Christine Kamal Nessim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christine Kamal Nessim has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Hany Hunter Monir
Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo ET-11562, Egypt
3 shared publications - Hayam Mahmoud Lotfy
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Cairo University, El-Kasr El-Aini Street, Cairo, 11562, Egypt, cu.edu.eg
3 shared publications - Marwa I. Helmy
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Helwan University, Helwan 11795, Egypt
3 shared publications - Reem Hasan Obaydo
Department of Analytical and Food Chemistry, Faculty of Pharmacy Ebla Private University Idlib Syria
3 shared publications Adel M Michael
Analytical Chemistry Department, Faculty of Pharmacy, Ahram Canadian University, 12566, 6th October City, Giza, Egypt
2 shared publications- Adel Magdy Michael
Faculty of Pharmacy, Ahram Candian University, Cairo, Egypt
2 shared publications
Latest Publications
- 13 November 2026
- Published by Springer Nature in Chemistry Africa
- Vol. 9 (10)
Green and Sustainable Analytical Strategies for Memantine Hydrochloride Quantification in Pharmaceutical and Biological Matrices: A Comprehensive Review
- 13 November 2026
- Published by Springer Nature in Chemistry Africa
- Vol. 9 (10)
Green and Sustainable Analytical Strategies for Memantine Hydrochloride Quantification in Pharmaceutical and Biological Matrices: A Comprehensive Review
- Open Access
- 29 December 2025
- Published by Taylor & Francis in Green Chemistry Letters and Reviews
- Vol. 19 (1)
A novel turn-off functionalized potentiometric probe for antiparkinsonian drugs: advancing sustainability and white chemistry
- 29 December 2025
- Published by Taylor & Francis in Green Chemistry Letters and Reviews
- Vol. 19 (1)
Open AccessA novel turn-off functionalized potentiometric probe for antiparkinsonian drugs: advancing sustainability and white chemistry
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 077512
Bridging Pharma and Sustainability: Green Electrochemical Analysis of Antiparkinsonian Drug in Pharmaceuticals and Plasma, Aligned with United Nations Goals via the NQS Index
This study presents a sustainable electrochemical investigation of pramipexole (PRA) in pharmaceuticals and human plasma, using cyclic and differential pulse voltammetry. Key parameters, including potential range, buffer pH, accumulation period, and scan rate were optimized, establishing efficient voltammetric methods for PRA analysis. The analytical range was 0.60–12.00 μg ml−1, with a detection limit of 0.14 μg ml−1 and a correlation coefficient of 0.9998. Recovery rates for PRA ranged from 98.60 ± 0.26% to 101.33 ± 0.38%, validating the methodology’s applicability in human plasma with an average recovery of 99.25 ± 0.45%. The study highlights the environmental sustainability of the developed voltammetric electrode, evaluated through SWOT analysis, and assesses the greenness impact using tools like Complementary Green Analytical Procedure Index (ComplexGAPI), Analytical greenness (AGREE) and Analytical greenness for sample preparation (AGREEprep). Significantly, this work aligns with numerous United Nations Sustainable Development Goals (UN-SDGs), specifically goals 3, 4, 5, 7, 9, 11, 12, 13, 14, 15, and 17, illustrating our commitment to sustainable pharmaceutical research. The sustainability of the method was further quantified using the newly introduced Need, Quality, Sustainability (NQS) index, demonstrating significant alignment with sustainable analytical practices.
- 1 July 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (7) , 077512
Bridging Pharma and Sustainability: Green Electrochemical Analysis of Antiparkinsonian Drug in Pharmaceuticals and Plasma, Aligned with United Nations Goals via the NQS Index
This study presents a sustainable electrochemical investigation of pramipexole (PRA) in pharmaceuticals and human plasma, using cyclic and differential pulse voltammetry. Key parameters, including potential range, buffer pH, accumulation period, and scan rate were optimized, establishing efficient voltammetric methods for PRA analysis. The analytical range was 0.60–12.00 μg ml−1, with a detection limit of 0.14 μg ml−1 and a correlation coefficient of 0.9998. Recovery rates for PRA ranged from 98.60 ± 0.26% to 101.33 ± 0.38%, validating the methodology’s applicability in human plasma with an average recovery of 99.25 ± 0.45%. The study highlights the environmental sustainability of the developed voltammetric electrode, evaluated through SWOT analysis, and assesses the greenness impact using tools like Complementary Green Analytical Procedure Index (ComplexGAPI), Analytical greenness (AGREE) and Analytical greenness for sample preparation (AGREEprep). Significantly, this work aligns with numerous United Nations Sustainable Development Goals (UN-SDGs), specifically goals 3, 4, 5, 7, 9, 11, 12, 13, 14, 15, and 17, illustrating our commitment to sustainable pharmaceutical research. The sustainability of the method was further quantified using the newly introduced Need, Quality, Sustainability (NQS) index, demonstrating significant alignment with sustainable analytical practices.
