Richard A. Jones
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Richard A. Jones has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
J. Damien Grattan-Smith
Emory University School of Medicine/Children’s Healthcare of Atlanta
5 shared publicationsAndrew J. Kirsch
Department of Pediatric Urology, Emory University School of Medicine, Atlanta, GA
2 shared publicationsJ. Damien Grattan‐Smith
Department of Radiology, Children's Healthcare of Atlanta, Atlanta, Georgia, USA
2 shared publicationsStephen B. Little
Children’s Healthcare of Atlanta
2 shared publicationsSusan Palasis
2 shared publications- Aart. J. van der Molen
Department of Radiology, C-2S, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication
Latest Publications
- Open Access
Consensus-based technical recommendations for clinical translation of renal Dynamic Contrast-Enhanced (DCE) MRI
Background: Dynamic contrast-enhanced (DCE) MRI has the potential to be a useful tool for non-invasively assessing renal haemodynamics and function, however insufficient standardisation and difficulties in post-processing remain barriers to clinical translation. Purpose: To develop expert consensus-based technical recommendations for performing renal DCE-MRI in humans, relating to aspects of patient preparation, MRI hardware and acquisition parameters, and data analysis. Study Type: Systematic consensus process using an approximation to the two-step modified Delphi method. Population: Not applicable. Field Strength / Sequence: 1.5 T and 3 T / Renal gradient echo-based 3D DCE-MRI. Assessment: An international panel of experts were recruited and surveyed following a modified Delphi method to create consensus-based technical recommendations. Key areas for consensus were initially identified through a mixture of online and in-person discussions, and an initial survey round consisting of open- and close-ended questions. Consensus statements were formulated and iteratively refined to create the final recommendations. Statistical Tests: Consensus was defined as ≥ 75% agreement in response (excluding abstentions), and clear preference was defined as [60-74]% agreement among the experts. Statements with ≥40% abstentions were either excluded from subsequent survey rounds or recirculated as a modified statement. Results: 22 experts initially participated in the Delphi panel, of which 16 responded to the first survey. 15 panellists responded to all subsequent surveys. Out of 46 statements, 37 reached consensus and one showed clear preference. ≥40% abstention was found in seven statements which were excluded from the final set of recommendations. Data conclusion: These recommendations provide a starting point for MRI centres worldwide wishing to perform renal DCE-MRI, contributing to the harmonisation of DCE-MRI scan protocols and facilitating clinical translation. These recommendations provide a practical minimum technical dataset for renal DCE-MRI acquisition and analysis to improve cross-site comparability and support responsible clinical translation.
Open AccessConsensus-based technical recommendations for clinical translation of renal Dynamic Contrast-Enhanced (DCE) MRI
Background: Dynamic contrast-enhanced (DCE) MRI has the potential to be a useful tool for non-invasively assessing renal haemodynamics and function, however insufficient standardisation and difficulties in post-processing remain barriers to clinical translation. Purpose: To develop expert consensus-based technical recommendations for performing renal DCE-MRI in humans, relating to aspects of patient preparation, MRI hardware and acquisition parameters, and data analysis. Study Type: Systematic consensus process using an approximation to the two-step modified Delphi method. Population: Not applicable. Field Strength / Sequence: 1.5 T and 3 T / Renal gradient echo-based 3D DCE-MRI. Assessment: An international panel of experts were recruited and surveyed following a modified Delphi method to create consensus-based technical recommendations. Key areas for consensus were initially identified through a mixture of online and in-person discussions, and an initial survey round consisting of open- and close-ended questions. Consensus statements were formulated and iteratively refined to create the final recommendations. Statistical Tests: Consensus was defined as ≥ 75% agreement in response (excluding abstentions), and clear preference was defined as [60-74]% agreement among the experts. Statements with ≥40% abstentions were either excluded from subsequent survey rounds or recirculated as a modified statement. Results: 22 experts initially participated in the Delphi panel, of which 16 responded to the first survey. 15 panellists responded to all subsequent surveys. Out of 46 statements, 37 reached consensus and one showed clear preference. ≥40% abstention was found in seven statements which were excluded from the final set of recommendations. Data conclusion: These recommendations provide a starting point for MRI centres worldwide wishing to perform renal DCE-MRI, contributing to the harmonisation of DCE-MRI scan protocols and facilitating clinical translation. These recommendations provide a practical minimum technical dataset for renal DCE-MRI acquisition and analysis to improve cross-site comparability and support responsible clinical translation.
