Shinya Kitagawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shinya Kitagawa has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
Hajime Ohtani
Program Life Science and Materials Chemistry, Department of Engineering, Graduate School of Engineering, Nagoya Institute of Technology
33 shared publicationsYoshinori Iiguni
Program Life Science and Materials Chemistry, Department of Engineering, Graduate School of Engineering, Nagoya Institute of Technology
11 shared publications- Hajime Ohtani
Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology, Nagoya 466-8555, Japan
6 shared publications - Takao Tsuda
Department of Applied Chemistry, Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya, Japan
6 shared publications Tomohiro Motono
Department of Life Science and Applied Chemistry, Graduate School of Engineering, Nagoya Institute of Technology
5 shared publicationsNobuyuki Shibata
Nagoya Municipal Industrial Research Institute
4 shared publications
Latest Publications
- Open Access
- 20 October 2025
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 46 (3) , 145-151
Retention in Cryogenic HPLC Using Various Linear and Branched Alkyl Chains Stationary Phases Modified on Silica-Gel Particles
The retention of ethane in cryogenic high performance liquid chromatography (HPLC) at -196 °C was investigated by comparing with the retentions in ambient temperature gas chromatography (GC) at 50 °C (analyte: n-pentane) and ambient temperature HPLC at 25 °C (analyte: acenaphthene) using commercially available linear (trimethyl, dimethyl-n-butyl, dimethyl-n-octyl, and dimethyl-n-octadecyl silica) and laboratory-made branched alkyl chain (dimethylisopropyl and dimethylthexyl silica) stationary phases. For this investigation, the densities of the functional and end capping groups were evaluated using the carbon and hydrogen contents in the packing materials, as measured by CHNS analysis. To evaluate retention in each stationary phase and separation mode, the retention factor per single functional group and the retention per single carbon unit (CH2 or CH3) were calculated. A detailed study on the retention behavior revealed that the retention behavior observed with linear alkyl chain stationary phases in cryogenic HPLC was similar to that in ambient temperature GC, but not ambient temperature HPLC. The stationary phase of the branched thexyl group resulted in a weak interaction for the test analytes in HPLC-196°C and HPLC25°C. By contrast, the stationary phase of the isopropyl group did not suppress the analyte retention in either liquid chromatography.
- 20 October 2025
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 46 (3) , 145-151
Open AccessRetention in Cryogenic HPLC Using Various Linear and Branched Alkyl Chains Stationary Phases Modified on Silica-Gel Particles
The retention of ethane in cryogenic high performance liquid chromatography (HPLC) at -196 °C was investigated by comparing with the retentions in ambient temperature gas chromatography (GC) at 50 °C (analyte: n-pentane) and ambient temperature HPLC at 25 °C (analyte: acenaphthene) using commercially available linear (trimethyl, dimethyl-n-butyl, dimethyl-n-octyl, and dimethyl-n-octadecyl silica) and laboratory-made branched alkyl chain (dimethylisopropyl and dimethylthexyl silica) stationary phases. For this investigation, the densities of the functional and end capping groups were evaluated using the carbon and hydrogen contents in the packing materials, as measured by CHNS analysis. To evaluate retention in each stationary phase and separation mode, the retention factor per single functional group and the retention per single carbon unit (CH2 or CH3) were calculated. A detailed study on the retention behavior revealed that the retention behavior observed with linear alkyl chain stationary phases in cryogenic HPLC was similar to that in ambient temperature GC, but not ambient temperature HPLC. The stationary phase of the branched thexyl group resulted in a weak interaction for the test analytes in HPLC-196°C and HPLC25°C. By contrast, the stationary phase of the isopropyl group did not suppress the analyte retention in either liquid chromatography.
