JMJun Miyazaki

Jun Miyazaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jun Miyazaki has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Ryotaro Wagatsuma

    Faculty of Systems Engineering, Wakayama University, Wakayama, Japan

    2 shared publications
  • Eunok Lee

    Department of Research Planning National Institute of Ecology Chungcheongnam‐do 33657 Republic of Korea

    1 shared publication
  • Hang Lee

    Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University, Seoul, Republic of Korea

    1 shared publication
  • Haruki Nakabayashi

    Faculty of Systems Engineering, Wakayama University, 930 Sakae-dani, Wakayama 640-8510, Japan

    1 shared publication
  • Honoka Maeda

    Faculty of Systems Engineering, Wakayama University, 930 Sakae-dani, Wakayama 640-8510, Japan

    1 shared publication
  • Koji Okamoto

    Graduate School of Frontier Biosciences, Osaka University, Osaka 565-0871, Japan

    1 shared publication

Latest Publications

  • Dual-probe photothermal microscopy for suppression of side-lobe artifacts

    by Jun Miyazaki, Riku Ikeya

    Photothermal microscopy enables high-sensitivity imaging of light-absorbing molecules; however, conventional implementations suffer from axial side-lobe artifacts that degrade accurate observation of three-dimensional structures. This study introduces a dual-probe photothermal microscopy approach that combines two probes at distinct axial positions with polarization–space-division balanced detection to suppress these artifacts without compromising probe power. Experiments using gold nanoparticles revealed that the side-lobe-to-main-lobe ratio decreased from 0.18 in conventional detection to 0.032 with the proposed method. Cross-sectional imaging of cedar pollen further demonstrated substantial suppression of spurious signals. This approach is compatible with dynamic specimens and extends the capability of photothermal microscopy for precise structural analysis.

  • Label-Free Imaging of Lysosomes in Living Cells by Photothermal Microscopy

    by Jun Miyazaki, Ryotaro Wagatsuma

    Photothermal microscopy is an optical imaging technique used to visualize the distribution of trace amounts of endogenous dyes in living cells. This technique facilitates lysosomal observation and functional analysis by detecting and identifying accumulated substances within them, eliminating the need for molecular labeling. Here, we describe the fundamental principles and system configuration of a photothermal microscope. We also present a detailed procedure for performing photothermal measurements in living cells.

  • Open Access

    Photothermal imaging of cellular responses to glucose deprivation

    by Jun Miyazaki, Ryotaro Wagatsuma, Koji Okamoto

    Cellular responses to glucose deprivation in live cancer cells were visualised using multi-wavelength photothermal microscopy without the use of labelling molecules.


  • Open Access

    Polydopamine-Coated Solid Silica Nanoparticles Encapsulating IR-783 Dyes: Synthesis and NIR Fluorescent Cell Imaging

    by Yoshio Nakahara, Haruki Nakabayashi, Jun Miyazaki, Mitsuru Watanabe, Toshiyuki Tamai, Setsuko Yajima

    We report a simple and efficient synthetic method for polydopamine (PDA)-coated solid silica nanoparticles (s-SiO2@PDA NPs) encapsulating anionic near-infrared (NIR) fluorescent dyes through physical adsorption. Despite the use of anionic NIR fluorescent dyes indocyanine green (ICG) and 2-[2-[2-chloro-3-[2-[1,3-dihydro-3,3-dimethyl-1-(4-sulfobutyl)-2H-indol-2-ylidene]-ethylidene]-1-cyclohexen-1-yl]-ethenyl]-3,3-dimethyl-1-(4-sulfobutyl)-3H-indolium (IR-783), they were successfully immobilized on anionic s-SiO2@PDA NP surfaces under acidic aqueous conditions. After embedding in the s-SiO2@PDA NPs, the fluorescence of ICG was almost quenched, while a diminished IR-783 fluorescence remained observable. The fluorescence intensity of IR-783 embedded in s-SiO2@PDA NPs remained almost constant over 2 weeks in a pseudobiological solution, with a slight reduction due to dye degradation and dye leakage from the s-SiO2@PDA NPs. Finally, the s-SiO2@PDA NPs encapsulating IR-783 were successfully used for NIR fluorescent imaging of African green monkey kidney cells.


