RPRadhakrishna G. Pillai

Radhakrishna G. Pillai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Radhakrishna G. Pillai has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Influence of Fine Aggregate Characteristics on the Fresh and Mechanical Properties of Ultrahigh-Performance Concrete

    by Krishnan U. Ambikakumari Sanalkumar, M. Selvam, Surender Singh, Radhakrishna G. Pillai

    The present research examines two key challenges in ultrahigh-performance concrete (UHPC): reliance on proprietary mix designs; and the effects of fine aggregate morphology on the workability and mechanical properties of UHPC. This study aims to address scalability challenges in UHPC by developing mixes with locally available materials. A systematic mixing procedure was established to produce UHPC mixes achieving compressive strengths in the range of 100–175 MPa. These mixes incorporate supplementary cementitious materials such as ground granulated blast furnace slag and ultrafine slag, which were found to significantly improve mechanical performance and workability. Further, a comprehensive investigation was conducted to evaluate the role of sand morphology in UHPC using crushed sand (CS), quartz sand (QS), and river sand (RS) on packing density, hydration kinetics, flowability, and mechanical properties of UHPC. This study examined their effects on packing density, hydration kinetics, flowability, and mechanical properties. The results revealed that QS, characterized by smooth, spherical grains, significantly enhanced workability and achieved the highest 28-day compressive strength of 106 MPa, despite a lower packing density. In contrast, CS, with angular and rough-textured particles, exhibited higher packing density and improved interlocking; however, it led to lower strength (99 MPa). RS, composed of subangular grains with moderate angularity, showed limited interlocking capacity and achieved the lowest strength (91 MPa), though it provided acceptable workability. Micrographs from scanning electron microscopy revealed this paradox by showing crack propagation through microcracked CS grains, whereas the monolithic structure of QS exhibited resistance to fracture. These findings establish a practical framework for the design of UHPC mixtures using regionally sourced materials, while highlighting the critical role of fine aggregate morphology in governing the fresh and mechanical performance of UHPC.

  • A Study on Assessing the Performance of Galvanic Anodes in Patch Repair of Reinforced Concrete Slabs

    by Roopa Vijayaraghavan, M.S. Haji Sheik Mohammed, Radhakrishna G. Pillai

    Patch repair is one of the most adopted methods for repairing distressed reinforced concrete (RC) roof slabs. Galvanic anodes in the patch repair area can overcome the formation of incipient anodes and extend the service life of the repair work. This experimental study evaluates the protection criterion to assess the performance of galvanic anodes in patch repair regions. The potential and the current distribution in the RC slabs were monitored for 440 days. As per EN ISO 12696: 2022, the 100‐mV depolarisation potential criterion is not applicable for galvanic anodes embedded in the patch repair region. Alternatively, this paper explores the use of output current from the anode (anodic current) as a parameter to assess the performance of the galvanic anode. The reducing trend of corrosion current density values of steel rebar in the repair region over a period indicates the performance of galvanic anodes, and this was also validated using numerical simulation.


  • Passivation of Prestressed Steel in Concrete With Slag and Exposed to Chlorides

    by Sreelakshmi Srinivasan, Radhakrishna G. Pillai, Carmen Andrade

    The usage of slag in prestressed concrete remains contentious because of contradictory results on the early‐stage passivation behaviour of steel in concrete with slag. In this study, six lollipop test specimens with prestressing steel wire (with/without axial stress) in mortar blended with 50% ordinary Portland cement and 50% slag were prepared and then subjected to cyclic wet‐dry chloride exposure and repetitive electrochemical impedance spectroscopy tests. The changes in the resistance of the passive film were monitored for 1 year. These tests revealed that the presence of free sulphides in slag‐based mortar resulted in inadequate early passivation and higher susceptibility to chloride‐induced depassivation within a month. Notably, steel reinforcement in concrete structures may not always get exposed to chlorides at early stages. Long‐term laboratory tests mimicking this field scenario revealed that as time passed, slag systems hydrated further, steel developed good passivation, and even allowed repassivation at later stages (after a few months), resulting in improved corrosion resistance.