- Open Access
- 1 September 2025
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 73 (3) , 170-171
Analysis of Synthetic Polymers in ESI-IM-MS/MS
- 1 September 2025
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 73 (3) , 170-171
Open AccessAnalysis of Synthetic Polymers in ESI-IM-MS/MS
- 8 January 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (4) , 385-393
Compositional analysis of traditional liquid gold with separation of compounds containing heavy atoms in ion mobility-mass spectrometry
“Liquid gold” has been traditionally used for over a century to decorate ceramicware, but its chemical composition has not been thoroughly investigated. One of the keys to successfully characterizing liquid gold, which is a complex mixture, is to distinguish Au-containing products from other chemicals. In this paper, we propose a separation based on the difference in collision cross section, of which chemicals with heavy atoms are relatively smaller than those without in ion mobility-mass spectrometry (IM-MS). Chemicals containing a single Au atom (and Pt atom) were successfully separated from other species in the two-dimensional distribution map for IM-MS. By a detailed analysis of the spectra obtained by IM-MS/MS with collision-induced dissociation before and after IM separation, we found that liquid gold (gold resinate) was a mixture of a series of (1) Au reacted with α-pinene-related units and (2) Au reacted with abietic acid units. α-Pinene and abietic acid are the main components of turpentine and rosin, the raw materials of liquid gold as reported previously (Anal. Sci. 2024, 40, 133–139). All Au-containing species contain sulfur atoms. Species of Au reacted with α-pinene-related units with different degrees of unsaturation and oxidation have also been identified. Liquid gold, a complex mixture of chemicals containing Au, has been successfully analyzed compositionally. Graphical abstract
- 8 January 2025
- Published by Springer Nature in Analytical Sciences
- Vol. 41 (4) , 385-393
Compositional analysis of traditional liquid gold with separation of compounds containing heavy atoms in ion mobility-mass spectrometry
“Liquid gold” has been traditionally used for over a century to decorate ceramicware, but its chemical composition has not been thoroughly investigated. One of the keys to successfully characterizing liquid gold, which is a complex mixture, is to distinguish Au-containing products from other chemicals. In this paper, we propose a separation based on the difference in collision cross section, of which chemicals with heavy atoms are relatively smaller than those without in ion mobility-mass spectrometry (IM-MS). Chemicals containing a single Au atom (and Pt atom) were successfully separated from other species in the two-dimensional distribution map for IM-MS. By a detailed analysis of the spectra obtained by IM-MS/MS with collision-induced dissociation before and after IM separation, we found that liquid gold (gold resinate) was a mixture of a series of (1) Au reacted with α-pinene-related units and (2) Au reacted with abietic acid units. α-Pinene and abietic acid are the main components of turpentine and rosin, the raw materials of liquid gold as reported previously (Anal. Sci. 2024, 40, 133–139). All Au-containing species contain sulfur atoms. Species of Au reacted with α-pinene-related units with different degrees of unsaturation and oxidation have also been identified. Liquid gold, a complex mixture of chemicals containing Au, has been successfully analyzed compositionally. Graphical abstract
- Open Access
- 20 October 2024
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 45 (3) , 129-132
Analysis of Single Sub-Millimeter Microplastic Particles by Capillary Size Exclusion Chromatography
In recent years, microplastics (MPs) have emerged as a significant environmental concern. The degradation state of MPs in the actual environment varies for each microparticle. For a comprehensive risk assessment of MPs, it is crucial to evaluate diversity at the individual particle level and to analyze measured properties statistically. In this study, we developed capillary size-exclusion chromatography (capillary SEC, inner diameter 0.250 mm × 480 mm) to analyze the molecular weight distribution of MPs at the single-particle level. Additionally, we devised a method for handling single particles to measure samples at the single-particle level using a sampling capillary (inner diameter 0.150 mm × 80 mm). We successfully demonstrated the analysis of a single polystyrene particle with a diameter of 90 μm.
- 20 October 2024
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 45 (3) , 129-132
Open AccessAnalysis of Single Sub-Millimeter Microplastic Particles by Capillary Size Exclusion Chromatography
In recent years, microplastics (MPs) have emerged as a significant environmental concern. The degradation state of MPs in the actual environment varies for each microparticle. For a comprehensive risk assessment of MPs, it is crucial to evaluate diversity at the individual particle level and to analyze measured properties statistically. In this study, we developed capillary size-exclusion chromatography (capillary SEC, inner diameter 0.250 mm × 480 mm) to analyze the molecular weight distribution of MPs at the single-particle level. Additionally, we devised a method for handling single particles to measure samples at the single-particle level using a sampling capillary (inner diameter 0.150 mm × 80 mm). We successfully demonstrated the analysis of a single polystyrene particle with a diameter of 90 μm.
