Takanao Mine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takanao Mine has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Tohru Masuyama
Cardiovascular Division, Department of Internal Medicine, Hyogo College of Medicine
11 shared publicationsTakeshi Kodani
Cardiovascular Division, Department of Internal Medicine, Hyogo College of Medicine, Nishinomiya, Japan
7 shared publicationsHideyuki Kishima
Department of Cardiovascular and Renal Medicine, Hyogo College of Medicine, Nishinomiya, Japan
6 shared publications- Hideyuki Kishima
Department of Cardiovascular and Renal Medicine Hyogo College of Medicine Nishinomiya Japan
6 shared publications Hiroji Miyake
Nishinomiya Kyoritsu Neurosurg Hosp, Dept Neurosurg Div, Nishinomiya, Hyogo, Japan
3 shared publicationsMamoru Hamaoka
Department of Internal Medicine, Cardiovascular Division, Hyogo College of Medicine, 1-1 Mukogawa-cho, Nishinomiya Hyogo 663-8501, Japan
3 shared publications
Latest Publications
- 1 March 2021
- Published by Springer Nature in Heart and Vessels
- Vol. 36 (3) , 393-400
Predictors for reduced flow velocity in left atrial appendage during sinus rhythm in patients with atrial fibrillation
Discontinuation of anticoagulation therapy after catheter ablation (CA) for atrial fibrillation (AF) remains controversial. While decreased left atrial appendage flow velocity (LAAFV) during AF leads to left atrial appendage thrombus and embolic events, some AF patients show decreased LAAFV even during sinus rhythm (SR). We studied 392 patients (256 males, 68 +/- 10 years) who exhibited SR during transesophageal echocardiography (TEE) before CA for AF. Clinical factors, transthoracic echocardiography, and blood samples were obtained before TEE. Reduced LAAFV was defined as < 35 cm/s of LAAFV. Reduced LAAFV was observed in 72/392 patients (18%). Reduced LAAFV was significantly associated with high prevalence of non-paroxysmal AF, elevated brain natriuretic peptide (BNP), prior heart failure, high CHADS(2)score, high CHA(2)DS(2)-VASc score, no beta blocker administration, increased left atrial volume index (LAVI), elevated E/eMODIFIER LETTER PRIME ratio, reduced left ventricular ejection fraction and high prevalence of left ventricular hypertrophy. On multivariate analysis, BNP (P = 0.0005, OR 1.045 for each 10 pg/ml increase in BNP, 95% CI 1.018-1.073) and LAVI (P = 0.0045, OR 1.044 for each 1 increase in LAVI, 95% CI 1.013-1.077) were associated with decreased LAAFV. The elevated BNP levels and large LAVI predict decreased LAAFV during SR in patients with AF.
- 1 March 2021
- Published by Springer Nature in Heart and Vessels
- Vol. 36 (3) , 393-400
Predictors for reduced flow velocity in left atrial appendage during sinus rhythm in patients with atrial fibrillation
Discontinuation of anticoagulation therapy after catheter ablation (CA) for atrial fibrillation (AF) remains controversial. While decreased left atrial appendage flow velocity (LAAFV) during AF leads to left atrial appendage thrombus and embolic events, some AF patients show decreased LAAFV even during sinus rhythm (SR). We studied 392 patients (256 males, 68 +/- 10 years) who exhibited SR during transesophageal echocardiography (TEE) before CA for AF. Clinical factors, transthoracic echocardiography, and blood samples were obtained before TEE. Reduced LAAFV was defined as < 35 cm/s of LAAFV. Reduced LAAFV was observed in 72/392 patients (18%). Reduced LAAFV was significantly associated with high prevalence of non-paroxysmal AF, elevated brain natriuretic peptide (BNP), prior heart failure, high CHADS(2)score, high CHA(2)DS(2)-VASc score, no beta blocker administration, increased left atrial volume index (LAVI), elevated E/eMODIFIER LETTER PRIME ratio, reduced left ventricular ejection fraction and high prevalence of left ventricular hypertrophy. On multivariate analysis, BNP (P = 0.0005, OR 1.045 for each 10 pg/ml increase in BNP, 95% CI 1.018-1.073) and LAVI (P = 0.0045, OR 1.044 for each 1 increase in LAVI, 95% CI 1.013-1.077) were associated with decreased LAAFV. The elevated BNP levels and large LAVI predict decreased LAAFV during SR in patients with AF.
