GPGwenaël Pagé

Gwenaël Pagé

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gwenaël Pagé has a total of 128 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Functional brain imaging and targeted lesion studies using manganese-enhanced MRI and focused ultrasound in non-conventional model species

    by Pierre Estienne, Gwenaël Pagé, Théo Durier, Benoit Larrat, Kei Yamamoto, Luisa Ciobanu

  • Quantification et caractérisation des écoulements sanguins dans l'arborescence vasculaire de la région cervico-faciale par Imagerie par Résonance Magnétique de flux : évaluation et application

    by Gwenaël Pagé

    L'imagerie par résonance magnétique cinétique en contraste de phase (IRM-PC) sensible aux flux permet la quantification et la caractérisation des écoulements sanguins in-vivo de manière non-invasive. En clinique, cette séquence est principalement appliquée en une coupe à deux dimensions (2D), mais elle a évolué vers une acquisition volumique des vitesses (4D IRM-PC) offrant une quantification complète de l'écoulement dans l'ensemble d'une arborescence vasculaire. Cependant, cette technique nécessite d'outils de post-traitement qui sont encore peu nombreux et d'une évaluation de la précision de la mesure des vitesses en 2D et 4D dans des vaisseaux de petits diamètres. Dans ce travail de thèse, un logiciel de post-traitement des images 2D et 4D IRM-PC a été mis au point avec une interface facile et est utilisé par des équipes de recherches et des cliniciens. Des protocoles d'acquisitions des vitesses par IRM pour des vaisseaux constitués de diamètres millimétriques ont été développés. Ces protocoles ont été validés in-vitro à partir d'un travail réalisé sur fantôme qui montre une erreur inférieure à 10% dans la précision des mesures. Les protocoles validés ont été appliqués sur les artères de la région cervico-faciale chez 30 volontaires sains afin de constituer la première base hémodynamique des vaisseaux de cette région. Des patients atteints de pathologies cervico-faciale ont bénéficié de ce protocole et son intérêt a été montré dans le suivi du patient et pour la planification chirurgicale

  • MR elastography in patients with hepatocellular carcinoma: tumor stiffening during compression induced by respiration to assess microvascular invasion

    by Gwenaël Pagé, Philippe Garteiser, Valérie Paradis, Riccardo Sartoris, Estelle Marcault, Ralph Sinkus, Valérie Vilgrain, Bernard E. Van Beers

    Objectives Microvascular invasion is a strong prognostic factor in hepatocellular carcinomas. The aim of our study was to assess the diagnostic value of mechanical parameters measured with compression MR elastography to detect microvascular invasion in hepatocellular carcinomas. Materials and methods In this prospective preoperative MR elastographic study, consecutive patients with hepatocellular carcinomas, scheduled for tumor surgical resection, were included. The tumor parameters assessed with MR elastography were the basal visco-elastic parameters (storage modulus, loss modulus, and phase angle, reflecting elasticity, viscosity and visco-elastic ratio) during expiration and inspiration, and the tumor stiffening slope during compression induced by respiration, reflecting non-linear elasticity. Microvascular invasion was determined with histopathological examination of resected tumors. Diagnostic performance of MR elastography was assessed with area under the receiver operating curve (AUC) analysis. Results The final study group consisted of 53 patients with complete surgical resection, MR elastography and histological data, including 31 patients with microvascular invasion. Compression stiffening slope and storage modulus difference between inspiration and expiration were significantly higher in hepatocellular carcinomas without than with microvascular invasion (p < 0.001 and p = 0.03, respectively). Among clinical, morphological and biomechanical imaging features, the MR elastography compression stiffening slope (p = 0.004) and histological WHO differentiation (p = 0.02–0.03) were the only independent determinants of hepatocellular carcinoma microvascular invasion. In contrast to basal biomechanical parameters, the compression stiffening slope had high diagnostic performance for detecting microvascular invasion (AUCcompression stiffening = 0.83, p < 0.001). Conclusion Our results suggest that the compression stiffening slope at MR elastography is useful to diagnose microvascular invasion in patients with hepatocellular carcinomas. Key Points Question Because non-invasive imaging markers of hepatocellular microvascular invasion are lacking, the development of new MRI markers is advisable. Findings In our MR elastography study, respiration-induced tumor stiffening, in contrast to basal visco-elastic parameters, had good accuracy for diagnosing hepatocellular carcinoma microvascular invasion. Clinical relevance Our results in patients with hepatocellular carcinomas suggest that the non-invasive measurement of MR elastography tumor compression stiffening slope may assess microvascular invasion. Graphical Abstract

