Jianyou Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jianyou Li has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Hiroya Tanaka
Keio Research Institute at SFC, Keio University, Fujisawa, Kanagawa 252-0882, Japan
2 shared publications - Kai-Ting Chien
Mackay Memorial Hospital
2 shared publications - Lei-Po Chen
Mackay Memorial Hospital
2 shared publications - Ting-Kuo Chang
Department of Orthopaedic Surgery, MacKay Memorial Hospital, Taipei City, Taiwan; Department of Medicine, Mackay Medical College, Taipei City, Taiwan
2 shared publications - Yan-Shiang Lian
Department of Orthopaedic Surgery, MacKay Memorial Hospital, Taipei City, Taiwan
2 shared publications - Yu-Ching Huang
Department of Orthopaedic Surgery, MacKay Memorial Hospital, Taipei City, Taiwan, China
2 shared publications
Latest Publications
- Open Access
- 9 January 2026
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 25
Comparison between novel unilateral uniportal endoscopic lumbar interbody fusion and conventional transforaminal lumbar interbody fusion for lumbar degenerative disease with bilateral symptoms: A 1-year follow-up retrospective cohort study
- 9 January 2026
- Published by Elsevier in North American Spine Society Journal (NASSJ)
- Vol. 25
Open AccessComparison between novel unilateral uniportal endoscopic lumbar interbody fusion and conventional transforaminal lumbar interbody fusion for lumbar degenerative disease with bilateral symptoms: A 1-year follow-up retrospective cohort study
- Open Access
- 25 May 2018
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 4 (1) , 1-21
Rapid customization system for 3D-printed splint using programmable modeling technique – a practical approach
Traditional splinting processes are skill dependent and irreversible, and patient satisfaction levels during rehabilitation are invariably lowered by the heavy structure and poor ventilation of splints. To overcome this drawback, use of the 3D-printing technology has been proposed in recent years, and there has been an increase in public awareness. However, application of 3D-printing technologies is limited by the low CAD proficiency of clinicians as well as unforeseen scan flaws within anatomic models. A programmable modeling tool has been employed to develop a semi-automatic design system for generating a printable splint model. The modeling process was divided into five stages, and detailed steps involved in construction of the proposed system as well as automatic thickness calculation, the lattice structure, and assembly method have been thoroughly described. The proposed approach allows clinicians to verify the state of the splint model at every stage, thereby facilitating adjustment of input content and/or other parameters to help solve possible modeling issues. A finite element analysis simulation was performed to evaluate the structural strength of generated models. A fit investigation was applied on fabricated splints and volunteers to assess the wearing experience. Manual modeling steps involved in complex splint designs have been programed into the proposed automatic system. Clinicians define the splinting region by drawing two curves, thereby obtaining the final model within minutes. The proposed system is capable of automatically patching up minor flaws within the limb model as well as calculating the thickness and lattice density of various splints. Large splints could be divided into three parts for simultaneous multiple printing. This study highlights the advantages, limitations, and possible strategies concerning application of programmable modeling tools in clinical processes, thereby aiding clinicians with lower CAD proficiencies to become adept with splint design process, thus improving the overall design efficiency of 3D-printed splints.
- 25 May 2018
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 4 (1) , 1-21
Open AccessRapid customization system for 3D-printed splint using programmable modeling technique – a practical approach
Traditional splinting processes are skill dependent and irreversible, and patient satisfaction levels during rehabilitation are invariably lowered by the heavy structure and poor ventilation of splints. To overcome this drawback, use of the 3D-printing technology has been proposed in recent years, and there has been an increase in public awareness. However, application of 3D-printing technologies is limited by the low CAD proficiency of clinicians as well as unforeseen scan flaws within anatomic models. A programmable modeling tool has been employed to develop a semi-automatic design system for generating a printable splint model. The modeling process was divided into five stages, and detailed steps involved in construction of the proposed system as well as automatic thickness calculation, the lattice structure, and assembly method have been thoroughly described. The proposed approach allows clinicians to verify the state of the splint model at every stage, thereby facilitating adjustment of input content and/or other parameters to help solve possible modeling issues. A finite element analysis simulation was performed to evaluate the structural strength of generated models. A fit investigation was applied on fabricated splints and volunteers to assess the wearing experience. Manual modeling steps involved in complex splint designs have been programed into the proposed automatic system. Clinicians define the splinting region by drawing two curves, thereby obtaining the final model within minutes. The proposed system is capable of automatically patching up minor flaws within the limb model as well as calculating the thickness and lattice density of various splints. Large splints could be divided into three parts for simultaneous multiple printing. This study highlights the advantages, limitations, and possible strategies concerning application of programmable modeling tools in clinical processes, thereby aiding clinicians with lower CAD proficiencies to become adept with splint design process, thus improving the overall design efficiency of 3D-printed splints.
