Austin Fleming
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Austin Fleming has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Colby Jensen
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
9 shared publications Heng Ban
6 shared publications- Charles Pearson Folsom
Idaho National Laboratory
5 shared publications Mihai Chirtoc
GRESPI, Multiscale Thermophysics Lab., Université de Reims Champagne-Ardenne URCA, Reims, France
4 shared publications- Daniel Devon Imholte
Idaho National Laboratory
3 shared publications - Kevin Tsai
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
3 shared publications
Latest Publications
- 30 September 2026
- Published by Office of Scientific and Technical Information (OSTI)
Fiber-optic-based Acoustic Emission Sensor for Irradiation Experiments
Timing of acoustic signatures can provide valuable information to key parameters in transient testing of nuclear fuels. Particularly, detecting cladding failure in reactivity initiated accident and loss of coolant accident testing provides useful information for fuel pin limits under accident scenarios. Additionally, characterizing the timing of other events such onset and departure from nucleate boiling is useful for understanding the fuel system performance. Current means of detecting acoustic phenomena inside of an irradiation capsule is through piezo electric transducers which are geometrically cylinders with 0.75 inch in diameter and 0.75 inch in height. Using this size of a sensor inside of an irradiation capsule greatly reduces the locations in which it can be placed, which ultimately limits the phenomena in which these sensors can detect. Optical fiber provides a more minimally invasive alternative to this sensing problem. Here, a fiber optic based acoustic emission sensor is developed, based upon a commercially developed vibrometry system. An optical probe designed to incorporate these sensors into an irradiation capsule is developed and tested considering the needs of the interrogation system and the environmental effects of irradiation testing. A mechanical assembly acting as the vibrating target needed to respond to acoustic emission is also developed and tested in a proof-of-concept design of the sensor.
- 30 September 2026
- Published by Office of Scientific and Technical Information (OSTI)
Fiber-optic-based Acoustic Emission Sensor for Irradiation Experiments
Timing of acoustic signatures can provide valuable information to key parameters in transient testing of nuclear fuels. Particularly, detecting cladding failure in reactivity initiated accident and loss of coolant accident testing provides useful information for fuel pin limits under accident scenarios. Additionally, characterizing the timing of other events such onset and departure from nucleate boiling is useful for understanding the fuel system performance. Current means of detecting acoustic phenomena inside of an irradiation capsule is through piezo electric transducers which are geometrically cylinders with 0.75 inch in diameter and 0.75 inch in height. Using this size of a sensor inside of an irradiation capsule greatly reduces the locations in which it can be placed, which ultimately limits the phenomena in which these sensors can detect. Optical fiber provides a more minimally invasive alternative to this sensing problem. Here, a fiber optic based acoustic emission sensor is developed, based upon a commercially developed vibrometry system. An optical probe designed to incorporate these sensors into an irradiation capsule is developed and tested considering the needs of the interrogation system and the environmental effects of irradiation testing. A mechanical assembly acting as the vibrating target needed to respond to acoustic emission is also developed and tested in a proof-of-concept design of the sensor.
- Open Access
- 19 May 2026
- Published by Elsevier in SSRN Electronic Journal
Systematic sensitivity on local fin effect of thermocouple mounted on the heated surface during rapid power transients
Surface-mounted thermocouples (TCs) are the most common method to monitor cladding surface temperatures during reactivity-initiated accident (RIA) experiments. However, the accuracy of these measurements is impacted by the local fin effect, where heat conduction through TC wires distorts temperature readings, particularly under transient conditions like rapid boiling. This effect can lead to significant underestimations of actual cladding temperatures, with discrepancies exceeding 100 K. To address these challenges, this paper uses finite element method (FEM) techniques to model heat transfer in cladding and TCs for two RIA tests, verifying results against experimental data. The computational model predicts lower temperatures near TCs, especially during the film boiling regime, highlighting the local fin effect. Sensitivity analyses are followed to identify key parameters affecting the local fin effect revealing TC wire diameter has the most significant influence. A correlation is developed from the sensitivity analysis results to estimate accurate cladding temperatures, demonstrating the potential of adjustment method using computational models.
