Yusuke Hamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yusuke Hamada has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Steven B. Blanchard
Department of Periodontology Indiana University School of Dentistry Indianapolis Indiana USA
6 shared publicationsRichard L. Gregory
Department of Biomedical Sciences and Comprehensive Care Indiana University School of Dentistry Indianapolis Indiana USA
5 shared publications- Vanchit John
Department of Periodontics and Allied Dental Programs Indiana University School of Dentistry
5 shared publications Daniel Shin
Department of Periodontics and Allied Dental Program, Indiana University School of Dentistry, Indianapolis, IN 46202, USA
4 shared publicationsSteven Blanchard
Department of Periodontology, Indiana University School of Dentistry, Indianapolis, IN, USA
4 shared publications- Wei‐Shao Lin
Department of Prosthodontics Indiana University School of Dentistry Indianapolis Indiana USA
4 shared publications
Latest Publications
- 21 February 2025
- Published by Wiley in Journal of Prosthodontics
- Vol. 35 (3) , 367-374
An in vitro assessment of the accuracy of guided tilted and axial implant placement in the edentulous mandible
Purpose: To assess the precision of implant placement when comparing tilted orientations to axial orientations, utilizing a fully guided surgical protocol in an edentulous mandibular model. Materials and Methods: Fourteen rubber‐coated mandibular models were scanned with fiducial markers using a commercial benchtop surface scanner, followed by cone beam computed tomography for implant planning through a dual‐scan protocol. The models were randomly divided into control and experimental groups. In the control group, each model was planned for four axially oriented implants. Conversely, the experimental models were planned for two axially oriented implants near the lateral incisors and two posteriorly tilted implants at a 30‐degree angle. A mucosal‐supported, pin‐retained surgical guide was designed and 3D‐printed, facilitating the fully guided implant placement. All implants received scan bodies and were rescanned for evaluation of the trueness between the planned and the actual implant location using the implant planning software. Mixed model ANOVA was used to detect differences between groups with regards to angular deviation, offset at base, and offset at tip. Results: A total of 56 implants were placed across all models. Fourteen posterior implants in each group served as control and experimental conditions, while the remaining 28 anterior implants acted as secondary control. No significant differences were observed between the experimental and control groups in terms of angular deviation ( p = 0.7001), offset at base ( p = 0.6409), or offset at tip ( p = 0.6931). Analysis comparing anterior implant deviations between groups and anterior to posterior implant deviations within the control arches also was not significant. However, secondary analysis revealed a significant difference between anterior and posterior implants within the experimental group for offset at base ( p = 0.0087) and offset at tip ( p = 0.0288). Conclusions: Despite the limitations inherent to a benchtop study, the findings suggest that there are no statistically significant 3D deviations at the base or apex, nor in angular deviations, when comparing tilted and axial implant placements using a digital workflow and fully guided protocols in an edentulous model.
- 21 February 2025
- Published by Wiley in Journal of Prosthodontics
- Vol. 35 (3) , 367-374
An in vitro assessment of the accuracy of guided tilted and axial implant placement in the edentulous mandible
Purpose: To assess the precision of implant placement when comparing tilted orientations to axial orientations, utilizing a fully guided surgical protocol in an edentulous mandibular model. Materials and Methods: Fourteen rubber‐coated mandibular models were scanned with fiducial markers using a commercial benchtop surface scanner, followed by cone beam computed tomography for implant planning through a dual‐scan protocol. The models were randomly divided into control and experimental groups. In the control group, each model was planned for four axially oriented implants. Conversely, the experimental models were planned for two axially oriented implants near the lateral incisors and two posteriorly tilted implants at a 30‐degree angle. A mucosal‐supported, pin‐retained surgical guide was designed and 3D‐printed, facilitating the fully guided implant placement. All implants received scan bodies and were rescanned for evaluation of the trueness between the planned and the actual implant location using the implant planning software. Mixed model ANOVA was used to detect differences between groups with regards to angular deviation, offset at base, and offset at tip. Results: A total of 56 implants were placed across all models. Fourteen posterior implants in each group served as control and experimental conditions, while the remaining 28 anterior implants acted as secondary control. No significant differences were observed between the experimental and control groups in terms of angular deviation ( p = 0.7001), offset at base ( p = 0.6409), or offset at tip ( p = 0.6931). Analysis comparing anterior implant deviations between groups and anterior to posterior implant deviations within the control arches also was not significant. However, secondary analysis revealed a significant difference between anterior and posterior implants within the experimental group for offset at base ( p = 0.0087) and offset at tip ( p = 0.0288). Conclusions: Despite the limitations inherent to a benchtop study, the findings suggest that there are no statistically significant 3D deviations at the base or apex, nor in angular deviations, when comparing tilted and axial implant placements using a digital workflow and fully guided protocols in an edentulous model.