- Open Access
- 11 January 2018
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 4 (1) , 1-15
Feasibility study applying a parametric model as the design generator for 3D–printed orthosis for fracture immobilization
Applying 3D printing technology for the fabrication of custom-made orthoses provides significant advantages, including increased ventilation and lighter weights. Currently, the design of such orthoses is most often performed in the CAD environment, but creating the orthosis model is a time-consuming process that requires significant CAD experience. This skill gap limits clinicians from applying this technology in fracture treatment. The purpose of this study is to develop a parametric model as the design generator for 3D–printed orthoses for an inexperienced CAD user and to evaluate its feasibility and ease of use via a training and design exercise. A set of automatic steps for orthosis modeling was developed as a parametric model using the Visual Programming Language in the CAD environment, and its interface and workflow were simplified to reduce the training period. A quick training program was formulated, and 5 participants from a nursing school completed the training within 15 mins. They verified its feasibility in an orthosis design exercise and designed 5 orthoses without assistance within 8 to 20 mins. The few faults and program errors that were observed in video analysis of the exercise showed improvable weaknesses caused by the scanning quality and modeling process. Compared to manual modeling instruction, this study highlighted the feasibility of using a parametric model for the design of 3D–printed orthoses and its greater ease of use for medical personnel compared to the CAD technique. The parametric model reduced the complex process of orthosis design to a few minutes, and a customized interface and training program accelerated the learning period. The results from the design exercise accurately reflect real-world situations in which an inexperienced user utilizes a generator as well as demonstrate the utility of the parametric model approach and strategy for training and interfacing.
- 11 January 2018
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 4 (1) , 1-15
Open AccessFeasibility study applying a parametric model as the design generator for 3D–printed orthosis for fracture immobilization
Applying 3D printing technology for the fabrication of custom-made orthoses provides significant advantages, including increased ventilation and lighter weights. Currently, the design of such orthoses is most often performed in the CAD environment, but creating the orthosis model is a time-consuming process that requires significant CAD experience. This skill gap limits clinicians from applying this technology in fracture treatment. The purpose of this study is to develop a parametric model as the design generator for 3D–printed orthoses for an inexperienced CAD user and to evaluate its feasibility and ease of use via a training and design exercise. A set of automatic steps for orthosis modeling was developed as a parametric model using the Visual Programming Language in the CAD environment, and its interface and workflow were simplified to reduce the training period. A quick training program was formulated, and 5 participants from a nursing school completed the training within 15 mins. They verified its feasibility in an orthosis design exercise and designed 5 orthoses without assistance within 8 to 20 mins. The few faults and program errors that were observed in video analysis of the exercise showed improvable weaknesses caused by the scanning quality and modeling process. Compared to manual modeling instruction, this study highlighted the feasibility of using a parametric model for the design of 3D–printed orthoses and its greater ease of use for medical personnel compared to the CAD technique. The parametric model reduced the complex process of orthosis design to a few minutes, and a customized interface and training program accelerated the learning period. The results from the design exercise accurately reflect real-world situations in which an inexperienced user utilizes a generator as well as demonstrate the utility of the parametric model approach and strategy for training and interfacing.
- 9 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 15 (5) , 1400-1405
Carrier Dynamics in UV InGaN Multiple Quantum Well Inverted Hexagonal Pits
The emission and recombination characteristics of UV or blue light emission from InGaN/GaN quantum well (QW) structures influenced by V-shaped pits have been investigated by near-field and time-resolved photoluminescence measurements. Localization of charge carriers due to the potential barriers caused by the V-shaped pit formation is observed to be modified by thermal excitation. Temperature dependence of recombination dynamics shows evidence of a more complex potential barrier produced by the inverted hexagonal pits embedded within the multiple QWs. The emission from the narrow V-shaped pit QWs shows anomalous temperature dependence behavior that is significantly different from the emission from c-plane QWs. The carrier recombination process in c-plane QWs is significantly longer ~ 5 ns compared to the ~ 1.5 ns in V-shaped pit QWs at low temperatures due to the larger piezoelectric fields in wider wells. At room temperature, the recombination lifetimes are comparable due to increased carrier separation and delocalization within the V-shaped pit QWs.
- 9 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 15 (5) , 1400-1405
Carrier Dynamics in UV InGaN Multiple Quantum Well Inverted Hexagonal Pits
The emission and recombination characteristics of UV or blue light emission from InGaN/GaN quantum well (QW) structures influenced by V-shaped pits have been investigated by near-field and time-resolved photoluminescence measurements. Localization of charge carriers due to the potential barriers caused by the V-shaped pit formation is observed to be modified by thermal excitation. Temperature dependence of recombination dynamics shows evidence of a more complex potential barrier produced by the inverted hexagonal pits embedded within the multiple QWs. The emission from the narrow V-shaped pit QWs shows anomalous temperature dependence behavior that is significantly different from the emission from c-plane QWs. The carrier recombination process in c-plane QWs is significantly longer ~ 5 ns compared to the ~ 1.5 ns in V-shaped pit QWs at low temperatures due to the larger piezoelectric fields in wider wells. At room temperature, the recombination lifetimes are comparable due to increased carrier separation and delocalization within the V-shaped pit QWs.