Rungun Nathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Rungun Nathan has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Qianhong Wu
Villanova University
15 shared publications - Ji Lang
School of Mechanical Engineering, Southeast University 1 , Nanjing 211189
9 shared publications Qianhong Wu
7 shared publications- Zenghao Zhu
Villanova Cellular Biomechanics and Sports Science Laboratory, Villanova, USA
5 shared publications Jevon M. Avis
Department of Mechanical Engineering , Villanova University , Villanova, PA 19085-1681, USA
4 shared publicationsQifu Wang
Cellular Biomechanics and Sports Science Laboratory, Villanova University 1 , 800 Lancaster Avenue, Villanova, Pennsylvania 19085
4 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (11)
Cavitation in translational brain impacts: The role of cerebrospinal fluid pressure and brain deformation dynamics
Traumatic brain injury (TBI) affects an estimated 69 million people worldwide annually and is associated with neurological disability. However, injury mechanisms and outcomes remain poorly understood, limiting protective and treatment strategies. The pressure response of cerebrospinal fluid (CSF) has gained attention due to evidence of intracranial cavitation. However, the severity of CSF pressurization remains unexplored. This study introduces an experimental system to examine CSF flow during translational impacts on the head by analyzing brain strain distribution, CSF pressurization, and skull acceleration responses. A head surrogate filled with a hydrogel brain model and a CSF-like medium was subjected to free-fall impacts recorded with an accelerometer, and intracranial pressures were measured at the coup (site of impact) and the contrecoup (opposite of impact). Results revealed that the contrecoup experienced significantly higher peak pressures, reaching 4.3 MPa at 544g, primarily due to cavitation. The coup displayed lower pressures, reaching 0.3 MPa at 550g. Strain analysis showed that the contrecoup exhibited the highest minimum principal strain (ϵmin), indicating greater susceptibility to compression and damage. A linear relationship between impact acceleration (a) and peak pressure (P) was observed in the coup (P = 0.0006a, R2 = 0.97) and the contrecoup (P = 0.0054a, R2 = 0.91), with more variability demonstrated in the contrecoup due to inconsistent formation and growth of cavitation bubbles. These findings suggest that cavitation plays a crucial role in TBI and helps localize damage. Understanding CSF cavitation may support protective technologies and pressure management strategies aimed at reducing injury progression, potentially lowering the risk of neurodegenerative conditions following TBI.
- 1 November 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (11)
Cavitation in translational brain impacts: The role of cerebrospinal fluid pressure and brain deformation dynamics
Traumatic brain injury (TBI) affects an estimated 69 million people worldwide annually and is associated with neurological disability. However, injury mechanisms and outcomes remain poorly understood, limiting protective and treatment strategies. The pressure response of cerebrospinal fluid (CSF) has gained attention due to evidence of intracranial cavitation. However, the severity of CSF pressurization remains unexplored. This study introduces an experimental system to examine CSF flow during translational impacts on the head by analyzing brain strain distribution, CSF pressurization, and skull acceleration responses. A head surrogate filled with a hydrogel brain model and a CSF-like medium was subjected to free-fall impacts recorded with an accelerometer, and intracranial pressures were measured at the coup (site of impact) and the contrecoup (opposite of impact). Results revealed that the contrecoup experienced significantly higher peak pressures, reaching 4.3 MPa at 544g, primarily due to cavitation. The coup displayed lower pressures, reaching 0.3 MPa at 550g. Strain analysis showed that the contrecoup exhibited the highest minimum principal strain (ϵmin), indicating greater susceptibility to compression and damage. A linear relationship between impact acceleration (a) and peak pressure (P) was observed in the coup (P = 0.0006a, R2 = 0.97) and the contrecoup (P = 0.0054a, R2 = 0.91), with more variability demonstrated in the contrecoup due to inconsistent formation and growth of cavitation bubbles. These findings suggest that cavitation plays a crucial role in TBI and helps localize damage. Understanding CSF cavitation may support protective technologies and pressure management strategies aimed at reducing injury progression, potentially lowering the risk of neurodegenerative conditions following TBI.
- 9 September 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 184
Rotational impact orientation effects traumatic brain injury severity, a biomimetic study
- 9 September 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 184
Rotational impact orientation effects traumatic brain injury severity, a biomimetic study
- 11 May 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 210, 111732
Experimentally validated CEL finite element modeling of probe insertion and cavity formation in agar gel for DBS applications
- 11 May 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 210, 111732
Experimentally validated CEL finite element modeling of probe insertion and cavity formation in agar gel for DBS applications
- 1 April 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (4)
A theoretical and experimental study of an oscillatory flow through a compliant tube
This paper presents a theoretical and experimental study of oscillatory flow through a finite compliant tube, aiming to investigate fluid–structure interactions in structures like blood vessels. The setup consists of a horizontally submerged polydimethylsiloxane tube mounted between two fixed ends, each instrumented with a pressure sensor. The device that provides the flow was custom-designed and manufactured by our team. It consists of two rigidly connected piston–cylinder assemblies that operate 180° out of phase, ensuring that the amount of fluid pushed into the tube from one end is identical to the amount pulled out from the other end, thereby making the flow purely oscillatory. Visualizing the flow inside a narrow tube with a constantly changing shape can be quite cumbersome, making corrections for light refraction distinctly challenging. Therefore, the tube's undulating shape is monitored using a high-speed camera. The instantaneous tube profile is obtained by processing the video offline in MATLAB. A theoretical model was developed to describe the tube's wall radial motion. The resulting equation was solved analytically for small deformations to obtain the predicted local deformation history. For radial deformations within ∼7%, the analytical solution agreed well with observation. Driven by this validation, a complete solution for the flow field is proposed within the small deformation limit. This study showcases a setup where a compliant tube's flow conditions are measured in tandem with its deformation, offering a unique avenue through which the fluid–structure interaction models in compliant tubes can be tested and refined.
- 1 April 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (4)
A theoretical and experimental study of an oscillatory flow through a compliant tube
This paper presents a theoretical and experimental study of oscillatory flow through a finite compliant tube, aiming to investigate fluid–structure interactions in structures like blood vessels. The setup consists of a horizontally submerged polydimethylsiloxane tube mounted between two fixed ends, each instrumented with a pressure sensor. The device that provides the flow was custom-designed and manufactured by our team. It consists of two rigidly connected piston–cylinder assemblies that operate 180° out of phase, ensuring that the amount of fluid pushed into the tube from one end is identical to the amount pulled out from the other end, thereby making the flow purely oscillatory. Visualizing the flow inside a narrow tube with a constantly changing shape can be quite cumbersome, making corrections for light refraction distinctly challenging. Therefore, the tube's undulating shape is monitored using a high-speed camera. The instantaneous tube profile is obtained by processing the video offline in MATLAB. A theoretical model was developed to describe the tube's wall radial motion. The resulting equation was solved analytically for small deformations to obtain the predicted local deformation history. For radial deformations within ∼7%, the analytical solution agreed well with observation. Driven by this validation, a complete solution for the flow field is proposed within the small deformation limit. This study showcases a setup where a compliant tube's flow conditions are measured in tandem with its deformation, offering a unique avenue through which the fluid–structure interaction models in compliant tubes can be tested and refined.