- Open Access
- 15 January 2025
- Published by Wiley in Journal of Prosthodontics
The effects of anodization and instrumentation on titanium abutment surface characteristics and biofilm formation
Purpose: To assess the impact of anodization and instrumentation on titanium abutment surface characteristics (surface roughness and wettability) and biofilm formation (viability and mass).Materials and Methods: Titanium discs were obtained from pre‐milled abutment blanks made of titanium‐6aluminum‐7niobium alloy. Polished samples were divided into three groups: un‐anodized, gold‐anodized, and pink‐anodized. Instrumentation methods included no‐instrumentation, air polishing, and titanium scaling treatment. Surface roughness was measured using an optical profilometer, and wettability was determined by measuring the contact angles using the sessile drop method with an optical tensiometer. Biofilm formation by Streptococcus sanguinis was evaluated based on the biofilm viability and mass. The biofilm viability was evaluated through colony‐forming unit counting (CFU/mL), and biofilm mass was assessed with crystal violet staining (mean absorbance measured at 490 nm, in optical density values). Sample surfaces before and after biofilm formation were also examined by scanning electron microscope (SEM). Two‐way ANOVA was performed to determine the group differences, and Spearman's correlation (ρ) was used to analyze the correlation among surface roughness, wettability, and CFU/mL (α = 0.05).Results: Pink anodization significantly increased surface roughness (0.38 ± 0.07 µm, p < 0.001) compared to un‐anodized samples (0.25 ± 0.01 µm), while gold anodization did not (0.24 ± 0.03 µm, p = 0.301). Among pink‐anodized groups, air polishing resulted in significantly lower surface roughness (0.33 ± 0.08 µm) compared to titanium scaling (0.51 ± 0.11 µm, p < 0.001) and no instrument treatment (0.38 ± 0.07 µm, p = 0.050). Anodization significantly increased wettability (p < 0.001), while instrumentation with a titanium scaling decreased it (p < 0.001). The combination of un‐anodized samples and titanium scaling treatment showed the lowest wettability with the highest contact angle (70.72 ± 2.63°). The biofilm viability, measured by CFU/mL, was significantly inhibited by anodization (p < 0.001) and air polishing (p < 0.001) while promoted by titanium scaling (p < 0.001). Gold‐anodized titanium discs subjected to air polishing exhibited the lowest CFU/mL (279,420 ± 16,300), while un‐anodized samples instrumented with a titanium scaler had the highest CFU/mL (945,580 ± 13,580). Biofilm mass, quantified by optical density values, was significantly inhibited by anodization (p < 0.001) as well as air polishing (p = 0.001). A moderate negative correlation was observed between CFU and wettability (ρ = −0.55, p < 0.001).Conclusion: Gold‐ and pink‐anodized titanium surfaces were more hydrophilic, leading to less biofilm formation than un‐anodized ones. Biofilm formation was inhibited by air polishing while promoted by titanium scaling. Gold anodization combined with air polishing had the least biofilm formation and can be considered the preferred abutment anodization/instrumentation combination.
- 15 January 2025
- Published by Wiley in Journal of Prosthodontics
Open AccessThe effects of anodization and instrumentation on titanium abutment surface characteristics and biofilm formation
Purpose: To assess the impact of anodization and instrumentation on titanium abutment surface characteristics (surface roughness and wettability) and biofilm formation (viability and mass).Materials and Methods: Titanium discs were obtained from pre‐milled abutment blanks made of titanium‐6aluminum‐7niobium alloy. Polished samples were divided into three groups: un‐anodized, gold‐anodized, and pink‐anodized. Instrumentation methods included no‐instrumentation, air polishing, and titanium scaling treatment. Surface roughness was measured using an optical profilometer, and wettability was determined by measuring the contact angles using the sessile drop method with an optical tensiometer. Biofilm formation by Streptococcus sanguinis was evaluated based on the biofilm viability and mass. The biofilm viability was evaluated through colony‐forming unit counting (CFU/mL), and biofilm mass was assessed with crystal violet staining (mean absorbance measured at 490 nm, in optical density values). Sample surfaces before and after biofilm formation were also examined by scanning electron microscope (SEM). Two‐way ANOVA was performed to determine the group differences, and Spearman's correlation (ρ) was used to analyze the correlation among surface roughness, wettability, and CFU/mL (α = 0.05).Results: Pink anodization significantly increased surface roughness (0.38 ± 0.07 µm, p < 0.001) compared to un‐anodized samples (0.25 ± 0.01 µm), while gold anodization did not (0.24 ± 0.03 µm, p = 0.301). Among pink‐anodized groups, air polishing resulted in significantly lower surface roughness (0.33 ± 0.08 µm) compared to titanium scaling (0.51 ± 0.11 µm, p < 0.001) and no instrument treatment (0.38 ± 0.07 µm, p = 0.050). Anodization significantly increased wettability (p < 0.001), while instrumentation with a titanium scaling decreased it (p < 0.001). The combination of un‐anodized samples and titanium scaling treatment showed the lowest wettability with the highest