ABAnna C. Birely

Anna C. Birely

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anna C. Birely has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantitative Patina Rating Index for Weathering Steel Bridge Girders

    by Pushkar Shivechchhu, Seung Hyun Yoon, Zhen Zhang, Arash Rockey, Arash Noshadravan, Anna C. Birely, Matthew Yarnold, Stefan Hurlebaus

    Weathering steel is a low maintenance and cost-effective corrosion-resistant material that is widely used in bridge construction. The corrosion rate of weathering steel is known to be lower than carbon steel in a low- and medium-corrosive environment. This is because of the inherent corrosion resistance of the patina layer, which adheres to the substrate and protects the weathering steel from further corrosion. There are multiple guidelines to evaluate the protective performance of the rust layer that mainly emphasize visual inspection of the color and texture of the patina. However, these standards are, in general, qualitative and subject to observer bias. The tape adhesion test is one of the examinations proposed in the past that is less subjective, and it can be used to assess the functionality of patina to ensure the layer protects the underlying steel. The interpretation of the test results still relies on a partially qualitative judgment rather than a limited quantitative analysis. The objective of this research is to develop a reliable framework that can be used alongside visual inspections to increase accuracy in measurements. A Quantitative Patina Rating Index has been introduced in this paper, which was built on image analysis of 444 tape adhesion test samples, obtained from various macro and micro environmental conditions. The rating accounts for the size and the areal density of rust particles recorded on the tape samples and classifies patina in different categories. This classification will aid bridge owners and stakeholders in making more informed maintenance and inspection decisions.


  • Open Access

    Phase transformations of aged patina formed on weathering steel bridge girders

    by Pushkar Shivechchhu, Arash Rockey, Seung Hyun Yoon, Zhen Zhang, Arash Noshadravan, Anna C. Birely, Matthew Yarnold, Stefan Hurlebaus


  • Data-driven atmospheric corrosion risk mapping in Texas bridge superstructure

    by Zhen Zhang, Pushkar Shivechchhu, Seung Hyun Yoon, Arash Rockey, Arash Noshadravan, Anna C. Birely, Matthew Yarnold, Stefan Hurlebaus


  • Evaluation of Link Slab Performance on Texas Highway Bridges

    by Andrew N. Pearson, Anna C. Birely, Matthew Yarnold, Stefan Hurlebaus

    Multispan bridges with simply-supported girders are straightforward to construct and economical but have historically utilized expansion joints between the spans. The negative long-term impacts of expansion joints are well-documented in the literature: eventual leaking causes damage to the girder ends and substructures. To avoid this deterioration associated with the use of expansion joints, link slabs may be used instead. This paper presents the results of a study examining the performance of existing link slabs on Texas bridges. Although these link slab details have been used for over four decades in Texas, their performance had not been widely studied. To understand the performance of these details, the design characteristics and damage conditions of 468 Texas bridges were recorded using as-built drawings and inspection reports. A damage rating was developed to evaluate the performance of the link slabs on each bridge. Using this information, an analysis was conducted to determine how different bridge design characteristics correlate with the performance of link slabs. The results showed that attributes such as continuous deck length and mean span length correlated with link slab performance. Certain loading characteristics such as average daily traffic, average daily truck traffic, link slab rotational demand, and the ratio of link slab moment capacity to -demand were found to have an age-dependent correlation with link slab performance. The performance of different deck detail types and skewed decks was also investigated.


  • Load balancing external post-tensioning for strengthening existing inverted-T bent caps

    by Sun-Hee Park, Jilong Cui, John B. Mander, Tevfik Terzioglu, Anna C. Birely, Stefan Hurlebaus


