Timo Rath
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Timo Rath has a total of 173 co-authors. Here are the top co-authors by number of shared publications:
Markus F. Neurath
Deutsches Zentrum Immuntherapie DZI, FAU University Erlangen-Nürnberg
12 shared publicationsAndreas Nägel
10 shared publicationsFrancesco Vitali
8 shared publicationsMarkus Neurath
Department of Medicine 1, University Hospital Erlangen, Erlangen, Germany
8 shared publicationsRaja Atreya
Department of Internal Medicine 1, Division of Gastroenterology, Ludwig Demling Endoscopy Center of Excellence, Friedrich-Alexander-University, Erlangen- Nuernberg, Germany
8 shared publications- Raja Atreya
Medical Department 1, University Hospital Erlangen, Friedrich-Alexander-University of Erlangen-Nürnberg , 91054 Erlangen
8 shared publications
Latest Publications
- 1 April 2026
- Published by American Physiological Society in American Journal of Physiology-Gastrointestinal and Liver Physiology
- Vol. 330 (4) , G424-G458
Tools and advanced imaging technologies for assessing intestinal epithelial barrier integrity: a systematic review
The intestinal epithelium is a key component of the intestinal barrier, which is the largest and most complex barrier of the human body, regulating nutrient absorption while restricting the entry of harmful antigens. Breakdown of this barrier facilitates microbial and dietary antigenic translocation, triggering local immune system activation and inflammation. Although barrier alteration alone may not be sufficient to initiate disease, accumulating evidence highlights its critical role in the pathogenesis and progression of a wide range of gastrointestinal and systemic disorders. Early identification of intestinal epithelium and barrier alterations could enable timely therapeutic approaches. This systematic review provides an overview of current in vivo (both noninvasive and invasive) and ex vivo/in vitro approaches used to assess intestinal epithelial barrier alterations. Noninvasive in vivo approaches rely mainly on urinary detection of orally ingested probes, but their clinical utility is limited by lack of standardization and specificity. Circulating and fecal constitutive markers derived from the intestinal barrier, which reflect epithelial alterations, together with indicators of microbial translocation, provide complementary insights but remain insufficiently validated. Advanced invasive endoscopic modalities such as confocal laser endomicroscopy enable near-histological, real-time visualization but are costly and largely used as research tools in specialist centers. In vitro, transepithelial electrical resistance assessment remains the reference standard, though novel technologies (including impedance spectroscopy and organic electrochemical transistors) offer enhanced sensitivity and resolution. Despite progress, major gaps remain, including the absence of a standardized definition of epithelial barrier breakdown, the lack of a practical diagnostic tool, methodological heterogeneity, unvalidated thresholds, and limited prospective validation.
- 1 April 2026
- Published by American Physiological Society in American Journal of Physiology-Gastrointestinal and Liver Physiology
- Vol. 330 (4) , G424-G458
Tools and advanced imaging technologies for assessing intestinal epithelial barrier integrity: a systematic review
The intestinal epithelium is a key component of the intestinal barrier, which is the largest and most complex barrier of the human body, regulating nutrient absorption while restricting the entry of harmful antigens. Breakdown of this barrier facilitates microbial and dietary antigenic translocation, triggering local immune system activation and inflammation. Although barrier alteration alone may not be sufficient to initiate disease, accumulating evidence highlights its critical role in the pathogenesis and progression of a wide range of gastrointestinal and systemic disorders. Early identification of intestinal epithelium and barrier alterations could enable timely therapeutic approaches. This systematic review provides an overview of current in vivo (both noninvasive and invasive) and ex vivo/in vitro approaches used to assess intestinal epithelial barrier alterations. Noninvasive in vivo approaches rely mainly on urinary detection of orally ingested probes, but their clinical utility is limited by lack of standardization and specificity. Circulating and fecal constitutive markers derived from the intestinal barrier, which reflect epithelial alterations, together with indicators of microbial translocation, provide complementary insights but remain insufficiently validated. Advanced invasive endoscopic modalities such as confocal laser endomicroscopy enable near-histological, real-time visualization but are costly and largely used as research tools in specialist centers. In vitro, transepithelial electrical resistance assessment remains the reference standard, though novel technologies (including impedance spectroscopy and organic electrochemical transistors) offer enhanced sensitivity and resolution. Despite progress, major gaps remain, including the absence of a standardized definition of epithelial barrier breakdown, the lack of a practical diagnostic tool, methodological heterogeneity, unvalidated thresholds, and limited prospective validation.
