Alec J. Bennett
Research Subjects
Alec J. Bennett has a total of 149 co-authors. Here are the top co-authors by number of shared publications:
F Rosner
8 shared publicationsP B Farnsworth
6 shared publicationsR. G. Harrison
Space and Atmospheric Electricity Group, Department of Meteorology University of Reading Reading UK
6 shared publications- Richard Giles Harrison
Department of Meteorology University of Reading UK
6 shared publications E J Cassell
5 shared publicationsA L Halpern
4 shared publications
Latest Publications
- Open Access
- 8 October 2026
- Published by Elsevier in SSRN Electronic Journal
Effects of Geyser Fountain Dynamics on the Atmospheric Electric Fields
Geyser eruptions generate transient water fountains that modify the atmospheric electric field under repeatable and well-constrained conditions. Yet, the mechanisms controlling the observed signals remain unclear. We present the first systematic investigation of short-term electric field fluctuations during geyser eruptions, combining electrical measurements with high-speed video observations at Strokkur geyser, Iceland. Using a Biral Thunderstorm Detector and an Electric Field Mill, we recorded electrical signals during eruption events in October 2025 and relate them directly to the evolving fountain geometry. We observe that the polarity and amplitude of electrical signals correlate strongly with the ambient atmospheric potential gradient. We develop a finite-element electrostatic model (FEMM) to quantify the partial electrostatic shielding effect of a grounded water fountain on the ambient electric field. We derive empirical equations relating fountain height, radius, and potential gradient to induced electrical currents, allowing for a direct comparison between modeled and observed signals. By inverting the electrical signal, we reconstruct time-varying fountain radii that agree with qualitative observations from independent high-speed videos. The close agreement between reconstructed and observed fountain geometry suggests that electrical signals can be explained by changes in the ambient atmospheric electric field by the conductive water column. These measurements provide a new, non-intrusive approach for quantifying geyser fountain dynamics.
- 8 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEffects of Geyser Fountain Dynamics on the Atmospheric Electric Fields
Geyser eruptions generate transient water fountains that modify the atmospheric electric field under repeatable and well-constrained conditions. Yet, the mechanisms controlling the observed signals remain unclear. We present the first systematic investigation of short-term electric field fluctuations during geyser eruptions, combining electrical measurements with high-speed video observations at Strokkur geyser, Iceland. Using a Biral Thunderstorm Detector and an Electric Field Mill, we recorded electrical signals during eruption events in October 2025 and relate them directly to the evolving fountain geometry. We observe that the polarity and amplitude of electrical signals correlate strongly with the ambient atmospheric potential gradient. We develop a finite-element electrostatic model (FEMM) to quantify the partial electrostatic shielding effect of a grounded water fountain on the ambient electric field. We derive empirical equations relating fountain height, radius, and potential gradient to induced electrical currents, allowing for a direct comparison between modeled and observed signals. By inverting the electrical signal, we reconstruct time-varying fountain radii that agree with qualitative observations from independent high-speed videos. The close agreement between reconstructed and observed fountain geometry suggests that electrical signals can be explained by changes in the ambient atmospheric electric field by the conductive water column. These measurements provide a new, non-intrusive approach for quantifying geyser fountain dynamics.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Linking Fountain Dynamics to Electric Field Variations: A Study of Strokkur Geyser
Geysers provide natural laboratories for studying eruptive dynamics, analogous to those observed at volcanoes, offering a safe and accessible setting in which processes can be observed at high spatial and temporal resolution. However, despite their easy accessibility and reliable activity, there is a lack of research regarding the electrical signals they generate. In this study, we investigate the source of electrical signals recorded by a Biral Thunderstorm Detector (BTD) in close proximity to Strokkur Geyser in Iceland. We focus on the effect known as shielding, where a moving conductive object connected to the ground distorts the electric field lines, inducing a current in a conductor, in our case, the BTD antenna. To test whether this effect is the source of the recorded signals, Finite Element Method Magnetics (FEMM) models