Kuihua Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kuihua Han has a total of 162 co-authors. Here are the top co-authors by number of shared publications:
Chunmei Lu
26 shared publications- Jianhui Qi
School of Nuclear Science, Energy and Power Engineering, Shandong University, Jinan 250061, China
16 shared publications Shengli Niu
Shandong University
13 shared publicationsJinxiao Li
11 shared publicationsHui Li
10 shared publicationsJigang Zhang
10 shared publications
Latest Publications
- Open Access
Simulation and Performance Analysis of a PVT-Assisted Ground-Source Heat Pump System with Mine Pit Seasonal Thermal Storage for a Cherry Greenhouse: A Case Study
In response to the significant seasonal fluctuations in heating and cooling loads in greenhouses for high-value fruit trees in northern China, as well as issues such as heat accumulation on the ground-source side and high carbon emissions from coal-fired heating, this paper proposes a coupled energy supply system comprising a PVT system, a mine pit seasonal thermal storage unit, a ground-source heat pump and a cooling tower. Taking a 30,000 m2 cherry greenhouse and an existing 15,000 m3 mine pit thermal storage reservoir in Weifang, Shandong Province, as the research objects, annual design-stage simulations with a 0.125 h time step were conducted using SketchUp-TRNBuild and TRNSYS. Discrete sensitivity analyses and engineering constraints were used to determine the PVT area and cooling tower outlet temperature. Heating demand mainly occurred from November to February, whereas cooling demand was concentrated from June to September. The selected 2452 m2 PVT system supplied direct heating for 34 days, covered 23.05% of the seasonal heating demand, and achieved a storage efficiency of 69.17%. Without a cooling tower, the first-year soil temperature increased by 1.1 °C. With a 26 °C cooling tower outlet temperature, the soil thermal imbalance ratio decreased to 2.4%, and the 15-year soil temperature rise was limited to 0.28 °C. The recommended system required 1.3239 million kWh of net purchased electricity annually, reduced operating costs by approximately CNY 802,800 (USD 118,243) and operational emissions by 2027.8 tCO2-eq per year relative to the baseline, and had a static payback period of 6.4 years. The annual operational emission reduction was linearly extrapolated over a 20-year assessment period under fixed weather, load, equipment performance, and grid emission assumptions, resulting in a scenario-based carbon reduction threshold of 40,556 tCO2-eq. Net life cycle carbon savings would be possible if the additional emissions from construction, equipment replacement, and end-of-life treatment remained below this threshold.
Open AccessSimulation and Performance Analysis of a PVT-Assisted Ground-Source Heat Pump System with Mine Pit Seasonal Thermal Storage for a Cherry Greenhouse: A Case Study
In response to the significant seasonal fluctuations in heating and cooling loads in greenhouses for high-value fruit trees in northern China, as well as issues such as heat accumulation on the ground-source side and high carbon emissions from coal-fired heating, this paper proposes a coupled energy supply system comprising a PVT system, a mine pit seasonal thermal storage unit, a ground-source heat pump and a cooling tower. Taking a 30,000 m2 cherry greenhouse and an existing 15,000 m3 mine pit thermal storage reservoir in Weifang, Shandong Province, as the research objects, annual design-stage simulations with a 0.125 h time step were conducted using SketchUp-TRNBuild and TRNSYS. Discrete sensitivity analyses and engineering constraints were used to determine the PVT area and cooling tower outlet temperature. Heating demand mainly occurred from November to February, whereas cooling demand was concentrated from June to September. The selected 2452 m2 PVT system supplied direct heating for 34 days, covered 23.05% of the seasonal heating demand, and achieved a storage efficiency of 69.17%. Without a cooling tower, the first-year soil temperature increased by 1.1 °C. With a 26 °C cooling tower outlet temperature, the soil thermal imbalance ratio decreased to 2.4%, and the 15-year soil temperature rise was limited to 0.28 °C. The recommended system required 1.3239 million kWh of net purchased electricity annually, reduced operating costs by approximately CNY 802,800 (USD 118,243) and operational emissions by 2027.8 tCO2-eq per year relative to the baseline, and had a static payback period of 6.4 years. The annual operational emission reduction was linearly extrapolated over a 20-year assessment period under fixed weather, load, equipment performance, and grid emission assumptions, resulting in a scenario-based carbon reduction threshold of 40,556 tCO2-eq. Net life cycle carbon savings would be possible if the additional emissions from construction, equipment replacement, and end-of-life treatment remained below this threshold.
