Robert Driver
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Driver has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
Gilbert Y. Grondin
12 shared publicationsRichard Sause
6 shared publicationsAnjan K. Bhowmick
5 shared publicationsD. J. Laurie Kennedy
Prof Emeritus, Dept. of Civ. and Envir. Engrg., Univ. of Alberta, Edmonton, Alta., Canada
5 shared publicationsGeoffrey L. Kulak
Department of Civil and Environmental Engineering, University of Alberta, Edmonton, AB, Canada, T6G 2W2
5 shared publicationsHassan H. Abbas
5 shared publications
Latest Publications
- 1 September 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (9)
Lateral–Torsional and Distortional Buckling of I-Shaped Welded Steel Girders
- 1 September 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (9)
Lateral–Torsional and Distortional Buckling of I-Shaped Welded Steel Girders
- 1 October 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (10) , 04022149
Lateral Torsional Buckling Response of Compact I-Shaped Welded Steel Girders
Recent studies investigating lateral torsional buckling suggest that North American steel design provisions may overestimate the bending resistance of welded girders that buckle laterally in the inelastic range. Furthermore, these provisions do not distinguish between rolled and welded members, but welded girders are widely suspected of possessing unfavorable residual stress distributions that may cause them to be more susceptible to lateral torsional buckling than their rolled counterparts. However, lack of sufficient supporting experimental test data may render existing analytically based assessments of the design equations inadequate. To address the paucity of physical testing, an experimental program was developed to determine the lateral torsional buckling resistance of full-scale I-shaped welded three-plate steel girders fabricated with current shop processes. This paper describes the development of the test program and a unique girder-stability test bed. Test results for seven girders, including measured initial geometric imperfections, load–displacement responses, and moment capacities, are then presented. A finite-element model of the test specimens, validated against the test data, is finally used to investigate the adequacy of the beam design provisions specified in the Canadian and US steel design standards. The results confirm that the current design equations can accurately predict the moment resistance of compact welded steel girders that fail in either the elastic or inelastic lateral torsional buckling mode.
- 1 October 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 148 (10) , 04022149
Lateral Torsional Buckling Response of Compact I-Shaped Welded Steel Girders
Recent studies investigating lateral torsional buckling suggest that North American steel design provisions may overestimate the bending resistance of welded girders that buckle laterally in the inelastic range. Furthermore, these provisions do not distinguish between rolled and welded members, but welded girders are widely suspected of possessing unfavorable residual stress distributions that may cause them to be more susceptible to lateral torsional buckling than their rolled counterparts. However, lack of sufficient supporting experimental test data may render existing analytically based assessments of the design equations inadequate. To address the paucity of physical testing, an experimental program was developed to determine the lateral torsional buckling resistance of full-scale I-shaped welded three-plate steel girders fabricated with current shop processes. This paper describes the development of the test program and a unique girder-stability test bed. Test results for seven girders, including measured initial geometric imperfections, load–displacement responses, and moment capacities, are then presented. A finite-element model of the test specimens, validated against the test data, is finally used to investigate the adequacy of the beam design provisions specified in the Canadian and US steel design standards. The results confirm that the current design equations can accurately predict the moment resistance of compact welded steel girders that fail in either the elastic or inelastic lateral torsional buckling mode.
- 19 October 2018
- Published by Elsevier in Measurement
- Vol. 134, 1-5
An integrated and automated calibration system for pneumatic piston gauges
- 19 October 2018
- Published by Elsevier in Measurement
- Vol. 134, 1-5
An integrated and automated calibration system for pneumatic piston gauges
- 1 August 2018
- Published by Elsevier in Structures
- Vol. 15, 13-27
Behaviour of Single Angle Connections Under Simultaneous Shear, Tension and Moment
- 1 August 2018
- Published by Elsevier in Structures
- Vol. 15, 13-27
Behaviour of Single Angle Connections Under Simultaneous Shear, Tension and Moment
- 1 February 2018
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 141, 50-62
Design of steel wide-flange members for torsion applied through one flange
- 1 February 2018
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 141, 50-62
Design of steel wide-flange members for torsion applied through one flange
- 1 February 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (2)
Test of a Steel Plate Shear Wall with Partially Encased Composite Columns and RBS Frame Connections
A large-scale steel plate shear wall with partially encased composite (PEC) columns and reduced beam section (RBS) frame connections was tested at the University of Alberta to investigate the behavior of the system and quantify some key characteristics related to seismic design of this system. The use of RBS connections was intended to reduce the demand on the beam-to-column connection and obtain improved seismic performance. Subjected to quasi-static cyclic load until severe damage was observed, the specimen showed desirable characteristics such as high elastic lateral stiffness, ductility, and energy dissipation capacity. The use of RBS frame connections was proven to be a viable option to improve the seismic performance of these walls. The test observations indicated that the detailing of the PEC columns played an important role in improving the seismic performance of the specimen. Several design and detailing recommendations have been made based on the observations during this test and previous experimental studies.
- 1 February 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (2)
Test of a Steel Plate Shear Wall with Partially Encased Composite Columns and RBS Frame Connections
A large-scale steel plate shear wall with partially encased composite (PEC) columns and reduced beam section (RBS) frame connections was tested at the University of Alberta to investigate the behavior of the system and quantify some key characteristics related to seismic design of this system. The use of RBS connections was intended to reduce the demand on the beam-to-column connection and obtain improved seismic performance. Subjected to quasi-static cyclic load until severe damage was observed, the specimen showed desirable characteristics such as high elastic lateral stiffness, ductility, and energy dissipation capacity. The use of RBS frame connections was proven to be a viable option to improve the seismic performance of these walls. The test observations indicated that the detailing of the PEC columns played an important role in improving the seismic performance of the specimen. Several design and detailing recommendations have been made based on the observations during this test and previous experimental studies.
