Xinyi Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xinyi Chen has a total of 218 co-authors. Here are the top co-authors by number of shared publications:
- Alan Man Ching Ng
Department of Physics, Southern University of Science and Technology, Shenzhen, China
30 shared publications - Miao Lu
Xiamen University
15 shared publications F. Fang
Department of Physics, The University of Hong Kong, Pokfulam Road, Hong Kong
11 shared publicationsW. K. Chan
Department of Chemistry, The University of Hong Kong, Pokfulam Road, Hong Kong
10 shared publications- Aleksandra B. Djurisic
Department of Physics, The University of Hong Kong, Hong Kong, China
8 shared publications Deng Long
8 shared publications
Latest Publications
- Open Access
- 15 August 2026
- Published by Elsevier in SSRN Electronic Journal
Unlabeled Data Obtained from Gradient Dilution for Calibrating Turbidity and Chromaticity Measurement
Environmental perturbation could lead to inaccuracy of long-term sensing of water quality. In this work, an optical turbidity and chromaticity sensor was constructed, combined with a Bayesian semi-supervised machine learning approach to continuously improve prediction accuracy based on unlabeled data. Starting from a series of preset solution and an initial prediction model, the semi-supervised data was formed based on the expanded dataset of gradient diluted samples for prediction model updating, and it was found that the prediction accuracy can be significant improved. In addition, a 7 days field testing demonstrated that the sensor's deviation was within ±1.89 NTU and ±2.79 PCU relative to commercial turbidity and chromaticity meter, respectively. The result hints that the data obtained in actual sensor deployment can be used to continuously improve sensing performance, as well as to overcome the long-term inaccuracy induced by environmental perturbation and limited data for calibration.
- 15 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessUnlabeled Data Obtained from Gradient Dilution for Calibrating Turbidity and Chromaticity Measurement
Environmental perturbation could lead to inaccuracy of long-term sensing of water quality. In this work, an optical turbidity and chromaticity sensor was constructed, combined with a Bayesian semi-supervised machine learning approach to continuously improve prediction accuracy based on unlabeled data. Starting from a series of preset solution and an initial prediction model, the semi-supervised data was formed based on the expanded dataset of gradient diluted samples for prediction model updating, and it was found that the prediction accuracy can be significant improved. In addition, a 7 days field testing demonstrated that the sensor's deviation was within ±1.89 NTU and ±2.79 PCU relative to commercial turbidity and chromaticity meter, respectively. The result hints that the data obtained in actual sensor deployment can be used to continuously improve sensing performance, as well as to overcome the long-term inaccuracy induced by environmental perturbation and limited data for calibration.
- 10 December 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (51) , 69719-69728
The Influence of Different Nanoscale Channel Lengths in Low-Temperature-Grown Lateral MoS 2 Memristors
The memristor based on low-temperature growth of molybdenum disulfide (MoS2) is expected to integrate with current IC processes and become one of the fundamental devices for brainlike artificial intelligence hardware. To realize a high-density neural network, it is necessary to identify the size scaling effect of MoS2 memristors and determine whether they can match the size scaling of transistors. Therefore, the influence of different channel lengths on the performance of lateral nanoscale MoS2 memristors was investigated in this work. These memristors were constructed by low-temperature metal-organic chemical vapor deposition (MOCVD) growth of two-dimensional (2D) MoS2 between gold counter electrodes with different nanogaps that define the channel length of these lateral memristors from approximately 14 to 52 nm. By measuring their resistive switching behaviors, we found that the SET voltage decreases with the decrease of the channel length, which was proportional to the power 1.69 of the channel length; the threshold number of pulses (1 V, 1 kHz) required to convert the high-resistance state (HRS) to the low-resistance state (LRS) was found to be proportional to the power 2.87 of the channel length; and the threshold pulse magnitude to output spikes in a leaky integrate-and-fire (LIF) neuron model was found to be proportional to the power 1.01 of the channel length. The results indicate that as the channel length decreases, the voltage, threshold number of stimulation pulses, and threshold pulse amplitude required for resistive switching also decrease at a rate exceeding linear descent, which is basically consistent with the scaling trends of transistors.