- 10 May 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (5) , 749-760
Development and Evaluation of Chemometric Models for the Estimation of Sumatriptan in the Presence of Naproxen and a Degradation Product Using UV Spectrophotometry
Background: Chemometrics is a discipline that allows the spectral resolution of drugs in a pharmaceutical formulation along with degradation product and it is an alternative to chromatographic methods. Objective: Sumatriptan (SUM) is co-formulated with naproxen (NAP) and used in acute migraine attacks. SUM, which has physiological importance, has not been subjected to any stability-indicating chemometric approaches yet, so there is a need for an accurate and safe method for the assay of the cited drug in its preparations. The greenness and blueness assessment was applied using different ecological metrics, including the Green Analytical Procedure Index (GAPI), Analytical Greenness Metric (AGREE), Analytical Eco-Scale (AES) and new “blueness” evaluation using the Blue Applicability Grade Index (BAGI) tool. Methods: SUM was determined in pharmaceutical formulation along with NAP and in presence of alkali-induced degradation product with simple and cost-effective multivariate approaches using spectrophotometric data. Three chemometric approaches were applied for the stability-indicating determination of SUM in the presence of NAP. Classical least-squares (CLS), partial least-squares regression (PLS), and principal components regression (PCR)—three multivariate calibration numerical models that were applied to the UV spectra of the mixtures—were used to achieve the best resolution. Results: Sumatriptan was analyzed with mean accuracies for PLS (100.29% ± 1.318) and for PCR (100.60% ± 1.564). The presented methods were compared and validated for their quantitative analyses. Moreover, statistical comparison between the results obtained by the proposed models and the official methods showed no significant differences. Conclusion: The proposed multivariate calibrations were accurate and specific for quantitative analysis of the studied component. PLS is the best method that has the capacity for qualitative analysis of SUM and it is suitable for routine analysis and stability studies of SUM in QC laboratories. Various ecological assessment metrics confirmed the long-standing eco-friendliness of the suggested models. Highlights: Severally overlapped mixtures of SUM along with co-formulated drug NAP and an alkali-induced degradation product were analyzed by three chemometric approaches. The analytical performance of PLS and PCR was compared and validated in terms of root-mean-square error of calibration (RMSEC), SE of prediction, and recoveries. PLS gave the highest predicted concentrations with the lowest RMSEC and root-mean-square error of prediction. The standard addition was applied for accuracy assessment and the results were compared to those of official methods. Proposed models determined SUM in synthetic mixtures and pharmaceutical formulation in QC laboratories and stability studies. Ecological evaluation tools for measuring the environmental friendliness of chemicals were utilized for the first time in the analysis of SUM.
