Fátima Rodrigues
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fátima Rodrigues has a total of 341 co-authors. Here are the top co-authors by number of shared publications:
- Cristina Bárbara
Chest Department, Centro Hospitalar Lisboa Norte, Lisbon, Portugal; Environmental Health Institute (ISAMB), Faculty of Medicine, University of Lisbon, Portugal
9 shared publications - Joana Cruz
Center for Innovative Care and Health Technology (ciTechCare), Polytechnic of Leiria, Leiria; School of Health Sciences, Polytechnic of Leiria, Leiria, Portugal
4 shared publications - Alda Marques
University of Aveiro
3 shared publications - Ana Luísa Papoila
Epidemiology and Statistics Unit, Research Center, Unidade Local de Saúde São José, Centro Clínico Académico de Lisboa, Lisbon, Portugal
3 shared publications - Ana Martins
Pulmonary Rehabilitation Unit, Thoracic Department, Santa Maria Local Health Unit, Lisboa, Portugal
3 shared publications - Catarina Duarte Santos
Instituto de Saúde Ambiental (ISAMB), Faculdade de Medicina, Universidade de Lisboa; Unidade de Reabilitação Respiratória, Hospital Pulido Valente, Centro Hospitalar Universitário Lisboa Norte, Lisboa, Portugal
3 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 264
Awareness without actionable knowledge: understanding physical activity recommendations among people with COPD
- 27 October 2026
- Published by Elsevier in Respiratory Medicine
- Vol. 264
Open AccessAwareness without actionable knowledge: understanding physical activity recommendations among people with COPD
- 12 October 2026
- Published by Springer Nature in Sleep and Breathing
- Vol. 30 (6) , 286
Measuring adult breathing pattern: devices, outcomes, and evidence—a scoping review
- 12 October 2026
- Published by Springer Nature in Sleep and Breathing
- Vol. 30 (6) , 286
Measuring adult breathing pattern: devices, outcomes, and evidence—a scoping review
- Open Access
- 1 October 2026
- Published by Ordem dos Medicos in Acta Medica Portuguesa
- Vol. 39 (10) , 630-634
Impacto de um Modelo Integrado de Cuidados em Doentes com DPOC e Risco Elevado de Reinternamento
A doença pulmonar obstrutiva crónica (DPOC) está associada a elevada morbilidade e utilização de serviços de saúde, particularmente na sequência de exacerbações agudas que levam ao serviço de urgência (SU) e internamentos hospitalares. Doentes com comorbilidades e vulnerabilidade social apresentam maior risco de reinternamento. Este estudo teve como objetivo avaliar o impacto de uma intervenção precoce com um plano individual e integrado de cuidados (PIC) na redução de deslocações ao SU e internamentos em doentes com DPOC de alto risco. O protocolo Avaliação Pneumológica Precoce/Plano Individual de Cuidados (APP/PIC) foi implementado em fevereiro de 2024. Os doentes com risco elevado foram identificados através do cálculo do índice LACE (> 9 pontos ou 5 – 9 na presença de fatores adicionais). A intervenção combinou avaliação médica, enfermagem e serviço social, através de um modelo de seguimento híbrido, presencial e remoto. Os principais dados avaliados foram o número de idas ao SU e internamentos hospitalares no ano anterior e posterior à instituição do protocolo. Foi utilizado o teste t de Student emparelhado para a análise. Foram incluídos 53 doentes (média de idade de 67,6 anos; 62% do sexo masculino). A média do índice de comorbilidades de Charlson foi de 4,5 pontos e do índice LACE 13,8 pontos. Um ano depois, o número médio de idas ao SU reduziu de 3,09 para 0,067 (p < 0,001), e o número de internamentos, de 1,39 para 0,33 (p < 0,001). O seguimento remoto gerou alertas clínicos que resultaram em consultas médicas e de enfermagem, tendo apenas dois casos necessitado de encaminhamento ao SU e internamento por insuficiência respiratória grave. A intervenção social permitiu que a maioria dos doentes mantivesse ou retomasse apoio domiciliário. O protocolo APP/PIC demonstrou eficácia na redução de idas ao SU e internamentos em doentes com DPOC de alto risco. Este modelo representa uma abordagem promissora e sustentável para a gestão integrada de doenças respiratórias crónicas.