contact angle (70.72 ± 2.63°). The biofilm viability, measured by CFU/mL, was significantly inhibited by anodization (p < 0.001) and air polishing (p < 0.001) while promoted by titanium scaling (p < 0.001). Gold‐anodized titanium discs subjected to air polishing exhibited the lowest CFU/mL (279,420 ± 16,300), while un‐anodized samples instrumented with a titanium scaler had the highest CFU/mL (945,580 ± 13,580). Biofilm mass, quantified by optical density values, was significantly inhibited by anodization (p < 0.001) as well as air polishing (p = 0.001). A moderate negative correlation was observed between CFU and wettability (ρ = −0.55, p < 0.001).Conclusion: Gold‐ and pink‐anodized titanium surfaces were more hydrophilic, leading to less biofilm formation than un‐anodized ones. Biofilm formation was inhibited by air polishing while promoted by titanium scaling. Gold anodization combined with air polishing had the least biofilm formation and can be considered the preferred abutment anodization/instrumentation combination.
- 1 July 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (1) , 68-73
Evaluation of the accuracy of buccal bone thickness measurement from cone beam computed tomography compared with histologic analysis
- 1 July 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (1) , 68-73
Evaluation of the accuracy of buccal bone thickness measurement from cone beam computed tomography compared with histologic analysis
- Open Access
- 1 January 2023
- Published by Wiley in BioMed Research International
- Vol. 2023 (1)
Comparison of In Vitro Biofilm Formation on Titanium and Zirconia Implants
Background. Peri‐implant diseases are emerging issues in contemporary implant dentistry. As biofilms play a critical role in peri‐implant diseases, the characteristic of resisting bacterial adhesion would be ideal for dental implants. The aims of the study were to compare titanium (Ti) and zirconia (Zr) implants regarding the amount of biofilm formation at different time frames and assess the distribution of biofilm on different aspects of dental implants. Methods. Biofilm was developed on Ti and Zr dental implants with a peri‐implant‐related multispecies model with Streptococcus oralis, Actinomyces naeslundii, Veillonella dispar, and Porphyromonas gingivalis, for 3 and 14 days. Quantitative assessment was performed with the measurement of total bacterial viability (colony forming units, CFU/mg). Scanning electron microscopy (SEM) was used to evaluate biofilm formation on different aspects of the implants. Results. Three‐day‐old biofilm on Ti implants was significantly higher than that on Zr implants (p < 0.001). The Ti and Zr groups were not significantly different for 14‐day‐old biofilm. SEM images demonstrated that 3‐day‐old biofilm on Zr implants was sparse while biofilm growth was more pronounced for 3‐day‐old biofilm on Ti implants and 14‐day‐old biofilm groups. It appeared that less biofilm formed on the valley compared to the thread top for 3‐day‐old biofilm on Zr implants. Differences between the valley and the thread top became indistinguishable with the development of mature biofilm. Conclusion. While early formed biofilms show greater accumulation on Ti implants compared to Zr implants, older biofilms between the two groups are comparable. The distribution of biofilms was not uniform on different areas of implant threads during early biofilm development.
- 1 January 2023
- Published by Wiley in BioMed Research International
- Vol. 2023 (1)
Open AccessComparison of In Vitro Biofilm Formation on Titanium and Zirconia Implants
Background. Peri‐implant diseases are emerging issues in contemporary implant dentistry. As biofilms play a critical role in peri‐implant diseases, the characteristic of resisting bacterial adhesion would be ideal for dental implants. The aims of the study were to compare titanium (Ti) and zirconia (Zr) implants regarding the amount of biofilm formation at different time frames and assess the distribution of biofilm on different aspects of dental implants. Methods. Biofilm was developed on Ti and Zr dental implants with a peri‐implant‐related multispecies model with Streptococcus oralis, Actinomyces naeslundii, Veillonella dispar, and Porphyromonas gingivalis, for 3 and 14 days. Quantitative assessment was performed with the measurement of total bacterial viability (colony forming units, CFU/mg). Scanning electron microscopy (SEM) was used to evaluate biofilm formation on different aspects of the implants. Results. Three‐day‐old biofilm on Ti implants was significantly higher than that on Zr implants (p < 0.001). The Ti and Zr groups were not significantly different for 14‐day‐old biofilm. SEM images demonstrated that 3‐day‐old biofilm on Zr implants was sparse while biofilm growth was more pronounced for 3‐day‐old biofilm on Ti implants and 14‐day‐old biofilm groups. It appeared that less biofilm formed on the valley compared to the thread top for 3‐day‐old biofilm on Zr implants. Differences between the valley and the thread top became indistinguishable with the development of mature biofilm. Conclusion. While early formed biofilms show greater accumulation on Ti implants compared to Zr implants, older biofilms between the two groups are comparable. The distribution of biofilms was not uniform on different areas of implant threads during early biofilm development.