- 1 November 2017
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 138, 580-593
Behaviour of shear tab connections in column removal scenario
- 1 November 2017
- Published by Elsevier in Journal of Constructional Steel Research
- Vol. 138, 580-593
Behaviour of shear tab connections in column removal scenario
- 1 May 2017
- Published by Elsevier in Structures
- Vol. 10, 49-58
Full-scale Tests of Stabilized and Unstabilized Extended Single-plate Connections
- 1 May 2017
- Published by Elsevier in Structures
- Vol. 10, 49-58
Full-scale Tests of Stabilized and Unstabilized Extended Single-plate Connections
- 4 April 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 153-164
Modeling and Testing of Shear Connections with Beams under Tension Membrane Loading
Structural steel framing members subjected to blast loading respond initially in flexure followed by tension membrane as deflection increases. If member connections have been adequately designed and detailed, those members can achieve large deformations and achieve significantly greater load capacity in tension membrane than can be developed in flexure only. The applied load and large deformation of the member produce a tensile axial force that must be resisted by both the member and corresponding connections. With rigid connections, the normal-to-plane deformations cause elongation of the member. Even a small axial elongation along the component axis can produce significant tensile forces. If a portion of the axial deformation could be relieved by incorporating flexibility of the connections, the resulting axial force in the member and the force demand on the connections can be reduced. Moreover, similar concepts used while designing the component are required for the connection design such as: strength, stiffness, ductility, especially if a ductile failure mode in the component is expected. Ample research has been done to study semi-rigid connection behavior during conventional loading. However, there is limited research of connections for members subjected to blast and impact loading. Recently, the University of Alberta has performed research on the behavior of shear connections (SC) of structures subjected to progressive collapse loading. Although this research evaluated response with a lower strain rate effect than typically occurs with blast loading, the connection test data is valuable for model development. Currently, there is no comprehensive blast standard or guideline for design of connections in components subjected to blast load. This paper presents a multi-degree of freedom (MDOF) approach to compute the overall response of a steel member subjected to blast loading, including the component (with large deformation) and connections. Connection models proposed by the University of Alberta are incorporated in the MDOF tool. This MDOF approach can predict a more realistic response of the system subjected to blast loading than provided by typical single-degree-of-freedom (SDOF) approaches, which ignore connection flexibility.
- 4 April 2017
- Published by American Society of Civil Engineers (ASCE)
- p. 153-164
Modeling and Testing of Shear Connections with Beams under Tension Membrane Loading
Structural steel framing members subjected to blast loading respond initially in flexure followed by tension membrane as deflection increases. If member connections have been adequately designed and detailed, those members can achieve large deformations and achieve significantly greater load capacity in tension membrane than can be developed in flexure only. The applied load and large deformation of the member produce a tensile axial force that must be resisted by both the member and corresponding connections. With rigid connections, the normal-to-plane deformations cause elongation of the member. Even a small axial elongation along the component axis can produce significant tensile forces. If a portion of the axial deformation could be relieved by incorporating flexibility of the connections, the resulting axial force in the member and the force demand on the connections can be reduced. Moreover, similar concepts used while designing the component are required for the connection design such as: strength, stiffness, ductility, especially if a ductile failure mode in the component is expected. Ample research has been done to study semi-rigid connection behavior during conventional loading. However, there is limited research of connections for members subjected to blast and impact loading. Recently, the University of Alberta has performed research on the behavior of shear connections (SC) of structures subjected to progressive collapse loading. Although this research evaluated response with a lower strain rate effect than typically occurs with blast loading, the connection test data is valuable for model development. Currently, there is no comprehensive blast standard or guideline for design of connections in components subjected to blast load. This paper presents a multi-degree of freedom (MDOF) approach to compute the overall response of a steel member subjected to blast loading, including the component (with large deformation) and connections. Connection models proposed by the University of Alberta are incorporated in the MDOF tool. This MDOF approach can predict a more realistic response of the system subjected to blast loading than provided by typical single-degree-of-freedom (SDOF) approaches, which ignore connection flexibility.
- 1 February 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 142 (2)
Large-Scale Test of a Modular Steel Plate Shear Wall with Partially Encased Composite Columns
As part of an experimental study on the behavior of steel plate shear walls with partially encased composite columns, a large-scale modular specimen was tested at the University of Alberta to observe and quantify some important parameters related to seismic design of this type of structure. The two-story one-bay specimen was subjected to cyclic load until it failed. It was shown that the modular construction method used to build the specimen had very little effect on the overall behavior. The specimen exhibited high initial stiffness, good displacement ductility and high energy dissipation capacity. The observations during the test indicated that the detailing of the composite columns played an important role in improving the seismic performance of the specimen. Based on the results of the current experiment and previous studies, design and detailing recommendations have been made.
- 1 February 2016
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 142 (2)
Large-Scale Test of a Modular Steel Plate Shear Wall with Partially Encased Composite Columns
As part of an experimental study on the behavior of steel plate shear walls with partially encased composite columns, a large-scale modular specimen was tested at the University of Alberta to observe and quantify some important parameters related to seismic design of this type of structure. The two-story one-bay specimen was subjected to cyclic load until it failed. It was shown that the modular construction method used to build the specimen had very little effect on the overall behavior. The specimen exhibited high initial stiffness, good displacement ductility and high energy dissipation capacity. The observations during the test indicated that the detailing of the composite columns played an important role in improving the seismic performance of the specimen. Based on the results of the current experiment and previous studies, design and detailing recommendations have been made.