- 1 October 2026
- Published by Ordem dos Medicos in Acta Medica Portuguesa
- Vol. 39 (10) , 630-634
Open AccessImpacto de um Modelo Integrado de Cuidados em Doentes com DPOC e Risco Elevado de Reinternamento
A doença pulmonar obstrutiva crónica (DPOC) está associada a elevada morbilidade e utilização de serviços de saúde, particularmente na sequência de exacerbações agudas que levam ao serviço de urgência (SU) e internamentos hospitalares. Doentes com comorbilidades e vulnerabilidade social apresentam maior risco de reinternamento. Este estudo teve como objetivo avaliar o impacto de uma intervenção precoce com um plano individual e integrado de cuidados (PIC) na redução de deslocações ao SU e internamentos em doentes com DPOC de alto risco. O protocolo Avaliação Pneumológica Precoce/Plano Individual de Cuidados (APP/PIC) foi implementado em fevereiro de 2024. Os doentes com risco elevado foram identificados através do cálculo do índice LACE (> 9 pontos ou 5 – 9 na presença de fatores adicionais). A intervenção combinou avaliação médica, enfermagem e serviço social, através de um modelo de seguimento híbrido, presencial e remoto. Os principais dados avaliados foram o número de idas ao SU e internamentos hospitalares no ano anterior e posterior à instituição do protocolo. Foi utilizado o teste t de Student emparelhado para a análise. Foram incluídos 53 doentes (média de idade de 67,6 anos; 62% do sexo masculino). A média do índice de comorbilidades de Charlson foi de 4,5 pontos e do índice LACE 13,8 pontos. Um ano depois, o número médio de idas ao SU reduziu de 3,09 para 0,067 (p < 0,001), e o número de internamentos, de 1,39 para 0,33 (p < 0,001). O seguimento remoto gerou alertas clínicos que resultaram em consultas médicas e de enfermagem, tendo apenas dois casos necessitado de encaminhamento ao SU e internamento por insuficiência respiratória grave. A intervenção social permitiu que a maioria dos doentes mantivesse ou retomasse apoio domiciliário. O protocolo APP/PIC demonstrou eficácia na redução de idas ao SU e internamentos em doentes com DPOC de alto risco. Este modelo representa uma abordagem promissora e sustentável para a gestão integrada de doenças respiratórias crónicas.
- Open Access
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (19) , 29686-29705
Validation of a Dorsal-Referenced IMU Framework for Thoracoabdominal Respiratory Motion Sensing and Frequency Estimation
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (19) , 29686-29705
Open AccessValidation of a Dorsal-Referenced IMU Framework for Thoracoabdominal Respiratory Motion Sensing and Frequency Estimation
- Open Access
- 13 July 2025
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 12 (1) , e002355
Concordance between FVC and FEV 6 for identifying chronic airflow obstruction and spirometric restriction in the Burden of Obstructive Lung Disease (BOLD) study
Introduction: We investigated whether the forced expiratory volume in 6 s (FEV 6 ) can be used as a surrogate for the forced vital capacity (FVC). Methods: The Burden of Obstructive Lung Disease is a multinational cohort study. At baseline, data were collected from adults, aged 40 years or older, from 41 sites across 34 countries. Participants from 18 sites were followed-up after a median of 8.3 years. Participants who completed the study core questionnaire and had acceptable post-bronchodilator spirometry were included. We performed receiver operating characteristic analyses to measure the ability of FEV 1 /FEV 6 less than the lower limit of normal (LLN) to correctly classify FEV 1 /FVC less than the LLN, and FEV 6 less than the LLN to correctly classify FVC less than the LLN. We used multilevel regression analyses to assess the association of discordant measurements with respiratory symptoms, quality of life and lung function decline. Results: At baseline, 28 604 participants were included. 