- 10 May 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (5) , 749-760
Development and Evaluation of Chemometric Models for the Estimation of Sumatriptan in the Presence of Naproxen and a Degradation Product Using UV Spectrophotometry
Background: Chemometrics is a discipline that allows the spectral resolution of drugs in a pharmaceutical formulation along with degradation product and it is an alternative to chromatographic methods. Objective: Sumatriptan (SUM) is co-formulated with naproxen (NAP) and used in acute migraine attacks. SUM, which has physiological importance, has not been subjected to any stability-indicating chemometric approaches yet, so there is a need for an accurate and safe method for the assay of the cited drug in its preparations. The greenness and blueness assessment was applied using different ecological metrics, including the Green Analytical Procedure Index (GAPI), Analytical Greenness Metric (AGREE), Analytical Eco-Scale (AES) and new “blueness” evaluation using the Blue Applicability Grade Index (BAGI) tool. Methods: SUM was determined in pharmaceutical formulation along with NAP and in presence of alkali-induced degradation product with simple and cost-effective multivariate approaches using spectrophotometric data. Three chemometric approaches were applied for the stability-indicating determination of SUM in the presence of NAP. Classical least-squares (CLS), partial least-squares regression (PLS), and principal components regression (PCR)—three multivariate calibration numerical models that were applied to the UV spectra of the mixtures—were used to achieve the best resolution. Results: Sumatriptan was analyzed with mean accuracies for PLS (100.29% ± 1.318) and for PCR (100.60% ± 1.564). The presented methods were compared and validated for their quantitative analyses. Moreover, statistical comparison between the results obtained by the proposed models and the official methods showed no significant differences. Conclusion: The proposed multivariate calibrations were accurate and specific for quantitative analysis of the studied component. PLS is the best method that has the capacity for qualitative analysis of SUM and it is suitable for routine analysis and stability studies of SUM in QC laboratories. Various ecological assessment metrics confirmed the long-standing eco-friendliness of the suggested models. Highlights: Severally overlapped mixtures of SUM along with co-formulated drug NAP and an alkali-induced degradation product were analyzed by three chemometric approaches. The analytical performance of PLS and PCR was compared and validated in terms of root-mean-square error of calibration (RMSEC), SE of prediction, and recoveries. PLS gave the highest predicted concentrations with the lowest RMSEC and root-mean-square error of prediction. The standard addition was applied for accuracy assessment and the results were compared to those of official methods. Proposed models determined SUM in synthetic mixtures and pharmaceutical formulation in QC laboratories and stability studies. Ecological evaluation tools for measuring the environmental friendliness of chemicals were utilized for the first time in the analysis of SUM.
- 16 April 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (4) , 549-557
Enhancing the Sustainability of Eco-Friendly Potentiometric Ion-Selective Electrodes for Stability-Indicating Measurement of Ethamsylate: Application in Bulk and Pharmaceutical Formulations
Through the use of sustainable and green chemistry concepts, scientists need to decrease waste, conserve energy, and develop safe substitutes for hazardous compounds, all for protecting and benefiting society and the environment. Four novel eco-friendly ion selective electrodes (ISE) were created to determine Ethamsylate (ETM) in bulk powder and different pharmaceutical formulations. The present electrodes were fabricated and evaluated to clearly distinguish ETM from a variety of inorganic, organic ions, sugars, some common drug excipients and the degradation product, hydroquinone (HQ) of ETM, and thus could be used for stability-indicating methods. The electrodes fabrication was based on 2-nitrophenyl octyl ether (NPOE) that was employed as a plasticizer in electrodes 1, 2, and 3 within a polymeric matrix of polyvinyl chloride (PVC) except for electrode 4, in which dibutyl sebacate was used as a plasticizer. Electrodes 1 & 2 were fabricated using tetra dodecyl ammonium bromide as an anionic exchanger and adding 4-sulfocalix-8-arene as an ionophore only to electrode 2, but electrode 1 prepared without incorporation of an ionophore. The fabrication of electrodes 3 & 4 was based on ethamsylate-tetraphenylborate (ETM-TPB) as an ion-association complex in a PVC matrix. The environmental sustainability was assessed using Green Analytical Procedure Index (GAPI), and Analytical Greenness Metric for Sample Preparation (AGREEprep). Electrodes 1 & 2 had linear dynamic ranges of (10−1—10 −5) and (10−1—10 −4) respectively, with a Nernstian slope of 49.6 and 53.2 mV/decade, respectively. Electrodes 3 & 4 had linear dynamic ranges of (10−1—10 −4), with a Nernstian slope of 43.9 and 40.2 mV/decade, respectively. The generated electrodes' selectivity coefficients showed good selectivity for ETM. The utility 4-sulfocalix-8-arene as ionophore had a significant influence on increasing the membrane sensitivity and selectivity of electrode 2 compared to other electrodes.