- Open Access
- 23 May 2024
- Published by American Society of Hematology in Blood
- Vol. 143 (21) , 2145-2151
The influence of voxelotor on cerebral blood flow and oxygen extraction in pediatric sickle cell disease
Voxelotor is an inhibitor of sickle hemoglobin polymerization that is used to treat sickle cell disease. Although voxelotor has been shown to improve anemia, the clinical benefit on the brain remains to be determined. This study quantified the cerebral hemodynamic effects of voxelotor in children with sickle cell anemia (SCA) using noninvasive diffuse optical spectroscopies. Specifically, frequency-domain near-infrared spectroscopy combined with diffuse correlation spectroscopy were used to noninvasively assess regional oxygen extraction fraction (OEF), cerebral blood volume, and an index of cerebral blood flow (CBFi). Estimates of CBFi were first validated against arterial spin–labeled magnetic resonance imaging (ASL-MRI) in 8 children with SCA aged 8 to 18 years. CBFi was significantly positively correlated with ASL-MRI–measured blood flow (R2 = 0.651; P = .015). Next, a single-center, open-label pilot study was completed in 8 children with SCA aged 4 to 17 years on voxelotor, monitored before treatment initiation and at 4, 8, and 12 weeks (NCT05018728). By 4 weeks, both OEF and CBFi significantly decreased, and these decreases persisted to 12 weeks (both P < .05). Decreases in CBFi were significantly correlated with increases in blood hemoglobin (Hb) concentration (P = .025), whereas the correlation between decreases in OEF and increases in Hb trended toward significance (P = .12). Given that previous work has shown that oxygen extraction and blood flow are elevated in pediatric SCA compared with controls, these results suggest that voxelotor may reduce cerebral hemodynamic impairments. This trial was registered at www.ClinicalTrials.gov as #NCT05018728.
- 23 May 2024
- Published by American Society of Hematology in Blood
- Vol. 143 (21) , 2145-2151
Open AccessThe influence of voxelotor on cerebral blood flow and oxygen extraction in pediatric sickle cell disease
Voxelotor is an inhibitor of sickle hemoglobin polymerization that is used to treat sickle cell disease. Although voxelotor has been shown to improve anemia, the clinical benefit on the brain remains to be determined. This study quantified the cerebral hemodynamic effects of voxelotor in children with sickle cell anemia (SCA) using noninvasive diffuse optical spectroscopies. Specifically, frequency-domain near-infrared spectroscopy combined with diffuse correlation spectroscopy were used to noninvasively assess regional oxygen extraction fraction (OEF), cerebral blood volume, and an index of cerebral blood flow (CBFi). Estimates of CBFi were first validated against arterial spin–labeled magnetic resonance imaging (ASL-MRI) in 8 children with SCA aged 8 to 18 years. CBFi was significantly positively correlated with ASL-MRI–measured blood flow (R2 = 0.651; P = .015). Next, a single-center, open-label pilot study was completed in 8 children with SCA aged 4 to 17 years on voxelotor, monitored before treatment initiation and at 4, 8, and 12 weeks (NCT05018728). By 4 weeks, both OEF and CBFi significantly decreased, and these decreases persisted to 12 weeks (both P < .05). Decreases in CBFi were significantly correlated with increases in blood hemoglobin (Hb) concentration (P = .025), whereas the correlation between decreases in OEF and increases in Hb trended toward significance (P = .12). Given that previous work has shown that oxygen extraction and blood flow are elevated in pediatric SCA compared with controls, these results suggest that voxelotor may reduce cerebral hemodynamic impairments. This trial was registered at www.ClinicalTrials.gov as #NCT05018728.
