Harvey Siy Uy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Harvey Siy Uy has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Pik Sha Chan
Peregrine Eye and Laser Institute, Makati City, Philippines
6 shared publicationsCarolina Tesone-Coelho
Department of Research & Development, InfiniteVision Optics, Strasbourg, France
2 shared publicationsFranz Marie Cruz
Peregrine Eye and Laser Institute, Makati City, Philippines
2 shared publicationsJordan T. Famadico
Peregrine Eye and Laser Institute, Morning Star Center, Makati City, Philippines
2 shared publicationsJorge Lo Yao
Emerge Laboratories
2 shared publicationsJose Carlo M. Artiaga
Moorfields Eye Hospital NHS Foundation Trust, London, UK
2 shared publications
Latest Publications
- Open Access
- 1 March 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-10
Comparison of Clinician Review Time and Confidence with Optical Coherence Tomography Digital versus Print-Based Workflows: A Pilot Observer Study
Background: Optical coherence tomography (OCT) is essential for the management of retinal disease. Digitalization is a potential means of optimizing work practices and improving confidence in treatment decisions. This study compared digital and print/analog image review workflows for OCT images of eyes that underwent intravitreal injection (IVI). Methods: This pilot study was an observer based workflow comparison study. Ten retinal specialists evaluated the OCT image sets of 30 eyes that had undergone IVI treatment. Each reviewer then rendered a simulated treatment decision (treat or not treat) for the most recent image of each set. The amount of time utilized by each specialist to review an image set or image review time (RT), self-rated decision confidence level, and ease-of-use ratings for digital and analog workflows were compared. Inter- and intra-rater variability was determined using exploratory analyses. Results: The mean RT for print and digital workflows were 55.5 ± 37.2 and 28.6 ± 16.5 seconds, respectively (p = 0.007). The use of digital workflow reduced the mean RT by 48.5%. Stratified by disease chronicity, the digital workflow reduced the mean RT for acute, intermediate, and chronic patients by 35.2, 40.2%, and 59.6%, respectively. Treatment decision confidence levels and ease-of-use ratings were significantly higher when using digital workflows than print workflows. The inter-rater reliability was fair to moderate. Conclusion: Digital image review workflows resulted in a shorter RT, higher treatment decision confidence, and enhanced ease of use. Digital workflows may optimize OCT image review efficiency, while also improving decision-making confidence. Gains in RT efficiency were correlated with disease chronicity.
- 1 March 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-10
Open AccessComparison of Clinician Review Time and Confidence with Optical Coherence Tomography Digital versus Print-Based Workflows: A Pilot Observer Study
Background: Optical coherence tomography (OCT) is essential for the management of retinal disease. Digitalization is a potential means of optimizing work practices and improving confidence in treatment decisions. This study compared digital and print/analog image review workflows for OCT images of eyes that underwent intravitreal injection (IVI). Methods: This pilot study was an observer based workflow comparison study. Ten retinal specialists evaluated the OCT image sets of 30 eyes that had undergone IVI treatment. Each reviewer then rendered a simulated treatment decision (treat or not treat) for the most recent image of each set. The amount of time utilized by each specialist to review an image set or image review time (RT), self-rated decision confidence level, and ease-of-use ratings for digital and analog workflows were compared. Inter- and intra-rater variability was determined using exploratory analyses. Results: The mean RT for print and digital workflows were 55.5 ± 37.2 and 28.6 ± 16.5 seconds, respectively (p = 0.007). The use of digital workflow reduced the mean RT by 48.5%. Stratified by disease chronicity, the digital workflow reduced the mean RT for acute, intermediate, and chronic patients by 35.2, 40.2%, and 59.6%, respectively. Treatment decision confidence levels and ease-of-use ratings were significantly higher when using digital workflows than print workflows. The inter-rater reliability was fair to moderate. Conclusion: Digital image review workflows resulted in a shorter RT, higher treatment decision confidence, and enhanced ease of use. Digital workflows may optimize OCT image review efficiency, while also improving decision-making confidence. Gains in RT efficiency were correlated with disease chronicity.