53% were female (15 060). 10% (2876) had chronic airflow obstruction for FEV 1 /FVC, compared with 9% (2704) for FEV 1 /FEV 6 . 37% (10 637) had spirometric restriction for FVC, compared with 35% (9978) for FEV 6 . The FEV 1 /FEV 6 had excellent accuracy in identifying FEV 1 /FVC less than the LLN (area under the curve (AUC): 0.90, 95% CI, 0.89 to 0.91, κ coefficient 0.82). The FEV 6 also had excellent agreement in identifying FVC less than the LLN (AUC: 0.95, 95% CI, 0.94 to 0.95, κ coefficient 0.90). Discordant reductions in FEV 1 /FEV 6 (1%, 345) and FEV 6 (1%, 309) were associated with greater odds of having respiratory symptoms and a lower physical quality of life. 3870 participants were followed up. Those with discordant reductions in FEV 1 /FEV 6 and FEV 6 were more likely to have chronic airflow obstruction and spirometric restriction at follow-up. Conclusions: There is strong agreement between the FVC and FEV 6 in the identification of chronic airflow obstruction and spirometric restriction.
- 13 July 2025
- Published by BMJ in BMJ Open Respiratory Research
- Vol. 12 (1) , e002355
Open AccessConcordance between FVC and FEV 6 for identifying chronic airflow obstruction and spirometric restriction in the Burden of Obstructive Lung Disease (BOLD) study
Introduction: We investigated whether the forced expiratory volume in 6 s (FEV 6 ) can be used as a surrogate for the forced vital capacity (FVC). Methods: The Burden of Obstructive Lung Disease is a multinational cohort study. At baseline, data were collected from adults, aged 40 years or older, from 41 sites across 34 countries. Participants from 18 sites were followed-up after a median of 8.3 years. Participants who completed the study core questionnaire and had acceptable post-bronchodilator spirometry were included. We performed receiver operating characteristic analyses to measure the ability of FEV 1 /FEV 6 less than the lower limit of normal (LLN) to correctly classify FEV 1 /FVC less than the LLN, and FEV 6 less than the LLN to correctly classify FVC less than the LLN. We used multilevel regression analyses to assess the association of discordant measurements with respiratory symptoms, quality of life and lung function decline. Results: At baseline, 28 604 participants were included. 53% were female (15 060). 10% (2876) had chronic airflow obstruction for FEV 1 /FVC, compared with 9% (2704) for FEV 1 /FEV 6 . 37% (10 637) had spirometric restriction for FVC, compared with 35% (9978) for FEV 6 . The FEV 1 /FEV 6 had excellent accuracy in identifying FEV 1 /FVC less than the LLN (area under the curve (AUC): 0.90, 95% CI, 0.89 to 0.91, κ coefficient 0.82). The FEV 6 also had excellent agreement in identifying FVC less than the LLN (AUC: 0.95, 95% CI, 0.94 to 0.95, κ coefficient 0.90). Discordant reductions in FEV 1 /FEV 6 (1%, 345) and FEV 6 (1%, 309) were associated with greater odds of having respiratory symptoms and a lower physical quality of life. 3870 participants were followed up. Those with discordant reductions in FEV 1 /FEV 6 and FEV 6 were more likely to have chronic airflow obstruction and spirometric restriction at follow-up. Conclusions: There is strong agreement between the FVC and FEV 6 in the identification of chronic airflow obstruction and spirometric restriction.