- Open Access
- 20 June 2022
- Published by MDPI AG in Biomolecules
- Vol. 12 (6) , 857
Investigating the Effects of Dehydrated Human Amnion-Chorion Membrane on Periodontal Healing
Each growth factor (GF) has different effects and targets, and plays a critical role in periodontal healing. Dehydrated human amnion-chorion membrane (dHACM) contains various GFs and has been used to enhance wound healing. The purpose of this study was to evaluate the effects of dHACM on periodontal healing, using in vitro and in vivo experimental approaches. Standardized periodontal defects were created in rats. The defects were randomly divided into three groups: Unfilled, filled with hydroxypropyl cellulose (HPC), and dHACM+HPC. At 2 and 4 weeks postoperatively, periodontal healing was analyzed by microcomputed tomography (micro-CT), and histological and immunohistochemical analyses. In vitro, periodontal ligament-derived cells (PDLCs) isolated from rat incisors were incubated with dHACM extract. Cell proliferation and migration were evaluated by WST-1 and wound healing assay. In vivo, micro-CT examination at 2 weeks revealed enhanced formation of new bone in the dHACM+HPC group. At 4 weeks, the proportions of vascular endothelial growth factor (VEGF)-positive cells and α-smooth muscle actin (α-SMA)-positive blood vessels in the dHACM+HPC group were significantly greater than those in the Unfilled group. In vitro, dHACM extracts at 100 µg/mL significantly increased cell proliferation and migration compared with control. These findings suggest that GFs contained in dHACM promote proliferation and migration of PDLCs and angiogenesis, which lead to enhanced periodontal healing.
- 20 June 2022
- Published by MDPI AG in Biomolecules
- Vol. 12 (6) , 857
Open AccessInvestigating the Effects of Dehydrated Human Amnion-Chorion Membrane on Periodontal Healing
Each growth factor (GF) has different effects and targets, and plays a critical role in periodontal healing. Dehydrated human amnion-chorion membrane (dHACM) contains various GFs and has been used to enhance wound healing. The purpose of this study was to evaluate the effects of dHACM on periodontal healing, using in vitro and in vivo experimental approaches. Standardized periodontal defects were created in rats. The defects were randomly divided into three groups: Unfilled, filled with hydroxypropyl cellulose (HPC), and dHACM+HPC. At 2 and 4 weeks postoperatively, periodontal healing was analyzed by microcomputed tomography (micro-CT), and histological and immunohistochemical analyses. In vitro, periodontal ligament-derived cells (PDLCs) isolated from rat incisors were incubated with dHACM extract. Cell proliferation and migration were evaluated by WST-1 and wound healing assay. In vivo, micro-CT examination at 2 weeks revealed enhanced formation of new bone in the dHACM+HPC group. At 4 weeks, the proportions of vascular endothelial growth factor (VEGF)-positive cells and α-smooth muscle actin (α-SMA)-positive blood vessels in the dHACM+HPC group were significantly greater than those in the Unfilled group. In vitro, dHACM extracts at 100 µg/mL significantly increased cell proliferation and migration compared with control. These findings suggest that GFs contained in dHACM promote proliferation and migration of PDLCs and angiogenesis, which lead to enhanced periodontal healing.