- Open Access
- 12 November 2020
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 4 (6) , 1-5
Aortic dissection during transoesophageal echocardiography: a case report
Transoesophageal echocardiography (TOE) is a safe and useful tool. In our case, we are presenting a rare case of a patient with aortic dissection during TOE procedure. A 79-year-old woman was referred to our hospital for recurrent paroxysmal atrial fibrillation (AF) with palpitation. Pre-procedural cardiac computed tomography (CT) showed slight dilated ascending aorta (maximum diameter: 40 mm). We decided to perform catheter ablation (CA) for AF, and recommended TOE before the CA because she had a CHADS2 score of 4. On the day before the CA, TOE was performed. Her physical examinations at the time of TOE procedure were unremarkable. At 3 min after probe insertion, there was no abnormal finding of the ascending aorta. At 5 min after the insertion, TOE showed ascending aortic dissection without pericardial effusion. After waking, she had severe back pain and underwent a contrast-enhanced CT. Computed tomography demonstrated Stanford type A aortic dissection extending from the aortic root to the bifurcation of common iliac arteries, and tight stenosis in the right coronary artery (maximum diameter; 49 mm). The patient underwent a replacement of the ascending aorta, and a coronary artery bypass graft surgery for the right coronary artery. Transoesophageal echocardiography would have to be performed under sufficient sedation with continuous blood pressure monitoring in patients who have risk factors of aortic dissection. The risk–benefit of TOE must be considered before a decision is made. Depending on the situation, another modality instead of TOE might be required.
- 12 November 2020
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 4 (6) , 1-5
Open AccessAortic dissection during transoesophageal echocardiography: a case report
Transoesophageal echocardiography (TOE) is a safe and useful tool. In our case, we are presenting a rare case of a patient with aortic dissection during TOE procedure. A 79-year-old woman was referred to our hospital for recurrent paroxysmal atrial fibrillation (AF) with palpitation. Pre-procedural cardiac computed tomography (CT) showed slight dilated ascending aorta (maximum diameter: 40 mm). We decided to perform catheter ablation (CA) for AF, and recommended TOE before the CA because she had a CHADS2 score of 4. On the day before the CA, TOE was performed. Her physical examinations at the time of TOE procedure were unremarkable. At 3 min after probe insertion, there was no abnormal finding of the ascending aorta. At 5 min after the insertion, TOE showed ascending aortic dissection without pericardial effusion. After waking, she had severe back pain and underwent a contrast-enhanced CT. Computed tomography demonstrated Stanford type A aortic dissection extending from the aortic root to the bifurcation of common iliac arteries, and tight stenosis in the right coronary artery (maximum diameter; 49 mm). The patient underwent a replacement of the ascending aorta, and a coronary artery bypass graft surgery for the right coronary artery. Transoesophageal echocardiography would have to be performed under sufficient sedation with continuous blood pressure monitoring in patients who have risk factors of aortic dissection. The risk–benefit of TOE must be considered before a decision is made. Depending on the situation, another modality instead of TOE might be required.
- 1 September 2020
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 79, 7-11
Plasma brain natriuretic peptide level on admission predicts long-term outcome in patients with non-traumatic subarachnoid hemorrhage
- 1 September 2020
- Published by Elsevier in Journal of Clinical Neuroscience
- Vol. 79, 7-11
Plasma brain natriuretic peptide level on admission predicts long-term outcome in patients with non-traumatic subarachnoid hemorrhage
- 25 December 2019
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 84 (1) , 26-32
Left Ventricular Inflow Velocity Pattern in Patients With Symptomatic Premature Ventricular Contraction
Background:Because premature ventricular contractions (PVCs) are one of the most common arrhythmias, but with unclear causative mechanisms, we studied the hemodynamic features that can cause symptomatic PVCs.Methods and Results:We studied 109 patients (48 males, age 60±19 years) with frequent monomorphic PVCs and no structural heart disease. The left ventricular inflow diastolic filling velocity was recorded by transthoracic echocardiography (TTE) at the time of PVCs in all patients. We assessed the PVC E wave flow (E wave velocity×duration at PVC). A total of 38 patients (35%) had PVC-related symptoms (19 palpitations, 12 pulse deficit, 6 shortness of breath, 6 malaise, 1 syncope). These patients showed reduced PVC E wave flow (9.3±6.0 vs. 14.6±6.5 cm, P<0.0001), and reduced PVC stroke volume (20.5±10.8 vs. 29.9±17.2 mL, P=0.0030). In the multivariate analysis, only reduced PVC E wave flow was independently associated with PVC-related symptoms (P=0.00349, odds ratio: 1.134029, each 1.0 cm increase in PVC E wave flow, 95% confidence interval: 1.040726–1.247544).Conclusions:Decreased E wave flow at the time of PVC was independently related with PVC-related symptoms in patients with PVCs. The LV contraction at the time of inadequate filling might be a cause of PVC-related symptoms.
