Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Fátima Rodrigues has a total of 341 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Awareness without actionable knowledge: understanding physical activity recommendations among people with COPD

    by Renato Reis, José Albino, Paula Duarte, Fátima Rodrigues, Ana Filipe Santos, Ana Martins, Carla Cruzinha, Filipa Januário, João Neiva Machado, João Goulão, et al.

  • Measuring adult breathing pattern: devices, outcomes, and evidence—a scoping review

    by Rodrigo Martins, Fátima Rodrigues, Ana Martins, Bruno Neves, Helena Silva, João Guerra, Susana Costa, Nélson Costa

  • Open Access

    Impacto de um Modelo Integrado de Cuidados em Doentes com DPOC e Risco Elevado de Reinternamento

    by Diana Organista, Maria Fátima Caetano, Jorge Lopes da Costa, Andreia Fernandes, Ana Almeida, Cátia Brás, Paula Ricardo, Maria João Figueiredo, Alexandra Ramos Cortês, Paula Cristina Reis, et al.

    A doença pulmonar obstrutiva crónica (DPOC) está associada a elevada morbilidade e utilização de serviços de saúde, particularmente na sequência de exacerbações agudas que levam ao serviço de urgência (SU) e internamentos hospitalares. Doentes com comorbilidades e vulnerabilidade social apresentam maior risco de reinternamento. Este estudo teve como objetivo avaliar o impacto de uma intervenção precoce com um plano individual e integrado de cuidados (PIC) na redução de deslocações ao SU e internamentos em doentes com DPOC de alto risco. O protocolo Avaliação Pneumológica Precoce/Plano Individual de Cuidados (APP/PIC) foi implementado em fevereiro de 2024. Os doentes com risco elevado foram identificados através do cálculo do índice LACE (> 9 pontos ou 5 – 9 na presença de fatores adicionais). A intervenção combinou avaliação médica, enfermagem e serviço social, através de um modelo de seguimento híbrido, presencial e remoto. Os principais dados avaliados foram o número de idas ao SU e internamentos hospitalares no ano anterior e posterior à instituição do protocolo. Foi utilizado o teste t de Student emparelhado para a análise. Foram incluídos 53 doentes (média de idade de 67,6 anos; 62% do sexo masculino). A média do índice de comorbilidades de Charlson foi de 4,5 pontos e do índice LACE 13,8 pontos. Um ano depois, o número médio de idas ao SU reduziu de 3,09 para 0,067 (p < 0,001), e o número de internamentos, de 1,39 para 0,33 (p < 0,001). O seguimento remoto gerou alertas clínicos que resultaram em consultas médicas e de enfermagem, tendo apenas dois casos necessitado de encaminhamento ao SU e internamento por insuficiência respiratória grave. A intervenção social permitiu que a maioria dos doentes mantivesse ou retomasse apoio domiciliário. O protocolo APP/PIC demonstrou eficácia na redução de idas ao SU e internamentos em doentes com DPOC de alto risco. Este modelo representa uma abordagem promissora e sustentável para a gestão integrada de doenças respiratórias crónicas.

  • Open Access

    Concordance between FVC and FEV 6 for identifying chronic airflow obstruction and spirometric restriction in the Burden of Obstructive Lung Disease (BOLD) study

    by Ben Knox-Brown, James Potts, Frits M E Franssen, Rune Nielsen, Meriam Denguezli, Anders Ørskov Rotevatn, Sanjay K Juvekar, Hamid Hacene Cherkaski, Michael Studnicka, Karl Peter Sylvester, et al.