- Open Access
- 28 February 2025
- Published by Sociedade Brasileira de Pneumologia e Tisiologia in Jornal Brasileiro de Pneumologia
- Vol. 51 (1) , e20240342
The thirty-second sit-to-stand test as a predictor of postoperative complications of lung resection: a real-world study
- 28 February 2025
- Published by Sociedade Brasileira de Pneumologia e Tisiologia in Jornal Brasileiro de Pneumologia
- Vol. 51 (1) , e20240342
Open AccessThe thirty-second sit-to-stand test as a predictor of postoperative complications of lung resection: a real-world study
- Open Access
- 30 November 2024
- Published by Taylor & Francis in Pulmonology
- Vol. 30 (6) , 586-594
Profile of emergency department overuse in hospitalized patients with pulmonary disease and its impact on mortality
Portugal is one of the countries with the highest number of visits to the emergency department (ED), 31% classified as "non-urgent" or "avoidable." The objectives of our study were to evaluate the size and characteristics of patients with pulmonary disease who overuse the ED, and identify factors associated with mortality. A retrospective cohort study was conducted, based on the medical records of ED frequent users (ED-FU) with pulmonary disease who attended a university hospital center in the northern inner city of Lisbon from January 1 to December 31, 2019. To evaluate mortality, a follow-up until December 31, 2020 was performed. Over 5,567 (4.3%) patients were identified as ED-FU and 174 (0.14%) had pulmonary disease as the main clinical condition, accounting for 1,030 ED visits. 77.2% of ED visits were categorized as "urgent/very urgent." A high mean age (67.8 years), male gender, social and economic vulnerability, high burden of chronic disease and comorbidities, with a high degree of dependency, characterized the profile of these patients. A high proportion (33.9%) of patients did not have a family physician assigned and this was the most important factor associated with mortality (p<0.001; OR: 24.394; CI 95%: 6.777-87.805). Advanced cancer disease and autonomy deficit were other clinical factors that most determined the prognosis. Pulmonary ED-FU are a small group of ED-FU who constitute an aged and heterogeneous group with a high burden of chronic disease and disability. The lack of an assigned family physician was the most important factor associated with mortality, as well as advanced cancer disease and autonomy deficit.
- 30 November 2024
- Published by Taylor & Francis in Pulmonology
- Vol. 30 (6) , 586-594
Open AccessProfile of emergency department overuse in hospitalized patients with pulmonary disease and its impact on mortality
Portugal is one of the countries with the highest number of visits to the emergency department (ED), 31% classified as "non-urgent" or "avoidable." The objectives of our study were to evaluate the size and characteristics of patients with pulmonary disease who overuse the ED, and identify factors associated with mortality. A retrospective cohort study was conducted, based on the medical records of ED frequent users (ED-FU) with pulmonary disease who attended a university hospital center in the northern inner city of Lisbon from January 1 to December 31, 2019. To evaluate mortality, a follow-up until December 31, 2020 was performed. Over 5,567 (4.3%) patients were identified as ED-FU and 174 (0.14%) had pulmonary disease as the main clinical condition, accounting for 1,030 ED visits. 77.2% of ED visits were categorized as "urgent/very urgent." A high mean age (67.8 years), male gender, social and economic vulnerability, high burden of chronic disease and comorbidities, with a high degree of dependency, characterized the profile of these patients. A high proportion (33.9%) of patients did not have a family physician assigned and this was the most important factor associated with mortality (p<0.001; OR: 24.394; CI 95%: 6.777-87.805). Advanced cancer disease and autonomy deficit were other clinical factors that most determined the prognosis. Pulmonary ED-FU are a small group of ED-FU who constitute an aged and heterogeneous group with a high burden of chronic disease and disability. The lack of an assigned family physician was the most important factor associated with mortality, as well as advanced cancer disease and autonomy deficit.