- 4 June 2025
- Published by Elsevier in Energy Conversion and Management
- Vol. 341
Techno-economic assessment of zero-carbon cement clinker production process based on limestone hydrogenation
- 4 June 2025
- Published by Elsevier in Energy Conversion and Management
- Vol. 341
Techno-economic assessment of zero-carbon cement clinker production process based on limestone hydrogenation
- Open Access
Comprehensive Control Strategy for Hybrid Energy Storage System Participating in Grid Primary Frequency Regulation
The increasing integration of renewable energy sources has posed significant challenges to grid frequency stability. To maximize the advantages of energy storage in primary frequency regulation, this paper proposes a comprehensive control strategy for a hybrid energy storage system (HESS) based on supercapacitor battery. Firstly, considering the characteristics of the HESS and different control strategies, the battery responds to virtual droop control to reduce frequency deviation, while the supercapacitor responds to inertia control to suppress frequency drops and facilitate frequency recovery. Simultaneously, a reasonable dynamic dead zone is configured to prevent frequent actions of the battery and thermal unit while allowing flexible adjustments according to the load condition. Thirdly, an algebraic S-curve-based adaptive droop coefficient incorporating SOC is proposed, while the inertia coefficient additionally considers load type, enhancing adaptability. Furthermore, to better maintain the battery’s SOC, an improved adaptive recovery strategy within the battery dead zone is proposed, considering both SOC recovery requirements and system frequency deviation constraints. Finally, a simulation validation was conducted in MATLAB/Simulink. Compared to the conventional strategy, the proposed control strategy reduces the frequency drop rate by 17.43% under step disturbance. Under compound disturbances, the RMS of frequency deviation decreases by 13.34%, and the RMS of battery SOC decreases by 68.61%. The economic benefit of this strategy is 3.212 times that of the single energy storage scheme. The results indicate that the proposed strategy effectively alleviates sudden frequency disturbances, suppresses frequency fluctuations, and reduces battery output while maintaining the SOC of both the supercapacitor and the battery, thereby extending the battery lifespan and improving economic performance.
Open AccessComprehensive Control Strategy for Hybrid Energy Storage System Participating in Grid Primary Frequency Regulation
The increasing integration of renewable energy sources has posed significant challenges to grid frequency stability. To maximize the advantages of energy storage in primary frequency regulation, this paper proposes a comprehensive control strategy for a hybrid energy storage system (HESS) based on supercapacitor battery. Firstly, considering the characteristics of the HESS and different control strategies, the battery responds to virtual droop control to reduce frequency deviation, while the supercapacitor responds to inertia control to suppress frequency drops and facilitate frequency recovery. Simultaneously, a reasonable dynamic dead zone is configured to prevent frequent actions of the battery and thermal unit while allowing flexible adjustments according to the load condition. Thirdly, an algebraic S-curve-based adaptive droop coefficient incorporating SOC is proposed, while the inertia coefficient additionally considers load type, enhancing adaptability. Furthermore, to better maintain the battery’s SOC, an improved adaptive recovery strategy within the battery dead zone is proposed, considering both SOC recovery requirements and system frequency deviation constraints. Finally, a simulation validation was conducted in MATLAB/Simulink. Compared to the conventional strategy, the proposed control strategy reduces the frequency drop rate by 17.43% under step disturbance. Under compound disturbances, the RMS of frequency deviation decreases by 13.34%, and the RMS of battery SOC decreases by 68.61%. The economic benefit of this strategy is 3.212 times that of the single energy storage scheme. The results indicate that the proposed strategy effectively alleviates sudden frequency disturbances, suppresses frequency fluctuations, and reduces battery output while maintaining the SOC of both the supercapacitor and the battery, thereby extending the battery lifespan and improving economic performance.