- 20 February 2024
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 45 (1) , 35-39
Development of Cryogenic HPLC for Wide Range Low Temperatures Using Liquefied Propane as Mobile Phase and Its Application to Hydrogen/Deuterium Compounds Separation
In this study, a novel cryogenic high-performance liquid chromatography (HPLC) system, where the separation temperature can be controlled from -196 to -50 °C, was developed using liquefied propane as the mobile phase. Pyrene retention in a bare silicagel column increased as the column temperature decreased, ranging from -130 to -50 °C. The linear van't Hoff plot for pyrene (r2 = 0.9926) suggested that a variation in the retention mechanism for pyrene did not occur in this temperature range. The separation of pyrene and pyrene-d10 was enhanced by the decrease in the separation temperature in the bare silica-gel column, that is, the H/D selectivity increased with a decrease in temperature. The H/D pyrene was not separated in an ODS column even though the cryogenic HPLC at -90 °C. This suggested that hydrogen bonding between H/D pyrene and hydroxy groups in the mobile phase chemicals is essential for H/D separation in reversed-phase HPLC.
- 20 February 2024
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 45 (1) , 35-39
Development of Cryogenic HPLC for Wide Range Low Temperatures Using Liquefied Propane as Mobile Phase and Its Application to Hydrogen/Deuterium Compounds Separation
In this study, a novel cryogenic high-performance liquid chromatography (HPLC) system, where the separation temperature can be controlled from -196 to -50 °C, was developed using liquefied propane as the mobile phase. Pyrene retention in a bare silicagel column increased as the column temperature decreased, ranging from -130 to -50 °C. The linear van't Hoff plot for pyrene (r2 = 0.9926) suggested that a variation in the retention mechanism for pyrene did not occur in this temperature range. The separation of pyrene and pyrene-d10 was enhanced by the decrease in the separation temperature in the bare silica-gel column, that is, the H/D selectivity increased with a decrease in temperature. The H/D pyrene was not separated in an ODS column even though the cryogenic HPLC at -90 °C. This suggested that hydrogen bonding between H/D pyrene and hydroxy groups in the mobile phase chemicals is essential for H/D separation in reversed-phase HPLC.
- 13 October 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (1) , 133-139
Characterization of balsam sulfide via pyrolysis–gas chromatography–mass spectrometry/sulfur chemiluminescence detection and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
Balsam sulfide, produced by the reaction of turpentine/rosin and sulfur, has been used as one of the raw materials of liquid gold to decorate ceramics and tableware with thin gold film for more than 100 years. The characterization of balsam sulfide is still insufficient because of its compositional complexity. In this study, balsam sulfide was characterized using pyrolysis–gas chromatography (Py-GC)–mass spectrometry (MS) and Py-GC with sulfur chemiluminescence detection (SCD) as well as matrix-assisted laser desorption/ionization time-of-flight MS (MALDI-TOFMS). Py-GC–MS/SCD analyses of balsam sulfide and its model samples revealed that the low molecular weight reaction products were mainly composed of compounds of one α-pinene unit reacted with 1–3 sulfur atoms. In the analysis of the high molecular weight components by MALDI-TOFMS, the products of two or three α-pinene units crosslinked by sulfur atoms were observed. It was found that dehydrogenation reaction proceeded gradually with the increase in the reaction time. Graphical abstract
- 13 October 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 40 (1) , 133-139
Characterization of balsam sulfide via pyrolysis–gas chromatography–mass spectrometry/sulfur chemiluminescence detection and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry
Balsam sulfide, produced by the reaction of turpentine/rosin and sulfur, has been used as one of the raw materials of liquid gold to decorate ceramics and tableware with thin gold film for more than 100 years. The characterization of balsam sulfide is still insufficient because of its compositional complexity. In this study, balsam sulfide was characterized using pyrolysis–gas chromatography (Py-GC)–mass spectrometry (MS) and Py-GC with sulfur chemiluminescence detection (SCD) as well as matrix-assisted laser desorption/ionization time-of-flight MS (MALDI-TOFMS). Py-GC–MS/SCD analyses of balsam sulfide and its model samples revealed that the low molecular weight reaction products were mainly composed of compounds of one α-pinene unit reacted with 1–3 sulfur atoms. In the analysis of the high molecular weight components by MALDI-TOFMS, the products of two or three α-pinene units crosslinked by sulfur atoms were observed. It was found that dehydrogenation reaction proceeded gradually with the increase in the reaction time. Graphical abstract