- 9 April 2022
- Published by Wiley in Journal of Periodontology
- Vol. 93 (10) , 1468-1475
Evaluation of the accuracy of soft tissue thickness measurements with three different methodologies: An in vitro study
Background: Soft tissue thickness (STT) influences esthetics, peri‐implant, and periodontal health. Non‐invasive methods of STT evaluation include cone‐beam computed tomography (CBCT) with Digital Imaging and Communications in Medicine (DICOM) files and registration of DICOM files with an intraoral scan or Standard Tessellation Language (STL) files. This study compares three methodologies: bone sounding, DICOM data alone, and DICOM and STL registration to absolute histomorphologic values.Methods: Five human maxillas, including teeth numbers 6 to 11, provided 90 sites for analysis. For standardization, reference grooves were placed at the cervical margin and the long axis of each tooth. Direct measurements with a no. 25 K‐file were completed at the facial soft tissues at 3.00, 5.00, and 7.00 mm from the apical marginal reference. Indirect measures were performed with implant planning software. Histological measurements were rendered with imaging software. One‐way analysis of variance (ANOVA) was used to compare the three techniques for the differences from histologic measurements (α = 0.05).Results: Seventy‐two sites were included for final analysis. The overall mean histological STT (mSTT) was 0.73 ± 0.31 mm. Bone sounding overestimated mSTT, 0.22 ± 0.20 mm (P < 0.001); whereas, DICOM alone underestimated mSTT, −0.23 ± 0.19 mm (P < 0.001). DICOM and STL registration had non‐statistically significant differences, −0.04 ± 0.21 mm (P = 0.429). Intraclass correlation coefficient (ICC) of DICOM and STL registration achieved the highest agreement with histology (ICC: 0.74).Conclusions: DICOM and STL file registration had the highest agreement with histological STT supporting the use of DICOM and STL registration for the evaluation of STT.
- 9 April 2022
- Published by Wiley in Journal of Periodontology
- Vol. 93 (10) , 1468-1475
Evaluation of the accuracy of soft tissue thickness measurements with three different methodologies: An in vitro study
Background: Soft tissue thickness (STT) influences esthetics, peri‐implant, and periodontal health. Non‐invasive methods of STT evaluation include cone‐beam computed tomography (CBCT) with Digital Imaging and Communications in Medicine (DICOM) files and registration of DICOM files with an intraoral scan or Standard Tessellation Language (STL) files. This study compares three methodologies: bone sounding, DICOM data alone, and DICOM and STL registration to absolute histomorphologic values.Methods: Five human maxillas, including teeth numbers 6 to 11, provided 90 sites for analysis. For standardization, reference grooves were placed at the cervical margin and the long axis of each tooth. Direct measurements with a no. 25 K‐file were completed at the facial soft tissues at 3.00, 5.00, and 7.00 mm from the apical marginal reference. Indirect measures were performed with implant planning software. Histological measurements were rendered with imaging software. One‐way analysis of variance (ANOVA) was used to compare the three techniques for the differences from histologic measurements (α = 0.05).Results: Seventy‐two sites were included for final analysis. The overall mean histological STT (mSTT) was 0.73 ± 0.31 mm. Bone sounding overestimated mSTT, 0.22 ± 0.20 mm (P < 0.001); whereas, DICOM alone underestimated mSTT, −0.23 ± 0.19 mm (P < 0.001). DICOM and STL registration had non‐statistically significant differences, −0.04 ± 0.21 mm (P = 0.429). Intraclass correlation coefficient (ICC) of DICOM and STL registration achieved the highest agreement with histology (ICC: 0.74).Conclusions: DICOM and STL file registration had the highest agreement with histological STT supporting the use of DICOM and STL registration for the evaluation of STT.
- 2 December 2021
- Published by Wiley in Journal of Periodontology
- Vol. 93 (2) , E24-E33
An in vitro comparison of four antibacterial agents with and without nicotine and their effects on human gingival fibroblasts
Background: The purpose of the study was to compare anti‐bacterial activity of 0.12% chlorhexidine (CHX), 10% povidone iodine (PVD), Vega oral care gel (VEGA), and antioxidant gel (AO) on Streptococcus mutans, Streptococcus sanguis, Fusobacterium nucleatum, and Porphyromonas gingivalis with and without nicotine and to evaluate their effects on human gingival fibroblasts (HGFs).Methods: S. mutans, S. sanguis, P. gingivalis, and F. nucleatum were incubated with serial dilutions (1/4, 1/8, 1/16, 1/32, and 1/64) of anti‐bacterial agents in media (with and without nicotine). Minimum inhibitory and minimum bactericidal concentrations (MIC/MBC) were measured, and confocal microscopy was performed. HGFs were exposed to serial dilutions (1/10, 1/100, 1/1000, and 1/10,000) of antibacterial agents with media. Water‐soluble tetrazolium‐1 (WST‐1) assay and lactate dehydrogenase (LDH) assay were used to assess proliferation and cytotoxicity towards HGFs.Results: CHX and PVD significantly inhibited growth of all bacterial species (P < 0.0001) at all dilutions. AO and VEGA inhibited growth of all bacterial species up to only the 1/4 dilution. CHX and PVD decreased HGF proliferation at 1/10 and 1/100 dilution, whereas AO at all dilutions (P < 0.05). CHX and AO were cytotoxic at all dilutions (P < 0.05). VEGA was not cytotoxic to HGFs and did not affect HGF proliferation at any dilution (P > 0.05). An increased bacterial growth was seen for all species except P. gingivalis with addition of nicotine.Conclusion: CHX and PVD demonstrate superior antibacterial properties, but significantly reduce HGF proliferation. AO is bacteriostatic at lower dilutions but is highly toxic to HGFs. VEGA was bacteriostatic and demonstrated no detrimental effects on HGF's.