- 16 April 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (4) , 549-557
Enhancing the Sustainability of Eco-Friendly Potentiometric Ion-Selective Electrodes for Stability-Indicating Measurement of Ethamsylate: Application in Bulk and Pharmaceutical Formulations
Through the use of sustainable and green chemistry concepts, scientists need to decrease waste, conserve energy, and develop safe substitutes for hazardous compounds, all for protecting and benefiting society and the environment. Four novel eco-friendly ion selective electrodes (ISE) were created to determine Ethamsylate (ETM) in bulk powder and different pharmaceutical formulations. The present electrodes were fabricated and evaluated to clearly distinguish ETM from a variety of inorganic, organic ions, sugars, some common drug excipients and the degradation product, hydroquinone (HQ) of ETM, and thus could be used for stability-indicating methods. The electrodes fabrication was based on 2-nitrophenyl octyl ether (NPOE) that was employed as a plasticizer in electrodes 1, 2, and 3 within a polymeric matrix of polyvinyl chloride (PVC) except for electrode 4, in which dibutyl sebacate was used as a plasticizer. Electrodes 1 & 2 were fabricated using tetra dodecyl ammonium bromide as an anionic exchanger and adding 4-sulfocalix-8-arene as an ionophore only to electrode 2, but electrode 1 prepared without incorporation of an ionophore. The fabrication of electrodes 3 & 4 was based on ethamsylate-tetraphenylborate (ETM-TPB) as an ion-association complex in a PVC matrix. The environmental sustainability was assessed using Green Analytical Procedure Index (GAPI), and Analytical Greenness Metric for Sample Preparation (AGREEprep). Electrodes 1 & 2 had linear dynamic ranges of (10−1—10 −5) and (10−1—10 −4) respectively, with a Nernstian slope of 49.6 and 53.2 mV/decade, respectively. Electrodes 3 & 4 had linear dynamic ranges of (10−1—10 −4), with a Nernstian slope of 43.9 and 40.2 mV/decade, respectively. The generated electrodes' selectivity coefficients showed good selectivity for ETM. The utility 4-sulfocalix-8-arene as ionophore had a significant influence on increasing the membrane sensitivity and selectivity of electrode 2 compared to other electrodes.
- Open Access
- 1 January 2024
- Published by Walter de Gruyter GmbH in Reviews in Analytical Chemistry
- Vol. 43 (1)
KPI-based standards benchmarking for the preference of different analytical approaches developed for simultaneous determination of ciprofloxacin and hydrocortisone: A SWOT case study
This study aims to prefer the suitability of an analytical approach developed for simultaneously determining ciprofloxacin hydrochloride (CIP) and hydrocortisone (HYD) in their ear drop dosage form. The preference between the three known instruments was utilized, namely UV-spectrophotometry, reversed phase-high-performance liquid chromatography (RP-HPLC)-UV, and thin-layer chromatography (TLC)-densitometry. The instrumentational studies determined that the mathematical UV methods (utilized various manipulation designs such as the isoabsorptive point, absorbance ratio, extended ratio subtraction, ratio difference, and mean centering of ratio spectra) had linearities in the range of 2.0–14.0 and 1.0–14.0 µg·mL −1 , the RP-HPLC-UV method showed a linearity range of 1.0–8.0 µg·mL −1 , and the TLC-spectrodensitometric method had linearity ranges of 0.2–1.6 µg/band and 0.6–2.0 µg/band for both CIP and HYD, respectively. The analytical performance, validity, and greenness of the approaches were evaluated through the benchmarking of key performance indicator (KPI)-based standards and a SWOT (strengths, weaknesses, opportunities, and threats) analysis. The KPIs and SWOT study focused on several aspects, including (1) the selectivity and robustness of the methods, (2) sensitivity, (3) accuracy and precision, (4) applicability, (5) whiteness, (6) greenness, and (7) blueness. However, the assessment of whiteness, greenness, and blueness was conducted using well-known ecological assessment tools such as the RGB12 Algorithm, Analytical Eco-Scale, AGREE, GAPI, and Blue Applicability Grade Index. In conclusion, based on the findings, UV-spectrophotometry emerged as the most practically convenient approach. It demonstrated advantages based on the predetermined KPI-based standards. Furthermore, UV-spectrophotometry was deemed to be the most environmentally friendly option.