- Open Access
- 24 February 2022
- Published by Springer Nature in BMC Ophthalmology
- Vol. 22 (1) , 1-11
Clinical outcomes of a beveled tip, ultra-high speed, 25-gauge pars plana vitrectomy system
Objective: To report the clinical outcomes of a 25-gauge, beveled-tip, 10,000 cuts-per-minute (cpm) microincisional vitrectomy surgery (MIVS) system.Methods: Prospective case series of eyes undergoing primary pars plana vitrectomy (PPV) for common vitreoretinal indications. Main outcome measures were: rate of achieving surgical objectives, operative times, number of surgical steps, use of ancillary instruments, corrected distance visual acuity (CDVA), and adverse events (AE).Results: The surgical objectives were achieved in all eyes. Mean total operative time (TOT), core, shave and total vitrectomy times were 1891 ± 890, 204 ± 120, 330 ± 320, 534 ± 389 s, respectively. Mean number of surgical steps was 4.3 ± 1.5. Mean number of ancillary instruments used was 4.5 ± 1.9. Mean CDVA improved by 0.53 ± 0.56 logMAR units (P < 0.001) 3 months postoperatively. AE included elevated IOP (8%), hypotony (6%), and re-detachment (2%). Majority (82%) had no postoperative discomfort. The number of surgical steps demonstrated a positive correlation with TOT (p < 0.05), number of ancillary instruments used (p < 0.05), and postoperative Day 1 IOP (p < 0.05). The number of times ancillary instrumentation was used demonstrated a positive correlation with TOT (p < 0.05).Conclusion: Beveled-tip, 10,000 cpm MIVS system effectively and safely performs common VR procedures of varying complexity and may reduce operative times and use of ancillary instrumentation.
- 24 February 2022
- Published by Springer Nature in BMC Ophthalmology
- Vol. 22 (1) , 1-11
Open AccessClinical outcomes of a beveled tip, ultra-high speed, 25-gauge pars plana vitrectomy system
Objective: To report the clinical outcomes of a 25-gauge, beveled-tip, 10,000 cuts-per-minute (cpm) microincisional vitrectomy surgery (MIVS) system.Methods: Prospective case series of eyes undergoing primary pars plana vitrectomy (PPV) for common vitreoretinal indications. Main outcome measures were: rate of achieving surgical objectives, operative times, number of surgical steps, use of ancillary instruments, corrected distance visual acuity (CDVA), and adverse events (AE).Results: The surgical objectives were achieved in all eyes. Mean total operative time (TOT), core, shave and total vitrectomy times were 1891 ± 890, 204 ± 120, 330 ± 320, 534 ± 389 s, respectively. Mean number of surgical steps was 4.3 ± 1.5. Mean number of ancillary instruments used was 4.5 ± 1.9. Mean CDVA improved by 0.53 ± 0.56 logMAR units (P < 0.001) 3 months postoperatively. AE included elevated IOP (8%), hypotony (6%), and re-detachment (2%). Majority (82%) had no postoperative discomfort. The number of surgical steps demonstrated a positive correlation with TOT (p < 0.05), number of ancillary instruments used (p < 0.05), and postoperative Day 1 IOP (p < 0.05). The number of times ancillary instrumentation was used demonstrated a positive correlation with TOT (p < 0.05).Conclusion: Beveled-tip, 10,000 cpm MIVS system effectively and safely performs common VR procedures of varying complexity and may reduce operative times and use of ancillary instrumentation.
