Fernanda M. Ferraz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Fernanda M. Ferraz has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
J. Povinelli
Departamento de Hidráulica e Saneamento, Escola de Engenharia de São Carlos, Universidade de São Paulo - Av. Trabalhador São Carlense, 400, CEP 13566-590, São Carlos, São Paulo, Brazil
3 shared publicationsE.M. Vieira
Instituto de Química de São Carlos, Universidade de São Paulo - Av.Trabalhador São Carlense, 400, CEP 13566-590, São Carlos, São Paulo, Brazil
2 shared publicationsA.T. Bruni
Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Brazil
1 shared publicationAline T. Bruni
Departamento de Física, Instituto de Biociências Letras e Ciências Exatas de São José do Rio Preto, Universidade Estadual Paulista,São José do Rio Preto, SP, Brasil
1 shared publicationE. M. Vieira
Instituto de Química de São Carlos, Universidade de São Paulo, Av. Trabalhador São Carlense, 400, CEP 13566-590 São Carlos, São Paulo, Brasil
1 shared publicationE. Pozzi
Departamento de Hidráulica e Saneamento, Escola de Engenharia de São Carlos, Universidade de São Paulo, Av.Trabalhador Sao Carlense, 400, CEP 13566-590 Sao Carlos, São Paulo, Brazil
1 shared publication
Latest Publications
- 1 September 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 143 (9)
Landfill Leachate Treatment Using Aerobic Granular Sludge
This research investigated the treatment of landfill leachate using aerobic granular sludge (AGS). The AGS was cultivated from a lab-scale sequencing batch reactor (SBR). Leachate was gradually fed into the aerobic granular sludge SBR (GSBR) by mixing it with primary effluent at ratios varying from 10 to 90%. Regardless of the different mixing ratios or high free-ammonia (FA) and free-nitrous-acid (FNA) concentrations in the influent, the GSBR demonstrated high total ammoniacal nitrogen (TAN) removal efficiency, which ranged from 95 to 100%. The best results were obtained when the total nitrogen (TN) load was ( of TAN in the influent), where the FA concentration was the lowest ( ). For a nitrogen load up to (i.e., TN and FA ), chemical oxygen demand (COD), TN, and phosphorus removal of GSBR were around 64, 42, and 84%, respectively. With the further increase in the nitrogen load, the TN, COD, and phosphorus removal rate of GSBR decreased significantly; however, the TAN removal efficiency remained constant at 90–100%. This study showed that the AGS is able to treat leachate with high concentrations of TAN ( ), and simultaneous nitrification and denitrification play a significant role in nitrogen removal. From these promising results, the use of AGS for leachate treatment should be encouraged.- 1 September 2017
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 143 (9)
Landfill Leachate Treatment Using Aerobic Granular Sludge
This research investigated the treatment of landfill leachate using aerobic granular sludge (AGS). The AGS was cultivated from a lab-scale sequencing batch reactor (SBR). Leachate was gradually fed into the aerobic granular sludge SBR (GSBR) by mixing it with primary effluent at ratios varying from 10 to 90%. Regardless of the different mixing ratios or high free-ammonia (FA) and free-nitrous-acid (FNA) concentrations in the influent, the GSBR demonstrated high total ammoniacal nitrogen (TAN) removal efficiency, which ranged from 95 to 100%. The best results were obtained when the total nitrogen (TN) load was ( of TAN in the influent), where the FA concentration was the lowest ( ). For a nitrogen load up to (i.e., TN and FA ), chemical oxygen demand (COD), TN, and phosphorus removal of GSBR were around 64, 42, and 84%, respectively. With the further increase in the nitrogen load, the TN, COD, and phosphorus removal rate of GSBR decreased significantly; however, the TAN removal efficiency remained constant at 90–100%. This study showed that the AGS is able to treat leachate with high concentrations of TAN ( ), and simultaneous nitrification and denitrification play a significant role in nitrogen removal. From these promising results, the use of AGS for leachate treatment should be encouraged.- 1 January 2016
- Published by Elsevier in Journal of Environmental Management
- Vol. 166, 414-419
Leachate/domestic wastewater aerobic co-treatment: A pilot-scale study using multivariate analysis
- 1 January 2016
- Published by Elsevier in Journal of Environmental Management
- Vol. 166, 414-419
Leachate/domestic wastewater aerobic co-treatment: A pilot-scale study using multivariate analysis
- 30 October 2014
- Published by IWA Publishing in Water Science & Technology
- Vol. 70 (12) , 1941-1947
Aerobic co-treatment of landfill leachate and domestic wastewater – are slowly biodegradable organics removed or simply diluted?
This study investigated the co-treatment of landfill leachate/domestic wastewater in bench-scale activated sludge (AS) reactors to determine whether the slowly biodegradable organic matter (SBOM) was removed rather than diluted. The AS reactors were loaded with mixtures of raw leachate and leachate that was pretreated by air stripping. The tested volumetric ratios were 0%, 0.2%, 2% and 5%. For all of the tested conditions, the reactors performed better when pretreated leachate was used rather than raw leachate, and the best volumetric ratio was 2%. The following removals were obtained: 97% for the biochemical oxygen demand (BOD5,20), 79% for total suspended solids, 77% for dissolved organic carbon and 84% for soluble chemical oxygen demand. Most of the pretreated leachate SBOM (65%) was removed rather than diluted or adsorbed into the sludge, as confirmed by Fourier transform infrared (FTIR) spectroscopy analyses.