- 18 December 2025
- Published by Springer Nature in Die Innere Medizin
- Vol. 67 (1) , 46-54
Chronisch-entzündliche Darmerkrankungen
Zusammenfassung Chronisch-entzündliche Darmerkrankungen (CED), insbesondere Colitis ulcerosa (CU) und Morbus Crohn (MC), sind chronisch schubweise verlaufende Entzündungen des Gastrointestinaltrakts. Ihre Pathogenese beruht auf einer gestörten Regulation des intestinalen Immunsystems gegenüber kommensalen Mikroorganismen, wobei eine genetische Veranlagung die Grundlage für die anhaltende Entzündungsreaktion bildet. Während die therapeutische Strategie früher primär auf die Kontrolle klinischer Symptome durch medikamentöse Maßnahmen ausgerichtet war, belegen aktuelle Studien, dass eine endoskopisch nachgewiesene Remission hinsichtlich Krankheitsverlauf und Prognose der rein symptomatischen Kontrolle überlegen ist. Dieser Übersichtsartikel beleuchtet die Bedeutung der Endoskopie im Management von CED, stellt etablierte Scoring-Systeme zur endoskopischen Bewertung der Entzündungsaktivität vor und erläutert, in welchen Situationen und nach welchen Leitlinien eine endoskopische Diagnostik indiziert ist. Nicht zuletzt halten Anwendungen und Algorithmen der künstlichen Intelligenz sowie Mikroskopie-Technologien Einzug in die Endoskopie bei CED Patienten; diese werden im vorliegenden Beitrag ebenfalls dargestellt.
- 18 December 2025
- Published by Springer Nature in Die Innere Medizin
- Vol. 67 (1) , 46-54
Chronisch-entzündliche Darmerkrankungen
Zusammenfassung Chronisch-entzündliche Darmerkrankungen (CED), insbesondere Colitis ulcerosa (CU) und Morbus Crohn (MC), sind chronisch schubweise verlaufende Entzündungen des Gastrointestinaltrakts. Ihre Pathogenese beruht auf einer gestörten Regulation des intestinalen Immunsystems gegenüber kommensalen Mikroorganismen, wobei eine genetische Veranlagung die Grundlage für die anhaltende Entzündungsreaktion bildet. Während die therapeutische Strategie früher primär auf die Kontrolle klinischer Symptome durch medikamentöse Maßnahmen ausgerichtet war, belegen aktuelle Studien, dass eine endoskopisch nachgewiesene Remission hinsichtlich Krankheitsverlauf und Prognose der rein symptomatischen Kontrolle überlegen ist. Dieser Übersichtsartikel beleuchtet die Bedeutung der Endoskopie im Management von CED, stellt etablierte Scoring-Systeme zur endoskopischen Bewertung der Entzündungsaktivität vor und erläutert, in welchen Situationen und nach welchen Leitlinien eine endoskopische Diagnostik indiziert ist. Nicht zuletzt halten Anwendungen und Algorithmen der künstlichen Intelligenz sowie Mikroskopie-Technologien Einzug in die Endoskopie bei CED Patienten; diese werden im vorliegenden Beitrag ebenfalls dargestellt.
- Open Access
- 9 December 2025
- Published by Wolters Kluwer Health in Clinical and Translational Gastroenterology
- Vol. 17 (2) , e00963
Effect of Combination of a Mucosal Exposure Device and Computer-Aided Detection in Diagnostic, Screening, and Surveillance Colonoscopy: An International, Multicenter Study
INTRODUCTION: Mucosal exposure devices (MEDs) and computer-aided detection (CADe) systems may both improve adenoma detection through distinct mechanisms: expanding mucosal visualization and highlighting lesions, respectively. This study investigated the efficacy of combining CADe-assisted colonoscopy with a MED compared with CADe-assisted colonoscopy alone. METHODS: This international, multicenter, prospective, nonrandomized, single-arm study (NTC05220345) was conducted at 3 centers that also participated in the previous DISCOVERY II randomized controlled trial, comparing CADe-assisted with conventional colonoscopy. Eligible participants were patients referred for diagnostic, nonfecal immunochemical test screening, or surveillance colonoscopy and underwent CADe-assisted colonoscopy (DISCOVERY, PENTAX Medical) with a MED using an integrated inflatable balloon (G-EYE, SMART Medical Systems). The primary outcome was adenoma detection rate (ADR); secondary outcomes included sessile serrated lesion detection rate and withdrawal time without interventions. Outcomes were compared with historical controls of the CADe-arm of the DISCOVERY II study. RESULTS: Of 196 enrolled participants, 182 were included in the final analysis and compared with 250 participants from the historical CADe-arm. ADR was 47.3% in the CADe + MED-group vs 38.4% in the CADe-group ( P = .066; absolute difference: 8.9%, 95% confidence interval: 0.6–18.3). Mixed-effects logistic regression model adjusting for clustering and confounders calculated an odds ratio of 1.16 (95% confidence interval: 0.74–1.81). Median withdrawal time was slightly longer with CADe + MED compared with CADe-only (10.0 vs 9.2 minutes, P = 0.004), whereas sessile serrated lesion detection rate was not significantly different (12.6% vs 18.4%, P = 0.11). DISCUSSION: In this study using historical controls, CADe-assisted colonoscopy combined with a MED did not significantly increase ADR compared with CADe alone, suggesting limited synergistic benefit.