- 1 January 2024
- Published by Walter de Gruyter GmbH in Reviews in Analytical Chemistry
- Vol. 43 (1)
Open AccessKPI-based standards benchmarking for the preference of different analytical approaches developed for simultaneous determination of ciprofloxacin and hydrocortisone: A SWOT case study
This study aims to prefer the suitability of an analytical approach developed for simultaneously determining ciprofloxacin hydrochloride (CIP) and hydrocortisone (HYD) in their ear drop dosage form. The preference between the three known instruments was utilized, namely UV-spectrophotometry, reversed phase-high-performance liquid chromatography (RP-HPLC)-UV, and thin-layer chromatography (TLC)-densitometry. The instrumentational studies determined that the mathematical UV methods (utilized various manipulation designs such as the isoabsorptive point, absorbance ratio, extended ratio subtraction, ratio difference, and mean centering of ratio spectra) had linearities in the range of 2.0–14.0 and 1.0–14.0 µg·mL −1 , the RP-HPLC-UV method showed a linearity range of 1.0–8.0 µg·mL −1 , and the TLC-spectrodensitometric method had linearity ranges of 0.2–1.6 µg/band and 0.6–2.0 µg/band for both CIP and HYD, respectively. The analytical performance, validity, and greenness of the approaches were evaluated through the benchmarking of key performance indicator (KPI)-based standards and a SWOT (strengths, weaknesses, opportunities, and threats) analysis. The KPIs and SWOT study focused on several aspects, including (1) the selectivity and robustness of the methods, (2) sensitivity, (3) accuracy and precision, (4) applicability, (5) whiteness, (6) greenness, and (7) blueness. However, the assessment of whiteness, greenness, and blueness was conducted using well-known ecological assessment tools such as the RGB12 Algorithm, Analytical Eco-Scale, AGREE, GAPI, and Blue Applicability Grade Index. In conclusion, based on the findings, UV-spectrophotometry emerged as the most practically convenient approach. It demonstrated advantages based on the predetermined KPI-based standards. Furthermore, UV-spectrophotometry was deemed to be the most environmentally friendly option.
- 1 December 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (2) , 226-233
Utility of N-Bromosuccinimide–Water Combination as a Green Reagents for a Validated Indirect Spectrophotometric Determination of Some Antihypertensive Drugs: An Application to Their Monitoring in Marketed Tablets and Capsules
Analytical test was conducted to investigate the use of N-bromosuccinimide (NBS) as an important safe analytical reagent for the spectrophotometric detection of therapeutically significant dihydropyridine-based calcium antagonists (DHP) namely nifedipine (NIF) and amlodipine (AML) that have been demonstrated to possess antioxidant activity in vivo and to reduce the intracellular production of reactive oxygen species (ROS). Following DHP and NBS reaction in acidic media, the excess NBS was evaluated for the first time by its interaction with P-aminophenol (PAP), which produced a violet colored product that was detected at 556 nm. Under the optimal reaction conditions, the analytical method was performed and validated since different variables disturbing the reaction (concentration of reagent, type and concentration of the selected acid, reaction time and the diluting solvents) were carefully studied and optimized. The stoichiometry of the applied reaction was performed by Job's method of continuous variation. Monitoring of these drugs dosage forms-content uniformity is a first tool or evidence for their efficacy and safety after their administration. Beer's law was obeyed in the concentration range of (1.25–11.0 µg/mL) for NIF and (1.25–10.0 µg/mL) for AML. The calculated limits of detection and quantification for NIF and AML were (0.220, 0.155 µg/mL) and (0.519, 0.735 µg/mL), respectively. The precision of the applied method was satisfactory; the values of (RSD) did not exceed 2%. Two greenness assessment tools, such as the green analytical procedure index (GAPI) and Analytical Greenness Metric for Sample Preparation (AGREEprep) were used for measuring the environmental friendliness of the recommended method. As the initial stage in ensuring the effectiveness and safety of these medications after administration, the micro-determinations of content uniformity for NIF and AML in their pharmaceutical dosage forms were extremely comparable with those from official and validated procedures. A validated Indirect spectrophotometric method for accurate quantification of some of 1,4-dihydropyridine drugs using N-bromosuccinimide with the aid of P-aminophenol Monitoring of nifedipine and amlodipine dosage forms-content uniformity as a first tool or evidence for their efficacy and safety after their administration. Greenness Evaluation Tools such as, GAPI & AGREEprep for measuring the environmental friendliness of the recommended method.
- 1 December 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (2) , 226-233
Utility of N-Bromosuccinimide–Water Combination as a Green Reagents for a Validated Indirect Spectrophotometric Determination of Some Antihypertensive Drugs: An Application to Their Monitoring in Marketed Tablets and Capsules
Analytical test was conducted to investigate the use of N-bromosuccinimide (NBS) as an important safe analytical reagent for the spectrophotometric detection of therapeutically significant dihydropyridine-based calcium antagonists (DHP) namely nifedipine (NIF) and amlodipine (AML) that have been demonstrated to possess antioxidant activity in vivo and to reduce the intracellular production of reactive oxygen species (ROS). Following DHP and NBS reaction in acidic media, the excess NBS was evaluated for the first time by its interaction with P-aminophenol (PAP), which produced a violet colored product that was detected at 556 nm. Under the optimal reaction conditions, the analytical method was performed and validated since different variables disturbing the reaction (concentration of reagent, type and concentration of the selected acid, reaction time and the diluting solvents) were carefully studied and optimized. The stoichiometry of the applied reaction was performed by Job's method of continuous variation. Monitoring of these drugs dosage forms-content uniformity is a first tool or evidence for their efficacy and safety after their administration. Beer's law was obeyed in the concentration range of (1.25–11.0 µg/mL) for NIF and (1.25–10.0 µg/mL) for AML. The calculated limits of detection and quantification for NIF and AML were (0.220, 0.155 µg/mL) and (0.519, 0.735 µg/mL), respectively. The precision of the applied method was satisfactory; the values of (RSD) did not exceed 2%. Two greenness assessment tools, such as the green analytical procedure index (GAPI) and Analytical Greenness Metric for Sample Preparation (AGREEprep) were used for measuring the environmental friendliness of the recommended method. As the initial stage in ensuring the effectiveness and safety of these medications after administration, the micro-determinations of content uniformity for NIF and AML in their pharmaceutical dosage forms were extremely comparable with those from official and validated procedures. A validated Indirect spectrophotometric method for accurate quantification of some of 1,4-dihydropyridine drugs using N-bromosuccinimide with the aid of P-aminophenol Monitoring of nifedipine and amlodipine dosage forms-content uniformity as a first tool or evidence for their efficacy and safety after their administration. Greenness Evaluation Tools such as, GAPI & AGREEprep for measuring the environmental friendliness of the recommended method.
- 18 February 2021
- Published by Wiley in Journal of Food Science
- Vol. 86 (3) , 1162-1171
When is it safe to eat different broiler chicken tissues after administration of doxycycline and tylosin mixture?
Residues of veterinary drugs in poultry meat have serious health effects on humans (e.g., antimicrobial resistance, carcinogenicity, and hypersensitivity), which make the control of veterinary drug residues an important parameter in ensuring consumer protection. This work was performed to quantitatively determine two co‐formulated anti‐infective veterinary agents, tylosin tartrate (TYT) and doxycycline hydrochloride (DOX) in different tissues of broiler chickens (liver, muscles, and fat) using high performance liquid chromatography. The chicken was treated with the recommended dose of a binary mixture of the drugs (Tydovet). Moreover, the study aimed to estimate the withdrawal time of both drugs in chicken tissues. The analysis was done by solvent extraction and solid‐phase extraction for clean‐up of samples from the tissue matrix, followed by liquid chromatographic determination of the cited drugs with UV‐detection. Residue decline with time was tracked, and both antibiotics were found to be more persistent in liver tissues than other tissues (muscle and fat). The effect of freezing and cooking was investigated on tissue residue levels. While freezing had little effect on the concentration of both antibiotics; cooking, as anticipated, led to a marked decline. Therefore, it is recommended to pay attention to the proper withdrawal periods before marketing to ensure the hygienic suitability of broilers edibles for safe human consumption. Practical Application: This novel study measures tylosin and doxycycline residues simultaneously in different tissues (muscle, fat, and liver) after administration of Tydovet powder to the broiler chicken. Residues in fat persisted for a longer time than in muscle in case of TYT, whereas the reverse was noticed in DOX.
- 18 February 2021
- Published by Wiley in Journal of Food Science
- Vol. 86 (3) , 1162-1171
When is it safe to eat different broiler chicken tissues after administration of doxycycline and tylosin mixture?
