TKTimothy Kerry

Timothy Kerry

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Timothy Kerry has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Preparation of uranium(III) in a molten chloride salt: a redox mechanistic study

    by Hugues Lambert, Timothy Kerry, Clint A. Sharrad

    The most advanced methodology for the pyroprocessing of spent nuclear fuel is the electrorefining of uranium metal in LiCl–KCl eutectic, in which uranium is solubilized as U(III). The production of U(III) in LiCl–KCl eutectic by the chlorination of uranium metal using BiCl3 has been performed for research purposes. In this work, this reaction was studied in-situ by visual observation, electronic absorption spectroscopy and electrochemistry at 450 °C. The most likely mechanism has been determined to involve the initial direct oxidation of uranium metal by Bi(III) to U(IV). The dissolved U(IV) then reacts with unreacted uranium metal to form U(III).


  • Depth profile analysis of rare earth elements in corroded steels by pulsed glow discharge – time of flight mass spectrometry

    by Rocío Muñiz, Lara Lobo, Timothy Kerry, Clint A. Sharrad, Rosario Pereiro

    Depth profiling of 304L stainless steel surfaces exposed to rare earth nitrate solutions over varying time lengths has been undertaken using the recently commercialized “PP-TOFMS Plasma Profiling Spectrometer” by Horiba. This combines a pulsed glow discharge source with a time-of-flight mass spectrometer (TOFMS) which allows elemental depth profiling with nanometric resolution of almost all elements of the periodic table. In this work special attention is paid first to the optimization of the new PP-TOFMS for depth profile analysis of low concentrations of rare earth elements (REE) in the samples. Sensitivity given in [(cps X × sputtering rate in μg s−1)/(μgX g−1)], being the concentration of the element X (μgX g−1) corrected by the abundance of the measured isotope, was in the order of 20 for all REEs under investigation. Moreover, a quantification strategy for these samples resembling the relative sensitive factors concept has been developed. Validation was done using a homogeneous reference material containing certified concentration values for La (6 ± 1 μg g−1), Ce (14 ± 1 μg g−1) and Nd (6 ± 1 μg g−1). Concentrations of 4 ± 1 μg g−1, 13 ± 1 μg g−1 and 5 ± 1 μg g−1 were calculated for La, Ce and Nd respectively with the proposed strategy. Quantitative depth profiles of the investigated samples have shown that the contaminants did not penetrate the substrate deeper than 80 nm even after a month of exposure to 12 M HNO3.