- Open Access
- 18 September 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (18) , 2973
Diagnostic Excellence in Pediatric Spine Imaging: Using Contextualized Imaging Protocols
Contextual design and selection of MRI protocols is critical for making an accurate diagnosis given the wide variety of clinical indications for spine imaging in children. Here, we describe our pediatric spine imaging protocols in detail, tailored to specific clinical questions.
- 18 September 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (18) , 2973
Open AccessDiagnostic Excellence in Pediatric Spine Imaging: Using Contextualized Imaging Protocols
Contextual design and selection of MRI protocols is critical for making an accurate diagnosis given the wide variety of clinical indications for spine imaging in children. Here, we describe our pediatric spine imaging protocols in detail, tailored to specific clinical questions.
- Open Access
- 13 April 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (6) , 1242-1247
Differences in Activation and Deactivation in Children with Sickle Cell Disease Compared with Demographically Matched Controls
BACKGROUND AND PURPOSE: Declines in both functional activation and functional connectivity have been reported in patients with sickle cell disease. In this study, we derived the functional and default mode responses to a word stem paradigm in age-, ethnicity-, and background-matched subjects with sickle cell disease and control groups, with the aim of testing whether both networks were similarly attenuated and whether the changes were related to physiologic parameters that characterize sickle cell disease. MATERIALS AND METHODS: Both the functional and default mode responses were obtained from age- and background-matched controls and the sickle cell population by using a visually presented word stem paradigm on a 3T scanner. RESULTS: We observed an attenuated response to both activation and deactivation in the sickle cell disease group. There were no significant differences in the activation response between the 2 groups for the contrast control > sickle cell disease; however, significant differences were observed in the medial parietal cortex, the auditory cortex, and the angular gyrus for the default mode. For the sickle cell group, a significant correlation between the activation z scores and the physiologic parameters was observed; for the deactivation, the results were not significant but the trend was similar. CONCLUSIONS: The results indicate that the physiologic parameters modulate the activation in the expected fashion, but that the effect was weaker for deactivation. Given that significant differences between the 2 groups were only seen for deactivation, additional factors must modulate the deactivation in sickle cell disease.
- 13 April 2017
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (6) , 1242-1247
Open AccessDifferences in Activation and Deactivation in Children with Sickle Cell Disease Compared with Demographically Matched Controls
BACKGROUND AND PURPOSE: Declines in both functional activation and functional connectivity have been reported in patients with sickle cell disease. In this study, we derived the functional and default mode responses to a word stem paradigm in age-, ethnicity-, and background-matched subjects with sickle cell disease and control groups, with the aim of testing whether both networks were similarly attenuated and whether the changes were related to physiologic parameters that characterize sickle cell disease. MATERIALS AND METHODS: Both the functional and default mode responses were obtained from age- and background-matched controls and the sickle cell population by using a visually presented word stem paradigm on a 3T scanner. RESULTS: We observed an attenuated response to both activation and deactivation in the sickle cell disease group. There were no significant differences in the activation response between the 2 groups for the contrast control > sickle cell disease; however, significant differences were observed in the medial parietal cortex, the auditory cortex, and the angular gyrus for the default mode. For the sickle cell group, a significant correlation between the activation z scores and the physiologic parameters was observed; for the deactivation, the results were not significant but the trend was similar. CONCLUSIONS: The results indicate that the physiologic parameters modulate the activation in the expected fashion, but that the effect was weaker for deactivation. Given that significant differences between the 2 groups were only seen for deactivation, additional factors must modulate the deactivation in sickle cell disease.
- Open Access
- 17 May 2012
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 33 (11) , 2043-2049
White Matter Damage in Asymptomatic Patients with Sickle Cell Anemia: Screening with Diffusion Tensor Imaging
Ischemic injury to the brain is a common complication of SCA. To better understand the neurologic impact of SCA, TBSS were applied to DTI data to investigate white matter injuries in pediatric patients with SCA. TBSS comparisons of a range of anisotropy and diffusion measures were carried out between age- and background-matched population groups: patients with SCA with no visible lesions, patients with SCA with mild gliosis, and normal controls. TBSS analysis revealed that both SCA populations exhibited reduced anisotropy and increased diffusivity compared with normal controls in multiple brain regions, including the corpus callosum and centrum semiovale. Furthermore, the results suggest that the severity of SCA is positively correlated with the white matter changes in the corpus callosum. The study demonstrates that TBSS is a viable technique in detecting subtle white matter damage in patients with SCA whose conventional anatomic MR imaging scans show no, or minimal, abnormalities and has the potential to evaluate the neurologic impact of the treatment of SCA.