- 2 December 2021
- Published by Wiley in Journal of Periodontology
- Vol. 93 (2) , E24-E33
An in vitro comparison of four antibacterial agents with and without nicotine and their effects on human gingival fibroblasts
Background: The purpose of the study was to compare anti‐bacterial activity of 0.12% chlorhexidine (CHX), 10% povidone iodine (PVD), Vega oral care gel (VEGA), and antioxidant gel (AO) on Streptococcus mutans, Streptococcus sanguis, Fusobacterium nucleatum, and Porphyromonas gingivalis with and without nicotine and to evaluate their effects on human gingival fibroblasts (HGFs).Methods: S. mutans, S. sanguis, P. gingivalis, and F. nucleatum were incubated with serial dilutions (1/4, 1/8, 1/16, 1/32, and 1/64) of anti‐bacterial agents in media (with and without nicotine). Minimum inhibitory and minimum bactericidal concentrations (MIC/MBC) were measured, and confocal microscopy was performed. HGFs were exposed to serial dilutions (1/10, 1/100, 1/1000, and 1/10,000) of antibacterial agents with media. Water‐soluble tetrazolium‐1 (WST‐1) assay and lactate dehydrogenase (LDH) assay were used to assess proliferation and cytotoxicity towards HGFs.Results: CHX and PVD significantly inhibited growth of all bacterial species (P < 0.0001) at all dilutions. AO and VEGA inhibited growth of all bacterial species up to only the 1/4 dilution. CHX and PVD decreased HGF proliferation at 1/10 and 1/100 dilution, whereas AO at all dilutions (P < 0.05). CHX and AO were cytotoxic at all dilutions (P < 0.05). VEGA was not cytotoxic to HGFs and did not affect HGF proliferation at any dilution (P > 0.05). An increased bacterial growth was seen for all species except P. gingivalis with addition of nicotine.Conclusion: CHX and PVD demonstrate superior antibacterial properties, but significantly reduce HGF proliferation. AO is bacteriostatic at lower dilutions but is highly toxic to HGFs. VEGA was bacteriostatic and demonstrated no detrimental effects on HGF's.
- 2 August 2021
- Published by Wiley in Journal of Periodontology
- Vol. 93 (5) , 83-91
In vitro comparison of root surface roughness and bacterial adhesion following treatment with three different instruments
Background: A novel device, piezoelectric 11 Gracey curet tip, reportedly combines benefits of a piezoelectric device and manual curet. The primary objective of this study was to compare root surface roughness outcomes between traditional manual curets and piezoelectric devices, as compared with this novel device. The secondary aim was to assess the level of adhesion of Streptococcus mutans on the root surface after instrumentation.Methods: The groups consisted of the following: 1) Gracey curet; 2) piezoelectric scaler; 3) piezoelectric 11 Gracey curet tip; and 4) untreated control. Root specimens were obtained from extracted human teeth and randomly assigned to each group. Surface roughness measurements (Ra and Rz) were taken with a profilometer before and after instrumentation. After instrumentation, root specimens were inoculated with S. mutans and biofilm was dislodged. Various dilutions of resuspended biofilm were incubated on blood agar plates and colony forming units (CFU) values were measured.Results: The experimental device resulted in significantly lower Ra and Rz compared with other groups (P < 0.01), and the Gracey curet was significantly lower than the piezoelectric tip and untreated control (P < 0.05). The Gracey curet and experimental device tip had significantly lower CFU values compared with the control (P < 0.05). There were no significant CFU value differences between the Gracey curet and both the piezoelectric and experimental device tips. There were no significant CFU differences between piezoelectric tip and both experimental device and control. There was no correlation between Ra and CFU values for Gracey curet, piezoelectric tip, or the control. However, correlation between Ra values and CFU approached significance for the experimental device (correlation = 0.66, P = 0.05).Conclusions: Piezoelectric 11 Gracey curet tip is effective at resulting in a significantly smoother surface compared with traditional piezoelectric and hand instruments. CFU values with piezoelectric 11 Gracey curet tip were significantly lower than non‐instrumented surfaces, but there were no significant differences compared with conventional methods.