- 19 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSystematic sensitivity on local fin effect of thermocouple mounted on the heated surface during rapid power transients
Surface-mounted thermocouples (TCs) are the most common method to monitor cladding surface temperatures during reactivity-initiated accident (RIA) experiments. However, the accuracy of these measurements is impacted by the local fin effect, where heat conduction through TC wires distorts temperature readings, particularly under transient conditions like rapid boiling. This effect can lead to significant underestimations of actual cladding temperatures, with discrepancies exceeding 100 K. To address these challenges, this paper uses finite element method (FEM) techniques to model heat transfer in cladding and TCs for two RIA tests, verifying results against experimental data. The computational model predicts lower temperatures near TCs, especially during the film boiling regime, highlighting the local fin effect. Sensitivity analyses are followed to identify key parameters affecting the local fin effect revealing TC wire diameter has the most significant influence. A correlation is developed from the sensitivity analysis results to estimate accurate cladding temperatures, demonstrating the potential of adjustment method using computational models.
- Open Access
- 30 March 2026
- Published by Office of Scientific and Technical Information (OSTI)
Overview of IMPACT Data Acquisition System and Data Reduction Process
This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.
- 30 March 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessOverview of IMPACT Data Acquisition System and Data Reduction Process
This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.
- 25 February 2026
- Published by Office of Scientific and Technical Information (OSTI)
Thermal Performance of Neutron Sensor Qualification Device
The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.
- 25 February 2026
- Published by Office of Scientific and Technical Information (OSTI)
Thermal Performance of Neutron Sensor Qualification Device
The neutron sensor qualification device was developed to provide a temperature-controlled environment for neutron sensors and dosimetry, enabling irradiation in a neutron field at the Armed Forces Radiobiology Research Institute (AFRRI) TRIGA reactor facility. The device, constructed from low-activation and low neutron cross-section materials, features a modular tube furnace design with three independently controlled heating zones for controlling axial temperature distribution. Laboratory testing validated the device's thermal performance, including uniform temperature distribution with less than 6°C variation across the central region, a steady-state operational temperature of 350°C achieved in approximately 3 hours, and a cooling time constant of 3.5 hours. External surface temperatures remained safe for handling, with the surrounding aluminum structure remaining at ambient conditions. The results confirm the device’s suitability for neutron sensor qualification experiments, with potential for future operation at higher temperatures and further optimization of performance.
- Open Access
- 1 July 2025
- Published by Office of Scientific and Technical Information (OSTI)
Performance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs
The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).
- 1 July 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessPerformance Testing of Enhanced Linear Variable Integrated Sensor (ELVIS III) for LVDTs
The Enhanced Linear Variable Intrinsic Sensor (ELVIS) was a 2024 breakthrough discovery by Idaho National Laboratory (INL) in terms of further innovating the usage of all linear variable differential transformers (LVDTs) and enhancing their performance in harsh environments. In irradiation tests conducted within material test reactors (MTRs), LVDTs with an internal temperature sensing capability can address several critical challenges. This report focuses on performance testing of the ELVIS III device with new hybrid LVDTs provided by the Institute for Energy Technology (IFE), which is the world’s sole supplier of nuclear-grade LVDTs. The ELVIS III device was evaluated in terms of temperature showcasing promising results comparable to a typical type-K thermocouple (TC).
- Open Access
- 29 May 2025
- Published by Office of Scientific and Technical Information (OSTI)
HDG-1 Fiber Bragg grating data analysis
The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.
- 29 May 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessHDG-1 Fiber Bragg grating data analysis
The main goal of the High dose graphite 1 Advanced test reactor experiment was to study nuclear grade graphite at high fluences. Additional supplementary optical fiber instrumentation was added to this long duration experiment for instrumentation development purposes. The supplementary instrumentation consisted of two pure silica core, fluorine doped cladding optical fibers each etched with 9 fiber Bragg gratings, one fiber being heat treated for 9 hours at 750 C and 16 hours at 750 C, the other being heat treated for 24 hours at 550 C and 48 hours at 650 C. Fiber Bragg gratings are known to have issues of measurement drift when in high temperature and high radiation environments like what is encountered in the Advanced test reactor. At the culmination of this experiment, the optical fibers saw ~1.3E21 n/cm2 total fluence, which is at the highest fluences that fiber Bragg gratings have been studied to date. Reported here is the analysis of this data including radiation induced shift and changes in sensitivity.
