LDLuzhen Deng

Luzhen Deng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Luzhen Deng has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Peng He

    Key Laboratory of Optoelectronic Technology and Systems (Ministry of Education), College of Optoelectronic Engineering, Chongqing University, Chongqing, China

    5 shared publications
  • Biao Wei

    Key Laboratory of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing, China

    4 shared publications
  • Mianyi Chen

    Key Lab of Optoelectronic Technology and Systems of the Education Ministry of China, Chongqing University, Chongqing, China

    4 shared publications
  • Peng Feng

    Key Laboratory of Optoelectronic Technology and Systems (Ministry of Education), College of Optoelectronic Engineering, Chongqing University, Chongqing, China

    2 shared publications
  • Biao Wei

    Key Laboratory of Optoelectronics Technology and System, Chongqing University, Ministry of Education, Chongqing 400044, China,

    1 shared publication
  • De-Ling Mi

    Key Laboratory of Opto-Electronics Technology & System, Chongqing University, Ministry of Education, Chongqing 400044, China

    1 shared publication

Latest Publications

  • Open Access

    A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging

    by Luzhen Deng, Biao Wei, Peng He, Yi Zhang, Peng Feng

    Background: X-ray fluorescence (XRF) computed tomography (XFCT) has shown promise for molecular imaging of metal nanoparticles such as gold nanoparticles (GNPs) and benchtop XFCT is under active development due to its easy access, low-cost instrumentation and operation. Purpose: To validate the performance of a Geant4-based Monte Carlo (MC) model of a benchtop multi-pinhole XFCT system for quantitative imaging of GNPs. Methods: The MC mode consisted of a fan-beam x-ray source (125 kVp), which was used to stimulate the emission of XRF from the GNPs, a phantom (3 cm in diameter) which included six or nine inserts (3 mm in diameter), each of which contained the same (1 wt. %) or various (0.08–1 wt. %) concentrations of GNPs, a multi-pinhole collimator which could acquire multiple projections simultaneously and a one-sided or two-sided two-dimensional (2D) detector. Various pinhole diameters (3.7, 2, 1, 0.5 and 0.25 mm) and various particle numbers (20, 40, 80 and 100 billion) were simulated and the results for single pinhole and multi-pinhole (9 pinholes) imaging were compared. Results: The image resolution for a 1 mm multi-pinhole was between 0.88 and 1.38 mm. The detection limit for multi-pinhole operation was about 0.09 wt. %, while that for the single pinhole was about 0.13 wt. %. For a fixed number of pinholes, noise increased with decreasing number of photons. Conclusion: The MC mode could acquire 2D slice images of the object without rotation and demonstrated that a multi-pinhole XFCT imaging system could be a potential bioimaging modality for nanomedical applications.


  • Open Access

    Monte Carlo Simulation for Polychromatic X-Ray Fluorescence Computed Tomography with Sheet-Beam Geometry

    by Shanghai Jiang, Peng He, Luzhen Deng, Mianyi Chen, Biao Wei

    X-ray fluorescence computed tomography (XFCT) based on sheet beam can save a huge amount of time to obtain a whole set of projections using synchrotron. However, it is clearly unpractical for most biomedical research laboratories. In this paper, polychromatic X-ray fluorescence computed tomography with sheet-beam geometry is tested by Monte Carlo simulation. First, two phantoms (A and B) filled with PMMA are used to simulate imaging process through GEANT 4. Phantom A contains several GNP-loaded regions with the same size (10 mm) in height and diameter but different Au weight concentration ranging from 0.3% to 1.8%. Phantom B contains twelve GNP-loaded regions with the same Au weight concentration (1.6%) but different diameter ranging from 1 mm to 9 mm. Second, discretized presentation of imaging model is established to reconstruct more accurate XFCT images. Third, XFCT images of phantoms A and B are reconstructed by filter back-projection (FBP) and maximum likelihood expectation maximization (MLEM) with and without correction, respectively. Contrast-to-noise ratio (CNR) is calculated to evaluate all the reconstructed images. Our results show that it is feasible for sheet-beam XFCT system based on polychromatic X-ray source and the discretized imaging model can be used to reconstruct more accurate images.


  • Open Access

    An Improved Total Variation Minimization Method Using Prior Images and Split-Bregman Method in CT Reconstruction

    by Luzhen Deng, Peng Feng, Mianyi Chen, Peng He, Biao Wei

    Compressive Sensing (CS) theory has great potential for reconstructing Computed Tomography (CT) images from sparse-views projection data and Total Variation- (TV-) based CT reconstruction method is very popular. However, it does not directly incorporate prior images into the reconstruction. To improve the quality of reconstructed images, this paper proposed an improved TV minimization method using prior images and Split-Bregman method in CT reconstruction, which uses prior images to obtain valuable previous information and promote the subsequent imaging process. The images obtained asynchronously were registered via Locally Linear Embedding (LLE). To validate the method, two studies were performed. Numerical simulation using an abdomen phantom has been used to demonstrate that the proposed method enables accurate reconstruction of image objects under sparse projection data. A real dataset was used to further validate the method.


  • Computed Tomography Image Reconstruction from Few-Views Data by Multi-Directional Total Variation

    by Chen Mian-Yi, Ren Yong, Feng Peng, He Peng, Deng Lu-Zhen, Wei Biao, Li Zhi-Chao, Wang Jian

    With the fact of harmfulness, X-ray radiation dose reduction received more and more attention in CT research field nowadays. As Compressed Sensing theory applied into Computed Tomography reconstruction algorithms make it possible to reconstruct high-quality CT images with the requirement of low radiation dose. One of research hot point in CS-based CT reconstruction algorithms is Total Variation, using the information of x-coordinate and y-coordinate gradients to reconstruct CT images, which implies that it will reconstruct better CT images by using gradients of more directions. In this paper, a CT reconstruction algorithm based on Multi-directional Total Variation (MdTV) was proposed, by using the information of x-coordinate, y-coordinate and diagonal gradient together to reconstruct CT images, which theoretically will reconstruct images with higher quality. Experimental results shows that, MdTV based reconstruction algorithm reconstruct better images than TV based algorithm, which is more helpful to reduce X-ray radiation dose as much as possible.


  • Open Access

    A CT Reconstruction Algorithm Based on L1/2Regularization

    by Mianyi Chen, Deling Mi, Peng He, Luzhen Deng, Biao Wei

    Computed tomography (CT) reconstruction with low radiation dose is a significant research point in current medical CT field. Compressed sensing has shown great potential reconstruct high-quality CT images from few-view or sparse-view data. In this paper, we use the sparser L1/2regularization operator to replace the traditional L1regularization and combine the Split Bregman method to reconstruct CT images, which has good unbiasedness and can accelerate iterative convergence. In the reconstruction experiments with simulation and real projection data, we analyze the quality of reconstructed images using different reconstruction methods in different projection angles and iteration numbers. Compared with algebraic reconstruction technique (ART) and total variance (TV) based approaches, the proposed reconstruction algorithm can not only get better images with higher quality from few-view data but also need less iteration numbers.