- Open Access
- 1 October 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 4097-4108
Multicenter, Prospective, Randomized Study of Dexamethasone Intravitreal Implant in Patients with Center-Involved Diabetic Macular Edema in the Asia-Pacific Region
Purpose: To evaluate the safety and efficacy of dexamethasone intravitreal implant 0.7 mg (DEX) compared with laser photocoagulation in patients with diabetic macular edema (DME). Patients and Methods: This Phase 3, multicenter, randomized, efficacy evaluator–masked, parallel-group, 12-month clinical study enrolled adults in China and the Philippines with reduced visual acuity secondary to fovea-involved DME in the study eye. Participants were randomized 1:1 to study eye treatment with laser photocoagulation every 3 months as needed (n = 139) or DEX every 5 months (n = 145). The main efficacy measures were best-corrected visual acuity (BCVA), central retinal thickness (CRT), and leakage area. The primary endpoint was the average change in BCVA from baseline over 12 months (area-under-the-curve method). Preplanned subgroup analyses evaluated outcomes in Chinese patients. Results: Mean average change in BCVA from baseline during the study (letters) was 4.3 with DEX (n = 145) versus 1.4 with laser (n = 127) overall (P = 0.001) and 4.6 with DEX (n = 129) versus 0.6 with laser (n = 113) in Chinese patients (P < 0.001). At Month 12, mean change in CRT from baseline was − 209.5 μm with DEX versus − 120.3 μm with laser (P < 0.001) and mean change in total leakage area from baseline was − 8.367 mm2 with DEX versus − 0.637 mm2 with laser (P < 0.001). The most common treatment-emergent adverse events in the DEX group were increased intraocular pressure and cataract. Conclusion: DEX administered every 5 months provided significantly greater improvement in BCVA, CRT, and total leakage area compared with laser treatment. DEX demonstrated an acceptable safety profile, consistent with an intraocular corticosteroid, and similar to that reported in completed global registration studies.
- 1 October 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 4097-4108
Open AccessMulticenter, Prospective, Randomized Study of Dexamethasone Intravitreal Implant in Patients with Center-Involved Diabetic Macular Edema in the Asia-Pacific Region
Purpose: To evaluate the safety and efficacy of dexamethasone intravitreal implant 0.7 mg (DEX) compared with laser photocoagulation in patients with diabetic macular edema (DME). Patients and Methods: This Phase 3, multicenter, randomized, efficacy evaluator–masked, parallel-group, 12-month clinical study enrolled adults in China and the Philippines with reduced visual acuity secondary to fovea-involved DME in the study eye. Participants were randomized 1:1 to study eye treatment with laser photocoagulation every 3 months as needed (n = 139) or DEX every 5 months (n = 145). The main efficacy measures were best-corrected visual acuity (BCVA), central retinal thickness (CRT), and leakage area. The primary endpoint was the average change in BCVA from baseline over 12 months (area-under-the-curve method). Preplanned subgroup analyses evaluated outcomes in Chinese patients. Results: Mean average change in BCVA from baseline during the study (letters) was 4.3 with DEX (n = 145) versus 1.4 with laser (n = 127) overall (P = 0.001) and 4.6 with DEX (n = 129) versus 0.6 with laser (n = 113) in Chinese patients (P < 0.001). At Month 12, mean change in CRT from baseline was − 209.5 μm with DEX versus − 120.3 μm with laser (P < 0.001) and mean change in total leakage area from baseline was − 8.367 mm2 with DEX versus − 0.637 mm2 with laser (P < 0.001). The most common treatment-emergent adverse events in the DEX group were increased intraocular pressure and cataract. Conclusion: DEX administered every 5 months provided significantly greater improvement in BCVA, CRT, and total leakage area compared with laser treatment. DEX demonstrated an acceptable safety profile, consistent with an intraocular corticosteroid, and similar to that reported in completed global registration studies.
- Open Access
- 13 July 2021
- Published by Springer Nature in Research Square
Clinical Outcomes Of Beveled Tip, Ultra-High Speed, 25-Gauge Pars Plana Vitrectomy System
OBJECTIVE To report clinical outcomes of a 25-gauge, beveled-tip, 10000 cuts-per-minute (cpm) microincisional vitrectomy surgery (MIVS) system. METHODS Prospective case series of eyes undergoing primary pars plana vitrectomy (PPV) for common indications. Main outcome measures were: rate of achieving surgical objectives, operative time, number of surgical steps, use of ancillary instruments, corrected distance visual acuity (CDVA), and adverse events (AE). RESULTS Surgical objectives were achieved in all eyes. Mean total operative, core, shave and total vitrectomy times were 1891 ± 890, 204 ± 120, 330 ± 320, 534 ± 389 seconds, respectively. Mean number of surgical steps was 4.3 ± 1.5. Mean number of ancillary instruments used was 4.5 ± 1.9. Mean CDVA improved by 0.53 ± 0.56 logMAR units (P < 0.001) after 3 months. Postoperative AE included elevated IOP (8%), hypotony (6%), and re-detachment (2%). Majority (82%) had no postoperative discomfort. CONCLUSION Beveled-tip, 10000 cpm MIVS system effectively and safely performs common vitreoretinal procedures and may reduce operative time and ancillary instrumentation.