  • A Data-Driven Model to Predict the Self-healing Performance of Ultra High-Performance Concrete

    by Bin Xi, Aayush Upadhyay, Radakrishna G. Pillai, Liberato Ferrara

  • Open Access

    10-year natural carbonation data of concretes with limestone, fly ash, volcanic ash, and slag and exposed to tropical climate in India

    by Umesh Hule, Sundar Rathnarajan, Radhakrishna G. Pillai, Ravindra Gettu, Manu Santhanam


  • Corrosion and Its Control in Prestressed Concrete Structures

    by Radhakrishna G. Pillai, Karthikeyan Manickam, Dyana Joseline, Sreelakshmi Srinivasan

  • Galvanic Corrosion of Strands in Re-Grouted, Post-Tensioned Concrete Bridges

    by Karthikeyan Manickam, Radhakrishna G. Pillai

    Grouted, post-tensioned (PTD) concrete systems are widely used to construct bridges, typically with an anticipated corrosion-free service life of 100+ y. However, the usage of inadequate grout materials and grouting practices in PTD concrete systems have caused unwanted air voids in ducts, leading to strand/grout/air interface, carbonation of exposed grout layer, and localized corrosion of strands (say, within about 10 y to 20 y). Re-grouting of voids as a tendon repair strategy has led to accelerated galvanic corrosion of the portion of strands at the interface between the carbonated base grout and repair grout with different chemistry, raising concerns and reluctance in re-grouting of voids in tendons. This work focused on understanding and quantifying the galvanic corrosion at the interface of carbonated base grout and repair grout in a re-grouted tendon. The theoretical analysis based on mixed potential theory estimated a galvanic current density of approximately 2 µA/cm2 and showed that the galvanic coupling can increase the corrosion current density of the prestressing steel in the base grout by about two-fold. The study on prestressed steel in simulated solutions estimated a galvanic current density of approximately 20 µA/cm2. Then, the study on prestressing steel in grouts and the analytical simulation estimated galvanic current densities around 1.5 µA/cm2 to 2 µA/cm2 at 95% external relative humidity (ERH) and 25°C. A model relating the galvanic current density in grouted systems as a function of ERH was developed, which showed an exponential increase in the galvanic corrosion with an increase in ERH. Also, a case study showed that if the tendon anchorage region experiences 95% ERH for about 20 y, sufficient strand corrosion could happen, and structural behavior can change from ductile to brittle nature, which could be a serious concern for structures in the coastal zone.


  • Development of the Galvanic Anode Performance Test for Assessing the Longevity of Galvanic Anodes for Reinforced Concrete Structures

    by Deepak K. Kamde, Radhakrishna G. Pillai

    The NACE impact report (2016) states that nearly 50% of reinforced concrete (RC) structures experience major repair in about 10 y. The existing approach of patch repair does not address the root cause and may not be durable—resulting in re-repair and huge economic loss. Galvanic anodes (GAs) are gaining widespread acceptance to achieve maintenance-free repair life for a few decades. However, a few GAs with inadequate characteristics are prematurely failing (within a few months). There are no short-term test methods to evaluate the longevity of GAs. Therefore, this work focuses on developing a short-term test method (galvanic anode performance [GAP] test) to assess the longevity of GAs. For this, the GAP specimen was designed by simulating RC structures protected with cathodic protection systems as follows: (i) GA embedded in bedding mortar (i.e., anode), (ii) nichrome mesh (i.e., cathode simulating rebars in RC structures), (iii) position of anode and cathode, (iv) application of potential difference (0.5 V, 1 V, 5 V, 10 V, 20 V, and 30 V) to accelerate the degradation of GAs, and (v) electrolyte to simulate conductivity of concrete. Applied potentials >5 V could not capture the difference in characteristics of GAs. However, potential differences of 0.5 V, 1 V, and 5 V could show the true behavior of GAs in various exposure conditions. Then, an approach is proposed to evaluate the service life of GAs. Possible reasons for the premature failure of anodes were investigated by evaluating pH and pore volume of encapsulating mortar. The GAP test can help practicing engineers estimate the longevity of GAs.


  • Long-Term Natural Carbonation in Concretes with Fly Ash and Limestone Calcined Clay Systems

    by Sundar Rathnarajan, Umesh Hule, Radhakrishna G. Pillai, Ravindra Gettu