Spyros D. Masouros
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Spyros D. Masouros has a total of 111 co-authors. Here are the top co-authors by number of shared publications:
- Diagarajen Carpanen
Imperial College London
10 shared publications - Nicolas Newell
Department of Bioengineering, Imperial College London, United Kingdom
7 shared publications - Anthony Michael James Bull
Imperial College London
6 shared publications Iain A. Rankin
Department of Bioengineering, Imperial College London, UK
6 shared publicationsJonathan C. Clasper
Department of Bioengineering, Imperial College London, London, United Kingdom
6 shared publications- Thuy-Tien N. Nguyen
Department of Bioengineering, Imperial College London, UK
6 shared publications
Latest Publications
- Open Access
- 24 September 2026
- Published by Wiley in International Wound Journal
- Vol. 23 (10) , e71054
Lateral Pressure Application to the Seated Buttocks Largely Maintains Transcutaneous Gas Tensions at the Ischial Tuberosity in a Healthy Cohort
This study aimed to evaluate the physiological effectiveness of lateral pressure application in maintaining baseline transcutaneous oxygen (TcPO 2 ) and carbon dioxide (TcPCO 2 ) tensions in the buttocks during sitting, compared with a conventional static foam cushion. Secondary aims were to determine whether body mass index (BMI) influenced the physiological response when lateral pressure was applied and to investigate the relationship between transcutaneous oximetry and underbody interface pressure. A prospective, controlled, repeated‐measures laboratory study was conducted with 30 healthy adults. Participants underwent two 20‐min sitting conditions: sitting on static foam alone and sitting on static foam with lateral pressure applied by a prototype device. Transcutaneous gas tensions were measured at the right ischial tuberosity using an oximeter and normalised to unloaded standing baselines. Tissue responses were categorised according to the Chai and Bader tissue‐response criteria, where changes in gas tensions of < 25% are Category 1, least risk, and changes of > 25% are Category 3, highest risk. Underbody interface pressures were recorded using a pressure‐mapping array. Statistical comparisons between conditions were performed using paired parametric or non‐parametric tests as appropriate. Mean and peak underbody interface pressures were significantly reduced ( p < 0.0001) when lateral pressure was applied. Lateral pressure significantly reduced the mean change in TcPCO 2 compared to static foam alone (11.9% ± 25.6% and 47.8% ± 72.9%, respectively, p < 0.0001) and reduced the change in TcPO 2 to −29.5% ± 23.5% compared to −50.4% ± 34.8% with static foam alone ( p < 0.0001). Eleven participants exhibited a Category 3 ischaemic response on static foam, compared with only two when lateral pressure was applied. Twenty‐nine of 30 participants moved to a more favourable or unchanged tissue‐response category when lateral pressure was applied. No correlation was found between interface pressure and changes in gas tensions. No significant differences were observed between BMI groups. Application of lateral pressure during sitting maintained tissue perfusion at the ischial tuberosity more effectively than static foam alone. These findings support the physiological rationale for applying lateral pressure as a novel strategy for pressure‐ulcer prevention in seated patients.