- 25 December 2019
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 84 (1) , 26-32
Left Ventricular Inflow Velocity Pattern in Patients With Symptomatic Premature Ventricular Contraction
Background:Because premature ventricular contractions (PVCs) are one of the most common arrhythmias, but with unclear causative mechanisms, we studied the hemodynamic features that can cause symptomatic PVCs.Methods and Results:We studied 109 patients (48 males, age 60±19 years) with frequent monomorphic PVCs and no structural heart disease. The left ventricular inflow diastolic filling velocity was recorded by transthoracic echocardiography (TTE) at the time of PVCs in all patients. We assessed the PVC E wave flow (E wave velocity×duration at PVC). A total of 38 patients (35%) had PVC-related symptoms (19 palpitations, 12 pulse deficit, 6 shortness of breath, 6 malaise, 1 syncope). These patients showed reduced PVC E wave flow (9.3±6.0 vs. 14.6±6.5 cm, P<0.0001), and reduced PVC stroke volume (20.5±10.8 vs. 29.9±17.2 mL, P=0.0030). In the multivariate analysis, only reduced PVC E wave flow was independently associated with PVC-related symptoms (P=0.00349, odds ratio: 1.134029, each 1.0 cm increase in PVC E wave flow, 95% confidence interval: 1.040726–1.247544).Conclusions:Decreased E wave flow at the time of PVC was independently related with PVC-related symptoms in patients with PVCs. The LV contraction at the time of inadequate filling might be a cause of PVC-related symptoms.
- Open Access
- 19 October 2016
- Published by Wiley in Case Reports in Cardiology
- Vol. 2016, 1-3
An Endomyocardial Biopsy of the Left Ventricle in an Anorexia Nervosa Patient with Sinus Bradycardia and Left Ventricular Systolic Dysfunction
Anorexia nervosa (AN) is an eating disorder characterized by an abnormally low body weight, an intense fear of gaining weight, and a distorted perception of body weight. AN is a life-threatening condition that significantly increases the risk of death due to cardiac complications, such that at least one-third of all deaths in patients with AN are associated with cardiac causes including sudden death. In many reports, sudden death has been linked to reduced left ventricular function, structural changes, and QT abnormalities. However, the mechanistic details connecting AN to cardiac abnormalities remain unknown. Here we present an endomyocardial biopsy of the left ventricle in a case of AN with a reversible left ventricular systolic dysfunction.
- 19 October 2016
- Published by Wiley in Case Reports in Cardiology
- Vol. 2016, 1-3
Open AccessAn Endomyocardial Biopsy of the Left Ventricle in an Anorexia Nervosa Patient with Sinus Bradycardia and Left Ventricular Systolic Dysfunction
Anorexia nervosa (AN) is an eating disorder characterized by an abnormally low body weight, an intense fear of gaining weight, and a distorted perception of body weight. AN is a life-threatening condition that significantly increases the risk of death due to cardiac complications, such that at least one-third of all deaths in patients with AN are associated with cardiac causes including sudden death. In many reports, sudden death has been linked to reduced left ventricular function, structural changes, and QT abnormalities. However, the mechanistic details connecting AN to cardiac abnormalities remain unknown. Here we present an endomyocardial biopsy of the left ventricle in a case of AN with a reversible left ventricular systolic dysfunction.