  • Experimental Behavior of Reinforced Concrete and Pretensioned Concrete Bent Caps

    by Anna C. Birely, Kevin J. Yole, Ju Dong Lee, Codi D. McKee, John B. Mander

    Accelerated bridge construction using precast bridge substructures can enable reduction of traffic disruption, increased worker safety, and increased quality through controlled conditions at the time of fabrication. A largely unrealized benefit of precast substructures is the use of pretensioned bent caps that can provide superior performance to that of reinforced concrete bent caps. Full-scale experimental tests of reinforced concrete (RC) and pretensioned, prestressed concrete (PSC) bent cap subassemblies were conducted to verify the improved performance of pretensioned caps. Flexural reinforcing bars and strands were distributed along the sides of the bent cap to accommodate a pocket connection designed to provide large construction tolerances. Results showed superior performance of the pretensioned cap, including delayed initial cracking, smaller average flexure crack widths, and absence of shear cracking. Removal of live loads resulted in full closure of cracks, validating the design philosophy of zero tension under dead load.


  • Experimental Behavior of Pretensioned Bent Caps with Internal Voids for Weight Reduction

    by Codi D. McKee, Ju Dong Lee, Anna C. Birely, John B. Mander

    Precast bent caps offer the opportunity to reduce onsite labor and materials and to accelerate the speed of construction. For many bridges, the weight is manageable for shipping and placement without the need for large cranes. For large bent caps, the weight can become a significant challenge for construction. Internal voids can be effective in reducing the weight but introduce the potential for the formation of shear cracks at service loads, because the shear width is smaller than in a solid bent cap. Internal voids are an attractive option when bent caps are pretensioned, because pretensioning delays the formation of cracks. This paper presents the results of a full-scale experimental test program that investigated the progression of damage and the failure mechanisms of pretensioned bent caps with internal voids. Test specimens were subassemblies of a portion of a multicolumn bent that included an overhang, a negative bending region at the connection to a column, and a positive bending region. The variables investigated were the presence of a void, the amount of prestressing, and the void termination location. Results indicated that voided caps had similar flexural behavior to solid caps, but were more prone to shear cracking and had more brittle failures. The use of a higher prestressing force was found to significantly delay flexural cracking but to have a minor effect on delaying the formation of shear cracks. The location of void termination adjacent to the connection region influenced the extent of the damage at failure.


  • Recommendations for Design of Concentrically Pretensioned, Precast Concrete Bent Caps

    by Ju Dong Lee, Usha R. Barooah, Codi D. McKee, Anna C. Birely, John B. Mander

    Precast, prestressed bent caps are an attractive design option because they permit accelerated bridge construction and can extend the service life of bridges by reducing or eliminating the service-level cracking observed in RC bent caps. A design procedure is recommended for the flexural design of pretensioned bent caps in which the amount of prestressing is selected to ensure zero tension at service, with service- and strength-limit states serving as checks on the design. Recommendations include how to account for openings for connections that may influence the bent cap performance. Using the recommended flexural design procedure and AASHTO shear design provisions, pretensioned bent caps were designed for a suite of multicolumn bridges. The flexural design procedure is shown to be efficient for the design of most bridges, and many bent caps are expected to have only minor cracking, if any, at ultimate demands. The minimum area of transverse reinforcement was found to govern most bridge designs, leading to recommendations to use the general, noniterative sectional shear design method. The resulting designs lead to recommendations for how designers and contractors can use precast, pretensioned bent caps not only to enable accelerated construction and extend bridge service life but also to increase design and construction efficiency.


  • Experimental Performance of Steel Fiber Reinforced Concrete Bridge Deck

    by Joshua A. McMahon, Anna C. Birely

    A full-scale steel fiber reinforced concrete (SFRC) bridge deck was tested to investigate the behavior under two-way action. The deck was designed to reduce the amount of traditional reinforcing bars in a design controlled by service-limit criteria. The SFRC is intended to reduce the strains in the steel at service limits. Loads were applied to simulate the single and tandem loads in the continuous spans of the bridge deck and a single tandem load in the overhang. A companion test program tested slab strips to establish the one-way flexural response with and without reinforcing bars. One-way strength was used in a yield-line analysis to predict the experimental capacity of the specimens. Theoretical capacities were significantly less than the experimental strength for interior loads where significant multiple-cracking effects were observed from the SFRC. In the overhang where membrane action and load redistribution were not possible, yield-line analysis predicted the experimental capacity.