- Open Access
- 1 September 2024
- Published by Office of Scientific and Technical Information (OSTI)
Performance Test of Mini LVDT - ELVIS
The Institute for Energy (IFE) Technology has been a pioneer in the development of Linear Variable Differential Transformers (LVDTs) for in-pile testing, deploying over 2,200 units in various reactor environments with less than a 10% failure rate after five years of operation. This report focuses on the performance testing of IFE’s Mini LVDT, a compact sensor ideal for material test reactor experiments. The Mini LVDT, with a limited range of +/- 1.5 mm, offers excellent performance comparable to larger LVDTs, making it valuable in space-constrained applications. The development of an Enhanced Linear Variable Intrinsic Sensor (ELVIS) with internal temperature monitoring capabilities represents a significant advancement, addressing the critical need for real-time, accurate measurements in high-radiation and high-temperature environments. Two ELVIS prototypes were evaluated in terms of both temperature and displacement, showcasing promising results, though challenges with noise during temperature measurements were identified. This report summarizes the rigorous testing performed at Idaho National Laboratory (INL) and highlights the potential applications of Mini LVDTs and ELVIS in nuclear and other high-precision industries.
- 1 September 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessPerformance Test of Mini LVDT - ELVIS
The Institute for Energy (IFE) Technology has been a pioneer in the development of Linear Variable Differential Transformers (LVDTs) for in-pile testing, deploying over 2,200 units in various reactor environments with less than a 10% failure rate after five years of operation. This report focuses on the performance testing of IFE’s Mini LVDT, a compact sensor ideal for material test reactor experiments. The Mini LVDT, with a limited range of +/- 1.5 mm, offers excellent performance comparable to larger LVDTs, making it valuable in space-constrained applications. The development of an Enhanced Linear Variable Intrinsic Sensor (ELVIS) with internal temperature monitoring capabilities represents a significant advancement, addressing the critical need for real-time, accurate measurements in high-radiation and high-temperature environments. Two ELVIS prototypes were evaluated in terms of both temperature and displacement, showcasing promising results, though challenges with noise during temperature measurements were identified. This report summarizes the rigorous testing performed at Idaho National Laboratory (INL) and highlights the potential applications of Mini LVDTs and ELVIS in nuclear and other high-precision industries.
- Open Access
- 29 August 2024
- Published by Office of Scientific and Technical Information (OSTI)
Laboratory Testing of the Temperature Sensor Qualification Device
The Temperature sensor Qualification Device (TQD) has been developed and tested under laboratory conditions to evaluate its thermal performance and the reliability of its retractable sensor system. The TQD is designed to provide an isothermal environment for temperature sensors in both test and reference zones during irradiation experiments. Initial testing revealed minimal radial and azimuthal temperature variations but identified a significant axial gradient. To address this, design modifications were implemented, including enhanced insulation and the addition of a small heater at the device's top. These changes are expected to produce a more uniform axial temperature profile, though further testing is recommended prior to irradiation. The retractable sensor mechanism was rigorously tested, achieving 1,350 cycles at room temperature and 332 cycles at 400°C before failure. The primary failure mechanism was the thermocouple becoming stuck in the wire guide or capillary tube. Based on these results, design improvements were proposed, such as incorporating a load cell for force monitoring and a stepper motor for precise sensor positioning.
- 29 August 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessLaboratory Testing of the Temperature Sensor Qualification Device
The Temperature sensor Qualification Device (TQD) has been developed and tested under laboratory conditions to evaluate its thermal performance and the reliability of its retractable sensor system. The TQD is designed to provide an isothermal environment for temperature sensors in both test and reference zones during irradiation experiments. Initial testing revealed minimal radial and azimuthal temperature variations but identified a significant axial gradient. To address this, design modifications were implemented, including enhanced insulation and the addition of a small heater at the device's top. These changes are expected to produce a more uniform axial temperature profile, though further testing is recommended prior to irradiation. The retractable sensor mechanism was rigorously tested, achieving 1,350 cycles at room temperature and 332 cycles at 400°C before failure. The primary failure mechanism was the thermocouple becoming stuck in the wire guide or capillary tube. Based on these results, design improvements were proposed, such as incorporating a load cell for force monitoring and a stepper motor for precise sensor positioning.