Oscar Holmström
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Oscar Holmström has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Johan Lundin
Department of Global Public Health, Karolinska Institutet, Stockholm, Sweden
5 shared publications - Nina Linder
Institute for Molecular Medicine Finland, HiLIFE, University of Helsinki, Helsinki, Finland
5 shared publications Antti Suutala
Affiliation Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
3 shared publicationsHannu Moilanen
Affiliation Center of Microscopy and Nanotechnology, University of Oulu, Oulu, Finland
3 shared publicationsMikael Lundin
Affiliation Institute for Molecular Medicine Finland (FIMM), University of Helsinki, Helsinki, Finland
3 shared publications- Mikael Lundin
Institute for Molecular Medicine Finland (FIMM), P.O. Box 20, FI-00014 University of Helsinki, Helsinki, Finland
3 shared publications
Latest Publications
- Open Access
- 17 November 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0242355
A novel deep learning-based point-of-care diagnostic method for detecting Plasmodium falciparum with fluorescence digital microscopy
Background: Malaria remains a major global health problem with a need for improved field-usable diagnostic tests. We have developed a portable, low-cost digital microscope scanner, capable of both brightfield and fluorescence imaging. Here, we used the instrument to digitize blood smears, and applied deep learning (DL) algorithms to detectPlasmodium falciparumparasites.Methods: Thin blood smears (n= 125) were collected from patients with microscopy-confirmedP.falciparuminfections in rural Tanzania, prior to and after initiation of artemisinin-based combination therapy. The samples were stained using the 4′,6-diamidino-2-phenylindole fluorogen and digitized using the prototype microscope scanner. Two DL algorithms were trained to detect malaria parasites in the samples, and results compared to the visual assessment of both the digitized samples, and the Giemsa-stained thick smears.Results: Detection ofP.falciparumparasites in the digitized thin blood smears was possible both by visual assessment and by DL-based analysis with a strong correlation in results (r = 0.99, p < 0.01). A moderately strong correlation was observed between the DL-based thin smear analysis and the visual thick smear-analysis (r = 0.74, p < 0.01). Low levels of parasites were detected by DL-based analysis on day three following treatment initiation, but a small number of fluorescent signals were detected also in microscopy-negative samples.Conclusion: Quantification ofP.falciparumparasites in DAPI-stained thin smears is feasible using DL-supported, point-of-care digital microscopy, with a high correlation to visual assessment of samples. Fluorescent signals from artefacts in samples with low infection levels represented the main challenge for the digital analysis, thus highlighting the importance of minimizing sample contaminations. The proposed method could support malaria diagnostics and monitoring of treatment response through automated quantification of parasitaemia and is likely to be applicable also for diagnostics of otherPlasmodiumspecies and other infectious diseases.
- 17 November 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0242355
Open AccessA novel deep learning-based point-of-care diagnostic method for detecting Plasmodium falciparum with fluorescence digital microscopy
Background: Malaria remains a major global health problem with a need for improved field-usable diagnostic tests. We have developed a portable, low-cost digital microscope scanner, capable of both brightfield and fluorescence imaging. Here, we used the instrument to digitize blood smears, and applied deep learning (DL) algorithms to detectPlasmodium falciparumparasites.Methods: Thin blood smears (n= 125) were collected from patients with microscopy-confirmedP.falciparuminfections in rural Tanzania, prior to and after initiation of artemisinin-based combination therapy. The samples were stained using the 4′,6-diamidino-2-phenylindole fluorogen and digitized using the prototype microscope scanner. Two DL algorithms were trained to detect malaria parasites in the samples, and results compared to the visual assessment of both the digitized samples, and the Giemsa-stained thick smears.Results: Detection ofP.falciparumparasites in the digitized thin blood smears was possible both by visual assessment and by DL-based analysis with a strong correlation in results (r = 0.99, p < 0.01). A moderately strong correlation was observed between the DL-based thin smear analysis and the visual thick smear-analysis (r = 0.74, p < 0.01). Low levels of parasites were detected by DL-based analysis on day three following treatment initiation, but a small number of fluorescent signals were detected also in microscopy-negative samples.Conclusion: Quantification ofP.falciparumparasites in DAPI-stained thin smears is feasible using DL-supported, point-of-care digital microscopy, with a high correlation to visual assessment of samples. Fluorescent signals from artefacts in samples with low infection levels represented the main challenge for the digital analysis, thus highlighting the importance of minimizing sample contaminations. The proposed method could support malaria diagnostics and monitoring of treatment response through automated quantification of parasitaemia and is likely to be applicable also for diagnostics of otherPlasmodiumspecies and other infectious diseases.
