open AccessComparison of the Hardness of Novel Experimental Vinyl Poly Siloxane (VPS) Impression Materials with Commercially Available Ones
Purpose. To determine the hardness and Young’s moduli of both commercial and experimental vinyl poly siloxane (VPS). Methods. The purpose of this study was to develop a medium‐bodied experimental (Exp‐I, II, III, IV, and V) VPS impression materials and to analyse their effects on hardness and Young’s modulus and compare them with three commercial VPS materials (Aquasil, Elite, and Extrude) using Shore A hardness tester. Measurements were recorded after 1, 24, 72, and 168 hours of mixing. The results were analysed with one‐way ANOVA and post hoc Tukey’s test using the SPSS PASW statistical 22 software. Results. Commercial and experimental vinyl polysiloxane exhibited higher Shore A hardness values with time (i.e., 1 hour after mixing, 24 hours after mixing, 72 hours after mixing, and 1 week after mixing). All Comml and Exp VPS demonstrated a significant increase (ANOVA, p < 0.05) in hardness at increasing time points. Generally, all commercial VPS exhibited significantly higher values for Shore A hardness compared to all Exp formulations. For commercial products, Elt M presented significantly highest values at all‐time points followed by Aq M then Extr M. Exp‐I was significantly harder than all other Exp VPS at all‐time points. Young’s modulus values were directly related to Shore A hardness; materials with higher Shore A hardness values had higher Young’s moduli. Conclusion. Continued polymerisation of elastomeric impression materials results in increased hardness over time. Hardness, Young’s moduli, and rigidity of the set commercial and experimental VPS materials were within the required limits. Shore A hardness and Young’s moduli were directly proportional to each other, and commercial and experimental materials had enough rigidity to contain the stone during pouring.
- 1 June 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (6) , 1054-1065
Improved water absorption behaviour of experimental hydrophilic vinyl polysiloxane (VPS) impression materials incorporating a crosslinking agent and a novel surfactant
- 1 June 2021
- Published by Elsevier in Dental Materials
- Vol. 37 (6) , 1054-1065
Improved water absorption behaviour of experimental hydrophilic vinyl polysiloxane (VPS) impression materials incorporating a crosslinking agent and a novel surfactant
- 13 May 2020
- Published by Wiley in International Journal of Developmental Neuroscience
- Vol. 80 (5) , 380-388
Sequence variants in three genes underlying leukodystrophy in Pakistani families
Leukodystrophies (LDs) are a heterogeneous group of rare and progressive genetic diseases that affect brain, spinal cord and often the peripheral nerves. They are characterized by abnormal development or destruction of the myelin sheath of the brain. This study was aimed to search for the causative variants in three unrelated consanguineous families presented with LD. Detailed clinical investigations were carried out on probands in three unrelated consanguineous families of Pakistani origin. Targeted gene sequencing and Whole Exome Sequencing (WES) were performed for variant identification. Candidate variants were checked for co‐segregation with the phenotype using Sanger sequencing. Public databases including ExAC, gnomAD, dbSNP and the 1,000 Genome Project were searched to determine frequencies of the alleles. Conservation of the missense variants was ensured by aligning orthologous protein sequences from diverse vertebrate species. Targeted gene sequencing identified a novel homozygous missense mutation [c.2135G>A, p.(Arg712His) in the ATP Binding Cassette Subfamily D Member 1 (ABCD1; OMIM# 300371) in three affected siblings in family A.WES followed by validation by Sanger sequencing revealed previously reported homozygous missense variants [c.162C>A; p.(Asn54Lys)] in ASPA (OMIM# 608034) in family B and [c.361G>C,p.(Gly121Arg)] in ARSA (OMIM# 607574) in family C. Investigation of three families underlies importance of WES as an amazing diagnostic tool for conclusive determination of a specific type of LD. Further, the study would assist in carrier testing and prenatal diagnosis of the affected families. In addition, searching for common variants in the genes causing LD would help in designing low‐cost targeted variation testing in patients.
- 13 May 2020
- Published by Wiley in International Journal of Developmental Neuroscience
- Vol. 80 (5) , 380-388
Sequence variants in three genes underlying leukodystrophy in Pakistani families
Leukodystrophies (LDs) are a heterogeneous group of rare and progressive genetic diseases that affect brain, spinal cord and often the peripheral nerves. They are characterized by abnormal development or destruction of the myelin sheath of the brain. This study was aimed to search for the causative variants in three unrelated consanguineous families presented with LD. Detailed clinical investigations were carried out on probands in three unrelated consanguineous families of Pakistani origin. Targeted gene sequencing and Whole Exome Sequencing (WES) were performed for variant identification. Candidate variants were checked for co‐segregation with the phenotype using Sanger sequencing. Public databases including ExAC, gnomAD, dbSNP and the 1,000 Genome Project were searched to determine frequencies of the alleles. Conservation of the missense variants was ensured by aligning orthologous protein sequences from diverse vertebrate species. Targeted gene sequencing identified a novel homozygous missense mutation [c.2135G>A, p.(Arg712His) in the ATP Binding Cassette Subfamily D Member 1 (ABCD1; OMIM# 300371) in three affected siblings in family A.WES followed by validation by Sanger sequencing revealed previously reported homozygous missense variants [c.162C>A; p.(Asn54Lys)] in ASPA (OMIM# 608034) in family B and [c.361G>C,p.(Gly121Arg)] in ARSA (OMIM# 607574) in family C. Investigation of three families underlies importance of WES as an amazing diagnostic tool for conclusive determination of a specific type of LD. Further, the study would assist in carrier testing and prenatal diagnosis of the affected families. In addition, searching for common variants in the genes causing LD would help in designing low‐cost targeted variation testing in patients.
- Open Access
- 1 December 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (12) , e334-e343
The effects of cross-linking agent and surfactant on the tear strength of novel vinyl polysiloxane impression materials
- 1 December 2018
- Published by Elsevier in Dental Materials
- Vol. 34 (12) , e334-e343
Open AccessThe effects of cross-linking agent and surfactant on the tear strength of novel vinyl polysiloxane impression materials