Cedric Hurth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cedric Hurth has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
Frederic Zenhausern
6 shared publicationsJean-Pierre Aimé
Université Bordeaux1
4 shared publicationsJianing Yang
The University of Arizona College of Medicine
4 shared publicationsMatthew D. Estes
4 shared publicationsAbdelhamid Maali
Université Bordeaux1
3 shared publicationsCarla Brooks
The University of Arizona College of Medicine
3 shared publications
Latest Publications
- Open Access
- 14 December 2021
- Published by MDPI AG in Infectious Disease Reports
- Vol. 13 (4) , 1061-1077
A Sensitive, Portable Microfluidic Device for SARS-CoV-2 Detection from Self-Collected Saliva
Since the outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic in December 2019, the spread of SARS-CoV2 infection has been escalating rapidly around the world. In order to provide more timely access to medical intervention, including diagnostic tests and medical treatment, the FDA authorized multiple test protocols for diagnostic tests from nasopharyngeal swab, saliva, urine, bronchoalveolar lavage and fecal samples. The traditional diagnostic tests for this novel coronavirus 2019 require standard processes of viral RNA isolation, reverse transcription of RNA to cDNA, then real-time quantitative PCR with the RNA templates extracted from the patient samples. Recently, many reports have demonstrated a direct detection of SARS-Co-V2 genomic material from saliva samples without any RNA isolation step. To make the rapid detection of SARS-Co-V2 infection more accessible, a point-of-care type device was developed for SARS-CoV-2 detection. Herein, we report a portable microfluidic-based integrated detection-analysis system for SARS-CoV-2 nucleic acids detection directly from saliva samples. The saliva cartridge is self-contained and capable of microfluidic evaluation of saliva, from heating, mixing with the primers to multiplex real-time quantitative polymerase chain reaction, detecting SARS-CoV-2 with different primer sets and internal control. The approach has a detection sensitivity of 1000 copies/mL of SARS-CoV-2 RNA or virus, with consistency and automation, from saliva sample-in to result-out.
- 14 December 2021
- Published by MDPI AG in Infectious Disease Reports
- Vol. 13 (4) , 1061-1077
Open AccessA Sensitive, Portable Microfluidic Device for SARS-CoV-2 Detection from Self-Collected Saliva
Since the outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic in December 2019, the spread of SARS-CoV2 infection has been escalating rapidly around the world. In order to provide more timely access to medical intervention, including diagnostic tests and medical treatment, the FDA authorized multiple test protocols for diagnostic tests from nasopharyngeal swab, saliva, urine, bronchoalveolar lavage and fecal samples. The traditional diagnostic tests for this novel coronavirus 2019 require standard processes of viral RNA isolation, reverse transcription of RNA to cDNA, then real-time quantitative PCR with the RNA templates extracted from the patient samples. Recently, many reports have demonstrated a direct detection of SARS-Co-V2 genomic material from saliva samples without any RNA isolation step. To make the rapid detection of SARS-Co-V2 infection more accessible, a point-of-care type device was developed for SARS-CoV-2 detection. Herein, we report a portable microfluidic-based integrated detection-analysis system for SARS-CoV-2 nucleic acids detection directly from saliva samples. The saliva cartridge is self-contained and capable of microfluidic evaluation of saliva, from heating, mixing with the primers to multiplex real-time quantitative polymerase chain reaction, detecting SARS-CoV-2 with different primer sets and internal control. The approach has a detection sensitivity of 1000 copies/mL of SARS-CoV-2 RNA or virus, with consistency and automation, from saliva sample-in to result-out.
- 27 June 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (7) , 3698
Surface cytometer for fluorescent detection and growth monitoring of bacteria over a large field-of-view: publisher’s note
This publisher's note amends the author list of [Biomed. Opt. Express 10, 2101 (2019)].
- 27 June 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (7) , 3698
Surface cytometer for fluorescent detection and growth monitoring of bacteria over a large field-of-view: publisher’s note
This publisher's note amends the author list of [Biomed. Opt. Express 10, 2101 (2019)].
- 28 March 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (4) , 2101-2116
Surface cytometer for fluorescent detection and growth monitoring of bacteria over a large field-of-view
Monitoring the early onset of bacterial film formation is critical in many clinical, environmental, and food quality control applications. We built a small inexpensive optical surface cytometer, in contrast with bulk spectroscopic methods, around a light-emitting diode (LED) and a complementary metal-oxide-semiconductor (CMOS) image sensor. It is designed to offer a large field-of-view of 200 mm2 and a large depth-of-field of 2-3 mm to overcome the limitations of routine methods like spectrophotometry and fluorescence microscopy. It provides a direct measurement without the need for complex image post-processing with a limit-of-detection around 104 cells/mm2, which is competitive with other similar yet more complex devices already available.
