WJWoo-Lam Jo

Woo-Lam Jo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Woo-Lam Jo has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Is Total Hip Arthroplasty Feasible in Patients with Severe Preoperative Thrombocytopenia Managed by a Structured Perioperative Protocol? A Propensity Score-Matched Cohort Study

    by Jong Min Park, Jae Hak Lim, Ji Hoon Bahk, Woo Lam Jo, Saad Mohammed AlShammari, Young Wook Lim

    Background/Objectives: Total hip arthroplasty (THA) routinely produces perioperative blood loss of 800–1200 mL, which raises concern that patients with thrombocytopenia may be at substantially higher surgical risk. Evidence on THA safety in this population, however, remains scarce. We compared perioperative and functional outcomes of THA between patients with preoperative platelet counts below 80 × 109 cells/L and propensity score-matched controls with normal counts. Methods: In this retrospective matched cohort study, we reviewed 972 consecutive primary THAs. From this cohort, 30 patients with baseline platelet counts below 80 × 109 cells/L were identified and matched 1:2 with 60 control patients who had normal platelet counts (≥150 × 109 cells/L) using 1:2 nearest-neighbor matching. For all patients in the thrombocytopenic group, platelet counts were corrected to above 80 × 109 cells/L prior to surgery; thus, the study evaluates outcomes after preoperative hematologic optimization rather than surgery performed at uncorrected thrombocytopenic levels. All patients were closely monitored for at least one week postoperatively to evaluate complications and clinical outcomes. Results: Operative time (78.2 vs. 78.8 min, p = 0.898), estimated blood loss (492 vs. 505 mL, p = 0.821), hematoma rate (6.7% vs. 1.7%, p = 0.257), surgical site infection (6.7% vs. 1.7%, p = 0.257), and Harris Hip Scores (86.1 vs. 85.7, p = 0.615) did not differ significantly between groups, although the absolute wound-complication rates were numerically about four-fold higher in the thrombocytopenic group and the small sample limited statistical power. The study group did require more packed red blood cell transfusions (7.43 vs. 1.4 units, p < 0.001) and had longer hospital stays (9.8 vs. 6.0 days, p = 0.017). Conclusions: When severe preoperative thrombocytopenia is corrected to above 80 × 109 cells/L and managed with a structured perioperative protocol—meticulous intraoperative hemostasis and close postoperative surveillance for re-bleeding—THA can be performed with acceptable wound complication rates and functional outcomes and without catastrophic hemorrhage. Transfusion requirements and hospital stay remain higher, and the small sample size precludes concluding that the risk of infrequent complications is equivalent to that of patients with normal platelet counts. THA is therefore feasible, rather than unequivocally safe, under careful hematologic optimization.

  • Results of Cementless Total Hip Arthroplasty Using Third-Generation Ceramic-On-Ceramic Bearings: A Minimum 15-Year Follow-Up

    by Ji Hoon Bahk, Woo-Lam Jo, Kee-Haeng Lee, Joo-Hyoun Song, Seung-Chan Kim, Young Wook Lim

  • Open Access

    Short-Term Outcomes of Cementless Total Hip Arthroplasty Using a 3D-Printed Acetabular Cup Manufactured by Directed Energy Deposition: A Prospective Observational Study

    by Ji Hoon Bahk, Woo-Lam Jo, Kee-Haeng Lee, Joo-Hyoun Song, Seung-Chan Kim, Young Wook Lim

    Background/Objectives: Additive manufacturing (AM) enables the production of cementless acetabular cups with porous surfaces that facilitate early osseointegration. Directed energy deposition (DED), a form of AM, allows the direct welding of porous structures onto metal substrates without requiring a vacuum environment, offering advantages over conventional powder bed fusion methods. Despite growing interest in DED, no prospective clinical studies evaluating DED-based acetabular components have been published to date. This study assessed short-term outcomes of a DED-based 3D-printed acetabular cup in total hip arthroplasty (THA). Methods: A total of 120 patients who underwent primary cementless THA using the Corentec Mirabo Z® acetabular cup were prospectively enrolled. Among them, 124 hips from 100 patients who had completed a minimum of 24 months of follow-up were included in the analysis. Clinical outcomes were assessed using the Harris hip score (HHS), WOMAC, EQ-5D-5L, and pain NRS. Radiographic evaluation included measurements of cup position, osseointegration, and detection of interfacial or polar gaps on CT and plain radiographs. Implant-related complications were also recorded. Results: At a mean follow-up of 34.6 months, the implant survival rate was 99.3%, with one revision due to suspected osseointegration failure. The HHS improved from 56.6 to 91.4 at 24 months, and the NRS decreased from 6.2 to 1.1 (both p < 0.001). Interfacial gaps were observed in 58.1% of cases on CT, though most were <1 mm and not clinically significant. Common postoperative issues included greater trochanteric pain syndrome, squeaking, and iliotibial band tightness, all of which were resolved with conservative treatment. Conclusions: DED-based 3D-printed acetabular cups demonstrated favorable short-term clinical and radiographic outcomes, with high survivorship and reliable early osseointegration in cementless THA.