- 2 August 2021
- Published by Wiley in Journal of Periodontology
- Vol. 93 (5) , 83-91
In vitro comparison of root surface roughness and bacterial adhesion following treatment with three different instruments
Background: A novel device, piezoelectric 11 Gracey curet tip, reportedly combines benefits of a piezoelectric device and manual curet. The primary objective of this study was to compare root surface roughness outcomes between traditional manual curets and piezoelectric devices, as compared with this novel device. The secondary aim was to assess the level of adhesion of Streptococcus mutans on the root surface after instrumentation.Methods: The groups consisted of the following: 1) Gracey curet; 2) piezoelectric scaler; 3) piezoelectric 11 Gracey curet tip; and 4) untreated control. Root specimens were obtained from extracted human teeth and randomly assigned to each group. Surface roughness measurements (Ra and Rz) were taken with a profilometer before and after instrumentation. After instrumentation, root specimens were inoculated with S. mutans and biofilm was dislodged. Various dilutions of resuspended biofilm were incubated on blood agar plates and colony forming units (CFU) values were measured.Results: The experimental device resulted in significantly lower Ra and Rz compared with other groups (P < 0.01), and the Gracey curet was significantly lower than the piezoelectric tip and untreated control (P < 0.05). The Gracey curet and experimental device tip had significantly lower CFU values compared with the control (P < 0.05). There were no significant CFU value differences between the Gracey curet and both the piezoelectric and experimental device tips. There were no significant CFU differences between piezoelectric tip and both experimental device and control. There was no correlation between Ra and CFU values for Gracey curet, piezoelectric tip, or the control. However, correlation between Ra values and CFU approached significance for the experimental device (correlation = 0.66, P = 0.05).Conclusions: Piezoelectric 11 Gracey curet tip is effective at resulting in a significantly smoother surface compared with traditional piezoelectric and hand instruments. CFU values with piezoelectric 11 Gracey curet tip were significantly lower than non‐instrumented surfaces, but there were no significant differences compared with conventional methods.
- 1 February 2021
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 47 (1) , 25-29
Effect of Medical-Grade Polyurethane Sponges on Sinus Membrane Perforation With a Lateral Window Approach
The most commonly reported complication during the sinus elevation surgical procedure is the perforation of the Schneiderian membrane. The aim of this retrospective study was to compare the rate of sinus membrane perforation during lateral window augmentation using either conventional sinus curettes or medical-grade polyurethane sponges. This retrospective study included patients who received a lateral window approach for sinus floor elevation. The sinus elevation procedures using medical-grade polyurethane sponges (test) or conventional curettes (control) were recorded and analyzed. All subjects' demographic data and preexisting conditions were evaluated. A total of 38 procedures met inclusion criteria, and those data were evaluated for analysis. There were no statistically significant differences in demographic data or preexisting conditions including age, sex, treatment location, presence and absence of septum, Schneiderian membrane thickness, and residual bone height between test and control groups. The membrane perforation rate was 7% in the test group and 43% in the control group; however, this difference did not reach statistical significance (P = .064). Within the limitations of this study, although there was no statistically significant reduction of sinus membrane perforation with the use of medical-grade polyurethane sponges, the decreased incidence of perforation might be of clinical significance.
- 1 February 2021
- Published by American Academy of Implant Dentistry in Journal of Oral Implantology
- Vol. 47 (1) , 25-29
Effect of Medical-Grade Polyurethane Sponges on Sinus Membrane Perforation With a Lateral Window Approach
The most commonly reported complication during the sinus elevation surgical procedure is the perforation of the Schneiderian membrane. The aim of this retrospective study was to compare the rate of sinus membrane perforation during lateral window augmentation using either conventional sinus curettes or medical-grade polyurethane sponges. This retrospective study included patients who received a lateral window approach for sinus floor elevation. The sinus elevation procedures using medical-grade polyurethane sponges (test) or conventional curettes (control) were recorded and analyzed. All subjects' demographic data and preexisting conditions were evaluated. A total of 38 procedures met inclusion criteria, and those data were evaluated for analysis. There were no statistically significant differences in demographic data or preexisting conditions including age, sex, treatment location, presence and absence of septum, Schneiderian membrane thickness, and residual bone height between test and control groups. The membrane perforation rate was 7% in the test group and 43% in the control group; however, this difference did not reach statistical significance (P = .064). Within the limitations of this study, although there was no statistically significant reduction of sinus membrane perforation with the use of medical-grade polyurethane sponges, the decreased incidence of perforation might be of clinical significance.