- Open Access
Point-of-care digital cytology with artificial intelligence for cervical cancer screening at a peripheral clinic in Kenya
Cervical cancer is highly preventable but remains a common and deadly cancer in areas without screening programmes. Pap smear analysis is the most commonly used screening method but is labour-intensive, subjective and requires access to medical experts. We developed a diagnostic system in which microscopy samples are digitized at the point-of-care (POC) and analysed by a cloud-based deep-learning system (DLS) and evaluated the system for the detection of cervical cell atypia in Pap smears at a peripheral clinic in Kenya. A total of 740 conventional Pap smears were collected, digitized with a portable slide scanner and uploaded over mobile networks to a cloud server for training and validation of the system. In total, 16,133 manually-annotated image regions where used for training of the DLS. The DLS achieved a high average sensitivity (97.85%; 95% confidence interval (CI) 83.95—99.75%) and area under the curve (AUCs) (0.95) for the detection of cervical-cellular atypia, compared to the pathologist assessment of digital and physical slides. Specificity was higher for high-grade atypia (95.9%; 95% CI 94.9—97.6%) than for low-grade atypia (84.2%; 95% CI 79.9—87.9%). Negative predictive values were high (99.3-100%), and no samples classified as high grade by manual sample analysis had false-negative assessments by the DLS. The study shows that advanced digital microscopy diagnostics supported by machine learning algorithms is implementable in rural, resource-constrained areas, and can achieve a diagnostic accuracy close to the level of highly trained experts. Summary box: What is already known?: • Cervical cancer can be prevented with Pap smear screening, but manual sample analysis is labor-intensive, subjective and not widely-available in regions with the highest disease prevalence • Novel digital methods, such as image-based artificial intelligence (AI), show promise for facilitated analysis of microscopy samples • Digital methods are typically limited to high-end laboratories, due to the requirements for advanced equipment and supportive digital infrastructure What are the new findings?: • A point-of-care diagnostic system where samples are digitized with a portable slide scanner and analyzed using a cloud-based AI model can be implemented in rural settings and utilized to automatically interpret Pap smears and identify potentially precancerous samples with similar accuracy as a pathologist specialized in reading Pap smears. What do the new findings imply?: • The results demonstrate how advanced digital methods, such as AI-based digital microscopy, can be implemented in rural, resource-limited areas, and used for analysis of microscopy samples, such as Pap smears. • This technology shows promise as a novel method for digital microscopy diagnostics, which can be implemented in rural settings, and could be of particular value in areas lacking cytotechnicians and pathologists.
Open AccessPoint-of-care digital cytology with artificial intelligence for cervical cancer screening at a peripheral clinic in Kenya
Cervical cancer is highly preventable but remains a common and deadly cancer in areas without screening programmes. Pap smear analysis is the most commonly used screening method but is labour-intensive, subjective and requires access to medical experts. We developed a diagnostic system in which microscopy samples are digitized at the point-of-care (POC) and analysed by a cloud-based deep-learning system (DLS) and evaluated the system for the detection of cervical cell atypia in Pap smears at a peripheral clinic in Kenya. A total of 740 conventional Pap smears were collected, digitized with a portable slide scanner and uploaded over mobile networks to a cloud server for training and validation of the system. In total, 16,133 manually-annotated image regions where used for training of the DLS. The DLS achieved a high average sensitivity (97.85%; 95% confidence interval (CI) 83.95—99.75%) and area under the curve (AUCs) (0.95) for the detection of cervical-cellular atypia, compared to the pathologist assessment of digital and physical slides. Specificity was higher for high-grade atypia (95.9%; 95% CI 94.9—97.6%) than for low-grade atypia (84.2%; 95% CI 79.9—87.9%). Negative predictive values were high (99.3-100%), and no samples classified as high grade by manual sample analysis had false-negative assessments by the DLS. The study shows that advanced digital microscopy diagnostics supported by machine learning algorithms is implementable in rural, resource-constrained areas, and can achieve a diagnostic accuracy close to the level of highly trained experts. Summary box: What is already known?: • Cervical cancer can be prevented with Pap smear screening, but manual sample analysis is labor-intensive, subjective and not widely-available in regions with the highest disease prevalence • Novel digital methods, such as image-based artificial intelligence (AI), show promise for facilitated analysis of microscopy samples • Digital methods are typically limited to high-end laboratories, due to the requirements for advanced equipment and supportive digital infrastructure What are the new findings?: • A point-of-care diagnostic system where samples are digitized with a portable slide scanner and analyzed using a cloud-based AI model can be implemented in rural settings and utilized to automatically interpret Pap smears and identify potentially precancerous samples with similar accuracy as a pathologist specialized in reading Pap smears. What do the new findings imply?: • The results demonstrate how advanced digital methods, such as AI-based digital microscopy, can be implemented in rural, resource-limited areas, and used for analysis of microscopy samples, such as Pap smears. • This technology shows promise as a novel method for digital microscopy diagnostics, which can be implemented in rural settings, and could be of particular value in areas lacking cytotechnicians and pathologists.
- Open Access
A novel deep learning-based point-of-care diagnostic method for detecting Plasmodium falciparum with fluorescence digital microscopy
Background: Malaria remains a major global health problem with a need for improved field-usable diagnostic tests. We have developed a portable, low-cost digital microscope scanner, capable of both brightfield and fluorescence imaging. Here, we used the instrument to digitize blood smears, and applied deep learning (DL) algorithms to detect Plasmodium falciparum parasites. Methods: Thin blood smears (n = 125) were collected from patients with microscopy-confirmed P. falciparum infections in rural Tanzania, prior to and after initiation of artemisinin-based combination therapy. The samples were stained using the 4’,6-diamidino-2-phenylindole fluorogen and digitized using the prototype microscope scanner. Two DL algorithms were trained to detect malaria parasites in the samples, and results compared to the visual assessment of both the digitized samples, and the Giemsa-stained thick smears. Results: Detection of P. falciparum parasites in the digitized thin blood smears was possible both by visual assessment and by DL-based analysis with a strong correlation in results (r = 0.99, p < 0.01). A moderately strong correlation was observed between the DL-based thin smear analysis and the visual thick smear-analysis (r = 0.74, p < 0.01). Low levels of parasites were detected by DL-based analysis on day three following treatment initiation, but a small number of fluorescent signals were detected also in microscopy-negative samples. Conclusion: Quantification of P. falciparum parasites in DAPI-stained thin smears is feasible using DL-supported, point-of-care digital microscopy, with a high correlation to visual assessment of samples. Fluorescent signals from artefacts in samples with low infection levels represented the main challenge for the digital analysis, thus highlighting the importance of minimizing sample contaminations. The proposed method could support malaria diagnostics and monitoring of treatment response through automated quantification of parasitaemia and is likely to be applicable also for diagnostics of other Plasmodium species and other infectious diseases.
Open AccessA novel deep learning-based point-of-care diagnostic method for detecting Plasmodium falciparum with fluorescence digital microscopy
Background: Malaria remains a major global health problem with a need for improved field-usable diagnostic tests. We have developed a portable, low-cost digital microscope scanner, capable of both brightfield and fluorescence imaging. Here, we used the instrument to digitize blood smears, and applied deep learning (DL) algorithms to detect Plasmodium falciparum parasites. Methods: Thin blood smears (n = 125) were collected from patients with microscopy-confirmed P. falciparum infections in rural Tanzania, prior to and after initiation of artemisinin-based combination therapy. The samples were stained using the 4’,6-diamidino-2-phenylindole fluorogen and digitized using the prototype microscope scanner. Two DL algorithms were trained to detect malaria parasites in the samples, and results compared to the visual assessment of both the digitized samples, and the Giemsa-stained thick smears. Results: Detection of P. falciparum parasites in the digitized thin blood smears was possible both by visual assessment and by DL-based analysis with a strong correlation in results (r = 0.99, p < 0.01). A moderately strong correlation was observed between the DL-based thin smear analysis and the visual thick smear-analysis (r = 0.74, p < 0.01). Low levels of parasites were detected by DL-based analysis on day three following treatment initiation, but a small number of fluorescent signals were detected also in microscopy-negative samples. Conclusion: Quantification of P. falciparum parasites in DAPI-stained thin smears is feasible using DL-supported, point-of-care digital microscopy, with a high correlation to visual assessment of samples. Fluorescent signals from artefacts in samples with low infection levels represented the main challenge for the digital analysis, thus highlighting the importance of minimizing sample contaminations. The proposed method could support malaria diagnostics and monitoring of treatment response through automated quantification of parasitaemia and is likely to be applicable also for diagnostics of other Plasmodium species and other infectious diseases.
- Open Access
- 19 March 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (3) , e0208366
Detection of breast cancer lymph node metastases in frozen sections with a point-of-care low-cost microscope scanner
Detection of lymph node metastases is essential in breast cancer diagnostics and staging, affecting treatment and prognosis. Intraoperative microscopy analysis of sentinel lymph node frozen sections is standard for detection of axillary metastases but requires access to a pathologist for sample analysis. Remote analysis of digitized samples is an alternative solution but is limited by the requirement for high-end slide scanning equipment. To determine whether the image quality achievable with a low-cost, miniature digital microscope scanner is sufficient for detection of metastases in breast cancer lymph node frozen sections. Lymph node frozen sections from 79 breast cancer patients were digitized using a prototype miniature microscope scanner and a high-end slide scanner. Images were independently reviewed by two pathologists and results compared between devices with conventional light microscopy analysis as ground truth. Detection of metastases in the images acquired with the miniature scanner yielded an overall sensitivity of 91% and specificity of 99% and showed strong agreement when compared to light microscopy (k = 0.91). Strong agreement was also observed when results were compared to results from the high-end slide scanner (k = 0.94). A majority of discrepant cases were micrometastases and sections of which no anticytokeratin staining was available. Accuracy of detection of metastatic cells in breast cancer sentinel lymph node frozen sections by visual analysis of samples digitized using low-cost, point-of-care microscopy is comparable to analysis of digital samples scanned using a high-end, whole slide scanner. This technique could potentially provide a workflow for digital diagnostics in resource-limited settings, facilitate sample analysis at the point-of-care and reduce the need for trained experts on-site during surgical procedures.
- 19 March 2019
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 14 (3) , e0208366
Open AccessDetection of breast cancer lymph node metastases in frozen sections with a point-of-care low-cost microscope scanner
Detection of lymph node metastases is essential in breast cancer diagnostics and staging, affecting treatment and prognosis. Intraoperative microscopy analysis of sentinel lymph node frozen sections is standard for detection of axillary metastases but requires access to a pathologist for sample analysis. Remote analysis of digitized samples is an alternative solution but is limited by the requirement for high-end slide scanning equipment. To determine whether the image quality achievable with a low-cost, miniature digital microscope scanner is sufficient for detection of metastases in breast cancer lymph node frozen sections. Lymph node frozen sections from 79 breast cancer patients were digitized using a prototype miniature microscope scanner and a high-end slide scanner. Images were independently reviewed by two pathologists and results compared between devices with conventional light microscopy analysis as ground truth. Detection of metastases in the images acquired with the miniature scanner yielded an overall sensitivity of 91% and specificity of 99% and showed strong agreement when compared to light microscopy (k = 0.91). Strong agreement was also observed when results were compared to results from the high-end slide scanner (k = 0.94). A majority of discrepant cases were micrometastases and sections of which no anticytokeratin staining was available. Accuracy of detection of metastatic cells in breast cancer sentinel lymph node frozen sections by visual analysis of samples digitized using low-cost, point-of-care microscopy is comparable to analysis of digital samples scanned using a high-end, whole slide scanner. This technique could potentially provide a workflow for digital diagnostics in resource-limited settings, facilitate sample analysis at the point-of-care and reduce the need for trained experts on-site during surgical procedures.
- Open Access
Detection of breast cancer lymph node metastases in frozen sections with a point-of-care low-cost microscope scanner
Background: Detection of lymph node metastases is essential in breast cancer diagnostics and staging, affecting treatment and prognosis. Intraoperative microscopy analysis of sentinel lymph node frozen sections is standard for detection of axillary metastases, but requires access to a pathologist for sample analysis. Remote analysis of digitized samples is an alternative solution, but is limited by the requirement for high-end slide scanning equipment. Objective: To determine whether the image quality achievable with a low-cost, miniature digital microscope scanner is sufficient for detection of metastases in breast cancer lymph node frozen sections. Methods: Lymph node frozen sections from 79 breast cancer patients were digitized using a prototype miniature microscope scanner and a high-end slide scanner. Images were independently reviewed by two pathologists and results compared between devices with conventional light microscopy analysis as ground truth. Results: Detection of metastases in the images acquired with the miniature scanner yielded an overall sensitivity of 91 % and specificity of 99 % and showed strong agreement when compared to light microscopy ( k = 0.91). Strong agreement was also observed when results were compared to results from the high-end slide scanner ( k = 0.94). A majority of discrepant cases were micrometastases and sections of which no anticytokeratin staining was available. Conclusion: Accuracy of detection of metastatic cells in breast cancer sentinel lymph node frozen sections by visual analysis of samples digitized using low-cost, point-of-care microscopy is comparable to analysis of digital samples scanned using a high-end, whole slide scanner. This technique could potentially provide a workflow for digital diagnostics in resource-limited settings, facilitate sample analysis at the point-of-care and reduce the need for trained experts on-site during surgical procedures.
Open AccessDetection of breast cancer lymph node metastases in frozen sections with a point-of-care low-cost microscope scanner
Background: Detection of lymph node metastases is essential in breast cancer diagnostics and staging, affecting treatment and prognosis. Intraoperative microscopy analysis of sentinel lymph node frozen sections is standard for detection of axillary metastases, but requires access to a pathologist for sample analysis. Remote analysis of digitized samples is an alternative solution, but is limited by the requirement for high-end slide scanning equipment. Objective: To determine whether the image quality achievable with a low-cost, miniature digital microscope scanner is sufficient for detection of metastases in breast cancer lymph node frozen sections. Methods: Lymph node frozen sections from 79 breast cancer patients were digitized using a prototype miniature microscope scanner and a high-end slide scanner. Images were independently reviewed by two pathologists and results compared between devices with conventional light microscopy analysis as ground truth. Results: Detection of metastases in the images acquired with the miniature scanner yielded an overall sensitivity of 91 % and specificity of 99 % and showed strong agreement when compared to light microscopy ( k = 0.91). Strong agreement was also observed when results were compared to results from the high-end slide scanner ( k = 0.94). A majority of discrepant cases were micrometastases and sections of which no anticytokeratin staining was available. Conclusion: Accuracy of detection of metastatic cells in breast cancer sentinel lymph node frozen sections by visual analysis of samples digitized using low-cost, point-of-care microscopy is comparable to analysis of digital samples scanned using a high-end, whole slide scanner. This technique could potentially provide a workflow for digital diagnostics in resource-limited settings, facilitate sample analysis at the point-of-care and reduce the need for trained experts on-site during surgical procedures.