- 13 July 2021
- Published by Springer Nature in Research Square
Open AccessClinical Outcomes Of Beveled Tip, Ultra-High Speed, 25-Gauge Pars Plana Vitrectomy System
OBJECTIVE To report clinical outcomes of a 25-gauge, beveled-tip, 10000 cuts-per-minute (cpm) microincisional vitrectomy surgery (MIVS) system. METHODS Prospective case series of eyes undergoing primary pars plana vitrectomy (PPV) for common indications. Main outcome measures were: rate of achieving surgical objectives, operative time, number of surgical steps, use of ancillary instruments, corrected distance visual acuity (CDVA), and adverse events (AE). RESULTS Surgical objectives were achieved in all eyes. Mean total operative, core, shave and total vitrectomy times were 1891 ± 890, 204 ± 120, 330 ± 320, 534 ± 389 seconds, respectively. Mean number of surgical steps was 4.3 ± 1.5. Mean number of ancillary instruments used was 4.5 ± 1.9. Mean CDVA improved by 0.53 ± 0.56 logMAR units (P < 0.001) after 3 months. Postoperative AE included elevated IOP (8%), hypotony (6%), and re-detachment (2%). Majority (82%) had no postoperative discomfort. CONCLUSION Beveled-tip, 10000 cpm MIVS system effectively and safely performs common vitreoretinal procedures and may reduce operative time and ancillary instrumentation.
- Open Access
- 1 June 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 2383-2389
Comparison of Two Different Intravitreal Injection Techniques
Objective: To compare the effectiveness, procedure time and safety outcomes of two different intravitreal injections (IVI) techniques. Methods: This was a prospective, single-center, randomized clinical trial of 200 adult eyes receiving intravitreal medications for various indications. Eyes were assigned (1:1) to undergo IVI using either an intravitreal injection guide (IIG) (n= 100) or conventional dual blade speculum plus surgical caliper (DBS) (n=100). All IVI were administered using a 30-gauge needle placed 4 mm posterior to the inferior limbus. The main outcome measures were rate of successful IVI administration, procedure time (seconds) as measured by a stopwatch from application to removal of IIG or DBS, patient preference for IVI technique and adverse events. Results: The two groups were similar in terms of mean age (P=0.398), laterality (P=0.671), indication for treatment (P=0.175) and medication type (P=0.489). All IVI procedures were successfully completed in both groups. The mean procedure time was shorter using the IIG (9.94 ± 2.87 seconds) versus DBS (21.85 ± 7.25 seconds) technique (P ≤ 0.01). The incidence of post-injection subconjunctival hemorrhage was higher when the DBS was applied (OR = 2.35, 95% CI = 1.22– 4.53). Patients with previous history of IVI preferred the IIG over the DBS. No other injection-related adverse events were observed in both groups. Conclusion: DBS and IIG techniques are similarly effective and safe for the administration of intravitreal medications. The IIG appears to significantly reduce procedure time, be associated with a lower incidence of subconjunctival hemorrhage and engender better patient acceptance. Clinical Trial Registration: ClinicalTrials.gov (NCT04455399).