- 17 May 2012
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 33 (11) , 2043-2049
Open AccessWhite Matter Damage in Asymptomatic Patients with Sickle Cell Anemia: Screening with Diffusion Tensor Imaging
Ischemic injury to the brain is a common complication of SCA. To better understand the neurologic impact of SCA, TBSS were applied to DTI data to investigate white matter injuries in pediatric patients with SCA. TBSS comparisons of a range of anisotropy and diffusion measures were carried out between age- and background-matched population groups: patients with SCA with no visible lesions, patients with SCA with mild gliosis, and normal controls. TBSS analysis revealed that both SCA populations exhibited reduced anisotropy and increased diffusivity compared with normal controls in multiple brain regions, including the corpus callosum and centrum semiovale. Furthermore, the results suggest that the severity of SCA is positively correlated with the white matter changes in the corpus callosum. The study demonstrates that TBSS is a viable technique in detecting subtle white matter damage in patients with SCA whose conventional anatomic MR imaging scans show no, or minimal, abnormalities and has the potential to evaluate the neurologic impact of the treatment of SCA.
- 24 February 2011
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 33 (3) , 510-526
Pediatric magnetic resonance urography
Magnetic resonance urography (MRU) is a powerful clinical tool that fuses anatomic information with functional data in a single test without the use of ionizing radiation. This article provides an overview of the technical aspects, as well as common clinical applications with an emphasis on the evaluation of hydronephrosis. A fluid challenge is an essential part of our MRU protocol and enables the definition of compensated or decompensated kidneys within the spectrum of hydronephrosis. This classification may have prognostic implications when surgery is being considered. In addition, underlying uropathy can be identified on the anatomical scans and renal scarring can be seen on both the anatomical and dynamic scans. MRU can identify and categorize dysmorphic kidneys in vivo and may provide insight into congenital abnormalities seen in conjunction with vesicoureteric reflux. MRU is still in its infancy and as the technique develops and becomes widely available, it seems likely that it will supplant renal scintigraphy in the evaluation of renal tract disorders in children. J. Magn. Reson. Imaging 2011;33:510–526.
- 24 February 2011
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 33 (3) , 510-526
Pediatric magnetic resonance urography
Magnetic resonance urography (MRU) is a powerful clinical tool that fuses anatomic information with functional data in a single test without the use of ionizing radiation. This article provides an overview of the technical aspects, as well as common clinical applications with an emphasis on the evaluation of hydronephrosis. A fluid challenge is an essential part of our MRU protocol and enables the definition of compensated or decompensated kidneys within the spectrum of hydronephrosis. This classification may have prognostic implications when surgery is being considered. In addition, underlying uropathy can be identified on the anatomical scans and renal scarring can be seen on both the anatomical and dynamic scans. MRU can identify and categorize dysmorphic kidneys in vivo and may provide insight into congenital abnormalities seen in conjunction with vesicoureteric reflux. MRU is still in its infancy and as the technique develops and becomes widely available, it seems likely that it will supplant renal scintigraphy in the evaluation of renal tract disorders in children. J. Magn. Reson. Imaging 2011;33:510–526.
- 11 December 2007
- Published by Springer Nature in Pediatric Radiology
- Vol. 38 (1) , 18-27
MRU post-processing
Dynamic magnetic resonance urography (MRU) scans acquired in conjunction with an injection of a contrast agent can be used to estimate a number of parameters that reflect renal function. This article discusses the methodologies and assumptions used in the estimation of these parameters, with special attention to the problem of deriving the concentration of the contrast agent from the change in the MR signal. The estimates of split renal function derived from MRU are in good agreement with those obtained using nuclear medicine studies. The time-intensity curves show subtle differences from those measured using nuclear medicine but still allow the transit of the contrast agent through the kidney to be assessed. Quantitative estimates of renal function (GFR) can be derived from MRU but have yet to be validated in a pediatric population.