are used to model the rising fountain. The results show that the induced charge and current are dependent on the fountain height, radius, and atmospheric potential gradient. We determine the atmospheric potential gradient using an electric field mill, colocated with the BTD, and measure the fountain height using video recordings. After deriving an empirical equation from the FEMM results, we can reproduce the measured BTD signal with the model by inverting for the fountain radius. Due to the high coherence between the signals and the good agreement between observed and calculated fountain radius, we conclude that the shielding effect is mostly responsible for the electric signals measured close to a geyser. This result is a significant contribution to understanding electric signals from various natural phenomena, including lava fountain activity and discharge generation in volcanic plumes.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessLinking Fountain Dynamics to Electric Field Variations: A Study of Strokkur Geyser
Geysers provide natural laboratories for studying eruptive dynamics, analogous to those observed at volcanoes, offering a safe and accessible setting in which processes can be observed at high spatial and temporal resolution. However, despite their easy accessibility and reliable activity, there is a lack of research regarding the electrical signals they generate. In this study, we investigate the source of electrical signals recorded by a Biral Thunderstorm Detector (BTD) in close proximity to Strokkur Geyser in Iceland. We focus on the effect known as shielding, where a moving conductive object connected to the ground distorts the electric field lines, inducing a current in a conductor, in our case, the BTD antenna. To test whether this effect is the source of the recorded signals, Finite Element Method Magnetics (FEMM) models are used to model the rising fountain. The results show that the induced charge and current are dependent on the fountain height, radius, and atmospheric potential gradient. We determine the atmospheric potential gradient using an electric field mill, colocated with the BTD, and measure the fountain height using video recordings. After deriving an empirical equation from the FEMM results, we can reproduce the measured BTD signal with the model by inverting for the fountain radius. Due to the high coherence between the signals and the good agreement between observed and calculated fountain radius, we conclude that the shielding effect is mostly responsible for the electric signals measured close to a geyser. This result is a significant contribution to understanding electric signals from various natural phenomena, including lava fountain activity and discharge generation in volcanic plumes.
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Electrical Signals Generated by Pyroclastic Density Currents at Stromboli Volcano
Electrical activity, including visible lightning, has been observed at Stromboli (Italy) during various eruptive scenarios and has also been reported in association with the emplacement of pyroclastic density currents (PDCs). The multiparametric monitoring network operating at Stromboli enables a detailed investigation of PDCs generated by a range of eruptive and gravitational processes, including column collapse during paroxysmal eruptions, crumbling of lava overflows, and collapses of the crater rim or flank. Previous analyses of the electrical activity at Stromboli have primarily focused on paroxysmal eruptions during which PDCs concurrently occurred, making it difficult to isolate and interpret electrical signatures generated by PDCs alone. PDCs generated by gravitational instabilities of volcaniclastic deposits, located on the crater rim or volcano flanks, offer a unique opportunity to investigate their electrical signatures in the absence of an eruptive column and other relevant syn-explosive processes. Here, we present analyses of electrical signals recorded during the occurrence of deposit-derived PDCs propagating along Sciara del Fuoco. Electrical activity was measured using a lightning detector deployed in close proximity to the flow pathway to monitor changes in the ambient electric field. Complementary thermal and visual imaging of the crater area and flow path enables correlation of the electrical signal variation with the timing, evolution, and spatial extent of the PDC events. We compare these observations with electrical signals recorded during eruptive activity at Stromboli involving sustained eruptive columns, to assess the similarities and differences between column-collapse PDCs and eruption-driven electrical signatures. Distinguishing different types of volcanic phenomena solely based on their electric signature offers a complementary approach for volcano monitoring, enabling the rapid detection of PDC occurrence and aiding the classification of explosive activity.