- 28 March 2019
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 10 (4) , 2101-2116
Surface cytometer for fluorescent detection and growth monitoring of bacteria over a large field-of-view
Monitoring the early onset of bacterial film formation is critical in many clinical, environmental, and food quality control applications. We built a small inexpensive optical surface cytometer, in contrast with bulk spectroscopic methods, around a light-emitting diode (LED) and a complementary metal-oxide-semiconductor (CMOS) image sensor. It is designed to offer a large field-of-view of 200 mm2 and a large depth-of-field of 2-3 mm to overcome the limitations of routine methods like spectrophotometry and fluorescence microscopy. It provides a direct measurement without the need for complex image post-processing with a limit-of-detection around 104 cells/mm2, which is competitive with other similar yet more complex devices already available.
- Open Access
- 4 June 2018
- Published by MedDocs Publishers LLC in Journal of Nanomedicine
- Vol. 1 (2)
Influence of a single nucleotide polymorphism (SNP) and DNA hybridization on the drying patterns of micro droplets
- 4 June 2018
- Published by MedDocs Publishers LLC in Journal of Nanomedicine
- Vol. 1 (2)
Open AccessInfluence of a single nucleotide polymorphism (SNP) and DNA hybridization on the drying patterns of micro droplets
- 1 December 2015
- Published by Elsevier in Chemical Engineering Science
- Vol. 137, 398-403
Biomolecular interactions control the shape of stains from drying droplets of complex fluids
- 1 December 2015
- Published by Elsevier in Chemical Engineering Science
- Vol. 137, 398-403
Biomolecular interactions control the shape of stains from drying droplets of complex fluids
- Open Access
- 1 September 2015
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 5, 8-12
Real-time monitoring of viscosity changes triggered by chemical reactions using a high-speed imaging method
- 1 September 2015
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 5, 8-12
Open AccessReal-time monitoring of viscosity changes triggered by chemical reactions using a high-speed imaging method
- 9 August 2014
- Published by Springer Nature in Biomedical Microdevices
- Vol. 16 (6) , 905-914
A miniature quantitative PCR device for directly monitoring a sample processing on a microfluidic rapid DNA system
We report a microfluidic device and measurement method to perform real-time PCR (or qPCR) in a miniaturized configuration for on-chip implementation using reaction volumes of less than 20 μL. The qPCR bioreactor is designed as a module to be embedded in an automated sample-in/profile-out system for rapid DNA biometrics or human identification. The PCR mixture is excited with a 505 nm diode-pumped solid-state laser (DPSSL) and the fluorescence build-up is measured using optical fibers directly embedded to the sidewalls of the microfluidic qPCR bioreactor. We discuss manufacturing and operating parameters necessary to adjust the internal surface conditions and temperature profiles of the bioreactor and to optimize the yield and quality of the PCR reaction for the amplification of 62 bp hTERT intron fragments using the commercial Quantifiler® kit (Life Technologies, Carlsbad, CA) commonly accepted for genotyping analysis. We designed a microfluidic device suitable for continuously processing a specimen by efficiently mixing the reagents from the kit to a set volume of DNA template on chip. Our approach relies on a calibration curve for the specific device using control DNA. We successfully applied this method to determine the concentration of genomic DNA extracted from a buccal swab on separate microfluidic devices which are operated upstream the qPCR device and perform buccal swab lysis and buccal DNA extraction. A precise correlation between the amount determined on chip and that obtained using a commercial cycler is demonstrated.