- 5 September 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (11) , 1-5
Analysis of polyisoprene oligomers via in situ silver nanoparticle formation on thin-layer chromatography plate using matrix-assisted laser-induced desorption/ionization mass spectrometry
The direct mass spectrometry (MS) detection of polyisoprene (PI) oligomers on a thin-layer chromatography (TLC) plate using matrix-assisted laser-induced desorption/ionization (MALDI) with silver trifluoroacetate as the cationization reagent was investigated. The spots of PI oligomers and silver trifluoroacetate on the TLC plate resulted in brown materials after UV laser irradiation. It was suggested that silver trifluoroacetate yielded Ag nanoparticles as brown materials after heating via laser irradiation. The nanoparticles behaved as an inorganic matrix and a source of Ag+ adduct in the analysis of PI oligomers. The use of organic matrices together with silver trifluoroacetate reduced the signal intensity of PI oligomers on MALDI-MS on a TLC plate. The separation of PI oligomers (polymerization degree, n = 5–11) by TLC resulted in a single elliptical spot without a clear separation after the chromatographic procedure. However, in MS imaging, differences in migration lengths based on degrees of polymerization were clearly observed and the degrees of polymerization were identified without comparison with standards. Graphical abstract
- 5 September 2023
- Published by Springer Nature in Analytical Sciences
- Vol. 39 (11) , 1-5
Analysis of polyisoprene oligomers via in situ silver nanoparticle formation on thin-layer chromatography plate using matrix-assisted laser-induced desorption/ionization mass spectrometry
The direct mass spectrometry (MS) detection of polyisoprene (PI) oligomers on a thin-layer chromatography (TLC) plate using matrix-assisted laser-induced desorption/ionization (MALDI) with silver trifluoroacetate as the cationization reagent was investigated. The spots of PI oligomers and silver trifluoroacetate on the TLC plate resulted in brown materials after UV laser irradiation. It was suggested that silver trifluoroacetate yielded Ag nanoparticles as brown materials after heating via laser irradiation. The nanoparticles behaved as an inorganic matrix and a source of Ag+ adduct in the analysis of PI oligomers. The use of organic matrices together with silver trifluoroacetate reduced the signal intensity of PI oligomers on MALDI-MS on a TLC plate. The separation of PI oligomers (polymerization degree, n = 5–11) by TLC resulted in a single elliptical spot without a clear separation after the chromatographic procedure. However, in MS imaging, differences in migration lengths based on degrees of polymerization were clearly observed and the degrees of polymerization were identified without comparison with standards. Graphical abstract
- Open Access
- 2 May 2023
- Published by Springer Nature in International Journal of Metalcasting
- Vol. 17 (4) , 2523
Correction: Visualization of Microscopic Behavior of Atomized Flow in High-Pressure Die Casting Products Using a Multiphase Flow Analysis System
- 2 May 2023
- Published by Springer Nature in International Journal of Metalcasting
- Vol. 17 (4) , 2523
Open AccessCorrection: Visualization of Microscopic Behavior of Atomized Flow in High-Pressure Die Casting Products Using a Multiphase Flow Analysis System
- Open Access
- 20 February 2023
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 44 (1) , 1-9
Development of Novel Analytical Methods Based on Liquid Chromatography and Electrophoresis
High-performance liquid chromatography (HPLC) and electrophoresis are liquid phase separation methods and are frequently used in various research fields. Although their origins are sufficiently old, the development of novel separation methods based on HPLC and electrophoresis are still required for both fundamental and applicational functions. In this paper, we introduced our fundamental studies of the development of novel analytical methods based on HPLC and electrophoresis toward enhancing separation efficiency. The contents can be categorized as follows: (1) enhancement of separation in pressured flow-driven capillary electrochromatography, (2) orthogonal electrochromatography for simultaneous two-dimensional separation, (3) development of new stationary phases/columns in HPLC, (4) development of low and ultra-low-temperature HPLC using liquefied gas mobile phase, (5) development of nonaqueous capillary electrophoresis for analyzing water-insoluble synthetic polymers, and (6) development of frequency division multiplex HPLC-MS.
