PSPrabin Shakya

Prabin Shakya

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Prabin Shakya has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Trends of Etiology and Drug Resistance in Enteric Fever in the Last Two Decades in Nepal: A Systematic Review and Meta-analysis

    by Surendra Karki, Prabin Shakya, Allen C. Cheng, Shyam Prakash Dumre, Karin Leder

    Prospective time–trend analyses on shifting etiology and trends of drug resistance in enteric fever are scarce. Using published and unpublished datasets from Nepal, we performed a systematic review and meta-analysis to understand the trends in etiology and resistance to antimicrobials that have occurred since 1993. Thirty-two studies involving 21 067 Salmonella enterica serotype Typhi (ST) and S. enterica serotype Paratyphi A (SPA) isolates were included. There was an increasing trend in enteric fever caused by SPA during the last 2 decades (P < .01). We observed sharply increasing trends in resistance to nalidixic acid and ciprofloxacin for both ST and SPA. In contrast, multi-drug resistance (MDR), resistance to traditional first-line antibiotics such as chloramphenicol and co-trimoxazole have significantly decreased for both organisms. The resistance to ceftriaxone has remained low, suggesting it is likely to remain useful as a reserve antibiotic for treatment. Trends in decreasing resistance to traditional first-line antibiotics and decreasing MDR provide an opportunity to reconsider these first-line antimicrobials as therapeutic options.


  • Open Access

    Evaluation of Physicochemical and Microbiological Parameters of Drinking Water Supplied from Distribution Systems of Kathmandu Municipality

    by Prabin Shakya, Tista P Joshi, Dev R Joshi, Dwij R Bhatta

    Microbial pathogens in drinking water are primary cause in gastrointestinal and waterborne diarrheal diseases. Public health authorities still have not achieved success in controlling the most common waterborne diseases in Nepal. The objective of this study was to assess the quality of drinking water supplied from distribution system of Kathmandu. A total of 114 water samples were collected from 4 distribution stations. The physicochemical and microbiological analyses of water were conducted. Heterotrophic plate count (HPC), detection of enteric pathogenic bacteria and antibiotics susceptibility test were done. Distinct variations in physicochemical parameters were observed. The mean free residual chlorine was found 0.24mg/l. Total Coliforms were found in 61.4% (70/114) of water samples among which 15.7% (11/70) had thermotolerant Coliforms. In distance, coliforms were found higher in far points (p=0.002). All thermotolerant Coliforms were identified as Escherichia coli. Mean HPC of water was found log103.15. The mean HPC of water (p=0.003) was found higher in far point. In collected samples, 10 different enteric bacteria were isolated in which E. coli was found most predominant followed by Pseudomonas spp., Citrobacter spp., Klebsiella spp., Shigella spp., Proteus spp., Enterobacter spp. Non-Typhii Salmonella spp., Providencia spp., Edwardsiella spp. In antibiotics susceptibility test, Gentamicin and Ofloxacin were found most efficient (100%) and whereas Ampicillin (11.5%) was least effective. Multiple antibiotics resistance was found among 5.3% of isolates. Nepal Journal of Science and Technology Vol. 13, No. 2 (2012) 179-184 DOI: http://dx.doi.org/10.3126/njst.v13i2.7733