    Introduction: We investigated whether the forced expiratory volume in 6 s (FEV 6 ) can be used as a surrogate for the forced vital capacity (FVC). Methods: The Burden of Obstructive Lung Disease is a multinational cohort study. At baseline, data were collected from adults, aged 40 years or older, from 41 sites across 34 countries. Participants from 18 sites were followed-up after a median of 8.3 years. Participants who completed the study core questionnaire and had acceptable post-bronchodilator spirometry were included. We performed receiver operating characteristic analyses to measure the ability of FEV 1 /FEV 6 less than the lower limit of normal (LLN) to correctly classify FEV 1 /FVC less than the LLN, and FEV 6 less than the LLN to correctly classify FVC less than the LLN. We used multilevel regression analyses to assess the association of discordant measurements with respiratory symptoms, quality of life and lung function decline. Results: At baseline, 28 604 participants were included. 53% were female (15 060). 10% (2876) had chronic airflow obstruction for FEV 1 /FVC, compared with 9% (2704) for FEV 1 /FEV 6 . 37% (10 637) had spirometric restriction for FVC, compared with 35% (9978) for FEV 6 . The FEV 1 /FEV 6 had excellent accuracy in identifying FEV 1 /FVC less than the LLN (area under the curve (AUC): 0.90, 95% CI, 0.89 to 0.91, κ coefficient 0.82). The FEV 6 also had excellent agreement in identifying FVC less than the LLN (AUC: 0.95, 95% CI, 0.94 to 0.95, κ coefficient 0.90). Discordant reductions in FEV 1 /FEV 6 (1%, 345) and FEV 6 (1%, 309) were associated with greater odds of having respiratory symptoms and a lower physical quality of life. 3870 participants were followed up. Those with discordant reductions in FEV 1 /FEV 6 and FEV 6 were more likely to have chronic airflow obstruction and spirometric restriction at follow-up. Conclusions: There is strong agreement between the FVC and FEV 6 in the identification of chronic airflow obstruction and spirometric restriction.


  • Open Access

    The thirty-second sit-to-stand test as a predictor of postoperative complications of lung resection: a real-world study

    by Inês Fernandes Pedro, Diana Organista, Teresa Seguro, Mariana Maia Silva, Fátima Rodrigues


  • Open Access

    Profile of emergency department overuse in hospitalized patients with pulmonary disease and its impact on mortality

    by J. Barbosa, D. Organista, T. Rodrigues, A.F. Matos, A. Barardo, A. Escoval, C. Bárbara, F. Rodrigues

    Portugal is one of the countries with the highest number of visits to the emergency department (ED), 31% classified as "non-urgent" or "avoidable." The objectives of our study were to evaluate the size and characteristics of patients with pulmonary disease who overuse the ED, and identify factors associated with mortality. A retrospective cohort study was conducted, based on the medical records of ED frequent users (ED-FU) with pulmonary disease who attended a university hospital center in the northern inner city of Lisbon from January 1 to December 31, 2019. To evaluate mortality, a follow-up until December 31, 2020 was performed. Over 5,567 (4.3%) patients were identified as ED-FU and 174 (0.14%) had pulmonary disease as the main clinical condition, accounting for 1,030 ED visits. 77.2% of ED visits were categorized as "urgent/very urgent." A high mean age (67.8 years), male gender, social and economic vulnerability, high burden of chronic disease and comorbidities, with a high degree of dependency, characterized the profile of these patients. A high proportion (33.9%) of patients did not have a family physician assigned and this was the most important factor associated with mortality (p<0.001; OR: 24.394; CI 95%: 6.777-87.805). Advanced cancer disease and autonomy deficit were other clinical factors that most determined the prognosis. Pulmonary ED-FU are a small group of ED-FU who constitute an aged and heterogeneous group with a high burden of chronic disease and disability. The lack of an assigned family physician was the most important factor associated with mortality, as well as advanced cancer disease and autonomy deficit.


  • Open Access

    Design and Evaluation of a Novel Venturi-Based Spirometer for Home Respiratory Monitoring

    by Mariana Ferreira Nunes, Hugo Plácido da Silva, Liliana Raposo, Fátima Rodrigues

