Georgy S. Ganchenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Georgy S. Ganchenko has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Evgeny A. Demekhin
Laboratory of Micro- and Nanoscale Electro- and Hydrodynamics, Financial University under the Government of the Russian Federation, Moscow, Russia
17 shared publications E. A. Demekhin
Laboratory of Micro- and Nanoscale Electro- and Hydrodynamics, Financial University 1 , Krasnodar 350051, Russian Federation
15 shared publications- Elizaveta Frants
Department of Mathematics and Computer Science, Financial University, Krasnodar 350051, Russian Federation
14 shared publications - S. Amiroudine
Institut de Mécanique et d’Ingénierie—TREFLE, UMR CNRS 5295, University of Bordeaux, 16 Avenue Pey-Berland, Pessac Cedex, France
10 shared publications - Vladimir S. Shelistov
Financial University under the Government of the Russian Federation, Moscow, Russia
8 shared publications S. Amiroudine
Institut de Mécanique et d'Ingénierie - TREFLE, UMR CNRS 5295, University of Bordeaux, 16 Avenue Pey-Berland, Pessac Cedex, France
7 shared publications
Latest Publications
- 1 April 2026
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 67 (2) , 189-196
Influence of External Flow on the Concentration of Charged Particles in the Wake of an Ion-Selective Granule
This study examines the behavior of a three-component electrolyte in a microdevice using a spherical ion-selective granule under an applied electric field and pressure gradient. In practical applications, one of the electrolyte components corresponds to charged analyte particles with an initially low concentration. It is shown that the analyte concentration in the granule wake can be increased, with the enrichment factor being independent of the initial concentration. The physical mechanism of this phenomenon is described, and the values of the potential and pressure differences and the characteristics of the electrolyte components and the granule required to achieve this enrichment are provided.
- 1 April 2026
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 67 (2) , 189-196
Influence of External Flow on the Concentration of Charged Particles in the Wake of an Ion-Selective Granule
This study examines the behavior of a three-component electrolyte in a microdevice using a spherical ion-selective granule under an applied electric field and pressure gradient. In practical applications, one of the electrolyte components corresponds to charged analyte particles with an initially low concentration. It is shown that the analyte concentration in the granule wake can be increased, with the enrichment factor being independent of the initial concentration. The physical mechanism of this phenomenon is described, and the values of the potential and pressure differences and the characteristics of the electrolyte components and the granule required to achieve this enrichment are provided.
- 7 June 2025
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 37 (3) , 1-14
Electrophoresis of an Ion-Selective Granule in the Oldroyd-B and FENE Fluids
- 7 June 2025
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 37 (3) , 1-14
Electrophoresis of an Ion-Selective Granule in the Oldroyd-B and FENE Fluids
- 1 June 2025
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 66 (3) , 446-456
Electrophoresis of an Ion-Selective Granule in Non-Newtonian Fluids in Moderate Electric Fields
The paper presents the results of numerical simulation of the electrophoresis of a single spherical ion-selective granule in a viscoelastic electrolyte within the Oldroyd-B and FENE-CR fluid models. The study is limited to weak and moderate electric fields, which corresponds to electrophoresis of the first kind. The dependence of the granule’s electrophoretic velocity on the polymer concentration and relaxation time is obtained.
- 1 June 2025
- Published by Pleiades Publishing Ltd in Journal of Applied Mechanics and Technical Physics
- Vol. 66 (3) , 446-456
Electrophoresis of an Ion-Selective Granule in Non-Newtonian Fluids in Moderate Electric Fields
The paper presents the results of numerical simulation of the electrophoresis of a single spherical ion-selective granule in a viscoelastic electrolyte within the Oldroyd-B and FENE-CR fluid models. The study is limited to weak and moderate electric fields, which corresponds to electrophoresis of the first kind. The dependence of the granule’s electrophoretic velocity on the polymer concentration and relaxation time is obtained.
- 22 March 2025
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 37 (2) , 1-10
Weakly Charged Analyte Concentration Scenarios Near an Ion-selective Microparticle
- 22 March 2025
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 37 (2) , 1-10
Weakly Charged Analyte Concentration Scenarios Near an Ion-selective Microparticle
- 4 April 2024
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 233 (8-9) , 1561-1572
Electrokinetic instability of a highly charged and weakly diffusing analyte in a buffer electrolyte near an ion-selective surface
- 4 April 2024
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 233 (8-9) , 1561-1572
Electrokinetic instability of a highly charged and weakly diffusing analyte in a buffer electrolyte near an ion-selective surface
- 25 April 2023
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 27 (5) , 1-8
Gravitation effect on concentration of ions near ion-selective microparticle
- 25 April 2023
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 27 (5) , 1-8
Gravitation effect on concentration of ions near ion-selective microparticle
- 24 August 2022
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 34 (5) , 1-11
Electrokinetic Instability in Viscoelastic Fluids in Microgravity Conditions
- 24 August 2022
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 34 (5) , 1-11
Electrokinetic Instability in Viscoelastic Fluids in Microgravity Conditions
- 3 August 2022
- Published by AIP Publishing
- Vol. 34 (8) , 084103
10.1063/5.0098652.1
The objective in the present work is to consider a simple example of instability of a conducting self-similar micro jet in the external electric field, which represents a prototype of some microfluidic instabilities. Salt from a point source is emitted into its own aquatic solution, which is subject to an external uniform velocity field together with an electrostatic field, and is convected downstream and diffused. The flow is considered in microscales so that, in contrast to the classical jets, the Reynolds numbers are practically zero, but the Péclet numbers are large. The parameters are found at which such a microjet is unstable. Along with the linear stability analysis, we have fulfilled the numerical simulations of the full nonlinear system of equations. The numerical simulation qualitatively confirmed the results of the linear stability and showed that this instability visually reminds classical instabilities of free jets and wakes.
- 3 August 2022
- Published by AIP Publishing
- Vol. 34 (8) , 084103
10.1063/5.0098652.1
The objective in the present work is to consider a simple example of instability of a conducting self-similar micro jet in the external electric field, which represents a prototype of some microfluidic instabilities. Salt from a point source is emitted into its own aquatic solution, which is subject to an external uniform velocity field together with an electrostatic field, and is convected downstream and diffused. The flow is considered in microscales so that, in contrast to the classical jets, the Reynolds numbers are practically zero, but the Péclet numbers are large. The parameters are found at which such a microjet is unstable. Along with the linear stability analysis, we have fulfilled the numerical simulations of the full nonlinear system of equations. The numerical simulation qualitatively confirmed the results of the linear stability and showed that this instability visually reminds classical instabilities of free jets and wakes.
- 1 August 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (8) , 084103
Instability of a salt jet emitted from a point source in an external electric field
The objective in the present work is to consider a simple example of instability of a conducting self-similar micro jet in the external electric field, which represents a prototype of some microfluidic instabilities. Salt from a point source is emitted into its own aquatic solution, which is subject to an external uniform velocity field together with an electrostatic field, and is convected downstream and diffused. The flow is considered in microscales so that, in contrast to the classical jets, the Reynolds numbers are practically zero, but the Péclet numbers are large. The parameters are found at which such a microjet is unstable. Along with the linear stability analysis, we have fulfilled the numerical simulations of the full nonlinear system of equations. The numerical simulation qualitatively confirmed the results of the linear stability and showed that this instability visually reminds classical instabilities of free jets and wakes.
- 1 August 2022
- Published by AIP Publishing in Physics of Fluids
- Vol. 34 (8) , 084103
Instability of a salt jet emitted from a point source in an external electric field
The objective in the present work is to consider a simple example of instability of a conducting self-similar micro jet in the external electric field, which represents a prototype of some microfluidic instabilities. Salt from a point source is emitted into its own aquatic solution, which is subject to an external uniform velocity field together with an electrostatic field, and is convected downstream and diffused. The flow is considered in microscales so that, in contrast to the classical jets, the Reynolds numbers are practically zero, but the Péclet numbers are large. The parameters are found at which such a microjet is unstable. Along with the linear stability analysis, we have fulfilled the numerical simulations of the full nonlinear system of equations. The numerical simulation qualitatively confirmed the results of the linear stability and showed that this instability visually reminds classical instabilities of free jets and wakes.
- 23 September 2021
- Published by Wiley in Electrophoresis
- Vol. 42 (23) , 2511-2518
Novel electroosmotic micromixer configuration based on ion‐selective microsphere
In this paper, a micromixer of a new configuration is presented, consisting of a spherical chamber in the center of which an ion‐selective microsphere is placed. Stratified liquid is introduced through the chamber via inlet and outlet holes under an external pressure gradient and an external electric field is directed in such a way that the resulting electroosmotic flow is directed against the pressure‐driven flow, resulting in mixing. The investigation is carried out by direct numerical simulation on a super‐computer. Optimal values of the applied electric field are determined to yield strong mixing. Above this optimal mixing regime, a number of instabilities and bifurcations are realized, which qualitatively coincide with those occurring during electrophoresis of an ion‐selective microgranule. As shown by our calculation, these instabilities do not lead to an enhanced mixing. The resulting electroconvective vortices remain confined near the surface of the microgranule, and do not sufficiently perturb the stratified fluid flow further from the granule. On the other hand, another type of instability caused by the salt concentration gradient can generate sufficiently strong oscillations to enhance mixing. However, this only occurs when the external electric field is sufficiently high that the electroosmotic flow is comparable to the pressure‐driven flow. This ultimately leads to creation of reverse flows of the liquid and cessation of the device operation. Thus, it was shown that the best mixing occurs in the absence of electrokinetic instability. Based on the data obtained, it is possible to select the necessary geometric characteristics of the micromixer to achieve the optimal mixing mode for a given set of liquids, which may be ten times more effective than passive mixers at the same flow rates. A comparison with the experimental data of the other authors confirms the effectiveness of this device and its other capabilities. Furthermore, the basic device design can be operated in other modes, for example, an electrohydrodynamic pump, a streaming current generator, or even a micro‐reactor, depending on the system parameters and choice of an ion‐selective granule.
- 23 September 2021
- Published by Wiley in Electrophoresis
- Vol. 42 (23) , 2511-2518
Novel electroosmotic micromixer configuration based on ion‐selective microsphere
In this paper, a micromixer of a new configuration is presented, consisting of a spherical chamber in the center of which an ion‐selective microsphere is placed. Stratified liquid is introduced through the chamber via inlet and outlet holes under an external pressure gradient and an external electric field is directed in such a way that the resulting electroosmotic flow is directed against the pressure‐driven flow, resulting in mixing. The investigation is carried out by direct numerical simulation on a super‐computer. Optimal values of the applied electric field are determined to yield strong mixing. Above this optimal mixing regime, a number of instabilities and bifurcations are realized, which qualitatively coincide with those occurring during electrophoresis of an ion‐selective microgranule. As shown by our calculation, these instabilities do not lead to an enhanced mixing. The resulting electroconvective vortices remain confined near the surface of the microgranule, and do not sufficiently perturb the stratified fluid flow further from the granule. On the other hand, another type of instability caused by the salt concentration gradient can generate sufficiently strong oscillations to enhance mixing. However, this only occurs when the external electric field is sufficiently high that the electroosmotic flow is comparable to the pressure‐driven flow. This ultimately leads to creation of reverse flows of the liquid and cessation of the device operation. Thus, it was shown that the best mixing occurs in the absence of electrokinetic instability. Based on the data obtained, it is possible to select the necessary geometric characteristics of the micromixer to achieve the optimal mixing mode for a given set of liquids, which may be ten times more effective than passive mixers at the same flow rates. A comparison with the experimental data of the other authors confirms the effectiveness of this device and its other capabilities. Furthermore, the basic device design can be operated in other modes, for example, an electrohydrodynamic pump, a streaming current generator, or even a micro‐reactor, depending on the system parameters and choice of an ion‐selective granule.