- 11 December 2007
- Published by Springer Nature in Pediatric Radiology
- Vol. 38 (1) , 18-27
MRU post-processing
Dynamic magnetic resonance urography (MRU) scans acquired in conjunction with an injection of a contrast agent can be used to estimate a number of parameters that reflect renal function. This article discusses the methodologies and assumptions used in the estimation of these parameters, with special attention to the problem of deriving the concentration of the contrast agent from the change in the MR signal. The estimates of split renal function derived from MRU are in good agreement with those obtained using nuclear medicine studies. The time-intensity curves show subtle differences from those measured using nuclear medicine but still allow the transit of the contrast agent through the kidney to be assessed. Quantitative estimates of renal function (GFR) can be derived from MRU but have yet to be validated in a pediatric population.
- 1 December 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 185 (6) , 1598-1607
Dynamic Contrast-Enhanced MR Urography in the Evaluation of Pediatric Hydronephrosis: Part 1, Functional Assessment
OBJECTIVE. The purpose of our study was to derive time-intensity curves for the renal cortex and medulla from 3D dynamic MR urography and to assess whether these curves are predictive of obstruction.MATERIALS AND METHODS. Fifty-nine examinations were performed in 53 pediatric patients and the degree of obstruction assessed using the renal transit time. The cortex and medulla were segmented using a semiautomatic method, and mean time-intensity curves were derived for the segmented volumes. The basic parameters of the curves (amplitude, washout) were assessed, as was the presence of certain characteristic features of the curves.RESULTS. The images allowed clear visualization of three phases of the uptake of contrast material in the cortex, the medulla, and the collecting system. Both the amplitude of the curves and the washout of the contrast material were predictive of obstruction. The distal tubular peak was reliably detected in the cortex of nonobstructed kidneys.CONCLUSION. Combining signal-intensity-ve...
- 1 December 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 185 (6) , 1598-1607
Dynamic Contrast-Enhanced MR Urography in the Evaluation of Pediatric Hydronephrosis: Part 1, Functional Assessment
OBJECTIVE. The purpose of our study was to derive time-intensity curves for the renal cortex and medulla from 3D dynamic MR urography and to assess whether these curves are predictive of obstruction.MATERIALS AND METHODS. Fifty-nine examinations were performed in 53 pediatric patients and the degree of obstruction assessed using the renal transit time. The cortex and medulla were segmented using a semiautomatic method, and mean time-intensity curves were derived for the segmented volumes. The basic parameters of the curves (amplitude, washout) were assessed, as was the presence of certain characteristic features of the curves.RESULTS. The images allowed clear visualization of three phases of the uptake of contrast material in the cortex, the medulla, and the collecting system. Both the amplitude of the curves and the washout of the contrast material were predictive of obstruction. The distal tubular peak was reliably detected in the cortex of nonobstructed kidneys.CONCLUSION. Combining signal-intensity-ve...
- 1 October 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (1) , 41-50
Renal Transit Time with MR Urography in Children
To prospectively evaluate use of dynamic contrast material-enhanced magnetic resonance (MR) urography for measurement of renal transit time (RTT) of a contrast agent through the kidney and collecting system so as to identify obstructive uropathy in children. One hundred twenty-six children suspected of having hydronephrosis were hydrated prior to undergoing both conventional and dynamic contrast-enhanced MR urography of the kidneys and urinary tract. A three-dimensional sequence was used to track passage of contrast agent through the kidneys. Time between the appearance of contrast material in the kidney and its appearance in the ureter at or below the level of the lower pole of the kidney was defined as RTT. Bland-Altman plots were used to quantify intra- and interobserver performance. In 30 children, a nuclear medicine renogram was also obtained, and the half-life of renal signal decay after furosemide administration was derived and compared with the MR imaging RTT by using receiver operating characteristic curves. On the basis of RTT, kidneys were classified as normal (RTT RTT 490 seconds). Inter- and intraobserver agreement indicated that the technique is both robust and reproducible. Receiver operating characteristic analysis for comparison of results of MR imaging and diuretic renal scintigraphy showed good agreement between the modalities, with a mean area under the curve of 0.90. When used in conjunction with morphologic images obtained in the same examination, RTT generally allowed normal kidneys to be differentiated from obstructed and partially obstructed kidneys.