    The high cost and limited availability of home spirometers pose a significant barrier to effective respiratory disease management and monitoring. To address this challenge, this paper introduces a novel Venturi-based spirometer designed for home use, leveraging the Bernoulli principle. The device features a 3D-printed Venturi tube that narrows to create a pressure differential, which is measured by a differential pressure sensor and converted into airflow rate. The airflow is then integrated over time to calculate parameters such as the Forced Vital Capacity (FVC) and Forced Expiratory Volume in one second (FEV1). The system also includes a bacterial filter for hygienic use and a circuit board for data acquisition and streaming. Evaluation with eight healthy individuals demonstrated excellent test-retest reliability, with intraclass correlation coefficients (ICCs) of 0.955 for FVC and 0.853 for FEV1. Furthermore, when compared to standard Pulmonary Function Test (PFT) equipment, the spirometer exhibited strong correlation, with Pearson correlation coefficients of 0.992 for FVC and 0.968 for FEV1, and high reliability, with ICCs of 0.987 for FVC and 0.907 for FEV1. These findings suggest that the Venturi-based spirometer could significantly enhance access to spirometry at home. However, further large-scale validation and reliability studies are necessary to confirm its efficacy and reliability for widespread use.


  • A Magnetic Field-Based Wearable Respiration Sensor for Real-Time Monitoring During Pulmonary Rehabilitation

    by Ana Sofia Carmo, Inês Carvalho, Joana F. Pinto, Gonçalo Chambel, Ana Martins, Rute Roberto, Hugo Ferreira, Fátima Rodrigues, Ana Fred, Hugo Plácido da Silva

    Objective: This work explores Hall effect sensing paired with a permanent magnet, in the context of pulmonary rehabilitation exercise training. Methods: Experimental evaluation was performed considering as reference the gold-standard of respiratory monitoring, an airflow transducer, and performance was compared to another wearable device with analogous usability - a piezoelectric sensor. A total of 16 healthy participants performed 15 activities, representative of pulmonary rehabilitation exercises, simultaneously using all devices. Evaluation was performed based on detection of flow reversal events and key respiratory parameters. Results: Overall, the proposed sensor outperformed the piezoelectric sensor with a mean ratio, precision, and recall of 0.97, 0.97, and 0.95, respectively, against 0.98, 0.90, and 0.88. Evaluation regarding the respiratory parameters indicates an adequate accuracy when it comes to breath cycle, inspiration, and expiration times, with mean relative errors around 4% for breath cycle and 8% for inspiration/expiration times, despite some variability. Bland-Altman analysis indicates no systematic biases. Conclusion: Characterization of the proposed sensor shows adequate monitoring capabilities for exercises that do not rely heavily on torso mobility, but may present a limitation when it comes to activities such as side stretches. Significance: This work provides a comprehensive characterization of a magnetic field-based respiration sensor, including a discussion on its robustness to different algorithm thresholds. It proves the viability of the sensor in a range of exercises, expanding the applicability of Hall effect sensors as a feasible wearable approach to real-time respiratory monitoring.


  • Open Access

    Cultural adaptation and validation of the Brazilian Portuguese version of the PROactive Physical Activity in COPD–clinical visit instrument for individuals with COPD

    by Andre Vinicius Santana, Andrea Daiane Fontana, Rafaela Cristina de Almeida, Leandro Cruz Mantoani, Carlos Augusto Camillo, Karina Couto Furlanetto, Fatima Rodrigues, Joana Cruz, Alda Marques, Cristina Jacome, et al.

    Objective: To adapt the PROactive Physical Activity in COPD-clinical visit (C-PPAC) instrument to the cultural setting in Brazil and to determine the criterion validity, test-retest reliability agreement, and internal consistency of this version. Methods: A protocol for cultural adaptation and validation was provided by the authors of the original instrument and, together with another guideline, was applied in a Portuguese-language version developed by a partner research group from Portugal. The adapted Brazilian Portuguese version was then cross-sectionally administered twice within a seven-day interval to 30 individuals with COPD (57% were men; mean age was 69 ± 6 years; and mean FEV1 was 53 ± 18% of predicted) to evaluate internal consistency and test-retest reliability. Participants also completed the International Physical Activity Questionnaire (IPAQ), the modified Medical Research Council scale, the COPD Assessment Test, and Saint George's Respiratory Questionnaire to evaluate criterion validity. Results: The C-PPAC instrument showed good internal consistency and excellent test-retest reliability: