Giovanni Jacopo Ughi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Giovanni Jacopo Ughi has a total of 307 co-authors. Here are the top co-authors by number of shared publications:
Tom Adriaenssens
Cardiovascular Diseases, University Hospitals Leuven, Leuven, Belgium
21 shared publicationsWalter Desmet
19 shared publicationsChristophe Dubois
15 shared publications- Jan D'Hooge
Department of Cardiovascular sciences, KU Leuven, Leuven, Belgium
15 shared publications - Peter Sinnaeve
Department of Cardiovascular Medicine, University Hospitals Leuven, Leuven, Belgium (P.S.).
11 shared publications Mark Coosemans
10 shared publications
Latest Publications
- 30 July 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (11) , 2758
Neuro Optical Coherence Tomography Imaging for Intracranial Aneurysm Treatment: A Technical Video Case
- 30 July 2026
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 47 (11) , 2758
Neuro Optical Coherence Tomography Imaging for Intracranial Aneurysm Treatment: A Technical Video Case
- 1 June 2026
- Published by Wolters Kluwer Health in Stroke
- Vol. 57 (6) , e194-e196
Neuro Optical Coherence Tomography Guided Mechanical Thrombectomy
- 1 June 2026
- Published by Wolters Kluwer Health in Stroke
- Vol. 57 (6) , e194-e196
Neuro Optical Coherence Tomography Guided Mechanical Thrombectomy
- Open Access
- 1 May 2026
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 107 (10) , 323-334
Optical coherence tomography in neurovascular intervention: Technical aspects and emerging directions
- 1 May 2026
- Published by Elsevier in Diagnostic and Interventional Imaging
- Vol. 107 (10) , 323-334
Open AccessOptical coherence tomography in neurovascular intervention: Technical aspects and emerging directions
- 20 February 2026
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (8) , 1796-1811
Development, image interpretation, clinical experience, and applications of optical coherence tomography in neurointerventional surgery
Angiography remains the standard imaging modality for evaluating vascular disease and guiding endovascular interventions; however, its limited spatial resolution restricts visualization of vessel wall pathology and therapeutic devices. Over the past decade, intravascular optical coherence tomography (OCT) has emerged as a transformative tool in coronary artery disease. OCT provides three-dimensional, high-resolution imaging of coronary arteries, enabling assessment of vessel wall microstructure, plaque composition, lumen geometry, and stent deployment. This level of detail has advanced the understanding of coronary pathology and contributed to improved outcomes in percutaneous coronary interventions. Major cardiology societies now recommend the use of intravascular imaging, including OCT, for complex coronary interventions with level 1A evidence. OCT is now expanding beyond the coronary vasculature, with growing interest in its potential role in neurointerventional surgery. While limited use of OCT has been reported in the neurovasculature, the characteristics of a coronary OCT device prevent routine use in intracranial arteries. A new generation of intravascular OCT technology has been developed for the tortuous and complex anatomy of cerebral vessels. Early clinical experience has investigated its safety, feasibility, and utility for intracranial vascular imaging. Neuro-dedicated OCT technology could represent a significant advancement in cerebrovascular imaging, offering insights beyond the capabilities of current modalities, with the potential to improve current understanding of neurovascular pathology and refine diagnostic and therapeutic strategies. Successful translation of OCT into neurointervention, however, also requires establishing principles for image interpretation to assess neurovascular disease and therapeutic devices. This article aims to provide guidance for interpreting OCT imaging of intracranial arteries. In addition, it reviews applications of OCT in neurointervention and describes the development of neuro-specific OCT technology.
- 20 February 2026
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (8) , 1796-1811
Development, image interpretation, clinical experience, and applications of optical coherence tomography in neurointerventional surgery
Angiography remains the standard imaging modality for evaluating vascular disease and guiding endovascular interventions; however, its limited spatial resolution restricts visualization of vessel wall pathology and therapeutic devices. Over the past decade, intravascular optical coherence tomography (OCT) has emerged as a transformative tool in coronary artery disease. OCT provides three-dimensional, high-resolution imaging of coronary arteries, enabling assessment of vessel wall microstructure, plaque composition, lumen geometry, and stent deployment. This level of detail has advanced the understanding of coronary pathology and contributed to improved outcomes in percutaneous coronary interventions. Major cardiology societies now recommend the use of intravascular imaging, including OCT, for complex coronary interventions with level 1A evidence. OCT is now expanding beyond the coronary vasculature, with growing interest in its potential role in neurointerventional surgery. While limited use of OCT has been reported in the neurovasculature, the characteristics of a coronary OCT device prevent routine use in intracranial arteries. A new generation of intravascular OCT technology has been developed for the tortuous and complex anatomy of cerebral vessels. Early clinical experience has investigated its safety, feasibility, and utility for intracranial vascular imaging. Neuro-dedicated OCT technology could represent a significant advancement in cerebrovascular imaging, offering insights beyond the capabilities of current modalities, with the potential to improve current understanding of neurovascular pathology and refine diagnostic and therapeutic strategies. Successful translation of OCT into neurointervention, however, also requires establishing principles for image interpretation to assess neurovascular disease and therapeutic devices. This article aims to provide guidance for interpreting OCT imaging of intracranial arteries. In addition, it reviews applications of OCT in neurointervention and describes the development of neuro-specific OCT technology.
- Open Access
- 18 March 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (3) , 102577
Efficacy and Safety of High-Frequency Optical Coherence Tomography (HF-OCT) for Coronary Imaging: A Multicenter Study
- 18 March 2025
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 4 (3) , 102577
Open AccessEfficacy and Safety of High-Frequency Optical Coherence Tomography (HF-OCT) for Coronary Imaging: A Multicenter Study
- 15 May 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 16 (747) , eadl4497
Volumetric microscopy of cerebral arteries with a miniaturized optical coherence tomography imaging probe
Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography ( n OCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The n OCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using n OCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. n OCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.
- 15 May 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 16 (747) , eadl4497
Volumetric microscopy of cerebral arteries with a miniaturized optical coherence tomography imaging probe
Endovascular interventions are increasingly becoming the preferred approach for treating strokes and cerebral artery diseases. These procedures rely on sophisticated angiographical imaging guidance, which encounters challenges because of limited contrast and spatial resolution. Achieving a more precise visualization of the underlying arterial pathology and neurovascular implants is crucial for accurate procedural decision-making. In a human study involving 32 patients, we introduced the clinical application of a miniaturized endovascular neuro optical coherence tomography ( n OCT) imaging probe. This technology was designed to navigate the tortuous paths of the cerebrovascular circulation and to offer high-resolution imaging in situ. The n OCT probe is compatible with standard neurovascular microcatheters, integrating with the procedural workflow used in clinical routine. Equipped with a miniaturized optical fiber and a distal lens, the probe illuminates the tissue and collects the backscattered, near-infrared light. While rotating the fiber and the lens at high speed, the probe is rapidly retracted, creating a spiral-shaped light pattern to comprehensively capture the arterial wall and implanted devices. Using n OCT, we demonstrated volumetric microscopy of cerebral arteries in patients undergoing endovascular procedures. We imaged the anterior and posterior circulation of the brain, including distal segments of the internal carotid and middle-cerebral arteries, as well as the vertebral, basilar, and posterior cerebral arteries. We captured a broad spectrum of neurovascular pathologies, such as brain aneurysms, ischemic stroke, arterial stenoses, dissections, and intracranial atherosclerotic disease. n OCT offered artifact-free, high-resolution visualizations of intracranial artery pathology and neurovascular devices.
- 1 August 2023
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 16 (9) , 928-933
A novel intrasaccular aneurysm device with high complete occlusion rate: initial results in a rabbit model
Background Intrasaccular flow-disrupting devices are a safe and effective treatment strategy for intracranial aneurysms. We utilized high-frequency optical coherence tomography (HF-OCT) and digital subtraction angiography (DSA) to evaluate SEAL Arc, a new intrasaccular device, and compare the findings with the well-established Woven EndoBridge (WEB) device in an animal model of saccular aneurysms. Methods In a rabbit model, elastase-induced aneurysms were treated with SEAL Arc (n=11) devices. HF-OCT and DSA were performed after implant and repeated after 12 weeks. Device protrusion and malapposition were assessed at implant time and scored on a binary system. Aneurysm occlusion was assessed at 12 weeks with the WEB Occlusion Scale and dichotomized to complete (A and B) or incomplete (C and D) occlusion. The percentage of neointimal coverage after 12 weeks was quantified using HF-OCT. We compared these data to previously published historical controls treated with the gold-standard WEB device (n=24) in the same model. Results Aneurysm size and device placement were not significantly different between the two groups. Complete occlusion was demonstrated in 80% of the SEAL Arc devices, which compared favorably to the 21% of the aneurysms treated with WEB devices (P=0.002). Neointimal coverage across SEAL Arc devices was 86±15% compared with 49±27% for WEB (P=0.001). Protruding devices had significantly less neointimal coverage (PConclusion Complete early aneurysm occlusion was frequently observed in the SEAL Arc treated aneurysms, with significant neointimal coverage after 12 weeks.
- 1 August 2023
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 16 (9) , 928-933
A novel intrasaccular aneurysm device with high complete occlusion rate: initial results in a rabbit model
Background Intrasaccular flow-disrupting devices are a safe and effective treatment strategy for intracranial aneurysms. We utilized high-frequency optical coherence tomography (HF-OCT) and digital subtraction angiography (DSA) to evaluate SEAL Arc, a new intrasaccular device, and compare the findings with the well-established Woven EndoBridge (WEB) device in an animal model of saccular aneurysms. Methods In a rabbit model, elastase-induced aneurysms were treated with SEAL Arc (n=11) devices. HF-OCT and DSA were performed after implant and repeated after 12 weeks. Device protrusion and malapposition were assessed at implant time and scored on a binary system. Aneurysm occlusion was assessed at 12 weeks with the WEB Occlusion Scale and dichotomized to complete (A and B) or incomplete (C and D) occlusion. The percentage of neointimal coverage after 12 weeks was quantified using HF-OCT. We compared these data to previously published historical controls treated with the gold-standard WEB device (n=24) in the same model. Results Aneurysm size and device placement were not significantly different between the two groups. Complete occlusion was demonstrated in 80% of the SEAL Arc devices, which compared favorably to the 21% of the aneurysms treated with WEB devices (P=0.002). Neointimal coverage across SEAL Arc devices was 86±15% compared with 49±27% for WEB (P=0.001). Protruding devices had significantly less neointimal coverage (PConclusion Complete early aneurysm occlusion was frequently observed in the SEAL Arc treated aneurysms, with significant neointimal coverage after 12 weeks.
- 17 August 2022
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 15 (9) , 919-923
High-frequency optical coherence tomography predictors of aneurysm occlusion following flow diverter treatment in a preclinical model
Background: High-frequency optical coherence tomography (HF-OCT) is an intravascular imaging method that allows for volumetric imaging of flow diverters in vivo.Objective: To examine the hypothesis that a threshold for both volume and area of communicating malapposition can be predictive of early aneurysm occlusion.Methods: Fifty-two rabbits underwent elastase aneurysm formation, followed by treatment with a flow diverter. At the time of implant, HF-OCT was acquired to study the rate and degree of communicating malapposition. Treated aneurysms were allowed to heal for either 90 or 180 days and euthanized following catheter angiography. Healing was dichotomized into aneurysm remnant or neck remnant/complete occlusion. Communicating malapposition was measured by HF-OCT using a semi-automatic algorithm able to detect any points where the flow diverter was more than 50 µm from the vessel wall. This was then summed across image slices to either a volume or area. Finally, a subsampled population was used to train a statistical classifier for the larger dataset.Results: No difference in occlusion rate was found between device type or follow-up time (p=0.28 and p=0.67, respectively). Both volume and area of malapposition were significantly lower in aneurysms with a good outcome (p3or a normalized area less than 0.69 as quantified by HF-OCT was predictive of occlusion (p<0.001, each).Conclusions: HF-OCT allows for measurements of both volume and area of malapposition and, from these measurements, an accurate prediction for early aneurysm occlusion can be made.
- 17 August 2022
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 15 (9) , 919-923
High-frequency optical coherence tomography predictors of aneurysm occlusion following flow diverter treatment in a preclinical model
Background: High-frequency optical coherence tomography (HF-OCT) is an intravascular imaging method that allows for volumetric imaging of flow diverters in vivo.Objective: To examine the hypothesis that a threshold for both volume and area of communicating malapposition can be predictive of early aneurysm occlusion.Methods: Fifty-two rabbits underwent elastase aneurysm formation, followed by treatment with a flow diverter. At the time of implant, HF-OCT was acquired to study the rate and degree of communicating malapposition. Treated aneurysms were allowed to heal for either 90 or 180 days and euthanized following catheter angiography. Healing was dichotomized into aneurysm remnant or neck remnant/complete occlusion. Communicating malapposition was measured by HF-OCT using a semi-automatic algorithm able to detect any points where the flow diverter was more than 50 µm from the vessel wall. This was then summed across image slices to either a volume or area. Finally, a subsampled population was used to train a statistical classifier for the larger dataset.Results: No difference in occlusion rate was found between device type or follow-up time (p=0.28 and p=0.67, respectively). Both volume and area of malapposition were significantly lower in aneurysms with a good outcome (p3or a normalized area less than 0.69 as quantified by HF-OCT was predictive of occlusion (p<0.001, each).Conclusions: HF-OCT allows for measurements of both volume and area of malapposition and, from these measurements, an accurate prediction for early aneurysm occlusion can be made.
- Open Access
- 3 February 2022
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 14 (5) , 420-428
Transvascular in vivo microscopy of the subarachnoid space
Background The micro-architectonics of the subarachnoid space (SAS) remain partially understood and largely ignored, likely the result of the inability to image these structures in vivo. We explored transvascular imaging with high-frequency optical coherence tomography (HF-OCT) to interrogate the SAS. Methods In vivo HF-OCT was performed in 10 dogs in both the posterior and anterior cerebral circulations. The conduit vessels used were the basilar, anterior spinal, and middle and anterior cerebral arteries through which the perivascular SAS was imaged. The HF-OCT imaging probe was introduced via a microcatheter and images were acquired using a contrast injection (3.5 mL/s) for blood clearance. Segmentation and three-dimensional rendering of HF-OCT images were performed to study the different configurations and porosity of the subarachnoid trabeculae (SAT) as a function of location. Results Of 13 acquisitions, three were excluded due to suboptimal image quality. Analysis of 15 locations from seven animals was performed showing six distinct configurations of arachnoid structures in the posterior circulation and middle cerebral artery, ranging from minimal presence of SAT to dense networks and membranes. Different locations showed predilection for specific arachnoid morphologies. At the basilar bifurcation, a thick, fenestrated membrane had a unique morphology. SAT average thickness was 100 µm and did not vary significantly based on location. Similarly, the porosity of the SAT averaged 91% and showed low variability. Conclusion We have demonstrated the feasibility to image the structures of the SAS with transvascular HF-OCT. Future studies are planned to further map the SAT to increase our understanding of their function and possible impact on neurovascular pathologies.
- 3 February 2022
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 14 (5) , 420-428
Open AccessTransvascular in vivo microscopy of the subarachnoid space
Background The micro-architectonics of the subarachnoid space (SAS) remain partially understood and largely ignored, likely the result of the inability to image these structures in vivo. We explored transvascular imaging with high-frequency optical coherence tomography (HF-OCT) to interrogate the SAS. Methods In vivo HF-OCT was performed in 10 dogs in both the posterior and anterior cerebral circulations. The conduit vessels used were the basilar, anterior spinal, and middle and anterior cerebral arteries through which the perivascular SAS was imaged. The HF-OCT imaging probe was introduced via a microcatheter and images were acquired using a contrast injection (3.5 mL/s) for blood clearance. Segmentation and three-dimensional rendering of HF-OCT images were performed to study the different configurations and porosity of the subarachnoid trabeculae (SAT) as a function of location. Results Of 13 acquisitions, three were excluded due to suboptimal image quality. Analysis of 15 locations from seven animals was performed showing six distinct configurations of arachnoid structures in the posterior circulation and middle cerebral artery, ranging from minimal presence of SAT to dense networks and membranes. Different locations showed predilection for specific arachnoid morphologies. At the basilar bifurcation, a thick, fenestrated membrane had a unique morphology. SAT average thickness was 100 µm and did not vary significantly based on location. Similarly, the porosity of the SAT averaged 91% and showed low variability. Conclusion We have demonstrated the feasibility to image the structures of the SAS with transvascular HF-OCT. Future studies are planned to further map the SAT to increase our understanding of their function and possible impact on neurovascular pathologies.