  • Open Access

    Prevalence of Venous Thromboembolism after Immediate Screening in Hip Fracture Patients

    by Yoon-Vin Kim, Joo-Hyoun Song, Young-Wook Lim, Woo-Lam Jo, Seung-Hun Ha, Kee-Haeng Lee

    Yoon-Vin Kim, MD, Joo-Hyoun Song, MD, PhD, Young-Wook Lim, MD, PhD, Woo-Lam Jo, MD, PhD, Seung-Hun Ha, MD, Kee-Haeng Lee, MD, PhD. Hip Pelvis 2024;36:47-54. https://doi.org/10.5371/hp.2024.36.1.47


  • Open Access

    Reliability of the 2018 Revised Version of AO/OTA Classification for Femoral Shaft Fractures

    by Jung-Wee Park, Woo-Lam Jo, Byung Kyu Park, Jong Jin Go, Minji Han, Sungha Chun, Young-Kyun Lee

    Park JW, et al. Clin Orthop Surg. 2024 Oct;16(5):688-693. https://doi.org/10.4055/cios23292


  • Open Access

    Effects of Thrombin-Based Hemostatic Agent in Total Knee Arthroplasty: Meta-Analysis

    by Jung-Wee Park, Tae Woo Kim, Chong Bum Chang, Minji Han, Jong Jin Go, Byung Kyu Park, Woo-Lam Jo, Young-Kyun Lee

    The effectiveness of Floseal, a thrombin-based hemostatic matrix, in total knee arthroplasty (TKA) in minimizing blood loss and transfusion requirements remains a topic of debate. This meta-analysis aims to evaluate the up-to-date randomized controlled trials (RCTs) on the efficacy and safety of Floseal in TKA. A comprehensive search was conducted in electronic databases to identify relevant RCTs. The methodological quality of the included studies was assessed, and data extraction was performed. The pooled effect sizes were calculated using standardized mean difference (SMD) or odds ratios (OR) with 95% confidence intervals (CIs). Eight studies involving 904 patients were included in the meta-analysis. The use of a thrombin-based hemostatic agent significantly reduced hemoglobin decline (SMD = −0.49, 95% CI: −0.92 to −0.07) and the risk of allogenic transfusion (OR = 0.45, 95% CI: 0.25 to 0.81) but showed no significant difference in the volume of drainage or total blood loss. Funnel plots showed no evidence of publication bias. This meta-analysis provides robust evidence supporting the effectiveness of Floseal in reducing hemoglobin decline and transfusion in TKA. Further well-designed RCTs with longer follow-up periods are warranted to assess long-term efficacy and safety.


  • Open Access

    Is the construct stability of the acetabular cup affected by the acetabular screw configuration in bone defect models?

    by Ho-Jin Nam, Young-Wook Lim, Woo-Lam Jo, Ji Hoon Bahk, Soon-Yong Kwon, Hyung Chul Park, Saad Mohammed AlShammari

    Background: In revision surgery with significant segmental acetabular defects, adequate implant selection and fixation methods are critical in determining successful bony ingrowth. Commercially available total hip prosthesis manufacturers generally offer additional multi-hole options of acetabular shells with identical designs for use in revision THAs where screw holes configurations vary from product to product. This study aims to compare the mechanical stability of the two types of acetabular screw constructs for the fixation of acetabular components: spread-out and pelvic brim-focused configurations. Methods: We prepared 40 synthetic bone models of the male pelvis. In half of the samples with acetabular defects, identical curvilinear bone defects were manually created using an oscillating electrical saw. On the right side, multi-hole-cups in which the direction of the screw holes are centered on the pelvic brim (brim-focused) and, on the left side, multi-hole-cups with the direction of the screw hole spread throughout the acetabulum (spread-out) were implanted into the pelvic synthetic bones. Coronal lever-out and axial torsion tests were performed with a testing machine, measuring load versus displacement. Results: The average torsional strengths were significantly higher in the spread-out group over the brim-focused group regardless of the presence of the segmental defect of the acetabulum (p < 0.001). But for the lever-out strength, the spread-out group exhibited significantly higher average strength over the brim-focused group for the intact acetabulum (p = 0.004), whereas the results were reversed in the brim-focused group when the defects were generated (p < 0.001). The presence of acetabular defects reduced the average torsional strengths of the two groups by 68.66% versus 70.86%. In comparison, the decrease in the average lever-out strength was less significant for the brim-focused group than the spread-out group (19.87% vs. 34.25%) (p < 0.001). Conclusion: Constructs of multi-hole acetabular cups with the spread-out screw holes configuration exhibited statistically better axial torsional strength and coronal lever-out strength. With the presence of posterior segmental bone defects, the spread-out constructs demonstrated significantly better tolerance to axial torsional strength. Still, they exhibited inverted results of higher lever-out strength in the pelvic brim-focused constructs.