- 9 December 2025
- Published by Wolters Kluwer Health in Clinical and Translational Gastroenterology
- Vol. 17 (2) , e00963
Open AccessEffect of Combination of a Mucosal Exposure Device and Computer-Aided Detection in Diagnostic, Screening, and Surveillance Colonoscopy: An International, Multicenter Study
INTRODUCTION: Mucosal exposure devices (MEDs) and computer-aided detection (CADe) systems may both improve adenoma detection through distinct mechanisms: expanding mucosal visualization and highlighting lesions, respectively. This study investigated the efficacy of combining CADe-assisted colonoscopy with a MED compared with CADe-assisted colonoscopy alone. METHODS: This international, multicenter, prospective, nonrandomized, single-arm study (NTC05220345) was conducted at 3 centers that also participated in the previous DISCOVERY II randomized controlled trial, comparing CADe-assisted with conventional colonoscopy. Eligible participants were patients referred for diagnostic, nonfecal immunochemical test screening, or surveillance colonoscopy and underwent CADe-assisted colonoscopy (DISCOVERY, PENTAX Medical) with a MED using an integrated inflatable balloon (G-EYE, SMART Medical Systems). The primary outcome was adenoma detection rate (ADR); secondary outcomes included sessile serrated lesion detection rate and withdrawal time without interventions. Outcomes were compared with historical controls of the CADe-arm of the DISCOVERY II study. RESULTS: Of 196 enrolled participants, 182 were included in the final analysis and compared with 250 participants from the historical CADe-arm. ADR was 47.3% in the CADe + MED-group vs 38.4% in the CADe-group ( P = .066; absolute difference: 8.9%, 95% confidence interval: 0.6–18.3). Mixed-effects logistic regression model adjusting for clustering and confounders calculated an odds ratio of 1.16 (95% confidence interval: 0.74–1.81). Median withdrawal time was slightly longer with CADe + MED compared with CADe-only (10.0 vs 9.2 minutes, P = 0.004), whereas sessile serrated lesion detection rate was not significantly different (12.6% vs 18.4%, P = 0.11). DISCUSSION: In this study using historical controls, CADe-assisted colonoscopy combined with a MED did not significantly increase ADR compared with CADe alone, suggesting limited synergistic benefit.
- Open Access
- 24 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (13) , 1595
Interesting Images: Endocytoscopy for In Vivo Diagnosis of Intestinal Graft-Versus-Host Disease
Gastrointestinal graft-versus-host disease (GvHD) is a frequent and severe complication after allogeneic stem cell transplantation (aSCTx). Although biopsy and histopathology remain the gold standard for diagnosis of GvHD, this approach can be limited by thrombocytopenia accompanying aSCTx and the diagnostic delay associated with routine histopathology. Here, we report on two patients in which dye-based contact microscopy using a latest generation endocytoscope with 520-fold magnification enabled in vivo diagnosis of GvHD. The first patient was a 23-year-old man with acute lymphoblastic leukemia presenting with non-bloody diarrhea 3 months after aSCTx. After topical staining with crystal violet and methylene blue, endocytoscopy in the rectum showed several apoptotic epithelial cells. Histopathology confirmed GvHD grade III according to the Lerner classification. The second patient was a 59-year-old female with diarrhea 3 months after aSCTx. Apart from pathognomic apoptotic bodies, EC additionally revealed crypt lumina enlargement and mononuclear cell infiltrates in the lamina propria with subsequent crypt distension. The duration of the procedure was less than 5 min in each patient. These findings illustrate that in vivo microscopy using endocytoscopy can enable instantaneous diagnosis of GvHD with the benefit of accelerating therapeutic decisions in patients with suspected severe GvHD.
- 24 June 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (13) , 1595
Open AccessInteresting Images: Endocytoscopy for In Vivo Diagnosis of Intestinal Graft-Versus-Host Disease
Gastrointestinal graft-versus-host disease (GvHD) is a frequent and severe complication after allogeneic stem cell transplantation (aSCTx). Although biopsy and histopathology remain the gold standard for diagnosis of GvHD, this approach can be limited by thrombocytopenia accompanying aSCTx and the diagnostic delay associated with routine histopathology. Here, we report on two patients in which dye-based contact microscopy using a latest generation endocytoscope with 520-fold magnification enabled in vivo diagnosis of GvHD. The first patient was a 23-year-old man with acute lymphoblastic leukemia presenting with non-bloody diarrhea 3 months after aSCTx. After topical staining with crystal violet and methylene blue, endocytoscopy in the rectum showed several apoptotic epithelial cells. Histopathology confirmed GvHD grade III according to the Lerner classification. The second patient was a 59-year-old female with diarrhea 3 months after aSCTx. Apart from pathognomic apoptotic bodies, EC additionally revealed crypt lumina enlargement and mononuclear cell infiltrates in the lamina propria with subsequent crypt distension. The duration of the procedure was less than 5 min in each patient. These findings illustrate that in vivo microscopy using endocytoscopy can enable instantaneous diagnosis of GvHD with the benefit of accelerating therapeutic decisions in patients with suspected severe GvHD.