- 1 June 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 2383-2389
Open AccessComparison of Two Different Intravitreal Injection Techniques
Objective: To compare the effectiveness, procedure time and safety outcomes of two different intravitreal injections (IVI) techniques. Methods: This was a prospective, single-center, randomized clinical trial of 200 adult eyes receiving intravitreal medications for various indications. Eyes were assigned (1:1) to undergo IVI using either an intravitreal injection guide (IIG) (n= 100) or conventional dual blade speculum plus surgical caliper (DBS) (n=100). All IVI were administered using a 30-gauge needle placed 4 mm posterior to the inferior limbus. The main outcome measures were rate of successful IVI administration, procedure time (seconds) as measured by a stopwatch from application to removal of IIG or DBS, patient preference for IVI technique and adverse events. Results: The two groups were similar in terms of mean age (P=0.398), laterality (P=0.671), indication for treatment (P=0.175) and medication type (P=0.489). All IVI procedures were successfully completed in both groups. The mean procedure time was shorter using the IIG (9.94 ± 2.87 seconds) versus DBS (21.85 ± 7.25 seconds) technique (P ≤ 0.01). The incidence of post-injection subconjunctival hemorrhage was higher when the DBS was applied (OR = 2.35, 95% CI = 1.22– 4.53). Patients with previous history of IVI preferred the IIG over the DBS. No other injection-related adverse events were observed in both groups. Conclusion: DBS and IIG techniques are similarly effective and safe for the administration of intravitreal medications. The IIG appears to significantly reduce procedure time, be associated with a lower incidence of subconjunctival hemorrhage and engender better patient acceptance. Clinical Trial Registration: ClinicalTrials.gov (NCT04455399).
- 26 October 2019
- Published by Springer Nature
- p. 645-649
Multiple Myeloma
- Open Access
- 1 September 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 1897-1907
Rotational stability of a new multicomponent intraocular lens
Purpose: To evaluate the rotational stability of the Precisight multicomponent intraocular lens (MCIOL) following primary implantation and after enhancement procedures. Patients and methods: Prospective, single-center study of eyes that underwent routine cataract surgery with implantation of a non-toric MCIOL, (Precisight, InfiniteVision, Optics, Strasbourg, France). The axis of the MCIOL was measured with a line bisecting the two dialing holes in the front lens. Intraoperative orientation was determined using a digital surgical guidance system while the postoperative orientation was determined using slit-lamp imaging. Two populations were analyzed: eyes that only underwent cataract surgery (PRIM) and eyes that also underwent enhancement (ENH), consisting of surgical front optic exchange. Both populations had 3 observation visits: first implantation (P-Op); 3 months (3mo) and 6 months (6mo) after primary surgery. The ENH group had an additional fourth visit that corresponded to the enhancement surgery (E-Op). The main outcome measure was mean absolute change in MCIOL orientation (degrees). The effects of axial length (AL) and anterior chamber depth (ACD) on IOL rotational stability were examined. Results: Thirty-three eyes received MCIOL of which 29 had usable orientation images. Of these, 12 were in the PRIM group and 17 underwent ENH. Regarding the mean absolute rotation, among PRIM eyes, P-Op to 3mo was 3.03±2.45 degrees; P-Op to 6mo, 2.28±1.54 degrees; and 3–6mo, 2.37±1.56 degrees. Among the ENH eyes, P-Op to 3mo was 3.09±1.68; E-Op to 6mo, 2.71±3.30 and P-Op to 6mo, 3.62±3.42. There were no significant differences in the IOL rotation. There were no statistical differences in rotational stability between the ENH and PRIM groups. There was no correlation between IOL rotation and AL or ACD. Conclusion: Precisight appears to be rotationally stable. The enhancement procedure does not affect rotational stability.
- 1 September 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 1897-1907
Open AccessRotational stability of a new multicomponent intraocular lens
Purpose: To evaluate the rotational stability of the Precisight multicomponent intraocular lens (MCIOL) following primary implantation and after enhancement procedures. Patients and methods: Prospective, single-center study of eyes that underwent routine cataract surgery with implantation of a non-toric MCIOL, (Precisight, InfiniteVision, Optics, Strasbourg, France). The axis of the MCIOL was measured with a line bisecting the two dialing holes in the front lens. Intraoperative orientation was determined using a digital surgical guidance system while the postoperative orientation was determined using slit-lamp imaging. Two populations were analyzed: eyes that only underwent cataract surgery (PRIM) and eyes that also underwent enhancement (ENH), consisting of surgical front optic exchange. Both populations had 3 observation visits: first implantation (P-Op); 3 months (3mo) and 6 months (6mo) after primary surgery. The ENH group had an additional fourth visit that corresponded to the enhancement surgery (E-Op). The main outcome measure was mean absolute change in MCIOL orientation (degrees). The effects of axial length (AL) and anterior chamber depth (ACD) on IOL rotational stability were examined. Results: Thirty-three eyes received MCIOL of which 29 had usable orientation images. Of these, 12 were in the PRIM group and 17 underwent ENH. Regarding the mean absolute rotation, among PRIM eyes, P-Op to 3mo was 3.03±2.45 degrees; P-Op to 6mo, 2.28±1.54 degrees; and 3–6mo, 2.37±1.56 degrees. Among the ENH eyes, P-Op to 3mo was 3.09±1.68; E-Op to 6mo, 2.71±3.30 and P-Op to 6mo, 3.62±3.42. There were no significant differences in the IOL rotation. There were no statistical differences in rotational stability between the ENH and PRIM groups. There was no correlation between IOL rotation and AL or ACD. Conclusion: Precisight appears to be rotationally stable. The enhancement procedure does not affect rotational stability.