- 24 September 2026
- Published by Wiley in International Wound Journal
- Vol. 23 (10) , e71054
Open AccessLateral Pressure Application to the Seated Buttocks Largely Maintains Transcutaneous Gas Tensions at the Ischial Tuberosity in a Healthy Cohort
This study aimed to evaluate the physiological effectiveness of lateral pressure application in maintaining baseline transcutaneous oxygen (TcPO 2 ) and carbon dioxide (TcPCO 2 ) tensions in the buttocks during sitting, compared with a conventional static foam cushion. Secondary aims were to determine whether body mass index (BMI) influenced the physiological response when lateral pressure was applied and to investigate the relationship between transcutaneous oximetry and underbody interface pressure. A prospective, controlled, repeated‐measures laboratory study was conducted with 30 healthy adults. Participants underwent two 20‐min sitting conditions: sitting on static foam alone and sitting on static foam with lateral pressure applied by a prototype device. Transcutaneous gas tensions were measured at the right ischial tuberosity using an oximeter and normalised to unloaded standing baselines. Tissue responses were categorised according to the Chai and Bader tissue‐response criteria, where changes in gas tensions of < 25% are Category 1, least risk, and changes of > 25% are Category 3, highest risk. Underbody interface pressures were recorded using a pressure‐mapping array. Statistical comparisons between conditions were performed using paired parametric or non‐parametric tests as appropriate. Mean and peak underbody interface pressures were significantly reduced ( p < 0.0001) when lateral pressure was applied. Lateral pressure significantly reduced the mean change in TcPCO 2 compared to static foam alone (11.9% ± 25.6% and 47.8% ± 72.9%, respectively, p < 0.0001) and reduced the change in TcPO 2 to −29.5% ± 23.5% compared to −50.4% ± 34.8% with static foam alone ( p < 0.0001). Eleven participants exhibited a Category 3 ischaemic response on static foam, compared with only two when lateral pressure was applied. Twenty‐nine of 30 participants moved to a more favourable or unchanged tissue‐response category when lateral pressure was applied. No correlation was found between interface pressure and changes in gas tensions. No significant differences were observed between BMI groups. Application of lateral pressure during sitting maintained tissue perfusion at the ischial tuberosity more effectively than static foam alone. These findings support the physiological rationale for applying lateral pressure as a novel strategy for pressure‐ulcer prevention in seated patients.
- Open Access
- 27 May 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 181, 107479
Non-linear stiffness and damping properties of human intervertebral discs in compression and flexion at high-rates of loading
- 27 May 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 181, 107479
Open AccessNon-linear stiffness and damping properties of human intervertebral discs in compression and flexion at high-rates of loading
- Open Access
- 2 March 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (3) , e0341618
Evaluation of peripheral intravenous line securement devices under clinically relevant loading and perspiratory conditions
Peripheral vascular access devices (PVADs) and their associated intravenous (IV) lines are widely used in clinical care. Securement devices are typically employed to prevent accidental dislodgement and complications such as occlusion and phlebitis. Despite the wide use of securement devices, there are no standardised methods for evaluating their actual ability to secure IV lines. This study assessed the securing ability of four commercially available IV line securement devices – Grip Lok, Javelo, micropore tape, and IV bracelet – under controlled laboratory conditions. First, all four devices were tested for resistance to axial pull-out forces using a uniaxial materials testing machine across ten participants. Participant comfort during testing was assessed via questionnaire. Grip-Lok and Javelo exhibited significantly greater axial pull-out strength than the other two devices (p-adj < 0.001), and were progressed to further testing, consisting of off-axis loading at 90°, 135°, and peel-off, and axial pull-out under simulated perspiration conditions. No significant differences were observed between Grip Lok and Javelo under loading in 90° and 135°. Javelo demonstrated superior performance in both peel-off and perspirant conditions (p-adj < 0.05). Javelo was rated the most comfortable by 60% of participants. The results highlight the need for incorporating realistic loading conditions and comfort metrics when evaluating the performance of infusion line securement aids. Furthermore, the results provide evidence that using a non-adhesive based device, particularly in patients with marked diaphoresis might provide more infusion line security, though further study is required.
- 2 March 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (3) , e0341618
Open AccessEvaluation of peripheral intravenous line securement devices under clinically relevant loading and perspiratory conditions
Peripheral vascular access devices (PVADs) and their associated intravenous (IV) lines are widely used in clinical care. Securement devices are typically employed to prevent accidental dislodgement and complications such as occlusion and phlebitis. Despite the wide use of securement devices, there are no standardised methods for evaluating their actual ability to secure IV lines. This study assessed the securing ability of four commercially available IV line securement devices – Grip Lok, Javelo, micropore tape, and IV bracelet – under controlled laboratory conditions. First, all four devices were tested for resistance to axial pull-out forces using a uniaxial materials testing machine across ten participants. Participant comfort during testing was assessed via questionnaire. Grip-Lok and Javelo exhibited significantly greater axial pull-out strength than the other two devices (p-adj < 0.001), and were progressed to further testing, consisting of off-axis loading at 90°, 135°, and peel-off, and axial pull-out under simulated perspiration conditions. No significant differences were observed between Grip Lok and Javelo under loading in 90° and 135°. Javelo demonstrated superior performance in both peel-off and perspirant conditions (p-adj < 0.05). Javelo was rated the most comfortable by 60% of participants. The results highlight the need for incorporating realistic loading conditions and comfort metrics when evaluating the performance of infusion line securement aids. Furthermore, the results provide evidence that using a non-adhesive based device, particularly in patients with marked diaphoresis might provide more infusion line security, though further study is required.
