Theodor Willem von Backström
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Theodor Willem von Backström has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Sybrand Johannes van der Spuy
Stellenbosch University
12 shared publications Anthony J. Gannon
Department of Mechanical Engineering, University of Stellenbosch, Private Bag X1, Matieland 7602, South Africa
8 shared publicationsThomas M. Harms
7 shared publicationsD.G. Kröger
6 shared publicationsK.G. Allen
4 shared publicationsT. M. Harms
University of Stellenbosch, Stellenbosch, Western Cape, South Africa
4 shared publications
Latest Publications
- Open Access
- 16 July 2021
- Published by ASME International
Blade Surface Pressure Measurements on a Low Pressure Rise Axial Flow Fan
Fan performance characteristic tests on axial flow fans provide information on the global flow field, based on stable inlet flow field distribution. More information is often required on the local flow distribution existing in the vicinity of the fan blades. A 1.543 m diameter scale model of an axial flow fan, termed the M-Fan is tested in an ISO 5801, type A, test facility. The
- 16 July 2021
- Published by ASME International
Open AccessBlade Surface Pressure Measurements on a Low Pressure Rise Axial Flow Fan
Fan performance characteristic tests on axial flow fans provide information on the global flow field, based on stable inlet flow field distribution. More information is often required on the local flow distribution existing in the vicinity of the fan blades. A 1.543 m diameter scale model of an axial flow fan, termed the M-Fan is tested in an ISO 5801, type A, test facility. The
- Open Access
- 1 December 2019
- Published by Stellenbosch University in R&D Journal
- Vol. 35, 55-63
Slip Factor Prediction for Impellers with Straight, Back-swept Blades
Slip factor accounts for the deviation of the flow angle from the trailing edge blade angle at the exit of radial impellers. Accurate values are required to predict impeller torque and energy input. The slip factor prediction method for back-swept radial bladed impellers is based on the so-called single relative eddy (SRE) method, which is an approximation of the classical, two-dimensional analytical solution to the inviscid flow problem. The relatively accurate prediction of the slip factors of 19 impellers found in four data sets published since its formulation, shows the reliability of the SRE method. The characteristics of straight-bladed impeller layouts are explored and incorporated into the SRE method. It turns out that the SRE method as developed for logarithmic spiral blades predicts the inviscid flow slip factor of 42 different straight bladed impeller geometries accurately, when a correction for the critical radius ratio at low blade numbers is introduced. Predicted slip factor values are also compared to new experimental data for five different impellers with straight, back-swept blades, over a range of three blade angles and three blade numbers. Agreement is excellent near the flow coefficient corresponding to the volute design angle.
- 1 December 2019
- Published by Stellenbosch University in R&D Journal
- Vol. 35, 55-63
Open AccessSlip Factor Prediction for Impellers with Straight, Back-swept Blades
Slip factor accounts for the deviation of the flow angle from the trailing edge blade angle at the exit of radial impellers. Accurate values are required to predict impeller torque and energy input. The slip factor prediction method for back-swept radial bladed impellers is based on the so-called single relative eddy (SRE) method, which is an approximation of the classical, two-dimensional analytical solution to the inviscid flow problem. The relatively accurate prediction of the slip factors of 19 impellers found in four data sets published since its formulation, shows the reliability of the SRE method. The characteristics of straight-bladed impeller layouts are explored and incorporated into the SRE method. It turns out that the SRE method as developed for logarithmic spiral blades predicts the inviscid flow slip factor of 42 different straight bladed impeller geometries accurately, when a correction for the critical radius ratio at low blade numbers is introduced. Predicted slip factor values are also compared to new experimental data for five different impellers with straight, back-swept blades, over a range of three blade angles and three blade numbers. Agreement is excellent near the flow coefficient corresponding to the volute design angle.
- 7 December 2018
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 141 (5)
Performance Testing of an Axial Flow Fan Designed for Air-Cooled Heat Exchanger Applications
An axial flow fan developed in the previous study is tested in order to characterize its performance. The M-fan, a 7.3152 m diameter rotor only axial flow fan was designed to perform well under the challenging operating conditions encountered in air-cooled heat exchangers. Preliminary computational fluid dynamics (CFD) results obtained using an actuator disk model (ADM) as well as a periodic three dimensional model indicate that the fan meets the specified performance targets, with an expected total-to-static efficiency of 59.4% and a total-to-static pressure rise of 114.7 Pa at the operating point. Experimental tests are performed on the M-fan in order to determine its performance across a full range of flow rates. A range of fan configurations are tested in order to ascertain the effect of tip clearance, blade angle, and hub configuration on fan performance. Due to the lack of a suitable facility for testing a large diameter fan, a scaled 1.542 m diameter model is tested on the ISO 5801 type A fan test facility at Stellenbosch University. A Reynolds-averaged Navier–Stokes CFD model representing the M-fan in the test facility is also developed in order to provide additional insight into the flow field in the vicinity of the fan blades. The results of the CFD model will be validated using the experimental data obtained. Both the CFD results and the experimental data obtained are compared to the initial CFD results for the full scale fan, as obtained in the previous study, by means of fan scaling laws. Experimental data indicate that the M-fan does not meet the pressure requirement set out in the initial study at the design blade setting angle of 34 deg. Under these conditions, the M-fan attains a total-to-static pressure rise of 102.5 Pa and a total-to-static efficiency of 56.4%, running with a tip gap of 2 mm. Increasing the blade angle is shown to be a potential remedy, improving the total-to-static pressure rise and efficiency obtained at the operating point. The M-fan is also shown to be highly sensitive to increasing tip gap, with larger tip gaps substantially reducing fan performance. The losses due to tip gap are also shown to be overestimated by the CFD simulations. Both experimental and numerically obtained results indicate lower fan total-to-static efficiencies than obtained in the initial CFD study. Results indicate that the M-fan is suited to its intended application, however, it should be operated with a smaller tip gap than initially recommended and a larger blade setting angle. Hub configuration is also shown to have an influence on fan performance, potentially improving performance at low flow rates.
- 7 December 2018
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 141 (5)
Performance Testing of an Axial Flow Fan Designed for Air-Cooled Heat Exchanger Applications
An axial flow fan developed in the previous study is tested in order to characterize its performance. The M-fan, a 7.3152 m diameter rotor only axial flow fan was designed to perform well under the challenging operating conditions encountered in air-cooled heat exchangers. Preliminary computational fluid dynamics (CFD) results obtained using an actuator disk model (ADM) as well as a periodic three dimensional model indicate that the fan meets the specified performance targets, with an expected total-to-static efficiency of 59.4% and a total-to-static pressure rise of 114.7 Pa at the operating point. Experimental tests are performed on the M-fan in order to determine its performance across a full range of flow rates. A range of fan configurations are tested in order to ascertain the effect of tip clearance, blade angle, and hub configuration on fan performance. Due to the lack of a suitable facility for testing a large diameter fan, a scaled 1.542 m diameter model is tested on the ISO 5801 type A fan test facility at Stellenbosch University. A Reynolds-averaged Navier–Stokes CFD model representing the M-fan in the test facility is also developed in order to provide additional insight into the flow field in the vicinity of the fan blades. The results of the CFD model will be validated using the experimental data obtained. Both the CFD results and the experimental data obtained are compared to the initial CFD results for the full scale fan, as obtained in the previous study, by means of fan scaling laws. Experimental data indicate that the M-fan does not meet the pressure requirement set out in the initial study at the design blade setting angle of 34 deg. Under these conditions, the M-fan attains a total-to-static pressure rise of 102.5 Pa and a total-to-static efficiency of 56.4%, running with a tip gap of 2 mm. Increasing the blade angle is shown to be a potential remedy, improving the total-to-static pressure rise and efficiency obtained at the operating point. The M-fan is also shown to be highly sensitive to increasing tip gap, with larger tip gaps substantially reducing fan performance. The losses due to tip gap are also shown to be overestimated by the CFD simulations. Both experimental and numerically obtained results indicate lower fan total-to-static efficiencies than obtained in the initial CFD study. Results indicate that the M-fan is suited to its intended application, however, it should be operated with a smaller tip gap than initially recommended and a larger blade setting angle. Hub configuration is also shown to have an influence on fan performance, potentially improving performance at low flow rates.
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
Performance prediction of the SCRAP pressurized air receiver
- 1 January 2018
- Published by AIP Publishing in AIP Conference Proceedings
Performance prediction of the SCRAP pressurized air receiver
- 4 March 2017
- Published by Walter de Gruyter GmbH in International Journal of Turbo & Jet-Engines
- Vol. 36 (4) , 347-357
Design of a Compact Crossover Diffuser for Micro Gas Turbines Using a Mean-Line Code
The design and validation of a Compact Crossover Diffuser (CCD) to replace the size-limited radial diffuser and axial de-swirl cascade of an existing Micro Gas Turbine (MGT) is discussed. A CCD strives to combine the performance of a channel diffuser with the operating range and efficiency of a vaneless diffuser. The development of a one-dimensional Mean-Line Code (MLC) is presented, which aids the designer in preliminary design and performance evaluation of the CCD. Design graphs indicating the performance effects of changing the primary design variables are developed and shown. The MLC is numerically validated using Computational Fluid Dynamics (CFD). Good agreement is seen between the MLC and CFD results, predicting the design point PRss(2-4) to within 1.4 %. A CFD optimized CCD was manufactured and tested. Agreement between the CFD and experimental results for PRts(0-4) is within 7.58 % at 106 kRPM. A numerically predicted increase in PRts(0-4) from 3.31, to 3.53, to 3.83 is seen for the vaneless-, MLC optimized-, and CFD optimized-design respectively. An experimental increase of 82.3 % in engine thrust and 80.0 % in total-to-static pressure recovery across the compressor stage was measured when retrofitting the BMT120KS with a new impeller and CCD.
- 4 March 2017
- Published by Walter de Gruyter GmbH in International Journal of Turbo & Jet-Engines
- Vol. 36 (4) , 347-357
Design of a Compact Crossover Diffuser for Micro Gas Turbines Using a Mean-Line Code
The design and validation of a Compact Crossover Diffuser (CCD) to replace the size-limited radial diffuser and axial de-swirl cascade of an existing Micro Gas Turbine (MGT) is discussed. A CCD strives to combine the performance of a channel diffuser with the operating range and efficiency of a vaneless diffuser. The development of a one-dimensional Mean-Line Code (MLC) is presented, which aids the designer in preliminary design and performance evaluation of the CCD. Design graphs indicating the performance effects of changing the primary design variables are developed and shown. The MLC is numerically validated using Computational Fluid Dynamics (CFD). Good agreement is seen between the MLC and CFD results, predicting the design point PRss(2-4) to within 1.4 %. A CFD optimized CCD was manufactured and tested. Agreement between the CFD and experimental results for PRts(0-4) is within 7.58 % at 106 kRPM. A numerically predicted increase in PRts(0-4) from 3.31, to 3.53, to 3.83 is seen for the vaneless-, MLC optimized-, and CFD optimized-design respectively. An experimental increase of 82.3 % in engine thrust and 80.0 % in total-to-static pressure recovery across the compressor stage was measured when retrofitting the BMT120KS with a new impeller and CCD.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1850, 080015
Developing a cost effective rock bed thermal energy storage system: Design and modelling
Thermal energy storage is an integral part of the drive for low cost of concentrated solar power (CSP). Storage of thermal energy enables CSP plants to provide base load power. Alternative, cheaper concepts for storing thermal energy have been conceptually proposed in previous studies. Using rocks as a storage medium and air as a heat transfer fluid, the proposed concept offers the potential of lower cost storage because of the abundance and affordability of rocks. A packed rock bed thermal energy storage (TES) concept is investigated and a design for an experimental rig is done. This paper describes the design and modelling of an experimental test facility for a cost effective packed rock bed thermal energy storage system. Cost effective, simplified designs for the different subsystems of an experimental setup are developed based on the availability of materials and equipment. Modelling of this design to predict the thermal performance of the TES system is covered in this study. If the concept under consideration proves to be successful, a design that is scalable and commercially viable can be proposed for further development of an industrial thermal energy storage system.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1850, 080015
Developing a cost effective rock bed thermal energy storage system: Design and modelling
Thermal energy storage is an integral part of the drive for low cost of concentrated solar power (CSP). Storage of thermal energy enables CSP plants to provide base load power. Alternative, cheaper concepts for storing thermal energy have been conceptually proposed in previous studies. Using rocks as a storage medium and air as a heat transfer fluid, the proposed concept offers the potential of lower cost storage because of the abundance and affordability of rocks. A packed rock bed thermal energy storage (TES) concept is investigated and a design for an experimental rig is done. This paper describes the design and modelling of an experimental test facility for a cost effective packed rock bed thermal energy storage system. Cost effective, simplified designs for the different subsystems of an experimental setup are developed based on the availability of materials and equipment. Modelling of this design to predict the thermal performance of the TES system is covered in this study. If the concept under consideration proves to be successful, a design that is scalable and commercially viable can be proposed for further development of an industrial thermal energy storage system.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
Introduction to heat transfer test setup for the SCRAP receiver
The Spiky Central Receiver Air Pre-heater (SCRAP) receiver is a novel external tubular metallic central receiver concept. The SCRAP receiver is designed to increase an air-receivers solar-thermal performance. This is aimed to be achieved by enhancing heat transfer to the pressurized air-stream within the absorber assemblies (spikes) by utilizing an internally finned tube geometry. The fin shape is defined to create rectangular ducts as passages for the air flow, therewith a high heat transfer coefficient. The spikes are arranged in such a way that they trap incoming concentrated radiation (reduce reflection losses) and minimize thermal radiation losses from the receiver to ambient. In previous work, the modeling of a SCRAP receiver was discussed on. This included the modeling of the internal air flow and heat transfer within a spike, analysis of the optical characteristics of a SCRAP receiver and the impingement heat transfer capabilities in the spike tip (exposed to the highest flux). Further, analysis of the thermal interaction of spikes with one another and with ambient (convective and radiative heat loss) permitted drawing of first conclusions of the receiver performance potential. To validate the models predicting the pressurized air flow and heat transfer within a spike, an experimental test setup was designed, constructed and built at the heat transfer laboratories at Stellenbosch University. This work introduces the design of the test setup and will discuss preliminary results obtained during its commissioning. From first analysis the predictions made for the pressure drop within the internally finned section appear adequate. The heat transfer behavior will require further detailed analysis to develop sufficient confidence to allow for conclusions. Initial results, however, show good general agreement between measured and simulated data.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
Introduction to heat transfer test setup for the SCRAP receiver
The Spiky Central Receiver Air Pre-heater (SCRAP) receiver is a novel external tubular metallic central receiver concept. The SCRAP receiver is designed to increase an air-receivers solar-thermal performance. This is aimed to be achieved by enhancing heat transfer to the pressurized air-stream within the absorber assemblies (spikes) by utilizing an internally finned tube geometry. The fin shape is defined to create rectangular ducts as passages for the air flow, therewith a high heat transfer coefficient. The spikes are arranged in such a way that they trap incoming concentrated radiation (reduce reflection losses) and minimize thermal radiation losses from the receiver to ambient. In previous work, the modeling of a SCRAP receiver was discussed on. This included the modeling of the internal air flow and heat transfer within a spike, analysis of the optical characteristics of a SCRAP receiver and the impingement heat transfer capabilities in the spike tip (exposed to the highest flux). Further, analysis of the thermal interaction of spikes with one another and with ambient (convective and radiative heat loss) permitted drawing of first conclusions of the receiver performance potential. To validate the models predicting the pressurized air flow and heat transfer within a spike, an experimental test setup was designed, constructed and built at the heat transfer laboratories at Stellenbosch University. This work introduces the design of the test setup and will discuss preliminary results obtained during its commissioning. From first analysis the predictions made for the pressure drop within the internally finned section appear adequate. The heat transfer behavior will require further detailed analysis to develop sufficient confidence to allow for conclusions. Initial results, however, show good general agreement between measured and simulated data.
- 2 September 2016
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 138 (6) , 061004
Cost Optimum Parameters for Rock Bed Thermal Storage at 550–600 °C: A Parametric Study
A major advantage of concentrating solar power (CSP) plants is their ability to store thermal energy at a cost far lower than that of current battery technologies. A recent techno-economic study found that packed rock bed thermal storage systems can be constructed with capital costs of less than 10 United States dollar (USD)/kWht, significantly cheaper than the two-tank molten salt thermal storage currently used in CSP plants (about 22–30 USD/kWht). However, little work has been published on determining optimum rock bed design parameters in the context of a CSP plant. The parametric study in this paper is intended to provide an overview of the bed flow lengths, particle sizes, mass fluxes, and Biot numbers which are expected to minimize the levelized cost of electricity (LCOE) for a central receiver CSP plant with a nominal storage capacity of 12 h. The findings show that rock diameters of 20–25 mm will usually give LCOE values at or very close to the minimum LCOE for the combined rock bed and CSP plant. Biot numbers between 0.1 and 0.2 are shown to have little influence on the position of the optimum (with respect to particle diameter) for all practical purposes. Optimum bed lengths are dependent on the Biot number and range between 3 and 10 m for a particle diameter of 20 mm.
- 2 September 2016
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 138 (6) , 061004
Cost Optimum Parameters for Rock Bed Thermal Storage at 550–600 °C: A Parametric Study
A major advantage of concentrating solar power (CSP) plants is their ability to store thermal energy at a cost far lower than that of current battery technologies. A recent techno-economic study found that packed rock bed thermal storage systems can be constructed with capital costs of less than 10 United States dollar (USD)/kWht, significantly cheaper than the two-tank molten salt thermal storage currently used in CSP plants (about 22–30 USD/kWht). However, little work has been published on determining optimum rock bed design parameters in the context of a CSP plant. The parametric study in this paper is intended to provide an overview of the bed flow lengths, particle sizes, mass fluxes, and Biot numbers which are expected to minimize the levelized cost of electricity (LCOE) for a central receiver CSP plant with a nominal storage capacity of 12 h. The findings show that rock diameters of 20–25 mm will usually give LCOE values at or very close to the minimum LCOE for the combined rock bed and CSP plant. Biot numbers between 0.1 and 0.2 are shown to have little influence on the position of the optimum (with respect to particle diameter) for all practical purposes. Optimum bed lengths are dependent on the Biot number and range between 3 and 10 m for a particle diameter of 20 mm.
- Open Access
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1734 (1) , 030024
Performance outlook of the SCRAP receiver
A combined cycle (CC) concentrating solar power (CSP) plant provides significant potential to achieve an efficiency increase and an electricity cost reduction compared to current single-cycle plants. A CC CSP system requires a receiver technology capable of effectively transferring heat from concentrated solar irradiation to a pressurized air stream of a gas turbine. The small number of pressurized air receivers demonstrated to date have practical limitations, when operating at high temperatures and pressures. As yet, a robust, scalable and efficient system has to be developed and commercialized. A novel receiver system, the Spiky Central Receiver Air Pre-heater (SCRAP) concept has been proposed to comply with these requirements. The SCRAP system is conceived as a solution for an efficient and robust pressurized air receiver that could be implemented in CC CSP concepts or standalone solar Brayton cycles without a bottoming Rankine cycle. The presented work expands on previous publications on the thermal modeling of the receiver system. Based on the analysis of a single heat transfer element (spike), predictions for its thermal performance can be made. To this end the existing thermal model was improved by heat transfer characteristics for the jet impingement region of the spike tip as well as heat transfer models simulating the interaction with ambient. While the jet impingement cooling effect was simulated employing a commercial CFD code, the ambient heat transfer model was based on simplifying assumptions in order to employ empirical and analytical equations. The thermal efficiency of a spike under design conditions (flux 1.0 MW/m2, air outlet temperature just below 800 °C) was calculated at approximately 80 %, where convective heat losses account for 16.2 % of the absorbed radiation and radiative heat losses for a lower 2.9 %. This effect is due to peak surface temperatures occurring at the root of the spikes. It can thus be concluded that the geometric receiver layout assists to limit radiative heat losses.
- 1 January 2016
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1734 (1) , 030024
Open AccessPerformance outlook of the SCRAP receiver
A combined cycle (CC) concentrating solar power (CSP) plant provides significant potential to achieve an efficiency increase and an electricity cost reduction compared to current single-cycle plants. A CC CSP system requires a receiver technology capable of effectively transferring heat from concentrated solar irradiation to a pressurized air stream of a gas turbine. The small number of pressurized air receivers demonstrated to date have practical limitations, when operating at high temperatures and pressures. As yet, a robust, scalable and efficient system has to be developed and commercialized. A novel receiver system, the Spiky Central Receiver Air Pre-heater (SCRAP) concept has been proposed to comply with these requirements. The SCRAP system is conceived as a solution for an efficient and robust pressurized air receiver that could be implemented in CC CSP concepts or standalone solar Brayton cycles without a bottoming Rankine cycle. The presented work expands on previous publications on the thermal modeling of the receiver system. Based on the analysis of a single heat transfer element (spike), predictions for its thermal performance can be made. To this end the existing thermal model was improved by heat transfer characteristics for the jet impingement region of the spike tip as well as heat transfer models simulating the interaction with ambient. While the jet impingement cooling effect was simulated employing a commercial CFD code, the ambient heat transfer model was based on simplifying assumptions in order to employ empirical and analytical equations. The thermal efficiency of a spike under design conditions (flux 1.0 MW/m2, air outlet temperature just below 800 °C) was calculated at approximately 80 %, where convective heat losses account for 16.2 % of the absorbed radiation and radiative heat losses for a lower 2.9 %. This effect is due to peak surface temperatures occurring at the root of the spikes. It can thus be concluded that the geometric receiver layout assists to limit radiative heat losses.
- 1 January 2016
- Published by AIP Publishing
- Vol. 1734 (1) , 160008
The effects of solarization on the performance of a gas turbine
Various hybrid solar gas turbine configurations exist. The Stellenbosch University Solar Power Thermodynamic (SUNSPOT) cycle consists of a heliostat field, solar receiver, primary Brayton gas turbine cycle, thermal storage and secondary Rankine steam cycle. This study investigates the effect of the solarization of a gas turbine on its performance and details the integration of a gas turbine into a solar power plant. A Rover 1S60 gas turbine was modelled in Flownex, a thermal-fluid system simulation and design code, and validated against a one-dimensional thermodynamic model at design input conditions. The performance map of a newly designed centrifugal compressor was created and implemented in Flownex. The effect of the improved compressor on the performance of the gas turbine was evident. The gas turbine cycle was expanded to incorporate different components of a CSP plant, such as a solar receiver and heliostat field. The solarized gas turbine model simulates the gas turbine performance when subjected to a typical variation in solar resource. Site conditions at the Helio100 solar field were investigated and the possibility of integrating a gas turbine within this system evaluated. Heat addition due to solar irradiation resulted in a decreased fuel consumption rate. The influence of the additional pressure drop over the solar receiver was evident as it leads to decreased net power output. The new compressor increased the overall performance of the gas turbine and compensated for pressure losses incurred by the addition of solar components. The simulated integration of the solarized gas turbine at Helio100 showed potential, although the solar irradiation is too little to run the gas turbine on solar heat alone. The simulation evaluates the feasibility of solarizing a gas turbine and predicts plant performance for such a turbine cycle.
- 1 January 2016
- Published by AIP Publishing
- Vol. 1734 (1) , 160008
The effects of solarization on the performance of a gas turbine
Various hybrid solar gas turbine configurations exist. The Stellenbosch University Solar Power Thermodynamic (SUNSPOT) cycle consists of a heliostat field, solar receiver, primary Brayton gas turbine cycle, thermal storage and secondary Rankine steam cycle. This study investigates the effect of the solarization of a gas turbine on its performance and details the integration of a gas turbine into a solar power plant. A Rover 1S60 gas turbine was modelled in Flownex, a thermal-fluid system simulation and design code, and validated against a one-dimensional thermodynamic model at design input conditions. The performance map of a newly designed centrifugal compressor was created and implemented in Flownex. The effect of the improved compressor on the performance of the gas turbine was evident. The gas turbine cycle was expanded to incorporate different components of a CSP plant, such as a solar receiver and heliostat field. The solarized gas turbine model simulates the gas turbine performance when subjected to a typical variation in solar resource. Site conditions at the Helio100 solar field were investigated and the possibility of integrating a gas turbine within this system evaluated. Heat addition due to solar irradiation resulted in a decreased fuel consumption rate. The influence of the additional pressure drop over the solar receiver was evident as it leads to decreased net power output. The new compressor increased the overall performance of the gas turbine and compensated for pressure losses incurred by the addition of solar components. The simulated integration of the solarized gas turbine at Helio100 showed potential, although the solar irradiation is too little to run the gas turbine on solar heat alone. The simulation evaluates the feasibility of solarizing a gas turbine and predicts plant performance for such a turbine cycle.