- Open Access
- 14 April 2022
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (S 01) , S18-S19
A VIRTUAL CHROMOENDOSCOPY ARTIFICIAL INTELLIGENCE SYSTEM TO DETECT ENDOSCOPIC AND HISTOLOGIC REMISSION IN ULCERATIVE COLITIS
Aims We aimed to develop an artificial intelligence (AI) system to assess endoscopic remission (ER) and histologic remission (HR) of ulcerative colitis (UC) in both white light (WL, using Ulcerative Colitis Endoscopic Index of Severity [UCEIS]) and virtual chromoendoscopy (VCE, using Paddington International Virtual ChromoendoScopy ScOre [PICaSSO]). Methods A convolutional neural network (CNN) was developed based on 559 endoscopy videos, from 302 UC patients prospectively included in the PICaSSO multicentre study. The videos were divided in training (254), validation (62), and testing (243), and comprised 67280 frames in total. The CNN was trained to predict both ER (defined as UCEIS≤1 in WL and as PICaSSO≤3 in VCE) and HR (defined as Robarts Histological Index ≤ 3 with no neutrophils in lamina propria or epithelium) in video clips. Results In the validation cohort, our system predicted ER in WL videos with 82% sensitivity, 94% specificity and an area under the ROC curve (AUROC) of 0.92. In VCE, sensitivity was 74%, specificity 95%, and AUROC 0.95. In the testing cohort, the diagnostic performance remained similar. The diagnostic performance for the prediction of HR in the validation set had sensitivity, specificity, and accuracy of 92%, 83%, and 85%, respectively, using VCE; and 83%, 87%, and 86% respectively, with WL. In the testing set, these metrics declined modestly while remaining good. Of note, the algorithm’s prediction of histology was similar with VCE and WL videos. Conclusions Our AI system accurately recognizes ER in videos and predicts HR equally well. Publication Date: 14 April 2022 (online) © 2022. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2022
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (S 01) , S18-S19
Open AccessA VIRTUAL CHROMOENDOSCOPY ARTIFICIAL INTELLIGENCE SYSTEM TO DETECT ENDOSCOPIC AND HISTOLOGIC REMISSION IN ULCERATIVE COLITIS
Aims We aimed to develop an artificial intelligence (AI) system to assess endoscopic remission (ER) and histologic remission (HR) of ulcerative colitis (UC) in both white light (WL, using Ulcerative Colitis Endoscopic Index of Severity [UCEIS]) and virtual chromoendoscopy (VCE, using Paddington International Virtual ChromoendoScopy ScOre [PICaSSO]). Methods A convolutional neural network (CNN) was developed based on 559 endoscopy videos, from 302 UC patients prospectively included in the PICaSSO multicentre study. The videos were divided in training (254), validation (62), and testing (243), and comprised 67280 frames in total. The CNN was trained to predict both ER (defined as UCEIS≤1 in WL and as PICaSSO≤3 in VCE) and HR (defined as Robarts Histological Index ≤ 3 with no neutrophils in lamina propria or epithelium) in video clips. Results In the validation cohort, our system predicted ER in WL videos with 82% sensitivity, 94% specificity and an area under the ROC curve (AUROC) of 0.92. In VCE, sensitivity was 74%, specificity 95%, and AUROC 0.95. In the testing cohort, the diagnostic performance remained similar. The diagnostic performance for the prediction of HR in the validation set had sensitivity, specificity, and accuracy of 92%, 83%, and 85%, respectively, using VCE; and 83%, 87%, and 86% respectively, with WL. In the testing set, these metrics declined modestly while remaining good. Of note, the algorithm’s prediction of histology was similar with VCE and WL videos. Conclusions Our AI system accurately recognizes ER in videos and predicts HR equally well. Publication Date: 14 April 2022 (online) © 2022. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 March 2022
- Published by Georg Thieme Verlag KG in Gastroenterologie up2date
- Vol. 18 (01) , 19-22
Endoskopische Therapie des Buried Bumper – Schritt für Schritt
Der Buried Bumper ist eine seltene, aber schwerwiegende Langzeitkomplikation der perkutanen enteralen Gastrostomie. Insbesondere beim vollständigen Einwachsen der Halteplatte kann die endoskopische Freilegung und Entfernung schwierig sein. Dieser Beitrag beschreibt, wie ein Buried Bumper sicher und einfach mit dem ersten eigens dafür vorgesehenen Mukotom, dem Flamingo (Fa. Fujifilm, Medwork), endoskopisch therapiert werden kann. Publication Date: 14 March 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 March 2022
- Published by Georg Thieme Verlag KG in Gastroenterologie up2date
- Vol. 18 (01) , 19-22
Endoskopische Therapie des Buried Bumper – Schritt für Schritt
Der Buried Bumper ist eine seltene, aber schwerwiegende Langzeitkomplikation der perkutanen enteralen Gastrostomie. Insbesondere beim vollständigen Einwachsen der Halteplatte kann die endoskopische Freilegung und Entfernung schwierig sein. Dieser Beitrag beschreibt, wie ein Buried Bumper sicher und einfach mit dem ersten eigens dafür vorgesehenen Mukotom, dem Flamingo (Fa. Fujifilm, Medwork), endoskopisch therapiert werden kann. Publication Date: 14 March 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 December 2021
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (05) , 473-474
Missed lesions and artificial intelligence during colonoscopy: the tireless working expert in the room