- Open Access
- 14 January 2021
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 7 (4) , 436-442
Effects of platelet‐rich fibrin on human gingival and periodontal ligament fibroblast proliferation from chronic periodontitis versus periodontally healthy subjects
Background: Platelet‐rich fibrin (PRF), an autogenous blood concentrate, contains multiple growth factors and is used as an adjunct in the periodontal regeneration and implant site development procedures to stimulate wound healing. Patient‐related factors such as chronic periodontitis may affect the quality of PRF.Objectives: This study aimed to investigate and compare PRF's effects from patients diagnosed with generalized moderate or severe chronic periodontitis to patients who presented with intact periodontium on human gingival fibroblast (HGF) and human periodontal ligament fibroblast (HPLF) proliferation.Materials and methods: A total of 33 ml of whole intravenous blood was collected from each subject and centrifuged at 2700 rpm for 12 min in three 10 ml tubes, and 3 ml of blood was used for Complete Blood Count analysis. Three PRF clots were compressed to produce the membranes and liquid exudate. PRF membrane and 10% liquid exudate were exposed to 20,000 HPLFs/well or 25,000 HGFs/well in triplets from each subject in a 48 cell well plate. After 72 h of incubation, the conditioned media were evaluated by Water Soluble Tetrazolium‐1 assays to determine fibroblast proliferation. Controls included cells alone and media without cells. Complete blood counts were measured.Results: Subjects in both groups were age and gender‐matched (intact 46.7 ± 11.4 years and periodontitis 54.8 ± 10.4 years, p‐value = 0.1344). Body Mass Index and White Blood Corpuscles in the periodontitis group was significantly higher than the intact group (p = 0.0176 and p = 0.0038) whereas no differences were seen for Red Blood Corpuscles (p = 0.2020), Hemoglobin (p = 0.2290) and Platelets (p = 4,094). There were no significant differences in the HGF and HPLF proliferation with PRF exudates and membranes between intact periodontium and periodontitis groups (all p > 0.05). However, PRF exudates in both groups induced significant more cell proliferation when compared to PRF membranes.Conclusions: PRF exudates induced significant proliferation of fibroblasts and can play a vital role in wound healing. The current study concluded that PRF membranes, in combination with PRF exudates, can be utilized for their therapeutic and wound healing potential, not affected by the periodontal condition of the patient.
- 14 January 2021
- Published by Wiley in Clinical and Experimental Dental Research
- Vol. 7 (4) , 436-442
Open AccessEffects of platelet‐rich fibrin on human gingival and periodontal ligament fibroblast proliferation from chronic periodontitis versus periodontally healthy subjects
Background: Platelet‐rich fibrin (PRF), an autogenous blood concentrate, contains multiple growth factors and is used as an adjunct in the periodontal regeneration and implant site development procedures to stimulate wound healing. Patient‐related factors such as chronic periodontitis may affect the quality of PRF.Objectives: This study aimed to investigate and compare PRF's effects from patients diagnosed with generalized moderate or severe chronic periodontitis to patients who presented with intact periodontium on human gingival fibroblast (HGF) and human periodontal ligament fibroblast (HPLF) proliferation.Materials and methods: A total of 33 ml of whole intravenous blood was collected from each subject and centrifuged at 2700 rpm for 12 min in three 10 ml tubes, and 3 ml of blood was used for Complete Blood Count analysis. Three PRF clots were compressed to produce the membranes and liquid exudate. PRF membrane and 10% liquid exudate were exposed to 20,000 HPLFs/well or 25,000 HGFs/well in triplets from each subject in a 48 cell well plate. After 72 h of incubation, the conditioned media were evaluated by Water Soluble Tetrazolium‐1 assays to determine fibroblast proliferation. Controls included cells alone and media without cells. Complete blood counts were measured.Results: Subjects in both groups were age and gender‐matched (intact 46.7 ± 11.4 years and periodontitis 54.8 ± 10.4 years, p‐value = 0.1344). Body Mass Index and White Blood Corpuscles in the periodontitis group was significantly higher than the intact group (p = 0.0176 and p = 0.0038) whereas no differences were seen for Red Blood Corpuscles (p = 0.2020), Hemoglobin (p = 0.2290) and Platelets (p = 4,094). There were no significant differences in the HGF and HPLF proliferation with PRF exudates and membranes between intact periodontium and periodontitis groups (all p > 0.05). However, PRF exudates in both groups induced significant more cell proliferation when compared to PRF membranes.Conclusions: PRF exudates induced significant proliferation of fibroblasts and can play a vital role in wound healing. The current study concluded that PRF membranes, in combination with PRF exudates, can be utilized for their therapeutic and wound healing potential, not affected by the periodontal condition of the patient.