  • Open Access

    Problem-solving without a cortex: inferior lobe drives goal-directed object manipulation in cichlid fish

    by Pierre Estienne, Gwenaël Pagé, George Poon, Benoit Larrat, Théo Durier, Ambre Dufresne, Luisa Ciobanu, Kei Yamamoto

    Goal-directed object manipulation and problem-solving, which are necessary to evolve tool use behaviors, have long been linked to the expansion of the telencephalon in mammals and birds. Here, we show that goal-directed object manipulation in cichlid fish is driven by a non-telencephalic brain structure, the inferior lobe. Using manganese-enhanced MRI (MEMRI) on an ultra-high field 17.2 Tesla MRI system, we show that the inferior lobe is activated during a puzzle-box opening task. Furthermore, magnetic resonance (MR)-guided High Intensity Focused Ultrasound (HIFU) lesions profoundly impair fine motor coordination during this task without affecting general locomotion or motivation. These results reveal that cortex-like cognitive functions can arise from non-telencephalic brain structures in teleosts. With no homolog in tetrapods, the inferior lobe is a critical hub for flexible behavior in teleost fish. Our findings highlight the existence of alternative neural architectures for the emergence of complex cognition.

  • Improved feedback loop control for ultrasound-assisted blood–brain barrier opening in non-human primates based on the discrimination between intra- and extra-cerebral cavitation

    by Paul Mondou, Gwenaël Pagé, Corentin Cornu, Clémentine Morisset, Elias Djaballah, Audrey Fayard, Sophie Lecourtois, Marion Gay, Maxime Roustan, Julien Flament, et al.

    Objective. Temporary, non-invasive, and localized permeabilization of the blood–brain barrier (BBB) can be achieved through focused ultrasound and microbubbles (MB). This technique has been extensively employed in rodent and non-human primate (NHP) studies for testing various drugs but requires precise control of ultrasonic pressure. However, controlling cavitation in NHP is challenging due to their thicker skull inducing strong ultrasonic attenuation. Furthermore, extra-cranial cavitation may occur masking the cavitation signal at the focal region (cerebral cavitation). Particularly in larger male NHP, temporal muscles are highly perfused and filled with MB. Approach. This study proposes a feedback loop control strategy to distinguish between intra- and extra-cerebral cavitation by analyzing broadband noise recorded by passive cavitation detection sensors. Main results. The frequency-dependent low-pass filtering effect by the skull allows differentiation of distinct frequency components, providing insights into cavitation origin. The present study involved 17 BBB opening experiments in NHP. Significance. Although successful BBB disruption can be achieved in NHP with thin temporal muscles (15 mm) require the use of an optimized algorithm able to specifically extract the signature of intra-cerebral cavitation.


  • Comparison of ultrasound elastography, magnetic resonance elastography and finite element model to quantify nonlinear shear modulus

    by Gwenaël Pagé, Marion Bied, Philippe Garteiser, Bernard Van Beers, Nicolas Etaix, Christophe Fraschini, Aline Bel-Brunon, Jean-Luc Gennisson

    Objective . The aim of this study is to validate the estimation of the nonlinear shear modulus ( A ) from the acoustoelasticity theory with two experimental methods, ultrasound (US) elastography and magnetic resonance elastography (MRE), and a finite element method. Approach . Experiments were performed on agar (2%)—gelatin (8%) phantom considered as homogeneous, elastic and isotropic. Two specific setups were built to ensure a uniaxial stress step by step on the phantom, one for US and a nonmagnetic version for MRE. The stress was controlled identically in both imaging techniques, with a water tank placed on the top of the phantom and filled with increasing masses of water during the experiment. In US, the supersonic shear wave elastography was implemented on an ultrafast US device, driving a 6 MHz linear array to measure shear wave speed. In MRE, a gradient-echo sequence was used in which the three spatial directions of a 40 Hz continuous wave displacement generated with an external driver were encoded successively. Numerically, a finite element method was developed to simulate the propagation of the shear wave in a uniaxially stressed soft medium. Main results . Similar shear moduli were estimated at zero stress using experimental methods, μ 0 U S = 12.3 ± 0.3 kPa and μ 0 M R E = 11.5 ± 0.7 kPa. Numerical simulations were set with a shear modulus of 12 kPa and the resulting nonlinear shear modulus was found to be −58.1 ± 0.7 kPa. A very good agreement between the finite element model and the experimental models ( A U S = −58.9 ± 9.9 kPa and A M R E = −52.8 ± 6.5 kPa) was obtained. Significance . These results show the validity of such nonlinear shear modulus measurement quantification in shear wave elastography. This work paves the way to develop nonlinear elastography technique to get a new biomarker for medical diagnosis.


  • Open Access

    Comparative Analysis of a Locally Resampling MR Elastography Reconstruction Algorithm in Liver Fibrosis

    by Gwenaël Pagé, Felicia Julea, Valérie Paradis, Valérie Vilgrain, Dominique Valla, Bernard E. Van Beers, Philippe Garteiser

    Background: In magnetic resonance elastography (MRE), the precision of the observed mechanical depends on the ratio between mechanical wavelength and spatial resolution. Since the mechanical wavelength may vary with actuation frequency, between patients and depending on position, a unique spatial resolution may not always generate an optimal ratio for multifrequency acquisitions, in patients with varying degrees of disease or in mechanically heterogeneous organs.Purpose: To describe an MRE reconstruction algorithm that adjusts the ratio between shear wavelength and pixel size, by locally resampling the matrix of shear displacement, and to assess its performance relative to existing reconstructions in different use cases.Study Type: Prospective.Population: Four phantoms, 20 healthy volunteers (5 men, median age 34, range 20–56) and 46 patients with nonalcoholic fatty liver disease (37 men, median age 63, range 33–83).Field Strength/Sequence: A 3 T; gradient‐echo elastography sequence with 40 Hz, 60 Hz, and 80 Hz frequencies.Assessment: For each algorithm, phantoms stiffness were compared against their nominal values, repeatability was calculated in healthy volunteers, and diagnostic performance in detecting advanced liver fibrosis was assessed in 46 patients.Statistical Tests: Linear regression was used to evaluate the agreement between stiffness values and phantoms stiffnesses. Bland–Altman method was used to evaluate repeatability in volunteers. The ability to diagnose advanced fibrosis was assessed by receiver operating curve analysis (with Youden index thresholds). Significance was considered at P value of 0.05.Results: From the linear regression, the slope closest to 1 is provided by MARS (40 Hz) and k‐MDEV (60H, 80 Hz). Repeatability index was best with MDEV (23%) and lowest with k‐MDEV (53%). The best performance in detecting advanced fibrosis was provided by MARS at 40 Hz (area under the operating curve, AUC = 0.88), k‐MDEV and MARS at 60 Hz (AUC = 0.91), and multimodel direct inversion (MMDI) and MARS at 80 Hz (AUC = 0.90).Data Conclusion: MARS shows the best diagnostic performance to detect advanced fibrosis and the second‐best results in phantoms after k‐MDEV.Evidence Level: 1.Technical Efficacy: Stage 2.


  • Open Access

    Magnetic resonance elastography of malignant tumors

    by Gwenaël Pagé, Philippe Garteiser, Bernard E. Van Beers

    Cancer biomechanical properties, including high stiffness, solid stress, and interstitial pressure, as well as altered micro-architecture, are drivers of tumorigenesis, invasiveness and resistance to treatment. Magnetic resonance elastography is an emergent non-invasive imaging method to assess the tumor mechanical properties in a spatially resolved fashion. Several MRE acquisition and reconstruction methods have been developed to assess tumors and surrounding tissues. It is increasingly recognized that the visco-elastic properties assessed with MRE are useful for characterizing malignant tumors and evaluating treatment response in various organs. Generally, malignant tumors, except brain tumors, have high stiffness and high visco-elastic ratio or fluidity. MRE transducers, acquisition sequences and reconstruction algorithms are continuously improved to increase depth penetration and spatial resolution, and limit artifacts at spatial discontinuities. Moreover, assessment of compression stiffening might provide new biomarkers of the altered physical traits of cancer. Increasing research and clinical validation will improve the efficacy of MRE for cancer characterization.


  • Bases techniques de l’élastographie par résonance magnétique

    by A. Radzik, G. Pagé, M. Ronot, P. Garteiser, B.E. Van Beers