Residues of veterinary drugs in poultry meat have serious health effects on humans (e.g., antimicrobial resistance, carcinogenicity, and hypersensitivity), which make the control of veterinary drug residues an important parameter in ensuring consumer protection. This work was performed to quantitatively determine two co‐formulated anti‐infective veterinary agents, tylosin tartrate (TYT) and doxycycline hydrochloride (DOX) in different tissues of broiler chickens (liver, muscles, and fat) using high performance liquid chromatography. The chicken was treated with the recommended dose of a binary mixture of the drugs (Tydovet). Moreover, the study aimed to estimate the withdrawal time of both drugs in chicken tissues. The analysis was done by solvent extraction and solid‐phase extraction for clean‐up of samples from the tissue matrix, followed by liquid chromatographic determination of the cited drugs with UV‐detection. Residue decline with time was tracked, and both antibiotics were found to be more persistent in liver tissues than other tissues (muscle and fat). The effect of freezing and cooking was investigated on tissue residue levels. While freezing had little effect on the concentration of both antibiotics; cooking, as anticipated, led to a marked decline. Therefore, it is recommended to pay attention to the proper withdrawal periods before marketing to ensure the hygienic suitability of broilers edibles for safe human consumption. Practical Application: This novel study measures tylosin and doxycycline residues simultaneously in different tissues (muscle, fat, and liver) after administration of Tydovet powder to the broiler chicken. Residues in fat persisted for a longer time than in muscle in case of TYT, whereas the reverse was noticed in DOX.
- Open Access
- 26 January 2021
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 59 (8) , 776-784
A Thorough HPLC Assay of Quaternary Veterinary Formulation coupled with Environmental Assessment Tool
A new and accurate reversed phase HPLC method with UV detection has been established for any veterinarian analyst for simultaneous determination of a veterinary quaternary mixture of sulphadimidine sodium (SDS), sulphaquinoxaline sodium (SQS), diaveridine (DVD) and vitamin K3 (VTK3) in their formulation. The stationary phase was SEA C18 column (250 × 4.6 mm i.d., 5 μm particle size) at 25°C with an isocratic mode, using a mobile phase containing a mixture of methanol:acetonitrile:distilled water in the ratio of (20:20:60, by volume). The flow rate was 0.8 mL min−1, and UV detection was performed at 230 nm. The HPLC assay was coupled with Environmental Assessment Tool (EAT), which represents a simple and proficient approach for profiling the greenness of the method. This takes into consideration the environmental, health and safety issues for all solvents that involved in the chromatographic method and calculates a total score that can be used for comparison of the greenness of different methods. The method was found to be linear over (0.5–30) μg/mL for all cited drugs with mean percentage recoveries (99.56 ± 1.141) for VTK3, (99.56 ± 1.056) for DVD, (99.62 ± 1.482) for SDS and (99.52 ± 1.205) for SQS. The results were statistically compared with those of the official and reported methods; using Student’s t-test and F-test, showing no significant difference with respect to accuracy. Specificity of the applied method was assessed by analyzing the laboratory-prepared mixtures. The developed method was validated according to ICH guidelines. The proposed methodology can be applied for rapid routine assay of this combination.
- 26 January 2021
- Published by Oxford University Press (OUP) in Journal of Chromatographic Science
- Vol. 59 (8) , 776-784
Open AccessA Thorough HPLC Assay of Quaternary Veterinary Formulation coupled with Environmental Assessment Tool
A new and accurate reversed phase HPLC method with UV detection has been established for any veterinarian analyst for simultaneous determination of a veterinary quaternary mixture of sulphadimidine sodium (SDS), sulphaquinoxaline sodium (SQS), diaveridine (DVD) and vitamin K3 (VTK3) in their formulation. The stationary phase was SEA C18 column (250 × 4.6 mm i.d., 5 μm particle size) at 25°C with an isocratic mode, using a mobile phase containing a mixture of methanol:acetonitrile:distilled water in the ratio of (20:20:60, by volume). The flow rate was 0.8 mL min−1, and UV detection was performed at 230 nm. The HPLC assay was coupled with Environmental Assessment Tool (EAT), which represents a simple and proficient approach for profiling the greenness of the method. This takes into consideration the environmental, health and safety issues for all solvents that involved in the chromatographic method and calculates a total score that can be used for comparison of the greenness of different methods. The method was found to be linear over (0.5–30) μg/mL for all cited drugs with mean percentage recoveries (99.56 ± 1.141) for VTK3, (99.56 ± 1.056) for DVD, (99.62 ± 1.482) for SDS and (99.52 ± 1.205) for SQS. The results were statistically compared with those of the official and reported methods; using Student’s t-test and F-test, showing no significant difference with respect to accuracy. Specificity of the applied method was assessed by analyzing the laboratory-prepared mixtures. The developed method was validated according to ICH guidelines. The proposed methodology can be applied for rapid routine assay of this combination.