- 12 August 2016
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 39 (9) , 999-1005
The Effects of Shock from Defibrillation Threshold Testing on Cardiac Systolic and Diastolic Function
Background: Inappropriate implantable cardioverter defibrillator (ICD) shocks are associated with increased overall mortality. However, it remains unclear whether shocks from defibrillation threshold (DFT) testing directly impair cardiac function.Methods: DFT testing was performed in 34 patients who underwent ICD/cardiac resynchronization therapy with a defibrillator implantation/generator exchange. Heart rate and cardiac function, including left ventricular (LV) systolic pressure, LV end‐diastolic pressure, peak positive and negative dp/dt ( + dp/dt and –dp/dt, respectively) of LV pressure, and the tau index, were assessed with a Mikro‐Cath™ diagnostic pressure catheter (CD Leycom, Zoetermeer, the Netherlands). These parameters were measured before and 1 minute, 3 minutes, 5 minutes, 10 minutes, and 15 minutes after DFT testing.Results: Peak positive dp/dt increased over baseline at each interval (976 ± 229 mm Hg/s vs 1,039 ± 258, 1,049 ± 245, 1,042 ± 247, 1,037 ± 259, and 1,034 ± 254 mm Hg/s, respectively; P < 0.01). Furthermore, peak negative dp/dt (–1,140 ± 397 mm Hg/s vs –1,185 ± 447, 1,193 ± 435, –1,195 ± 434, –1,189 ± 449, and –1,186 ± 459 mm Hg/s, respectively; P < 0.01) and the tau index (65.1 ± 18.5 vs 62.5 ± 16.8*, 62.4 ± 15.9**, 63.0 ± 16.8*, and 62.8 ± 18.7*, respectively; *P < 0.05,**P < 0.01) decreased compared to those at baseline at each interval.Conclusion: Shock after DFT testing improved LV systolic and diastolic function immediately, especially in patients with preserved LV ejection fraction.
- 12 August 2016
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 39 (9) , 999-1005
The Effects of Shock from Defibrillation Threshold Testing on Cardiac Systolic and Diastolic Function
Background: Inappropriate implantable cardioverter defibrillator (ICD) shocks are associated with increased overall mortality. However, it remains unclear whether shocks from defibrillation threshold (DFT) testing directly impair cardiac function.Methods: DFT testing was performed in 34 patients who underwent ICD/cardiac resynchronization therapy with a defibrillator implantation/generator exchange. Heart rate and cardiac function, including left ventricular (LV) systolic pressure, LV end‐diastolic pressure, peak positive and negative dp/dt ( + dp/dt and –dp/dt, respectively) of LV pressure, and the tau index, were assessed with a Mikro‐Cath™ diagnostic pressure catheter (CD Leycom, Zoetermeer, the Netherlands). These parameters were measured before and 1 minute, 3 minutes, 5 minutes, 10 minutes, and 15 minutes after DFT testing.Results: Peak positive dp/dt increased over baseline at each interval (976 ± 229 mm Hg/s vs 1,039 ± 258, 1,049 ± 245, 1,042 ± 247, 1,037 ± 259, and 1,034 ± 254 mm Hg/s, respectively; P < 0.01). Furthermore, peak negative dp/dt (–1,140 ± 397 mm Hg/s vs –1,185 ± 447, 1,193 ± 435, –1,195 ± 434, –1,189 ± 449, and –1,186 ± 459 mm Hg/s, respectively; P < 0.01) and the tau index (65.1 ± 18.5 vs 62.5 ± 16.8*, 62.4 ± 15.9**, 63.0 ± 16.8*, and 62.8 ± 18.7*, respectively; *P < 0.05,**P < 0.01) decreased compared to those at baseline at each interval.Conclusion: Shock after DFT testing improved LV systolic and diastolic function immediately, especially in patients with preserved LV ejection fraction.