- 28 September 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (7) , 669-673
High-resolution image-guided WEB aneurysm embolization by high-frequency optical coherence tomography
Background High-frequency optical coherence tomography (HF-OCT) is an intra-vascular imaging technique capable of assessing device-vessel interactions at spatial resolution approaching 10 µm. We tested the hypothesis that adequately deployed Woven EndoBridge (WEB) devices as visualized by HF-OCT lead to higher aneurysm occlusion rates. Methods In a leporine model, elastase-induced aneurysms (n=24) were treated with the WEB device. HF-OCT and digital subtraction angiography (DSA) were performed following WEB deployment and repeated at 4, 8, and 12 weeks. Protrusion (0-present, 1-absent) and malapposition (0-malapposed, 1-neck apposition >50%) were binary coded. A device was considered ‘adequately deployed’ by HF-OCT and DSA if apposed and non-protruding. Aneurysm healing on DSA was reported using the 4-point WEB occlusion score: A or B grades were considered positive outcome. Neointimal coverage was quantified on HF-OCT images at 12 weeks and compared with scanning electron microscopy (SEM). Results Adequate deployment on HF-OCT correlated with positive outcome (P=0.007), but no statistically significant relationship was found between good outcome and adequate deployment on DSA (P=0.289). Absence of protrusion on HF-OCT correlated with a positive outcome (P=0.006); however, malapposition alone had no significant relationship (P=0.19). HF-OCT showed a strong correlation with SEM for the assessment of areas of neointimal tissue (R²=0.96; PConclusion HF-OCT visualizes features that can determine adequate device deployment to prognosticate early aneurysm occlusion following WEB implantation and can be used to longitudinally monitor aneurysm healing progression.
- 28 September 2020
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 13 (7) , 669-673
High-resolution image-guided WEB aneurysm embolization by high-frequency optical coherence tomography
Background High-frequency optical coherence tomography (HF-OCT) is an intra-vascular imaging technique capable of assessing device-vessel interactions at spatial resolution approaching 10 µm. We tested the hypothesis that adequately deployed Woven EndoBridge (WEB) devices as visualized by HF-OCT lead to higher aneurysm occlusion rates. Methods In a leporine model, elastase-induced aneurysms (n=24) were treated with the WEB device. HF-OCT and digital subtraction angiography (DSA) were performed following WEB deployment and repeated at 4, 8, and 12 weeks. Protrusion (0-present, 1-absent) and malapposition (0-malapposed, 1-neck apposition >50%) were binary coded. A device was considered ‘adequately deployed’ by HF-OCT and DSA if apposed and non-protruding. Aneurysm healing on DSA was reported using the 4-point WEB occlusion score: A or B grades were considered positive outcome. Neointimal coverage was quantified on HF-OCT images at 12 weeks and compared with scanning electron microscopy (SEM). Results Adequate deployment on HF-OCT correlated with positive outcome (P=0.007), but no statistically significant relationship was found between good outcome and adequate deployment on DSA (P=0.289). Absence of protrusion on HF-OCT correlated with a positive outcome (P=0.006); however, malapposition alone had no significant relationship (P=0.19). HF-OCT showed a strong correlation with SEM for the assessment of areas of neointimal tissue (R²=0.96; PConclusion HF-OCT visualizes features that can determine adequate device deployment to prognosticate early aneurysm occlusion following WEB implantation and can be used to longitudinally monitor aneurysm healing progression.