Although colonoscopy is generally considered to be the most accurate screening modality for detecting polyps, a substantial number of polyps are still missed. Recent data show a worrying proportion of missed lesions during screening or surveillance colonoscopy. In a meta-analysis of 43 publications and more than 15 000 tandem colonoscopies, miss rates of 26 % for adenomas, 9 % for advanced adenomas, and 27 % for serrated polyps were calculated [1]. Needless to say, missed lesions, especially missed advanced adenomas, may have the potential to develop into cancer, and it is thought that at least 50 % of all interval colorectal cancers arise from lesions missed during colonoscopy [2]. “Computer-aided detection systems can be subject to bias, with preferential detection of those lesions that were contained within the training set.” This begs the question of why we miss lesions during colonoscopy. Clearly, several factors contribute to missed lesions and the past decade has shown that use of auxiliary devices and techniques that increase mucosal exposure, such as distal attachment devices (caps, endorings, endocuff), balloon-assisted colonoscopy, or behind-fold visualizing technologies, can increase detection or reduce miss rates [3] [4] [5]. However, even with optimized mucosal exposure and a polyp being within the visual field, a lesion can still be missed by the endoscopist and several hypotheses have been offered to explain this. The first involves perceptual phenomena called “inattentional blindness,” where an observer experiences a lapse of focus (e. g. distraction), and “change blindness,” where a change in a visual stimulus is introduced (e. g. a polyp entering the visual field) but goes unnoticed by the endoscopist. Fatigue or emotional states may also contribute to missed lesions. Awareness of these factors and the scale of the problem has led to the development of artificial intelligence (AI) systems to assist the endoscopist in polyp detection. Such computer-aided detection (CADe) systems can detect, highlight, and alert the endoscopist, often using an acoustic signal, to the presence of a polyp within the visual field. Thus, lesions that might otherwise be missed, for whatever reason, will be detected constantly and consistently during colonoscopy examinations. During the past 2 years, several studies, including randomized controlled trails (RCTs), have analyzed detection rates using different CADe systems, so it is tempting to question why we need to focus on miss rates under AI, especially in studies that are single centered and nonrandomized. However, the adenoma miss rate (AMR) serves a valuable function. First, owing to the nature of tandem studies, AMR is a more direct and representative parameter than the adenoma detection rate (ADR) for analysis of individual endoscopist performance, either with or without CADe. Second, the AMR, and especially the miss rate of advanced adenomas, directly translates into clinical relevance. Advanced adenomas are estimated to progress to colorectal cancer at the rate of 1 % per year, and based on the prevalence of advanced adenomas and the number of screening and surveillance colonoscopies performed in the USA, it is estimated that 1700–9200 interval cancers resulting from missed advanced adenomas will occur within the next 10 years [6] [7]. Given this association and the fact that various CADe systems have entered the market in the past 2 years, the scarcity of data on the influence of AI on AMR is surprising. The elegant prospective trial by Zippelius et al. [8] in this issue of Endoscopy is one of the first real-world datasets on miss rates with the use of AI. In this trial, 150 patients undergoing routine colonoscopy at a single endoscopy center in Germany were examined in parallel by an endoscopist and the commercially available CADe system GI Genius (Medtronic, Minneapolis, Minnesota, USA) using two opposing screens, with the AI screen observed by a second observer and not visible to the endoscopist. Using this approach, the authors found neither significant nor clinically relevant differences in the AMR between the CADe system and conventional colonoscopy performed by experienced endoscopists. Furthermore, the polyp miss rate as a secondary endpoint was virtually identical between the CADe system and conventional colonoscopy. Importantly, the ADR, which was already high during conventional colonoscopy (52.0 %), did not increase with the use of CADe (50.7 %). Despite these “negative” results, the study by Zippelius et al. adds an important piece to the puzzle when all aspects are considered. Although the study did not show any decrease in AMR with the use of CADe, it did demonstrate that miss rates under AI were similarly low to those of experienced endoscopists participating in the study. Of note, pooled AMR for all endoscopists was 2 %, and almost 60 % of the endoscopists exhibited an ADR > 50 %, indicating a high level of colonoscopy expertise in this study. In 2020, Wang et al. analyzed the influence of a different CADe system on AMR in a randomized setting and found significantly lower polyp and adenoma miss rates with CADe colonoscopy compared with routine colonoscopy [9]. While these results seem contradictory to those presented by Zippelius et al., it is worth pointing out that the AMR of 40 % in the Wang et al., RCT was remarkably high for conventional colonoscopy, compared with the very low AMR of 2 % in the Zippelius et al. study. Furthermore, any AI system can only be as good as the data used to train it. CADe systems, including the GI Genius system used in the current study, are usually developed using training sets comprising images that have been manually annotated by experts. CADe systems can therefore be subject to bias, with preferential detection of those lesions that were contained within the training set. With such potential variation in the images...