- 1 October 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 233 (1) , 41-50
Renal Transit Time with MR Urography in Children
To prospectively evaluate use of dynamic contrast material-enhanced magnetic resonance (MR) urography for measurement of renal transit time (RTT) of a contrast agent through the kidney and collecting system so as to identify obstructive uropathy in children. One hundred twenty-six children suspected of having hydronephrosis were hydrated prior to undergoing both conventional and dynamic contrast-enhanced MR urography of the kidneys and urinary tract. A three-dimensional sequence was used to track passage of contrast agent through the kidneys. Time between the appearance of contrast material in the kidney and its appearance in the ureter at or below the level of the lower pole of the kidney was defined as RTT. Bland-Altman plots were used to quantify intra- and interobserver performance. In 30 children, a nuclear medicine renogram was also obtained, and the half-life of renal signal decay after furosemide administration was derived and compared with the MR imaging RTT by using receiver operating characteristic curves. On the basis of RTT, kidneys were classified as normal (RTT RTT 490 seconds). Inter- and intraobserver agreement indicated that the technique is both robust and reproducible. Receiver operating characteristic analysis for comparison of results of MR imaging and diuretic renal scintigraphy showed good agreement between the modalities, with a mean area under the curve of 0.90. When used in conjunction with morphologic images obtained in the same examination, RTT generally allowed normal kidneys to be differentiated from obstructed and partially obstructed kidneys.
- 1 February 2004
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 182 (2) , 367-372
MRI of the Neonatal Brain: Optimization of Spin-Echo Parameters
OBJECTIVE. Our aim was to measure the relaxation times of the neonatal brain and to use these to derive pulse sequence parameters that enhance the signal-to-noise ratio (SNR) and contrast of MRI scans of the neonatal brain.SUBJECTS AND METHODS. The transverse (T2) and longitudinal (T1) relaxation times were measured for 10 healthy neonates, and the average relaxation times were calculated for both gray and white matter. Simulations using these values were then performed to estimate the optimal pulse sequence parameters. Images were obtained in three neonates using both the optimized and conventional sequence parameters.RESULTS. The measured (mean ± SD) relaxation times of the neonatal brain at 1.5 T were T1 equals 1,712 ± 235 msec and T2 equals 394 ± 52 msec in white matter and T1 equals 1,144 ± 245 msec and T2 equals 206 ± 26 msec in gray matter. The optimized T1-weighted imaging used a turbo spin-echo sequence with an echo-train length of 3 and TR/TE of 850/11 msec and showed increases in both the contr...
- 1 February 2004
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 182 (2) , 367-372
MRI of the Neonatal Brain: Optimization of Spin-Echo Parameters
OBJECTIVE. Our aim was to measure the relaxation times of the neonatal brain and to use these to derive pulse sequence parameters that enhance the signal-to-noise ratio (SNR) and contrast of MRI scans of the neonatal brain.SUBJECTS AND METHODS. The transverse (T2) and longitudinal (T1) relaxation times were measured for 10 healthy neonates, and the average relaxation times were calculated for both gray and white matter. Simulations using these values were then performed to estimate the optimal pulse sequence parameters. Images were obtained in three neonates using both the optimized and conventional sequence parameters.RESULTS. The measured (mean ± SD) relaxation times of the neonatal brain at 1.5 T were T1 equals 1,712 ± 235 msec and T2 equals 394 ± 52 msec in white matter and T1 equals 1,144 ± 245 msec and T2 equals 206 ± 26 msec in gray matter. The optimized T1-weighted imaging used a turbo spin-echo sequence with an echo-train length of 3 and TR/TE of 850/11 msec and showed increases in both the contr...