- 20 February 2023
- Published by The Society for Chromatographic Sciences in CHROMATOGRAPHY
- Vol. 44 (1) , 1-9
Open AccessDevelopment of Novel Analytical Methods Based on Liquid Chromatography and Electrophoresis
High-performance liquid chromatography (HPLC) and electrophoresis are liquid phase separation methods and are frequently used in various research fields. Although their origins are sufficiently old, the development of novel separation methods based on HPLC and electrophoresis are still required for both fundamental and applicational functions. In this paper, we introduced our fundamental studies of the development of novel analytical methods based on HPLC and electrophoresis toward enhancing separation efficiency. The contents can be categorized as follows: (1) enhancement of separation in pressured flow-driven capillary electrochromatography, (2) orthogonal electrochromatography for simultaneous two-dimensional separation, (3) development of new stationary phases/columns in HPLC, (4) development of low and ultra-low-temperature HPLC using liquefied gas mobile phase, (5) development of nonaqueous capillary electrophoresis for analyzing water-insoluble synthetic polymers, and (6) development of frequency division multiplex HPLC-MS.
- 2 January 2023
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 37 (5) , e9455
Characterization of styrene/methyl methacrylate/ n ‐butyl acrylate terpolymer with Kendrick mass defect analysis in electrospray ionization‐ion mobility spectrometry‐mass spectrometry
Rationale: Synthesis of copolymer is one of the major approaches to establish sophisticated polymers. In copolymer analysis in mass spectrometry (MS), an increase in the number of monomer unit species and/or the polymer molecular weight results in complex mass spectra, and a method is required to solve this problem. Methods: In this study, electrospray ionization‐ion mobility spectrometry‐mass spectrometry was employed to analyze styrene/methyl methacrylate/ n ‐butyl acrylate (St/MMA/nBA) terpolymers via Kendrick mass defect (KMD) analysis. An expanded Fourier transform‐based noise reduction method for the copolymer was developed to improve the decrease in the signal/noise ratio observed in the higher m / z region. Results: Low‐mass terpolymers (0.7 kDa) were identified by comparing the observed and theoretical results using a two‐dimensional KMD plot. For the 1.5 kDa terpolymer, the signal overlap, of which KMD value was not matched with the theoretical one, was interpreted by the shift from the theoretical value in the KMD plot. For the 3.0 kDa terpolymers, the compositional candidates were determined by the prediction based on the compositional information of low‐mass terpolymers previously analyzed. The 4.5 kDa terpolymer was interpreted after the expanded noise filtering. Conclusions: The terpolymers, whose molecular weight was up to 4.5 kDa, were successfully characterized at a molecular level. The dependency of the St/MMA/nBA composition on molecular weight was observed; that is, the nBA content decreased with an increase in the molecular weight.
- 2 January 2023
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 37 (5) , e9455
Characterization of styrene/methyl methacrylate/ n ‐butyl acrylate terpolymer with Kendrick mass defect analysis in electrospray ionization‐ion mobility spectrometry‐mass spectrometry
Rationale: Synthesis of copolymer is one of the major approaches to establish sophisticated polymers. In copolymer analysis in mass spectrometry (MS), an increase in the number of monomer unit species and/or the polymer molecular weight results in complex mass spectra, and a method is required to solve this problem. Methods: In this study, electrospray ionization‐ion mobility spectrometry‐mass spectrometry was employed to analyze styrene/methyl methacrylate/ n ‐butyl acrylate (St/MMA/nBA) terpolymers via Kendrick mass defect (KMD) analysis. An expanded Fourier transform‐based noise reduction method for the copolymer was developed to improve the decrease in the signal/noise ratio observed in the higher m / z region. Results: Low‐mass terpolymers (0.7 kDa) were identified by comparing the observed and theoretical results using a two‐dimensional KMD plot. For the 1.5 kDa terpolymer, the signal overlap, of which KMD value was not matched with the theoretical one, was interpreted by the shift from the theoretical value in the KMD plot. For the 3.0 kDa terpolymers, the compositional candidates were determined by the prediction based on the compositional information of low‐mass terpolymers previously analyzed. The 4.5 kDa terpolymer was interpreted after the expanded noise filtering. Conclusions: The terpolymers, whose molecular weight was up to 4.5 kDa, were successfully characterized at a molecular level. The dependency of the St/MMA/nBA composition on molecular weight was observed; that is, the nBA content decreased with an increase in the molecular weight.