- 14 December 2021
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 54 (05) , 473-474
Missed lesions and artificial intelligence during colonoscopy: the tireless working expert in the room
Although colonoscopy is generally considered to be the most accurate screening modality for detecting polyps, a substantial number of polyps are still missed. Recent data show a worrying proportion of missed lesions during screening or surveillance colonoscopy. In a meta-analysis of 43 publications and more than 15 000 tandem colonoscopies, miss rates of 26 % for adenomas, 9 % for advanced adenomas, and 27 % for serrated polyps were calculated [1]. Needless to say, missed lesions, especially missed advanced adenomas, may have the potential to develop into cancer, and it is thought that at least 50 % of all interval colorectal cancers arise from lesions missed during colonoscopy [2]. “Computer-aided detection systems can be subject to bias, with preferential detection of those lesions that were contained within the training set.” This begs the question of why we miss lesions during colonoscopy. Clearly, several factors contribute to missed lesions and the past decade has shown that use of auxiliary devices and techniques that increase mucosal exposure, such as distal attachment devices (caps, endorings, endocuff), balloon-assisted colonoscopy, or behind-fold visualizing technologies, can increase detection or reduce miss rates [3] [4] [5]. However, even with optimized mucosal exposure and a polyp being within the visual field, a lesion can still be missed by the endoscopist and several hypotheses have been offered to explain this. The first involves perceptual phenomena called “inattentional blindness,” where an observer experiences a lapse of focus (e. g. distraction), and “change blindness,” where a change in a visual stimulus is introduced (e. g. a polyp entering the visual field) but goes unnoticed by the endoscopist. Fatigue or emotional states may also contribute to missed lesions. Awareness of these factors and the scale of the problem has led to the development of artificial intelligence (AI) systems to assist the endoscopist in polyp detection. Such computer-aided detection (CADe) systems can detect, highlight, and alert the endoscopist, often using an acoustic signal, to the presence of a polyp within the visual field. Thus, lesions that might otherwise be missed, for whatever reason, will be detected constantly and consistently during colonoscopy examinations. During the past 2 years, several studies, including randomized controlled trails (RCTs), have analyzed detection rates using different CADe systems, so it is tempting to question why we need to focus on miss rates under AI, especially in studies that are single centered and nonrandomized. However, the adenoma miss rate (AMR) serves a valuable function. First, owing to the nature of tandem studies, AMR is a more direct and representative parameter than the adenoma detection rate (ADR) for analysis of individual endoscopist performance, either with or without CADe. Second, the AMR, and especially the miss rate of advanced adenomas, directly translates into clinical relevance. Advanced adenomas are estimated to progress to colorectal cancer at the rate of 1 % per year, and based on the prevalence of advanced adenomas and the number of screening and surveillance colonoscopies performed in the USA, it is estimated that 1700–9200 interval cancers resulting from missed advanced adenomas will occur within the next 10 years [6] [7]. Given this association and the fact that various CADe systems have entered the market in the past 2 years, the scarcity of data on the influence of AI on AMR is surprising. The elegant prospective trial by Zippelius et al. [8] in this issue of Endoscopy is one of the first real-world datasets on miss rates with the use of AI. In this trial, 150 patients undergoing routine colonoscopy at a single endoscopy center in Germany were examined in parallel by an endoscopist and the commercially available CADe system GI Genius (Medtronic, Minneapolis, Minnesota, USA) using two opposing screens, with the AI screen observed by a second observer and not visible to the endoscopist. Using this approach, the authors found neither significant nor clinically relevant differences in the AMR between the CADe system and conventional colonoscopy performed by experienced endoscopists. Furthermore, the polyp miss rate as a secondary endpoint was virtually identical between the CADe system and conventional colonoscopy. Importantly, the ADR, which was already high during conventional colonoscopy (52.0 %), did not increase with the use of CADe (50.7 %). Despite these “negative” results, the study by Zippelius et al. adds an important piece to the puzzle when all aspects are considered. Although the study did not show any decrease in AMR with the use of CADe, it did demonstrate that miss rates under AI were similarly low to those of experienced endoscopists participating in the study. Of note, pooled AMR for all endoscopists was 2 %, and almost 60 % of the endoscopists exhibited an ADR > 50 %, indicating a high level of colonoscopy expertise in this study. In 2020, Wang et al. analyzed the influence of a different CADe system on AMR in a randomized setting and found significantly lower polyp and adenoma miss rates with CADe colonoscopy compared with routine colonoscopy [9]. While these results seem contradictory to those presented by Zippelius et al., it is worth pointing out that the AMR of 40 % in the Wang et al., RCT was remarkably high for conventional colonoscopy, compared with the very low AMR of 2 % in the Zippelius et al. study. Furthermore, any AI system can only be as good as the data used to train it. CADe systems, including the GI Genius system used in the current study, are usually developed using training sets comprising images that have been manually annotated by experts. CADe systems can therefore be subject to bias, with preferential detection of those lesions that were contained within the training set. With such potential variation in the images...