- Open Access
Design and Evaluation of a Novel Venturi-Based Spirometer for Home Respiratory Monitoring
The high cost and limited availability of home spirometers pose a significant barrier to effective respiratory disease management and monitoring. To address this challenge, this paper introduces a novel Venturi-based spirometer designed for home use, leveraging the Bernoulli principle. The device features a 3D-printed Venturi tube that narrows to create a pressure differential, which is measured by a differential pressure sensor and converted into airflow rate. The airflow is then integrated over time to calculate parameters such as the Forced Vital Capacity (FVC) and Forced Expiratory Volume in one second (FEV1). The system also includes a bacterial filter for hygienic use and a circuit board for data acquisition and streaming. Evaluation with eight healthy individuals demonstrated excellent test-retest reliability, with intraclass correlation coefficients (ICCs) of 0.955 for FVC and 0.853 for FEV1. Furthermore, when compared to standard Pulmonary Function Test (PFT) equipment, the spirometer exhibited strong correlation, with Pearson correlation coefficients of 0.992 for FVC and 0.968 for FEV1, and high reliability, with ICCs of 0.987 for FVC and 0.907 for FEV1. These findings suggest that the Venturi-based spirometer could significantly enhance access to spirometry at home. However, further large-scale validation and reliability studies are necessary to confirm its efficacy and reliability for widespread use.
Open AccessDesign and Evaluation of a Novel Venturi-Based Spirometer for Home Respiratory Monitoring
The high cost and limited availability of home spirometers pose a significant barrier to effective respiratory disease management and monitoring. To address this challenge, this paper introduces a novel Venturi-based spirometer designed for home use, leveraging the Bernoulli principle. The device features a 3D-printed Venturi tube that narrows to create a pressure differential, which is measured by a differential pressure sensor and converted into airflow rate. The airflow is then integrated over time to calculate parameters such as the Forced Vital Capacity (FVC) and Forced Expiratory Volume in one second (FEV1). The system also includes a bacterial filter for hygienic use and a circuit board for data acquisition and streaming. Evaluation with eight healthy individuals demonstrated excellent test-retest reliability, with intraclass correlation coefficients (ICCs) of 0.955 for FVC and 0.853 for FEV1. Furthermore, when compared to standard Pulmonary Function Test (PFT) equipment, the spirometer exhibited strong correlation, with Pearson correlation coefficients of 0.992 for FVC and 0.968 for FEV1, and high reliability, with ICCs of 0.987 for FVC and 0.907 for FEV1. These findings suggest that the Venturi-based spirometer could significantly enhance access to spirometry at home. However, further large-scale validation and reliability studies are necessary to confirm its efficacy and reliability for widespread use.
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (7) , 2243-2252
A Magnetic Field-Based Wearable Respiration Sensor for Real-Time Monitoring During Pulmonary Rehabilitation
Objective: This work explores Hall effect sensing paired with a permanent magnet, in the context of pulmonary rehabilitation exercise training. Methods: Experimental evaluation was performed considering as reference the gold-standard of respiratory monitoring, an airflow transducer, and performance was compared to another wearable device with analogous usability - a piezoelectric sensor. A total of 16 healthy participants performed 15 activities, representative of pulmonary rehabilitation exercises, simultaneously using all devices. Evaluation was performed based on detection of flow reversal events and key respiratory parameters. Results: Overall, the proposed sensor outperformed the piezoelectric sensor with a mean ratio, precision, and recall of 0.97, 0.97, and 0.95, respectively, against 0.98, 0.90, and 0.88. Evaluation regarding the respiratory parameters indicates an adequate accuracy when it comes to breath cycle, inspiration, and expiration times, with mean relative errors around 4% for breath cycle and 8% for inspiration/expiration times, despite some variability. Bland-Altman analysis indicates no systematic biases. Conclusion: Characterization of the proposed sensor shows adequate monitoring capabilities for exercises that do not rely heavily on torso mobility, but may present a limitation when it comes to activities such as side stretches. Significance: This work provides a comprehensive characterization of a magnetic field-based respiration sensor, including a discussion on its robustness to different algorithm thresholds. It proves the viability of the sensor in a range of exercises, expanding the applicability of Hall effect sensors as a feasible wearable approach to real-time respiratory monitoring.