- 14 March 2026
- Published by Copernicus GmbH
Open AccessElectrical Signals Generated by Pyroclastic Density Currents at Stromboli Volcano
Electrical activity, including visible lightning, has been observed at Stromboli (Italy) during various eruptive scenarios and has also been reported in association with the emplacement of pyroclastic density currents (PDCs). The multiparametric monitoring network operating at Stromboli enables a detailed investigation of PDCs generated by a range of eruptive and gravitational processes, including column collapse during paroxysmal eruptions, crumbling of lava overflows, and collapses of the crater rim or flank. Previous analyses of the electrical activity at Stromboli have primarily focused on paroxysmal eruptions during which PDCs concurrently occurred, making it difficult to isolate and interpret electrical signatures generated by PDCs alone. PDCs generated by gravitational instabilities of volcaniclastic deposits, located on the crater rim or volcano flanks, offer a unique opportunity to investigate their electrical signatures in the absence of an eruptive column and other relevant syn-explosive processes. Here, we present analyses of electrical signals recorded during the occurrence of deposit-derived PDCs propagating along Sciara del Fuoco. Electrical activity was measured using a lightning detector deployed in close proximity to the flow pathway to monitor changes in the ambient electric field. Complementary thermal and visual imaging of the crater area and flow path enables correlation of the electrical signal variation with the timing, evolution, and spatial extent of the PDC events. We compare these observations with electrical signals recorded during eruptive activity at Stromboli involving sustained eruptive columns, to assess the similarities and differences between column-collapse PDCs and eruption-driven electrical signatures. Distinguishing different types of volcanic phenomena solely based on their electric signature offers a complementary approach for volcano monitoring, enabling the rapid detection of PDC occurrence and aiding the classification of explosive activity.
- Open Access
Storm Ciarán's effect on the boiling point of water in the southeast of the United Kingdom
The spatial atmospheric pressure field due to Storm Ciarán is investigated in the south‐east of the UK at high temporal and spatial resolution using data from roadside sites. During Ciarán’s passage, a reduction in the boiling point of water was measured at Reading, from which a wider effect on the boiling point of water associated with Ciarán was calculated for the populated regions of the southeast and London. For many people in this region on 2 November 2023, the boiling point of water at breakfast time would have been below the recommended temperature range for optimal brewing of tea.
Open AccessStorm Ciarán's effect on the boiling point of water in the southeast of the United Kingdom
The spatial atmospheric pressure field due to Storm Ciarán is investigated in the south‐east of the UK at high temporal and spatial resolution using data from roadside sites. During Ciarán’s passage, a reduction in the boiling point of water was measured at Reading, from which a wider effect on the boiling point of water associated with Ciarán was calculated for the populated regions of the southeast and London. For many people in this region on 2 November 2023, the boiling point of water at breakfast time would have been below the recommended temperature range for optimal brewing of tea.
- Open Access
- 9 July 2024
- Published by Springer Nature in Communications Earth & Environment
- Vol. 5 (1) , 1-13
Explosive eruption style modulates volcanic electrification signals
Volcanic lightning detection has proven useful to volcano monitoring by providing information on eruption onset, source parameters, and ash cloud directions. However, little is known about the influence of changing eruptive styles on the generation of charge and electrical discharges inside the eruption column. The 2021 Tajogaite eruption (La Palma, Canary Islands) provided the rare opportunity to monitor variations in electrical activity continuously over several weeks using an electrostatic lightning detector. Here we show that throughout the eruption, silicate particle charging is the main electrification mechanism. Moreover, we find that the type of electrical activity is closely linked to the explosive eruption style. Fluctuations in the electrical discharge rates are likely controlled by variations in the mass eruption rate and/or changes in the eruption style. These findings hold promise for obtaining near real-time information on the dynamic evolution of explosive volcanic activity through electrostatic monitoring in the future.