- Open Access
- 30 June 2017
- Published by Taylor & Francis in Global Health Action
- Vol. 10 (sup3) , 1337325
Point-of-care mobile digital microscopy and deep learning for the detection of soil-transmitted helminths and Schistosoma haematobium
Background: Microscopy remains the gold standard in the diagnosis of neglected tropical diseases. As resource limited, rural areas often lack laboratory equipment and trained personnel, new diagnostic techniques are needed. Low-cost, point-of-care imaging devices show potential in the diagnosis of these diseases. Novel, digital image analysis algorithms can be utilized to automate sample analysis. Objective: Evaluation of the imaging performance of a miniature digital microscopy scanner for the diagnosis of soil-transmitted helminths and Schistosoma haematobium, and training of a deep learning-based image analysis algorithm for automated detection of soil-transmitted helminths in the captured images. Methods: A total of 13 iodine-stained stool samples containing Ascaris lumbricoides, Trichuris trichiura and hookworm eggs and 4 urine samples containing Schistosoma haematobium were digitized using a reference whole slide-scanner and the mobile microscopy scanner. Parasites in the images were identified by visual examination and by analysis with a deep learning-based image analysis algorithm in the stool samples. Results were compared between the digital and visual analysis of the images showing helminth eggs. Results: Parasite identification by visual analysis of digital slides captured with the mobile microscope was feasible for all analyzed parasites. Although the spatial resolution of the reference slide-scanner is higher, the resolution of the mobile microscope is sufficient for reliable identification and classification of all parasites studied. Digital image analysis of stool sample images captured with the mobile microscope showed high sensitivity for detection of all helminths studied (range of sensitivity = 83.3–100%) in the test set (n = 217) of manually labeled helminth eggs. Conclusions: In this proof-of-concept study, the imaging performance of a mobile, digital microscope was sufficient for visual detection of soil-transmitted helminths and Schistosoma haematobium. Furthermore, we show that deep learning-based image analysis can be utilized for the automated detection and classification of helminths in the captured images.
- 30 June 2017
- Published by Taylor & Francis in Global Health Action
- Vol. 10 (sup3) , 1337325
Open AccessPoint-of-care mobile digital microscopy and deep learning for the detection of soil-transmitted helminths and Schistosoma haematobium
Background: Microscopy remains the gold standard in the diagnosis of neglected tropical diseases. As resource limited, rural areas often lack laboratory equipment and trained personnel, new diagnostic techniques are needed. Low-cost, point-of-care imaging devices show potential in the diagnosis of these diseases. Novel, digital image analysis algorithms can be utilized to automate sample analysis. Objective: Evaluation of the imaging performance of a miniature digital microscopy scanner for the diagnosis of soil-transmitted helminths and Schistosoma haematobium, and training of a deep learning-based image analysis algorithm for automated detection of soil-transmitted helminths in the captured images. Methods: A total of 13 iodine-stained stool samples containing Ascaris lumbricoides, Trichuris trichiura and hookworm eggs and 4 urine samples containing Schistosoma haematobium were digitized using a reference whole slide-scanner and the mobile microscopy scanner. Parasites in the images were identified by visual examination and by analysis with a deep learning-based image analysis algorithm in the stool samples. Results were compared between the digital and visual analysis of the images showing helminth eggs. Results: Parasite identification by visual analysis of digital slides captured with the mobile microscope was feasible for all analyzed parasites. Although the spatial resolution of the reference slide-scanner is higher, the resolution of the mobile microscope is sufficient for reliable identification and classification of all parasites studied. Digital image analysis of stool sample images captured with the mobile microscope showed high sensitivity for detection of all helminths studied (range of sensitivity = 83.3–100%) in the test set (n = 217) of manually labeled helminth eggs. Conclusions: In this proof-of-concept study, the imaging performance of a mobile, digital microscope was sufficient for visual detection of soil-transmitted helminths and Schistosoma haematobium. Furthermore, we show that deep learning-based image analysis can be utilized for the automated detection and classification of helminths in the captured images.