- 9 August 2014
- Published by Springer Nature in Biomedical Microdevices
- Vol. 16 (6) , 905-914
A miniature quantitative PCR device for directly monitoring a sample processing on a microfluidic rapid DNA system
We report a microfluidic device and measurement method to perform real-time PCR (or qPCR) in a miniaturized configuration for on-chip implementation using reaction volumes of less than 20 μL. The qPCR bioreactor is designed as a module to be embedded in an automated sample-in/profile-out system for rapid DNA biometrics or human identification. The PCR mixture is excited with a 505 nm diode-pumped solid-state laser (DPSSL) and the fluorescence build-up is measured using optical fibers directly embedded to the sidewalls of the microfluidic qPCR bioreactor. We discuss manufacturing and operating parameters necessary to adjust the internal surface conditions and temperature profiles of the bioreactor and to optimize the yield and quality of the PCR reaction for the amplification of 62 bp hTERT intron fragments using the commercial Quantifiler® kit (Life Technologies, Carlsbad, CA) commonly accepted for genotyping analysis. We designed a microfluidic device suitable for continuously processing a specimen by efficiently mixing the reagents from the kit to a set volume of DNA template on chip. Our approach relies on a calibration curve for the specific device using control DNA. We successfully applied this method to determine the concentration of genomic DNA extracted from a buccal swab on separate microfluidic devices which are operated upstream the qPCR device and perform buccal swab lysis and buccal DNA extraction. A precise correlation between the amount determined on chip and that obtained using a commercial cycler is demonstrated.
- 1 January 2014
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 8 (1) , 147-158
An integratable microfluidic cartridge for forensic swab samples lysis
- 1 January 2014
- Published by Elsevier in Forensic Science International: Genetics
- Vol. 8 (1) , 147-158
An integratable microfluidic cartridge for forensic swab samples lysis
- 26 December 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 114 (24) , 244701
Automation of a high-speed imaging setup for differential viscosity measurements
We present the automation of a setup previously used to assess the viscosity of pleural effusion samples and discriminate between transudates and exudates, an important first step in clinical diagnostics. The presented automation includes the design, testing, and characterization of a vacuum-actuated loading station that handles the 2 mm glass spheres used as sensors, as well as the engineering of electronic Printed Circuit Board (PCB) incorporating a microcontroller and their synchronization with a commercial high-speed camera operating at 10 000 fps. The hereby work therefore focuses on the instrumentation-related automation efforts as the general method and clinical application have been reported earlier [Hurth et al., J. Appl. Phys. 110, 034701 (2011)]. In addition, we validate the performance of the automated setup with the calibration for viscosity measurements using water/glycerol standard solutions and the determination of the viscosity of an “unknown” solution of hydroxyethyl cellulose.
- 26 December 2013
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 114 (24) , 244701
Automation of a high-speed imaging setup for differential viscosity measurements
We present the automation of a setup previously used to assess the viscosity of pleural effusion samples and discriminate between transudates and exudates, an important first step in clinical diagnostics. The presented automation includes the design, testing, and characterization of a vacuum-actuated loading station that handles the 2 mm glass spheres used as sensors, as well as the engineering of electronic Printed Circuit Board (PCB) incorporating a microcontroller and their synchronization with a commercial high-speed camera operating at 10 000 fps. The hereby work therefore focuses on the instrumentation-related automation efforts as the general method and clinical application have been reported earlier [Hurth et al., J. Appl. Phys. 110, 034701 (2011)]. In addition, we validate the performance of the automated setup with the calibration for viscosity measurements using water/glycerol standard solutions and the determination of the viscosity of an “unknown” solution of hydroxyethyl cellulose.
- 16 April 2013
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 15 (31) , 12805-12814
A tuneable array of unique steady-state microfluidic gradients
We report an on-chip gradient generator that has been designed, modelled, fabricated, and characterized to facilitate temporal tuning of several unique gradients in parallel for multiple applications. This design allows for steady state programming of the intensities across multiple orders of magnitude while producing exponential, linear, and logarithmic gradient profiles. The magnitude of the gradients is controlled through regulating the ratio of the two on-chip flow inlets without the need for valves or other active mixers. On-chip binding of biotin by a fluorescent streptavidin complex creates a diffusive barrier that regulates access to the gradient inlets, providing a second orthogonal mechanism for regulating the microgradient intensities. The device is also characterized using an on-chip enzymatic reaction to produce an array of tuneable product concentrations within the various microchannels.
- 16 April 2013
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 15 (31) , 12805-12814
A tuneable array of unique steady-state microfluidic gradients
We report an on-chip gradient generator that has been designed, modelled, fabricated, and characterized to facilitate temporal tuning of several unique gradients in parallel for multiple applications. This design allows for steady state programming of the intensities across multiple orders of magnitude while producing exponential, linear, and logarithmic gradient profiles. The magnitude of the gradients is controlled through regulating the ratio of the two on-chip flow inlets without the need for valves or other active mixers. On-chip binding of biotin by a fluorescent streptavidin complex creates a diffusive barrier that regulates access to the gradient inlets, providing a second orthogonal mechanism for regulating the microgradient intensities. The device is also characterized using an on-chip enzymatic reaction to produce an array of tuneable product concentrations within the various microchannels.