C. D. Graham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
C. D. Graham has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
B. E. Lorenz
Electrical Engineering Department, Widener University, Chester, Pennsylvania 19014
1 shared publicationB.E. Lorenz
1 shared publicationBryen E. Lorenz
Department of Electrical Engineering, Widener University, Chester, PA, USA
1 shared publication- M. R. J. Gibbs
Clinical Development, Vaccines & Immunotherapies, AstraZeneca, Cambridge, UK
1 shared publication
Latest Publications
- 1 July 2018
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 458, 15-18
Delta ferrite is ubiquitous in type 304 stainless steel: Consequences for magnetic characterization
- 1 July 2018
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 458, 15-18
Delta ferrite is ubiquitous in type 304 stainless steel: Consequences for magnetic characterization
- 21 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 43 (6) , 2743-2745
Experimental Demagnetizing Factors for Disk Samples Magnetized Along a Diameter
Demagnetizing factors for disk samples of a commercial 80Ni permalloy have been measured using a vibrating sample magnetometer with fields provided by a Helmholtz coil pair. The range of values of m (diameter/thickness) is from 12.5 to 385. The experimental values of N are significantly higher than those calculated for an ellipsoid, but lower than those calculated assuming uniform magnetization
- 21 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 43 (6) , 2743-2745
Experimental Demagnetizing Factors for Disk Samples Magnetized Along a Diameter
Demagnetizing factors for disk samples of a commercial 80Ni permalloy have been measured using a vibrating sample magnetometer with fields provided by a Helmholtz coil pair. The range of values of m (diameter/thickness) is from 12.5 to 385. The experimental values of N are significantly higher than those calculated for an ellipsoid, but lower than those calculated assuming uniform magnetization
- 1 August 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (8) , 2770-2772
Apparatus for high temperature magnetostriction measurement of bulk samples
A relatively simple and inexpensive apparatus for the measurement of magnetostriction in bulk samples at room temperature and above is described. A laser beam directed into a four-quadrant photodiode is partially blocked by the free end of the strip sample. When the sample changes length under the influence of an applied field, the output of the photodiode segments is unbalanced, producing a signal that is proportional to the change in length over a range of about . The laser beam is modulated at , and the photodiode signal measured with a lock-in amplifier. The sample can be moved vertically with a fine screw thread, which is used both for calibration and to offset the effect of thermal expansion. The samples are metallic strips long by about wide and generally about thick. They can be heated in air to a maximum temperature of about . The sensitivity of the apparatus is about at room temperature, falling to about at , which is adequate for strongly magnetostrictive materials. Measurements have been made on several alloys, as well as , , and alloys.- 1 August 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (8) , 2770-2772
Apparatus for high temperature magnetostriction measurement of bulk samples
A relatively simple and inexpensive apparatus for the measurement of magnetostriction in bulk samples at room temperature and above is described. A laser beam directed into a four-quadrant photodiode is partially blocked by the free end of the strip sample. When the sample changes length under the influence of an applied field, the output of the photodiode segments is unbalanced, producing a signal that is proportional to the change in length over a range of about . The laser beam is modulated at , and the photodiode signal measured with a lock-in amplifier. The sample can be moved vertically with a fine screw thread, which is used both for calibration and to offset the effect of thermal expansion. The samples are metallic strips long by about wide and generally about thick. They can be heated in air to a maximum temperature of about . The sensitivity of the apparatus is about at room temperature, falling to about at , which is adequate for strongly magnetostrictive materials. Measurements have been made on several alloys, as well as , , and alloys.- 1 November 1993
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 29 (6) , 3457-3459
High-field magnetization of metallic glasses
- 1 November 1993
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 29 (6) , 3457-3459
High-field magnetization of metallic glasses