- Open Access
- 19 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 345
Design of Temperature Monitoring and Fault Warning System for Lithium Ternary Battery Case
To enhance the safety of lithium ternary battery cases in new energy vehicles, this study designed a temperature monitoring and fault warning system based on NiCr/NiSi thin-film thermocouples. The system integrates six modules—sensor, amplifier, data acquisition, microprocessor (using the KPCA nonlinear dimensionality reduction algorithm), communication and monitoring, and alarm control—to monitor temperature, voltage, and humidity changes in real time. Multi-level warning thresholds are established (e.g., Level 1: initial temperature 35–55 °C rising to 42–65 °C after 10 min; initial voltage 400–425 V dropping to 398–375 V after 10 min). Experimental results demonstrate that the NiCr/NiSi thermocouple exhibits high sensitivity (average Seebeck coefficient: 41.42 μV/°C) and low repeatability error (1.04%), with a dense and uniform surface structure (roughness: 3.2–5.75 nm). The warning logic, triggered in four levels based on dynamic temperature and voltage changes, achieves an 80% accuracy rate and a low false/missed alarm rate of 4%. Long-term operation tests show stable monitoring deviations (±0.2 °C for temperature and ±0.02 V for voltage over 24 h). The system also adapts to varying humidity environments, with peak sensitivity (41.3 μV/°C) at 60% RH. This research provides a highly reliable solution for battery safety management in new energy vehicles.
- 19 March 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (3) , 345
Open AccessDesign of Temperature Monitoring and Fault Warning System for Lithium Ternary Battery Case
To enhance the safety of lithium ternary battery cases in new energy vehicles, this study designed a temperature monitoring and fault warning system based on NiCr/NiSi thin-film thermocouples. The system integrates six modules—sensor, amplifier, data acquisition, microprocessor (using the KPCA nonlinear dimensionality reduction algorithm), communication and monitoring, and alarm control—to monitor temperature, voltage, and humidity changes in real time. Multi-level warning thresholds are established (e.g., Level 1: initial temperature 35–55 °C rising to 42–65 °C after 10 min; initial voltage 400–425 V dropping to 398–375 V after 10 min). Experimental results demonstrate that the NiCr/NiSi thermocouple exhibits high sensitivity (average Seebeck coefficient: 41.42 μV/°C) and low repeatability error (1.04%), with a dense and uniform surface structure (roughness: 3.2–5.75 nm). The warning logic, triggered in four levels based on dynamic temperature and voltage changes, achieves an 80% accuracy rate and a low false/missed alarm rate of 4%. Long-term operation tests show stable monitoring deviations (±0.2 °C for temperature and ±0.02 V for voltage over 24 h). The system also adapts to varying humidity environments, with peak sensitivity (41.3 μV/°C) at 60% RH. This research provides a highly reliable solution for battery safety management in new energy vehicles.
- Top Cited Papers
- 24 February 2025
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 15 (5) , 4208-4228
Hollow Submicrospherical Ni/Co-Promoted CaO/Ca12Al14O33 for H2 Production from Sorption-Enhanced Water–Gas Shift with In Situ CO2 Conversion via CH4 Reforming of CaCO3
- 24 February 2025
- Published by American Chemical Society (ACS) in ACS Catalysis
- Vol. 15 (5) , 4208-4228
Top Cited PapersHollow Submicrospherical Ni/Co-Promoted CaO/Ca12Al14O33 for H2 Production from Sorption-Enhanced Water–Gas Shift with In Situ CO2 Conversion via CH4 Reforming of CaCO3
- Open Access
- 28 December 2024
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 112, 107213
Dual-frequency ultrasonic-assisted enzymolysis for synthesis of microstructure regulated biomass-derived porous carbon for high-performance supercapacitors
- 28 December 2024
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 112, 107213
Open AccessDual-frequency ultrasonic-assisted enzymolysis for synthesis of microstructure regulated biomass-derived porous carbon for high-performance supercapacitors