- Open Access
- 17 July 2015
- Published by Wiley in Journal of Arrhythmia
- Vol. 31 (6) , 371-375
Hemodynamic effects of Purkinje potential pacing in the left ventricular endocardium in patients with advanced heart failure
Background: Various difficulties can occur in patients who undergo cardiac resynchronization therapy for drug‐refractory heart failure with respect to placement of the left ventricular (LV) lead, because of anatomical features, pacing thresholds, twitching, or pacing lead anchoring, possibly requiring other pacing sites. The goal of this study was to determine whether Purkinje potential (PP) pacing could provide better hemodynamics in patients with left bundle branch block and heart failure than biventricular (BiV) pacing.Methods: Eleven patients with New York Heart Association functional class II or III heart failure despite optimal medical therapy were selected for this study. All patients underwent left‐ and right‐sided cardiac catheterization for measurement of LV functional parameters in the control state during BiV and PP pacing.Results: Maximum dP/dt increased during BiV and PP pacing when compared with control measurements. This study compared parameters measured during BiV pacing with PP pacing and non‐paced beats as the control state in each patient (717±171 mmHg/s vs. 917±191 mmHg/s, ppP/dt, left ventricular end‐diastolic pressure, left ventricular end‐systolic pressure, pulmonary capillary wedge pressure, or cardiac index when comparing BiV pacing and PP pacing to control measurements.Conclusions: The hemodynamic outcome of PP pacing was comparable to that of BiV pacing in patients with advanced heart failure.
- 17 July 2015
- Published by Wiley in Journal of Arrhythmia
- Vol. 31 (6) , 371-375
Open AccessHemodynamic effects of Purkinje potential pacing in the left ventricular endocardium in patients with advanced heart failure
Background: Various difficulties can occur in patients who undergo cardiac resynchronization therapy for drug‐refractory heart failure with respect to placement of the left ventricular (LV) lead, because of anatomical features, pacing thresholds, twitching, or pacing lead anchoring, possibly requiring other pacing sites. The goal of this study was to determine whether Purkinje potential (PP) pacing could provide better hemodynamics in patients with left bundle branch block and heart failure than biventricular (BiV) pacing.Methods: Eleven patients with New York Heart Association functional class II or III heart failure despite optimal medical therapy were selected for this study. All patients underwent left‐ and right‐sided cardiac catheterization for measurement of LV functional parameters in the control state during BiV and PP pacing.Results: Maximum dP/dt increased during BiV and PP pacing when compared with control measurements. This study compared parameters measured during BiV pacing with PP pacing and non‐paced beats as the control state in each patient (717±171 mmHg/s vs. 917±191 mmHg/s, ppP/dt, left ventricular end‐diastolic pressure, left ventricular end‐systolic pressure, pulmonary capillary wedge pressure, or cardiac index when comparing BiV pacing and PP pacing to control measurements.Conclusions: The hemodynamic outcome of PP pacing was comparable to that of BiV pacing in patients with advanced heart failure.
- 22 January 2015
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 23 (5) , 530-534
Spontaneous subclavian venous occlusion before electronic device implantation
Subclavian venous occlusion sometimes precludes the ability to insert leads during placement of a cardiac implantable electronic device. This study was performed to identify the risk factors for spontaneous subclavian venous occlusion prior to placement of an implantable electronic device. We studied 446 patients who underwent axillary-subclavian venography to assess for occlusion and/or anomaly of the subclavian vein or associated veins before electronic device implantation. Six (1.3%) patients had venous occlusion (left subclavian vein in 5, left innominate vein in 1). There was a significantly higher incidence of previous cancer in the occlusion group than in the nonocclusion group (11.5% vs. 50%, p = 0.03). Subclavian venous occlusion may be present before cardiac implantable electronic device placement. A history of cancer represents a risk factor subclavian venous occlusion, and patients with this risk factor should undergo subclavian venography prior to electronic device placement.
- 22 January 2015
- Published by SAGE Publications in Asian Cardiovascular and Thoracic Annals
- Vol. 23 (5) , 530-534
Spontaneous subclavian venous occlusion before electronic device implantation
Subclavian venous occlusion sometimes precludes the ability to insert leads during placement of a cardiac implantable electronic device. This study was performed to identify the risk factors for spontaneous subclavian venous occlusion prior to placement of an implantable electronic device. We studied 446 patients who underwent axillary-subclavian venography to assess for occlusion and/or anomaly of the subclavian vein or associated veins before electronic device implantation. Six (1.3%) patients had venous occlusion (left subclavian vein in 5, left innominate vein in 1). There was a significantly higher incidence of previous cancer in the occlusion group than in the nonocclusion group (11.5% vs. 50%, p = 0.03). Subclavian venous occlusion may be present before cardiac implantable electronic device placement. A history of cancer represents a risk factor subclavian venous occlusion, and patients with this risk factor should undergo subclavian venography prior to electronic device placement.