- 30 October 2014
- Published by IWA Publishing in Water Science & Technology
- Vol. 70 (12) , 1941-1947
Aerobic co-treatment of landfill leachate and domestic wastewater – are slowly biodegradable organics removed or simply diluted?
This study investigated the co-treatment of landfill leachate/domestic wastewater in bench-scale activated sludge (AS) reactors to determine whether the slowly biodegradable organic matter (SBOM) was removed rather than diluted. The AS reactors were loaded with mixtures of raw leachate and leachate that was pretreated by air stripping. The tested volumetric ratios were 0%, 0.2%, 2% and 5%. For all of the tested conditions, the reactors performed better when pretreated leachate was used rather than raw leachate, and the best volumetric ratio was 2%. The following removals were obtained: 97% for the biochemical oxygen demand (BOD5,20), 79% for total suspended solids, 77% for dissolved organic carbon and 84% for soluble chemical oxygen demand. Most of the pretreated leachate SBOM (65%) was removed rather than diluted or adsorbed into the sludge, as confirmed by Fourier transform infrared (FTIR) spectroscopy analyses.
- 1 August 2014
- Published by Elsevier in Journal of Environmental Management
- Vol. 141, 9-15
Co-treatment of landfill leachate and domestic wastewater using a submerged aerobic biofilter
- 1 August 2014
- Published by Elsevier in Journal of Environmental Management
- Vol. 141, 9-15
Co-treatment of landfill leachate and domestic wastewater using a submerged aerobic biofilter
- 11 February 2013
- Published by Taylor & Francis in Environmental Technology
- Vol. 34 (15) , 2317-2326
Ammonia removal from landfill leachate by air stripping and absorption
An old landfill leachate was pre-treated in a pilot-scale aerated packed tower operated in batch mode for total ammoniacal nitrogen (TAN) removal. The stripped ammonia was recovered with a 0.4 mol L−1 H2SO4 solution, deionized water and tap water. Ca(OH)2 (95% purity) or commercial hydrated lime was added to the raw leachate to adjust its pH to 11, causing removal of colour (82%) and heavy metals (70–90% for Zn, Fe and Mn). The 0.4 mol L−1 H2SO4 solution was able to neutralize 80% of the stripped ammonia removed from 12 L of leachate. The effectiveness of the neutralization of ammonia with deionized water was 75%. Treating 100 L of leachate, the air stripping tower removed 88% of TAN after 72 h of aeration, and 87% of the stripped ammonia was recovered in two 31 L pilot-scale absorption units filled with 20 L of tap water.
- 11 February 2013
- Published by Taylor & Francis in Environmental Technology
- Vol. 34 (15) , 2317-2326
Ammonia removal from landfill leachate by air stripping and absorption
An old landfill leachate was pre-treated in a pilot-scale aerated packed tower operated in batch mode for total ammoniacal nitrogen (TAN) removal. The stripped ammonia was recovered with a 0.4 mol L−1 H2SO4 solution, deionized water and tap water. Ca(OH)2 (95% purity) or commercial hydrated lime was added to the raw leachate to adjust its pH to 11, causing removal of colour (82%) and heavy metals (70–90% for Zn, Fe and Mn). The 0.4 mol L−1 H2SO4 solution was able to neutralize 80% of the stripped ammonia removed from 12 L of leachate. The effectiveness of the neutralization of ammonia with deionized water was 75%. Treating 100 L of leachate, the air stripping tower removed 88% of TAN after 72 h of aeration, and 87% of the stripped ammonia was recovered in two 31 L pilot-scale absorption units filled with 20 L of tap water.
- Open Access
- 1 March 2009
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Microbiology
- Vol. 40 (1) , 48-53
Performance of an Anaerobic Baffled Reactor (ABR) in treatment of cassava wastewater
The performance of an anaerobic baffled reactor (ABR) was evaluated in the treatment of cassava wastewater, a pollutant residue. An ABR divided in four equal volume compartments (total volume 4L) and operated at 35ºC was used in cassava wastewater treatment. Feed tank chemical oxygen demand (COD) was varied from 2000 to 7000 mg L(-1) and it was evaluated the most appropriated hydraulic retention time (HRT) for the best performance on COD removal. The ABR was evaluated by analysis of COD (colorimetric method), pH, turbidity, total and volatile solids, alkalinity and acidity. Principal component analysis (PCA) was carried to better understand data obtained. The system showed buffering ability as acidity decreased along compartments while alkalinity and pH values were increased. There was particulate material retention and COD removal varied from 83 to 92% for HRT of 3.5 days.
- 1 March 2009
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Microbiology
- Vol. 40 (1) , 48-53
Open AccessPerformance of an Anaerobic Baffled Reactor (ABR) in treatment of cassava wastewater
The performance of an anaerobic baffled reactor (ABR) was evaluated in the treatment of cassava wastewater, a pollutant residue. An ABR divided in four equal volume compartments (total volume 4L) and operated at 35ºC was used in cassava wastewater treatment. Feed tank chemical oxygen demand (COD) was varied from 2000 to 7000 mg L(-1) and it was evaluated the most appropriated hydraulic retention time (HRT) for the best performance on COD removal. The ABR was evaluated by analysis of COD (colorimetric method), pH, turbidity, total and volatile solids, alkalinity and acidity. Principal component analysis (PCA) was carried to better understand data obtained. The system showed buffering ability as acidity decreased along compartments while alkalinity and pH values were increased. There was particulate material retention and COD removal varied from 83 to 92% for HRT of 3.5 days.