- Open Access
- 4 December 2021
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 37 (2) , 381-391
The outcome of patients with inflammatory bowel disease–associated colorectal cancer is not worse than that of patients with sporadic colorectal cancer–a matched-pair analysis of survival
Purpose: Patients with inflammatory bowel disease (IBD) have an increased risk for colorectal cancer (CRC). In IBD patients, cancer is often diagnosed in advanced stages and conflicting data on survival compared to sporadic CRC have been reported. The aim of this study was to directly compare clinical characteristics and prognosis of patients with IBD-CRC and sporadic CRC. Methods: The clinical and pathological data of 63 patients with IBD-CRC and 3710 patients with sporadic CRC treated at the University Hospital of Erlangen between 1995 and 2015 were compared. Forty-seven M0 patients with IBD were matched with sporadic CRC patients after curative resection (R0) according to tumor localization, stage, sex, and year of treatment. Overall and disease-free survival were compared. Results: Sixty-three patients presented IBD-CRC. Fifty were affected with ulcerative colitis (UC) and 13 with Crohn’s disease (CD). CRC was diagnosed within 1.45 years since last endoscopic surveillance. Twelve patients (19%) had a diagnosis of primary sclerosing cholangitis. In matched analysis, IBD patients were diagnosed with CRC at younger age compared to sporadic CRC and were more likely to have right-sided CRC (40% versus 23.3%) and rare histological subtypes (19% versus 9.2%). No differences in 5-year overall (78.7 versus 80.9 months) and 5-year disease-free survival (74.5 versus 70.2 months) were noted. Conclusion: IBD-CRC patients were younger and more frequently had right-sided carcinomas compared to sporadic CRC. CRC in IBD patients did not show survival difference compared to matched-pair sporadic CRC patients without distant metastases after curative resection. Surveillance might be important for early detection of CRC in IBD patients.
- 4 December 2021
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 37 (2) , 381-391
Open AccessThe outcome of patients with inflammatory bowel disease–associated colorectal cancer is not worse than that of patients with sporadic colorectal cancer–a matched-pair analysis of survival
Purpose: Patients with inflammatory bowel disease (IBD) have an increased risk for colorectal cancer (CRC). In IBD patients, cancer is often diagnosed in advanced stages and conflicting data on survival compared to sporadic CRC have been reported. The aim of this study was to directly compare clinical characteristics and prognosis of patients with IBD-CRC and sporadic CRC. Methods: The clinical and pathological data of 63 patients with IBD-CRC and 3710 patients with sporadic CRC treated at the University Hospital of Erlangen between 1995 and 2015 were compared. Forty-seven M0 patients with IBD were matched with sporadic CRC patients after curative resection (R0) according to tumor localization, stage, sex, and year of treatment. Overall and disease-free survival were compared. Results: Sixty-three patients presented IBD-CRC. Fifty were affected with ulcerative colitis (UC) and 13 with Crohn’s disease (CD). CRC was diagnosed within 1.45 years since last endoscopic surveillance. Twelve patients (19%) had a diagnosis of primary sclerosing cholangitis. In matched analysis, IBD patients were diagnosed with CRC at younger age compared to sporadic CRC and were more likely to have right-sided CRC (40% versus 23.3%) and rare histological subtypes (19% versus 9.2%). No differences in 5-year overall (78.7 versus 80.9 months) and 5-year disease-free survival (74.5 versus 70.2 months) were noted. Conclusion: IBD-CRC patients were younger and more frequently had right-sided carcinomas compared to sporadic CRC. CRC in IBD patients did not show survival difference compared to matched-pair sporadic CRC patients without distant metastases after curative resection. Surveillance might be important for early detection of CRC in IBD patients.
- Open Access
- 17 June 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-9
Cross-sectional imaging of intestinal barrier dysfunction by confocal laser endomicroscopy can identify patients with food allergy in vivo with high sensitivity
Food allergy (FA) affects approximately 3 to 4% of the adult population in westernized countries. Suspected FA is even more prevalent and requires extensive diagnostic work-up. Within this study, we evaluated whether assessment of the integrity of the epithelial barrier by confocal laser endomicroscopy (CLE) during colonoscopy can be used as a screening tool to identify patients with FA. 60 patients with suspected FA were prospectively included. Serology with total and food-specific IgE, anti-tissue transglutaminase, skin prick testing, food intolerance tests, food intake registration and assessment of clinical complaints were performed. During colonocopy, standardized CLE was performed in the terminal ileum and at two colorectal sites. Analysis of CLE images included functional (i.e. presence of epithelial barrier dysfunction) and quantitative parameters of intestinal architecture. 27 of 60 patients (45%) were diagnosed with FA. Barrier dysfunction was analyzed on 65.837 ileal and on 93.251 colonic images. 96% of patients with FA exhibited functional and structural barrier defects while barrier dysfunction was found in only 33% of patients without FA (p < 0.0001). Visualizing barrier dysfunction with CLE for in vivo diagnosis of FA had a sensitivity and specificity of 96% and 67%, respectively, with a positive and negative prediction of 70% and 96%, respectively. Parameters intrinsic to the crypt architecture including crypt diameter, intercrypt distance, crypt lumen diameter and colonic vasculature were not different between patients with and without FA. CLE-based imaging of the intestinal barrier during colonoscopy might help in stratifying patients with suspected FA for further diagnostic work-up.