- 4 March 2019
- Published by Springer Nature in International Ophthalmology
- Vol. 39 (11) , 2459-2465
Comparison of surgical parameters using different lens fragmentation patterns in eyes undergoing laser-assisted cataract surgery
To compare surgical parameters among eyes undergoing laser-assisted cataract surgery (LACS) using different lens fragmentation patterns (LFP).
- 4 March 2019
- Published by Springer Nature in International Ophthalmology
- Vol. 39 (11) , 2459-2465
Comparison of surgical parameters using different lens fragmentation patterns in eyes undergoing laser-assisted cataract surgery
To compare surgical parameters among eyes undergoing laser-assisted cataract surgery (LACS) using different lens fragmentation patterns (LFP).
- Open Access
- 1 January 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 107-114
Enhancement-procedure outcomes in patients implanted with the Precisight multicomponent intraocular lens
Purpose: Eyes that have undergone phacoemulsification with implantation of a multicomponent intraocular lens (MCIOL) may further undergo an enhancement procedure for correction of residual refractive errors. The enhancement procedure is accomplished by exchanging the front lens used in the primary surgery with another lens containing the correct dioptric power. We evaluated the efficacy and safety of enhancement procedures among eyes that received an MCIOL. Methods: A total of 25 eyes that had undergone phacoemulsification with implantation of an MCIOL were found to have a residual error of refraction (spherical equivalent ≥0.75 D) 3 months after primary cataract surgery, and underwent further enhancement surgery. The main study outcomes were uncorrected and corrected distance visual acuity, subjective refraction, anterior-chamber depth, pachymetry, and endothelial cell count. Results: There was a statistically significant improvement in uncorrected distance visual acuity of approximately two lines after enhancement surgery (0.20±0.20–0.02±0.08 logMAR, PPPConclusion: The MCIOL-enhancement procedure demonstrates statistical and clinical improvement in uncorrected distance visual acuity and correction of postoperative refractive errors. The Precisight IOL may be a useful choice for patients with high risk of having significant residual refractive errors after primary cataract surgery.
- 1 January 2019
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 107-114
Open AccessEnhancement-procedure outcomes in patients implanted with the Precisight multicomponent intraocular lens
Purpose: Eyes that have undergone phacoemulsification with implantation of a multicomponent intraocular lens (MCIOL) may further undergo an enhancement procedure for correction of residual refractive errors. The enhancement procedure is accomplished by exchanging the front lens used in the primary surgery with another lens containing the correct dioptric power. We evaluated the efficacy and safety of enhancement procedures among eyes that received an MCIOL. Methods: A total of 25 eyes that had undergone phacoemulsification with implantation of an MCIOL were found to have a residual error of refraction (spherical equivalent ≥0.75 D) 3 months after primary cataract surgery, and underwent further enhancement surgery. The main study outcomes were uncorrected and corrected distance visual acuity, subjective refraction, anterior-chamber depth, pachymetry, and endothelial cell count. Results: There was a statistically significant improvement in uncorrected distance visual acuity of approximately two lines after enhancement surgery (0.20±0.20–0.02±0.08 logMAR, PPPConclusion: The MCIOL-enhancement procedure demonstrates statistical and clinical improvement in uncorrected distance visual acuity and correction of postoperative refractive errors. The Precisight IOL may be a useful choice for patients with high risk of having significant residual refractive errors after primary cataract surgery.
- 25 August 2016
- Published by Springer Nature
- p. 1-5
Multiple Myeloma