  • Discrimination of individual semiconducting and metallic single-walled carbon nanotubes by multi-wavelength photothermal microscopy

    by Jun Miyazaki, Honoka Maeda

    The coexistence of semiconducting and metallic single-walled carbon nanotubes (SWCNTs) after synthesis is one of the factors preventing their practical applications. A method for quantifying the purity of a nanotube sample with high accuracy is essential because each type has different applications. In this study, we investigated the accuracy in distinguishing between semiconducting and metallic SWCNTs using multi-wavelength photothermal microscopy. Linear discrimination analysis of the multi-wavelength signals of individual nanotubes was performed to show that the two types of SWCNTs could be distinguished with more than ∼95% accuracy when the SWCNTs were embedded in a dry polymer film. In contrast, the discrimination rate decreased to about 80% when the SWCNTs were dispersed in aqueous media. The optimal wavelength combinations, number of lasers required for discrimination, and relationship between the signal-to-noise ratio and discrimination rate are also discussed.


  • Multiwavelength Photothermal Imaging of Individual Single-Walled Carbon Nanotubes Suspended in a Solvent

    by Jun Miyazaki, Yuya Ishikawa, Ryosuke Kondo

    Optical imaging of individual single-walled carbon nanotubes (SWCNTs) enables the characterization of heterogeneous SWCNT samples. However, previous measurement methods have targeted SWCNTs fixed on a substrate. In this study, absorption-contrast imaging of individual SWCNTs moving irregularly in a solvent was performed by simultaneous multiwavelength photothermal (PT) microscopy. Using this technique, heterogeneous samples containing semiconducting and metallic SWCNTs were characterized by absorption spectroscopy. The semiconducting and metallic SWCNTs were visualized in different colors in the obtained multiwavelength images due to their different absorption spectra. Statistical analysis of the multiwavelength signals revealed that semiconducting and metallic SWCNTs could be distinguished with more than 90% accuracy. Time-series PT imaging of the nanotube aggregates induced by salt addition was also conducted by performing single-nanotube measurements. Our study demonstrated that PT microscopy is a versatile technique for determining the composition and degree of aggregation of SWCNTs in liquid and polymeric media, which can promote the industrial application of such materials.


  • Label-free dynamic imaging of mitochondria and lysosomes within living cells via simultaneous dual-pump photothermal microscopy

    by Jun Miyazaki, Yasunobu Toumon

    The dynamic activities of mitochondria and lysosomes, which play important roles in maintaining cellular homeostasis, were observed without labeling by using highly sensitive photothermal (PT) microscopy. This imaging modality allows for the direct observation of cellular organelles that contain endogenous chromophores, with high temporal and spatial resolution. We identified mitochondria and lysosomes inside living mammalian cells via simultaneous dual-color imaging. Moreover, dynamic imaging revealed that the lysosomes make contact with mitochondria and move between sites within the dynamic mitochondrial network. Since mitochondrial and lysosomal functions are intricately connected, PT microscopy should provide in-depth understanding of cellular functions associated with mitochondria–lysosome communication as well as insights into various human diseases caused by dysfunction of these organelles.


  • Open Access

    Photothermal Microscopy for High Sensitivity and High Resolution Absorption Contrast Imaging of Biological Tissues

    by Jun Miyazaki, Takayoshi Kobayahsi

    Photothermal microscopy is useful to visualize the distribution of non-fluorescence chromoproteins in biological specimens. Here, we developed a high sensitivity and high resolution photothermal microscopy with low-cost and compact laser diodes as light sources. A new detection scheme for improving signal to noise ratio more than 4-fold is presented. It is demonstrated that spatial resolution in photothermal microscopy is up to nearly twice as high as that in the conventional widefield microscopy. Furthermore, we demonstrated the ability for distinguishing or identifying biological molecules with simultaneous muti-wavelength imaging. Simultaneous photothermal and fluorescence imaging of mouse brain tissue was conducted to visualize both neurons expressing yellow fluorescent protein and endogenous non-fluorescent chromophores.


  • The Weak Iridescent Feather Color in the Jungle CrowCorvus macrorhynchos

    by Eunok Lee, Jun Miyazaki, Shinya Yoshioka, Hang Lee, Shoei Sugita

    We investigated the origin of the iridescent violet-bluish feathers of the adult Jungle Crow, Corvus macrorhynchos, using microscopic and optical techniques. A single layer of melanin granules was found below the surface of the barbules in the feathers of male crows. Although the barbule microstructure was clearly sexually dimorphic, neither the appearance nor the optical measurements were notably different between the sexes, which indicated that the single layer of melanin granules did not contribute to the iridescent color of the feathers. We also found a thin layer, which we refer to as the epicuticle, at the surfaces of the barbules of both male and female feathers, indicating thin-film interference as the most likely cause of the iridescent color. We investigated this possibility by measuring reflection patterns and spectra. Our results suggest that the weak violet-bluish feather color of the feathers of the Jungle Crow is caused by thin-film interface due to the presence of an epicuticle on the feather barbules.