- 9 July 2024
- Published by Springer Nature in Communications Earth & Environment
- Vol. 5 (1) , 1-13
Open AccessExplosive eruption style modulates volcanic electrification signals
Volcanic lightning detection has proven useful to volcano monitoring by providing information on eruption onset, source parameters, and ash cloud directions. However, little is known about the influence of changing eruptive styles on the generation of charge and electrical discharges inside the eruption column. The 2021 Tajogaite eruption (La Palma, Canary Islands) provided the rare opportunity to monitor variations in electrical activity continuously over several weeks using an electrostatic lightning detector. Here we show that throughout the eruption, silicate particle charging is the main electrification mechanism. Moreover, we find that the type of electrical activity is closely linked to the explosive eruption style. Fluctuations in the electrical discharge rates are likely controlled by variations in the mass eruption rate and/or changes in the eruption style. These findings hold promise for obtaining near real-time information on the dynamic evolution of explosive volcanic activity through electrostatic monitoring in the future.
- Open Access
- 27 December 2021
- Published by MDPI AG in Atmosphere
- Vol. 13 (1) , 38
Long-Term Observations of Schumann Resonances at Portishead (UK)
Constructive interference of lightning-generated signals in the extremely low frequency (ELF) below 100 Hz is the source of a global electromagnetic phenomenon in the Earth’s atmosphere known as Schumann Resonances (SR). SR are excited at frequencies of 7.8, 14, 20, 26, … Hz, and their diurnal and seasonal intensity variations are largely dependent on changes in the location and magnitude of the major lightning centres in Southeast Asia, Africa, and South America. In the last five decades, extensive research has focused on reconstructing the spatial and temporal evolution in global lighting activity using SR measurements, and more recently on analysing the links to climate change, transient luminous events (TLE), and biological systems. In this study, a quasi-electrostatic antenna, primarily designed as a thunderstorm warning system, is for the first time applied to measure background variability in the SR band at an urban site in Southwest England. Data collected continuously from June 2015 for a 5-year period are suitably filtered and analysed showing that SR is the dominant contribution to the fair-weather displacement current measured by the sensor in the band 10–45 Hz. Diurnal and seasonal signal amplitude variations have been found to be consistent with previous studies and show the African-European lightning centre to prevail due to the shorter source-observer distance. Also, it is shown that long-term global changes in the ocean and land temperature, and the subsequent effect on the major lightning hotspots, may be responsible for the inter-annual variability of SR intensity, indicating that the largest increase occurred during the 2015–2016 super El-Niño episode.
- 27 December 2021
- Published by MDPI AG in Atmosphere
- Vol. 13 (1) , 38
Open AccessLong-Term Observations of Schumann Resonances at Portishead (UK)
Constructive interference of lightning-generated signals in the extremely low frequency (ELF) below 100 Hz is the source of a global electromagnetic phenomenon in the Earth’s atmosphere known as Schumann Resonances (SR). SR are excited at frequencies of 7.8, 14, 20, 26, … Hz, and their diurnal and seasonal intensity variations are largely dependent on changes in the location and magnitude of the major lightning centres in Southeast Asia, Africa, and South America. In the last five decades, extensive research has focused on reconstructing the spatial and temporal evolution in global lighting activity using SR measurements, and more recently on analysing the links to climate change, transient luminous events (TLE), and biological systems. In this study, a quasi-electrostatic antenna, primarily designed as a thunderstorm warning system, is for the first time applied to measure background variability in the SR band at an urban site in Southwest England. Data collected continuously from June 2015 for a 5-year period are suitably filtered and analysed showing that SR is the dominant contribution to the fair-weather displacement current measured by the sensor in the band 10–45 Hz. Diurnal and seasonal signal amplitude variations have been found to be consistent with previous studies and show the African-European lightning centre to prevail due to the shorter source-observer distance. Also, it is shown that long-term global changes in the ocean and land temperature, and the subsequent effect on the major lightning hotspots, may be responsible for the inter-annual variability of SR intensity, indicating that the largest increase occurred during the 2015–2016 super El-Niño episode.