- Open Access
- 17 February 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1685410
A custom force plate for quantifying the force applied by the finger during smartphone usage
Introduction: The increase in thumb activity due to smartphone use in recent years may be associated with an elevated risk of developing musculoskeletal disorders. Prior studies on hand biomechanics during touchscreen use have indicated that activities such as swiping and tapping lead to varying levels of muscle activation and ranges of motion. Currently, however, there is no device that can be used readily to measure finger forces accurately during smartphone use. Method: This study presents the design of a portable force plate specifically developed to quantify fingertip forces during smartphone use. The device utilises a load-cell structure and foil strain gauges to measure applied force magnitude, direction, and location. Results: The device achieved a force sensitivity of 0.15 N and a positional sensitivity of 2.5 mm, with a maximum measurable force capacity of 3 N. Discussion: The portable force plate enables the study of hand kinetics whilst allowing for physiological kinematics during smartphone use, with applications spanning musculoskeletal and finite-element model development of the hand, ergonomic risk assessment, smartphone interface evaluation, and musculoskeletal injury prevention.
- 17 February 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1685410
Open AccessA custom force plate for quantifying the force applied by the finger during smartphone usage
Introduction: The increase in thumb activity due to smartphone use in recent years may be associated with an elevated risk of developing musculoskeletal disorders. Prior studies on hand biomechanics during touchscreen use have indicated that activities such as swiping and tapping lead to varying levels of muscle activation and ranges of motion. Currently, however, there is no device that can be used readily to measure finger forces accurately during smartphone use. Method: This study presents the design of a portable force plate specifically developed to quantify fingertip forces during smartphone use. The device utilises a load-cell structure and foil strain gauges to measure applied force magnitude, direction, and location. Results: The device achieved a force sensitivity of 0.15 N and a positional sensitivity of 2.5 mm, with a maximum measurable force capacity of 3 N. Discussion: The portable force plate enables the study of hand kinetics whilst allowing for physiological kinematics during smartphone use, with applications spanning musculoskeletal and finite-element model development of the hand, ergonomic risk assessment, smartphone interface evaluation, and musculoskeletal injury prevention.
- Open Access
- 7 June 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (8) , 3294-3303
Endplate preparation for anterior cervical discectomy and fusion: does the amount of endplate removed affect cage subsidence risk?
Purpose: Subsidence after anterior cervical discectomy and fusion (ACDF) is a common complication that may be influenced by the degree of endplate removal prior to cage insertion. The optimal degree of endplate removal remains unclear; therefore, we performed a series of ex vivo experiments to elucidate the relationship between the aggressiveness of endplate preparation and subsidence risk. Methods: Human cadaveric subaxial cervical endplates were partially decorticated either conservatively (n = 10) or aggressively (n = 9). The degree of endplate removal was quantified using microCT. Subsidence was modelled by measuring the strength and stiffness of each specimen when an interbody cage was axially compressed into the endplate. Results: Conservative endplate preparation resulted in less endplate removal than aggressive endplate preparation (mass: 150 vs. 301 mg, p < 0.001; volume: 47 vs. 88mm3, p = 0.01; thickness: 0.02 vs. 0.16 mm, p = 0.004). There was no significant difference between the two groups with respect to endplate strength (2.04 vs. 2.04kN, p = 0.99) or stiffness (2.38 vs. 2.41kN/mm, p = 0.89). Bone mineral density (BMD) was similar between the two groups (271.6 vs. 271.9 mg/cm3, p = 0.98) but positively correlated with endplate strength (effect size 0.68, p = 0.001). Conclusions: When performing partial cervical endplate decortication, the degree of bony endplate removal did not significantly predict endplate integrity during ex vivo compression testing, but greater BMD was associated with increased strength. The degree of endplate removal should be based on individual patient factors and intraoperative findings to achieve the ideal cage-endplate interface.
- 7 June 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (8) , 3294-3303
Open AccessEndplate preparation for anterior cervical discectomy and fusion: does the amount of endplate removed affect cage subsidence risk?
Purpose: Subsidence after anterior cervical discectomy and fusion (ACDF) is a common complication that may be influenced by the degree of endplate removal prior to cage insertion. The optimal degree of endplate removal remains unclear; therefore, we performed a series of ex vivo experiments to elucidate the relationship between the aggressiveness of endplate preparation and subsidence risk. Methods: Human cadaveric subaxial cervical endplates were partially decorticated either conservatively (n = 10) or aggressively (n = 9). The degree of endplate removal was quantified using microCT. Subsidence was modelled by measuring the strength and stiffness of each specimen when an interbody cage was axially compressed into the endplate. Results: Conservative endplate preparation resulted in less endplate removal than aggressive endplate preparation (mass: 150 vs. 301 mg, p < 0.001; volume: 47 vs. 88mm3, p = 0.01; thickness: 0.02 vs. 0.16 mm, p = 0.004). There was no significant difference between the two groups with respect to endplate strength (2.04 vs. 2.04kN, p = 0.99) or stiffness (2.38 vs. 2.41kN/mm, p = 0.89). Bone mineral density (BMD) was similar between the two groups (271.6 vs. 271.9 mg/cm3, p = 0.98) but positively correlated with endplate strength (effect size 0.68, p = 0.001). Conclusions: When performing partial cervical endplate decortication, the degree of bony endplate removal did not significantly predict endplate integrity during ex vivo compression testing, but greater BMD was associated with increased strength. The degree of endplate removal should be based on individual patient factors and intraoperative findings to achieve the ideal cage-endplate interface.
- Open Access
- 3 May 2025
- Published by Elsevier in Journal of Tissue Viability
- Vol. 34 (3) , 100920
The ability of three pressure-ulcer prevention support-surfaces to maintain physiological transcutaneous gas tensions in the seated patient
- 3 May 2025
- Published by Elsevier in Journal of Tissue Viability
- Vol. 34 (3) , 100920
Open AccessThe ability of three pressure-ulcer prevention support-surfaces to maintain physiological transcutaneous gas tensions in the seated patient
- Open Access
- 15 April 2025
- Published by BMJ in BMJ Military Health
- Vol. 172 (4) , 348-352
Assessment of proprietary and improvised pelvic binders: time to application and displacement during casualty evacuation
Introduction: Pelvic injuries resulting from high-energy trauma have an approximately 10% mortality rate. Suspected pelvic injuries are treated with pelvic binders to stabilise fractured bones and promote tamponade until surgical treatment. The effectiveness of pelvic binders in reducing mortality risk depends on accurate positioning of the binder. This study quantifies the ability of proprietary and improvised pelvic binders to maintain their positioning during a simulated casualty evacuation. Methods: One improvised and three proprietary pelvic binders were tested in their ability to maintain their initial placement. Combat Medical Technicians applied binders to healthy subjects and then performed a simulated casualty evacuation. The time taken to apply each binder was measured. The evacuation consisted of: 20 m casualty drag, transfer onto a soft stretcher, 100 m evacuation on a soft stretcher, transfer onto a rigid stretcher and transfer into a field ambulance. Binder placement was measured using bony landmarks after the initial positioning and after each phase of the simulated casualty evacuation. Results: The field-expedient pelvic splint (FEPS), SAM Pelvic Sling II (SAM) and T-POD Pelvic Stabilisation Device (TPOD) all remained within 45 mm of vertical displacement from their initial placement, which is considered an acceptable range for optimal binder functionality. The Prometheus Pelvic Splint (PROM) fell within this range in 83% of trials. The SAM was the fastest binder to apply, followed by the TPOD, and then the FEPS and PROM which took similar times to apply. Conclusions: Binders were mostly able to maintain their positioning during the simulated casualty evacuations carried out in this study but differed in their application times. The improvised binder (FEPS) performed comparably to the proprietary binders tested, and its low cost and weight make it a good alternative to proprietary binders in the austere environment.
- 15 April 2025
- Published by BMJ in BMJ Military Health
- Vol. 172 (4) , 348-352
Open AccessAssessment of proprietary and improvised pelvic binders: time to application and displacement during casualty evacuation
Introduction: Pelvic injuries resulting from high-energy trauma have an approximately 10% mortality rate. Suspected pelvic injuries are treated with pelvic binders to stabilise fractured bones and promote tamponade until surgical treatment. The effectiveness of pelvic binders in reducing mortality risk depends on accurate positioning of the binder. This study quantifies the ability of proprietary and improvised pelvic binders to maintain their positioning during a simulated casualty evacuation. Methods: One improvised and three proprietary pelvic binders were tested in their ability to maintain their initial placement. Combat Medical Technicians applied binders to healthy subjects and then performed a simulated casualty evacuation. The time taken to apply each binder was measured. The evacuation consisted of: 20 m casualty drag, transfer onto a soft stretcher, 100 m evacuation on a soft stretcher, transfer onto a rigid stretcher and transfer into a field ambulance. Binder placement was measured using bony landmarks after the initial positioning and after each phase of the simulated casualty evacuation. Results: The field-expedient pelvic splint (FEPS), SAM Pelvic Sling II (SAM) and T-POD Pelvic Stabilisation Device (TPOD) all remained within 45 mm of vertical displacement from their initial placement, which is considered an acceptable range for optimal binder functionality. The Prometheus Pelvic Splint (PROM) fell within this range in 83% of trials. The SAM was the fastest binder to apply, followed by the TPOD, and then the FEPS and PROM which took similar times to apply. Conclusions: Binders were mostly able to maintain their positioning during the simulated casualty evacuations carried out in this study but differed in their application times. The improvised binder (FEPS) performed comparably to the proprietary binders tested, and its low cost and weight make it a good alternative to proprietary binders in the austere environment.
- 10 February 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 165, 106936
Experimental model and simulant for studying blast penetrating injury to the skin
- 10 February 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 165, 106936
Experimental model and simulant for studying blast penetrating injury to the skin
- 11 January 2025
- Published by BMJ in BMJ Military Health
- Vol. 171 (6) , 492-499
Whole body vibrations and lower back pain: a systematic review of the current literature
Introduction: Whole body vibration (WBV) is thought to be associated with low back pain (LBP). To mitigate against this the International Organisation for Standardisation (ISO) have created the ISO 2631 standard, recommending safe dose limits. The aim of this research is to conduct a systematic review of available literature addressing the question, is WBV associated with LBP? Methods: A literature search was performed from January 1970 until April 2022, including studies focusing on LBP and sciatica in association with WBV, looking specifically for ones reporting on military populations. Studies on populations less than 18 years old or case studies were excluded. We conducted two subgroup analyses on studies that used a validated method to assess LBP and measured an A(8) (daily exposure) or VDV value (highest vibration exposure) as per ISO 2631-1 standard. Results: 37 studies were included, 11 showed an association between LBP and WBV. 97.9% of the population was male with an average age of 40.2, 47% used a version of the Standard Nordic Questionnaire (SNQ) to assess LBP and 51% used a triaxial accelerometer standard to measure vibration. Two studies reported on military populations. The subgroup analysis for A(8) identified six studies with a total population of 1413. A(8) ranged from 0.17 m/s 2 to 0.59 m/s 2 and LBP prevalence from 25% to 66%. The subgroup analysis for VDV identified three papers with a total population of 1239. VDV ranged from 6.84 m/s 0.75 to 14.7 m/s 0.75 and LBP prevalence from 25% to 60.9%. Discussion: This paper suggests WBV and LBP are associated but there is a research gap for high-level evidence and comparable data. The use of the SNQ was a preferrable method to assess LBP in most included studies. Using this in combination with a protocolised standard for measuring vibration exposure is needed for further research. PROSPERO registration number: CRD42022298283.
- 11 January 2025
- Published by BMJ in BMJ Military Health
- Vol. 171 (6) , 492-499
Whole body vibrations and lower back pain: a systematic review of the current literature
Introduction: Whole body vibration (WBV) is thought to be associated with low back pain (LBP). To mitigate against this the International Organisation for Standardisation (ISO) have created the ISO 2631 standard, recommending safe dose limits. The aim of this research is to conduct a systematic review of available literature addressing the question, is WBV associated with LBP? Methods: A literature search was performed from January 1970 until April 2022, including studies focusing on LBP and sciatica in association with WBV, looking specifically for ones reporting on military populations. Studies on populations less than 18 years old or case studies were excluded. We conducted two subgroup analyses on studies that used a validated method to assess LBP and measured an A(8) (daily exposure) or VDV value (highest vibration exposure) as per ISO 2631-1 standard. Results: 37 studies were included, 11 showed an association between LBP and WBV. 97.9% of the population was male with an average age of 40.2, 47% used a version of the Standard Nordic Questionnaire (SNQ) to assess LBP and 51% used a triaxial accelerometer standard to measure vibration. Two studies reported on military populations. The subgroup analysis for A(8) identified six studies with a total population of 1413. A(8) ranged from 0.17 m/s 2 to 0.59 m/s 2 and LBP prevalence from 25% to 66%. The subgroup analysis for VDV identified three papers with a total population of 1239. VDV ranged from 6.84 m/s 0.75 to 14.7 m/s 0.75 and LBP prevalence from 25% to 60.9%. Discussion: This paper suggests WBV and LBP are associated but there is a research gap for high-level evidence and comparable data. The use of the SNQ was a preferrable method to assess LBP in most included studies. Using this in combination with a protocolised standard for measuring vibration exposure is needed for further research. PROSPERO registration number: CRD42022298283.
- Open Access
- 18 October 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1477405
A novel strain-based bone-fracture healing algorithm is able to predict a range of healing outcomes
Fracture healing is a complex process which sometimes results in non-unions, leading to prolonged disability and high morbidity. Traditional methods of optimising fracture treatments, such as in vitro benchtop testing and in vivo randomised controlled trials, face limitations, particularly in evaluating the entire healing process. This study introduces a novel, strain-based fracture-healing algorithm designed to predict a wide range of healing outcomes, including both successful unions and non-unions. The algorithm uses principal strains as mechanical stimuli to simulate fracture healing in response to local mechanical environments within the callus region. The model demonstrates good agreement with experimental data from ovine metatarsal osteotomies across six fracture cases with varying gap widths and inter-fragmentary strains, replicates physiological bony growth patterns, and is independent of the initial callus geometry. This computational approach provides a framework for developing new fracture-fixation devices, aid in pre-surgical planning, and optimise rehabilitation strategies.
- 18 October 2024
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1477405
Open AccessA novel strain-based bone-fracture healing algorithm is able to predict a range of healing outcomes
Fracture healing is a complex process which sometimes results in non-unions, leading to prolonged disability and high morbidity. Traditional methods of optimising fracture treatments, such as in vitro benchtop testing and in vivo randomised controlled trials, face limitations, particularly in evaluating the entire healing process. This study introduces a novel, strain-based fracture-healing algorithm designed to predict a wide range of healing outcomes, including both successful unions and non-unions. The algorithm uses principal strains as mechanical stimuli to simulate fracture healing in response to local mechanical environments within the callus region. The model demonstrates good agreement with experimental data from ovine metatarsal osteotomies across six fracture cases with varying gap widths and inter-fragmentary strains, replicates physiological bony growth patterns, and is independent of the initial callus geometry. This computational approach provides a framework for developing new fracture-fixation devices, aid in pre-surgical planning, and optimise rehabilitation strategies.