  • Open Access

    Weight-Based Bisphosphonate Administration for Multiple Myeloma Patients and the Risks of Skeletal Complications

    by Ji Hoon Bahk, Woo-Lam Jo, Soon-Yong Kwon, Hyung Chul Park, Young Wook Lim

    High-dose bisphosphonate for multiple myeloma patients might elevate risks of skeletal complications earlier than general expectations. This study aims to find incidences of atypical femoral fracture (AFF) and medication-related osteonecrosis of the jaw (MRONJ), elucidate their risk factors, and suggest cut-off values for the safer dosing of high-dose bisphosphonate treatment. By using the clinical data warehouse of a single institute, retrospective cohort data of multiple myeloma-diagnosed patients with high-dose bisphosphonate (pamidronate or zoledronate) treatment from 2009 to 2019 was extracted. Among 644 patients, the incidence of prominent AFF requiring surgery was 0.93% (6/644) and MRONJ was diagnosed in 11.8% (76/644) of the study population. For both AFF and MRONJ, the total potency-weighted sum of total dose per body weight (OR = 1.010, p = 0.005) were significant on logistic regression. Cutoffs of the potency-weighted total dose (mg) per body weight (kg) for AFF and MRONJ were 77.00 and 57.70 mg/kg, respectively. After roughly one year of treatment with high-dose zoledronate (about four years for pamidronate), an earlier thorough re-evaluation of skeletal complications should be taken. Body weight adjustments for accumulative dose calculation in terms of permissible dosing should be taken into consideration.


  • Open Access

    Lateral pillar is the key in supporting pre-collapse osteonecrosis of the femoral head: a finite element model analysis of propensity-score matched cohorts

    by Ji Hoon Bahk, Woo-Lam Jo, Seung-Chan Kim, Soon-Yong Kwon, Young Wook Lim

    Background: This study was designed as a cohort study using propensity-score matching to age, gender, and body mass index (BMI) for finite element model (FEM) analysis from pre-collapse CT images of collapsed and non-collapsed hips. Through FEM analysis, a global graphical output around the hip joint can provide simple impression of stress distribution: concentration or dispersion. Methods: A total of 32 hips with ARCO stage 2 or 3 ONFH who were on follow up for over a one-year period were retrospectively reviewed. 16 hips with no interval progression of collapse were set as the study group, then 16 hips with progression of collapse which required arthroplasty were set as the control group using propensity-score matching. FEM was generated through Mechanical Finder for each patient, then 4500 N of load was applied to 1000 mm2 area at the top of iliac crest to analyze the models in terms of equivalents for yield stress. Results: Age, sex, and BMI had no significant differences between the two groups, while location (p = 0.015) was lateral, and size (p = 0.015) was significantly greater in the collapsed group. Non-collapsed hips mostly exhibited stress dispersion allocated to medial and lateral pillars, while collapsed hips exhibited stress concentration focused on the lateral pillar and the primary compression trabecula. (p = 0.001). Conclusion: Through FEM analysis, stress concentration to the lateral pillar and the primary compression trabeculae can be used to predict future collapse in ONFH with high probability. Results provide a simple and intuitive, yet valuable information to aid surgeons. Therefore, especially for young patients, holding out the lateral pillar through joint preserving procedures might be the key in preventing further collapse.


  • Open Access

    Improved Biological Responses of Titanium Coating Using Laser-Aided Direct Metal Fabrication on SUS316L Stainless Steel

    by Tae-In Kim, Se-Won Lee, Woo-Lam Jo, Yong-Sik Kim, Seung-Chan Kim, Soon-Yong Kwon, Young-Wook Lim

    Direct metal fabrication (DMF) coatings have the advantage of a more uniform porous structure and superior mechanical properties compared to coatings provided by other methods. We applied pure titanium metal powders to SUS316L stainless steel using laser-aided DMF coating technology with 3D printing. The purpose of this study was to determine the efficacy of this surface modification of stainless steel. The capacity of cells to adhere to DMF-coated SUS316L stainless steel was compared with machined SUS316L stainless steel in vitro and in vivo. Morphological in vitro response to human osteoblast cell lines was evaluated using scanning electron microscopy. Separate specimens were inserted into the medulla of distal femurs of rabbits for in vivo study. The distal femurs were harvested after 3 months, and were then subjected to push-out test and histomorphometrical analyses. The DMF group exhibited a distinct surface chemical composition, showing higher peaks of titanium compared to the machined stainless steel. The surface of the DMF group had a more distinct porous structure, which showed more extensive coverage with lamellipodia from osteoblasts than the machined surface. In the in vivo test, the DMF group showed better results than the machined group in the push-out test (3.39 vs. 1.35 MPa, respectively, p = 0.001). In the histomorphometric analyses, the mean bone-to-implant contact percentage of the DMF group was about 1.5 times greater than that of the machined group (65.4 ± 7.1% vs. 41.9 ± 5.6%, respectively; p < 0.001). The porous titanium coating on SUS316L stainless steel produced using DMF with 3D printing showed better surface characteristics and biomechanical properties than the machined SUS316L.