- 17 June 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-9
Open AccessCross-sectional imaging of intestinal barrier dysfunction by confocal laser endomicroscopy can identify patients with food allergy in vivo with high sensitivity
Food allergy (FA) affects approximately 3 to 4% of the adult population in westernized countries. Suspected FA is even more prevalent and requires extensive diagnostic work-up. Within this study, we evaluated whether assessment of the integrity of the epithelial barrier by confocal laser endomicroscopy (CLE) during colonoscopy can be used as a screening tool to identify patients with FA. 60 patients with suspected FA were prospectively included. Serology with total and food-specific IgE, anti-tissue transglutaminase, skin prick testing, food intolerance tests, food intake registration and assessment of clinical complaints were performed. During colonocopy, standardized CLE was performed in the terminal ileum and at two colorectal sites. Analysis of CLE images included functional (i.e. presence of epithelial barrier dysfunction) and quantitative parameters of intestinal architecture. 27 of 60 patients (45%) were diagnosed with FA. Barrier dysfunction was analyzed on 65.837 ileal and on 93.251 colonic images. 96% of patients with FA exhibited functional and structural barrier defects while barrier dysfunction was found in only 33% of patients without FA (p < 0.0001). Visualizing barrier dysfunction with CLE for in vivo diagnosis of FA had a sensitivity and specificity of 96% and 67%, respectively, with a positive and negative prediction of 70% and 96%, respectively. Parameters intrinsic to the crypt architecture including crypt diameter, intercrypt distance, crypt lumen diameter and colonic vasculature were not different between patients with and without FA. CLE-based imaging of the intestinal barrier during colonoscopy might help in stratifying patients with suspected FA for further diagnostic work-up.
- Open Access
- 21 May 2021
- Published by Wolters Kluwer Health in European Journal of Gastroenterology & Hepatology
- Vol. 33 (1S) , e662-e669
Computer-aided detection of colorectal polyps using a newly generated deep convolutional neural network: from development to first clinical experience
Aim: The use of artificial intelligence represents an objective approach to increase endoscopist’s adenoma detection rate (ADR) and limit interoperator variability. In this study, we evaluated a newly developed deep convolutional neural network (DCNN) for automated detection of colorectal polyps ex vivo as well as in a first in-human trial. Methods: For training of the DCNN, 116 529 colonoscopy images from 278 patients with 788 different polyps were collected. A subset of 10 467 images containing 504 different polyps were manually annotated and treated as the gold standard. An independent set of 45 videos consisting of 15 534 single frames was used for ex vivo performance testing. In vivo real-time detection of colorectal polyps during routine colonoscopy by the DCNN was tested in 42 patients in a back-to-back approach. Results: When analyzing the test set of 15 534 single frames, the DCNN’s sensitivity and specificity for polyp detection and localization within the frame was 90% and 80%, respectively, with an area under the curve of 0.92. In vivo, baseline polyp detection rate and ADR were 38% and 26% and significantly increased to 50% (P = 0.023) and 36% (P = 0.044), respectively, with the use of the DCNN. Of the 13 additionally with the DCNN detected lesions, the majority were diminutive and flat, among them three sessile serrated adenomas. Conclusion: This newly developed DCNN enables highly sensitive automated detection of colorectal polyps both ex vivo and during first in-human clinical testing and could potentially increase the detection of colorectal polyps during colonoscopy.
- 21 May 2021
- Published by Wolters Kluwer Health in European Journal of Gastroenterology & Hepatology
- Vol. 33 (1S) , e662-e669
Open AccessComputer-aided detection of colorectal polyps using a newly generated deep convolutional neural network: from development to first clinical experience
Aim: The use of artificial intelligence represents an objective approach to increase endoscopist’s adenoma detection rate (ADR) and limit interoperator variability. In this study, we evaluated a newly developed deep convolutional neural network (DCNN) for automated detection of colorectal polyps ex vivo as well as in a first in-human trial. Methods: For training of the DCNN, 116 529 colonoscopy images from 278 patients with 788 different polyps were collected. A subset of 10 467 images containing 504 different polyps were manually annotated and treated as the gold standard. An independent set of 45 videos consisting of 15 534 single frames was used for ex vivo performance testing. In vivo real-time detection of colorectal polyps during routine colonoscopy by the DCNN was tested in 42 patients in a back-to-back approach. Results: When analyzing the test set of 15 534 single frames, the DCNN’s sensitivity and specificity for polyp detection and localization within the frame was 90% and 80%, respectively, with an area under the curve of 0.92. In vivo, baseline polyp detection rate and ADR were 38% and 26% and significantly increased to 50% (P = 0.023) and 36% (P = 0.044), respectively, with the use of the DCNN. Of the 13 additionally with the DCNN detected lesions, the majority were diminutive and flat, among them three sessile serrated adenomas. Conclusion: This newly developed DCNN enables highly sensitive automated detection of colorectal polyps both ex vivo and during first in-human clinical testing and could potentially increase the detection of colorectal polyps during colonoscopy.