- 20 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (7) , 2243-2252
A Magnetic Field-Based Wearable Respiration Sensor for Real-Time Monitoring During Pulmonary Rehabilitation
Objective: This work explores Hall effect sensing paired with a permanent magnet, in the context of pulmonary rehabilitation exercise training. Methods: Experimental evaluation was performed considering as reference the gold-standard of respiratory monitoring, an airflow transducer, and performance was compared to another wearable device with analogous usability - a piezoelectric sensor. A total of 16 healthy participants performed 15 activities, representative of pulmonary rehabilitation exercises, simultaneously using all devices. Evaluation was performed based on detection of flow reversal events and key respiratory parameters. Results: Overall, the proposed sensor outperformed the piezoelectric sensor with a mean ratio, precision, and recall of 0.97, 0.97, and 0.95, respectively, against 0.98, 0.90, and 0.88. Evaluation regarding the respiratory parameters indicates an adequate accuracy when it comes to breath cycle, inspiration, and expiration times, with mean relative errors around 4% for breath cycle and 8% for inspiration/expiration times, despite some variability. Bland-Altman analysis indicates no systematic biases. Conclusion: Characterization of the proposed sensor shows adequate monitoring capabilities for exercises that do not rely heavily on torso mobility, but may present a limitation when it comes to activities such as side stretches. Significance: This work provides a comprehensive characterization of a magnetic field-based respiration sensor, including a discussion on its robustness to different algorithm thresholds. It proves the viability of the sensor in a range of exercises, expanding the applicability of Hall effect sensors as a feasible wearable approach to real-time respiratory monitoring.
- Open Access
- 10 July 2023
- Published by Sociedade Brasileira de Pneumologia e Tisiologia in Jornal Brasileiro de Pneumologia
- Vol. 49 (4) , e20220372
Cultural adaptation and validation of the Brazilian Portuguese version of the PROactive Physical Activity in COPD–clinical visit instrument for individuals with COPD
Objective: To adapt the PROactive Physical Activity in COPD-clinical visit (C-PPAC) instrument to the cultural setting in Brazil and to determine the criterion validity, test-retest reliability agreement, and internal consistency of this version. Methods: A protocol for cultural adaptation and validation was provided by the authors of the original instrument and, together with another guideline, was applied in a Portuguese-language version developed by a partner research group from Portugal. The adapted Brazilian Portuguese version was then cross-sectionally administered twice within a seven-day interval to 30 individuals with COPD (57% were men; mean age was 69 ± 6 years; and mean FEV1 was 53 ± 18% of predicted) to evaluate internal consistency and test-retest reliability. Participants also completed the International Physical Activity Questionnaire (IPAQ), the modified Medical Research Council scale, the COPD Assessment Test, and Saint George's Respiratory Questionnaire to evaluate criterion validity. Results: The C-PPAC instrument showed good internal consistency and excellent test-retest reliability:
- 10 July 2023
- Published by Sociedade Brasileira de Pneumologia e Tisiologia in Jornal Brasileiro de Pneumologia
- Vol. 49 (4) , e20220372
Open AccessCultural adaptation and validation of the Brazilian Portuguese version of the PROactive Physical Activity in COPD–clinical visit instrument for individuals with COPD
Objective: To adapt the PROactive Physical Activity in COPD-clinical visit (C-PPAC) instrument to the cultural setting in Brazil and to determine the criterion validity, test-retest reliability agreement, and internal consistency of this version. Methods: A protocol for cultural adaptation and validation was provided by the authors of the original instrument and, together with another guideline, was applied in a Portuguese-language version developed by a partner research group from Portugal. The adapted Brazilian Portuguese version was then cross-sectionally administered twice within a seven-day interval to 30 individuals with COPD (57% were men; mean age was 69 ± 6 years; and mean FEV1 was 53 ± 18% of predicted) to evaluate internal consistency and test-retest reliability. Participants also completed the International Physical Activity Questionnaire (IPAQ), the modified Medical Research Council scale, the COPD Assessment Test, and Saint George's Respiratory Questionnaire to evaluate criterion validity. Results: The C-PPAC instrument showed good internal consistency and excellent test-retest reliability: