Don-Roger Parkinson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Don-Roger Parkinson has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- David Barter
Environmental Chemistry, Grenfell Campus, Memorial University of Newfoundland, Corner Brook, NL A2H 5G4, Canada
1 shared publication Dean W Strickland
1 shared publicationFranz Makeschin
1 shared publicationJamie Marcus Warren
Department of Chemistry, University of Waterloo, Waterloo, Ontario, Canada
1 shared publicationJanusz Pawliszyn
Department of Chemistry, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1
1 shared publicationLinda Kahnt
1 shared publication
Latest Publications
- Open Access
- 4 February 2016
- Published by MDPI AG in Separations
- Vol. 3 (1) , 5
Comparison of Spot and Time Weighted Averaging (TWA) Sampling with SPME-GC/MS Methods for Trihalomethane (THM) Analysis
Water samples were collected and analyzed for conductivity, pH, temperature and trihalomethanes (THMs) during the fall of 2014 at two monitored municipal drinking water source ponds. Both spot (or grab) and time weighted average (TWA) sampling methods were assessed over the same two day sampling time period. For spot sampling, replicate samples were taken at each site and analyzed within 12 h of sampling by both Headspace (HS)- and direct (DI)- solid phase microextraction (SPME) sampling/extraction methods followed by Gas Chromatography/Mass Spectrometry (GC/MS). For TWA, a two day passive on-site TWA sampling was carried out at the same sampling points in the ponds. All SPME sampling methods undertaken used a 65-µm PDMS/DVB SPME fiber, which was found optimal for THM sampling. Sampling conditions were optimized in the laboratory using calibration standards of chloroform, bromoform, bromodichloromethane, dibromochloromethane, 1,2-dibromoethane and 1,2-dichloroethane, prepared in aqueous solutions from analytical grade samples. Calibration curves for all methods with R2 values ranging from 0.985–0.998 (N = 5) over the quantitation linear range of 3–800 ppb were achieved. The different sampling methods were compared for quantification of the water samples, and results showed that DI- and TWA- sampling methods gave better data and analytical metrics. Addition of 10% wt./vol. of (NH4)2SO4 salt to the sampling vial was found to aid extraction of THMs by increasing GC peaks areas by about 10%, which resulted in lower detection limits for all techniques studied. However, for on-site TWA analysis of THMs in natural waters, the calibration standard(s) ionic strength conditions, must be carefully matched to natural water conditions to properly quantitate THM concentrations. The data obtained from the TWA method may better reflect actual natural water conditions.
- 4 February 2016
- Published by MDPI AG in Separations
- Vol. 3 (1) , 5
Open AccessComparison of Spot and Time Weighted Averaging (TWA) Sampling with SPME-GC/MS Methods for Trihalomethane (THM) Analysis
Water samples were collected and analyzed for conductivity, pH, temperature and trihalomethanes (THMs) during the fall of 2014 at two monitored municipal drinking water source ponds. Both spot (or grab) and time weighted average (TWA) sampling methods were assessed over the same two day sampling time period. For spot sampling, replicate samples were taken at each site and analyzed within 12 h of sampling by both Headspace (HS)- and direct (DI)- solid phase microextraction (SPME) sampling/extraction methods followed by Gas Chromatography/Mass Spectrometry (GC/MS). For TWA, a two day passive on-site TWA sampling was carried out at the same sampling points in the ponds. All SPME sampling methods undertaken used a 65-µm PDMS/DVB SPME fiber, which was found optimal for THM sampling. Sampling conditions were optimized in the laboratory using calibration standards of chloroform, bromoform, bromodichloromethane, dibromochloromethane, 1,2-dibromoethane and 1,2-dichloroethane, prepared in aqueous solutions from analytical grade samples. Calibration curves for all methods with R2 values ranging from 0.985–0.998 (N = 5) over the quantitation linear range of 3–800 ppb were achieved. The different sampling methods were compared for quantification of the water samples, and results showed that DI- and TWA- sampling methods gave better data and analytical metrics. Addition of 10% wt./vol. of (NH4)2SO4 salt to the sampling vial was found to aid extraction of THMs by increasing GC peaks areas by about 10%, which resulted in lower detection limits for all techniques studied. However, for on-site TWA analysis of THMs in natural waters, the calibration standard(s) ionic strength conditions, must be carefully matched to natural water conditions to properly quantitate THM concentrations. The data obtained from the TWA method may better reflect actual natural water conditions.
- 10 January 2013
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 61 (3) , 492-500
Assessment of Thiol Compounds from Garlic by Automated Headspace Derivatized In-Needle-NTD-GC-MS and Derivatized In-Fiber-SPME-GC-MS
This study investigates the analysis of thiol compounds using a needle trap device (HS-NTD) and solid-phase microextraction (HS-SPME) derivatized headspace techniques coupled to GC-MS. Thiol compounds and their outgassed products are particularly difficult to monitor in foodstuffs. It was found that with in-needle and in-fiber derivatization, using the derivatization agent N-phenylmaleimide, it was possible to enhance the selectivity toward thiol, which allowed the quantitation of butanethiol, ethanethiol, methanethiol, and propanethiol compounds found in fresh garlic. A side-hole NTD was prepared and packed in house and utilized mixed DVB and Carboxen polymer extraction phases made of 60–80 mesh particles. NTD sampling was accomplished in the exhaustive sampling mode, where breakthrough was negligible. This work demonstrates a new application for a side-hole NTD sampling. A commercial mixed polymer phase of polydimethylsiloxane (PDMS) and divinylbenzene polymer (DVB) SPME fiber was used for SPME extractions. Under optimized derivatization, extraction, and analysis conditions for both NTD-GC-MS and SPME-GC-MS techniques, automated sampling methods were developed for quantitation. Both methods demonstrate a successful approach to thiol determination and provide a quantitative linear response between –1 (R2 = 0.9996), with limits of detection (LOD) in the low micrograms per liter range for the investigated thiols. Addition methods using known spiked quantities of thiol analytes in ground garlic facilitated method validation. Carry-over was also negligible for both SPME and NTD under optimized conditions.
- 10 January 2013
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 61 (3) , 492-500
Assessment of Thiol Compounds from Garlic by Automated Headspace Derivatized In-Needle-NTD-GC-MS and Derivatized In-Fiber-SPME-GC-MS
This study investigates the analysis of thiol compounds using a needle trap device (HS-NTD) and solid-phase microextraction (HS-SPME) derivatized headspace techniques coupled to GC-MS. Thiol compounds and their outgassed products are particularly difficult to monitor in foodstuffs. It was found that with in-needle and in-fiber derivatization, using the derivatization agent N-phenylmaleimide, it was possible to enhance the selectivity toward thiol, which allowed the quantitation of butanethiol, ethanethiol, methanethiol, and propanethiol compounds found in fresh garlic. A side-hole NTD was prepared and packed in house and utilized mixed DVB and Carboxen polymer extraction phases made of 60–80 mesh particles. NTD sampling was accomplished in the exhaustive sampling mode, where breakthrough was negligible. This work demonstrates a new application for a side-hole NTD sampling. A commercial mixed polymer phase of polydimethylsiloxane (PDMS) and divinylbenzene polymer (DVB) SPME fiber was used for SPME extractions. Under optimized derivatization, extraction, and analysis conditions for both NTD-GC-MS and SPME-GC-MS techniques, automated sampling methods were developed for quantitation. Both methods demonstrate a successful approach to thiol determination and provide a quantitative linear response between –1 (R2 = 0.9996), with limits of detection (LOD) in the low micrograms per liter range for the investigated thiols. Addition methods using known spiked quantities of thiol analytes in ground garlic facilitated method validation. Carry-over was also negligible for both SPME and NTD under optimized conditions.
- 1 August 2007
- Published by Canadian Science Publishing in Canadian Journal of Soil Science
- Vol. 87 (4) , 455-458
Effect of forest harvesting and slash piling on microbial biomass and respiration in Newfoundland boreal forests
Clearcutting Newfoundland boreal forests significantly reduced organic layer fungal and total microbial biomass in clearcut areas with and without slash cover, compared with forested plots. However, aerobically incubated respiration rates were highest in organic layers from clearcut areas under slash, intermediate under forests, and lowest from clearcut areas without slash. Key words: Carbon, ergosterol, fumigation–extraction, fungal biomass, harvest slash, nitrogen
- 1 August 2007
- Published by Canadian Science Publishing in Canadian Journal of Soil Science
- Vol. 87 (4) , 455-458
Effect of forest harvesting and slash piling on microbial biomass and respiration in Newfoundland boreal forests
Clearcutting Newfoundland boreal forests significantly reduced organic layer fungal and total microbial biomass in clearcut areas with and without slash cover, compared with forested plots. However, aerobically incubated respiration rates were highest in organic layers from clearcut areas under slash, intermediate under forests, and lowest from clearcut areas without slash. Key words: Carbon, ergosterol, fumigation–extraction, fungal biomass, harvest slash, nitrogen