- Open Access
- 1 October 2018
- Published by IOP Publishing in Environmental Research Letters
- Vol. 13 (10) , 109502
Corrigendum: Saharan dust plume charging observed over the UK 2018 ( Environ. Res. Lett. 13 054018)
A plume of Saharan dust and Iberian smoke was carried across the southern UK on 16th October 2017, entrained into an Atlantic cyclone which had originated as Hurricane Ophelia. The dust plume aloft was widely noticed as it was sufficiently dense to redden the visual appearance of the sun. Time series of backscatter from ceilometers at Reading and Chilbolton show two plumes: one carried upwards to 2.5 km, and another below 800m into the boundary layer, with a clear slot between. Steady descent of particles at about 5 cm s−1 continued throughout the morning, and coarse mode particles reached the surface. Plumes containing dust are frequently observed to be strongly charged, often through frictional effects. This plume passed over atmospheric electric field sensors at Bristol, Chilbolton and Reading. Consistent measurements at these three sites indicated negative plume charge. The lower edge plume charge density was (−8.0±3.3) nCm−2, which is several times greater than that typical for stratiform water clouds, implying an active in situ charge generation mechanism such as turbulent triboelectrification. A meteorological radiosonde measuring temperature and humidity was launched into the plume at 1412 UTC, specially instrumented with charge and turbulence sensors. This detected charge in the boundary layer and in the upper plume region, and strong turbulent mixing was observed throughout the atmosphere's lowest 4 km. The clear slot region, through which particles sedimented, was anomalously dry compared with modelled values, with water clouds forming intermittently in the air beneath. Electrical aspects of dust should be included in numerical models, particularly the charge-related effects on cloud microphysical properties, to accurately represent particle behaviour and transport.
- 1 October 2018
- Published by IOP Publishing in Environmental Research Letters
- Vol. 13 (10) , 109502
Open AccessCorrigendum: Saharan dust plume charging observed over the UK 2018 ( Environ. Res. Lett. 13 054018)
A plume of Saharan dust and Iberian smoke was carried across the southern UK on 16th October 2017, entrained into an Atlantic cyclone which had originated as Hurricane Ophelia. The dust plume aloft was widely noticed as it was sufficiently dense to redden the visual appearance of the sun. Time series of backscatter from ceilometers at Reading and Chilbolton show two plumes: one carried upwards to 2.5 km, and another below 800m into the boundary layer, with a clear slot between. Steady descent of particles at about 5 cm s−1 continued throughout the morning, and coarse mode particles reached the surface. Plumes containing dust are frequently observed to be strongly charged, often through frictional effects. This plume passed over atmospheric electric field sensors at Bristol, Chilbolton and Reading. Consistent measurements at these three sites indicated negative plume charge. The lower edge plume charge density was (−8.0±3.3) nCm−2, which is several times greater than that typical for stratiform water clouds, implying an active in situ charge generation mechanism such as turbulent triboelectrification. A meteorological radiosonde measuring temperature and humidity was launched into the plume at 1412 UTC, specially instrumented with charge and turbulence sensors. This detected charge in the boundary layer and in the upper plume region, and strong turbulent mixing was observed throughout the atmosphere's lowest 4 km. The clear slot region, through which particles sedimented, was anomalously dry compared with modelled values, with water clouds forming intermittently in the air beneath. Electrical aspects of dust should be included in numerical models, particularly the charge-related effects on cloud microphysical properties, to accurately represent particle behaviour and transport.
- Open Access
- 1 May 2018
- Published by IOP Publishing in Environmental Research Letters
- Vol. 13 (5) , 054018
Saharan dust plume charging observed over the UK
- 1 May 2018
- Published by IOP Publishing in Environmental Research Letters
- Vol. 13 (5) , 054018
Open AccessSaharan dust plume charging observed over the UK