- 10 December 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (51) , 69719-69728
The Influence of Different Nanoscale Channel Lengths in Low-Temperature-Grown Lateral MoS 2 Memristors
The memristor based on low-temperature growth of molybdenum disulfide (MoS2) is expected to integrate with current IC processes and become one of the fundamental devices for brainlike artificial intelligence hardware. To realize a high-density neural network, it is necessary to identify the size scaling effect of MoS2 memristors and determine whether they can match the size scaling of transistors. Therefore, the influence of different channel lengths on the performance of lateral nanoscale MoS2 memristors was investigated in this work. These memristors were constructed by low-temperature metal-organic chemical vapor deposition (MOCVD) growth of two-dimensional (2D) MoS2 between gold counter electrodes with different nanogaps that define the channel length of these lateral memristors from approximately 14 to 52 nm. By measuring their resistive switching behaviors, we found that the SET voltage decreases with the decrease of the channel length, which was proportional to the power 1.69 of the channel length; the threshold number of pulses (1 V, 1 kHz) required to convert the high-resistance state (HRS) to the low-resistance state (LRS) was found to be proportional to the power 2.87 of the channel length; and the threshold pulse magnitude to output spikes in a leaky integrate-and-fire (LIF) neuron model was found to be proportional to the power 1.01 of the channel length. The results indicate that as the channel length decreases, the voltage, threshold number of stimulation pulses, and threshold pulse amplitude required for resistive switching also decrease at a rate exceeding linear descent, which is basically consistent with the scaling trends of transistors.
- 20 September 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1378, 344689
Simultaneously calibrate and detect multiple analytes to offset the effects of co-existing regents and environmental fluctuations
- 20 September 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1378, 344689
Simultaneously calibrate and detect multiple analytes to offset the effects of co-existing regents and environmental fluctuations
- 16 April 2025
- Published by Wiley in Chemistry – An Asian Journal
- Vol. 20 (12) , e202500106
Photocatalytic Reduction of Carbon Dioxide: Designing the Active Sites and Tracking the Pathways
Photocatalytic reduction of carbon dioxide (CO2) realizes the recycling of carbon emissions and storage of solar energy into the bonding of organics at the same time, and thus attract great interest in the field of energy and environment. However, the current photocatalytic performance of CO2 reduction cannot match the industrial application. The design of highly efficient photocatalysts with precise selectivity and reliable long‐term stability is still a big challenge, partially because the mechanism of photocatalytic CO2 reduction to guide the design and fabrication, is not completely clear yet. The reduction can involve at most eight electrons for each CO2 molecule, during which several pathways might be opened up at the active sites to consume photocarriers to influence the selectivity and stability. The reduction pathways are dependent on the electronic structure and property of active sites, and the photocatalytic performance can be optimized if those pathways are thermodynamically or kinetically compatible for the target production. This review will summarize the strategy for designing the active sites on the surface of photocatalysts and the investigation on the relation between the active sites and pathways for photocatalytic CO2 reduction, looking ahead at the future development of the photocatalysts and devices for CO2 reduction.
- 16 April 2025
- Published by Wiley in Chemistry – An Asian Journal
- Vol. 20 (12) , e202500106
Photocatalytic Reduction of Carbon Dioxide: Designing the Active Sites and Tracking the Pathways
Photocatalytic reduction of carbon dioxide (CO2) realizes the recycling of carbon emissions and storage of solar energy into the bonding of organics at the same time, and thus attract great interest in the field of energy and environment. However, the current photocatalytic performance of CO2 reduction cannot match the industrial application. The design of highly efficient photocatalysts with precise selectivity and reliable long‐term stability is still a big challenge, partially because the mechanism of photocatalytic CO2 reduction to guide the design and fabrication, is not completely clear yet. The reduction can involve at most eight electrons for each CO2 molecule, during which several pathways might be opened up at the active sites to consume photocarriers to influence the selectivity and stability. The reduction pathways are dependent on the electronic structure and property of active sites, and the photocatalytic performance can be optimized if those pathways are thermodynamically or kinetically compatible for the target production. This review will summarize the strategy for designing the active sites on the surface of photocatalysts and the investigation on the relation between the active sites and pathways for photocatalytic CO2 reduction, looking ahead at the future development of the photocatalysts and devices for CO2 reduction.
- 26 March 2025
- Published by Springer Nature in Journal of Soils and Sediments
- Vol. 25 (4) , 1115-1133
Changes in fertility and microbial communities of red soil and their contribution to crop yield following long-term different fertilization
- 26 March 2025
- Published by Springer Nature in Journal of Soils and Sediments
- Vol. 25 (4) , 1115-1133
Changes in fertility and microbial communities of red soil and their contribution to crop yield following long-term different fertilization
- 30 July 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (8) , 3986-3993
A Simultaneous Calibration and Detection Strategy for Electrochemical Sensing with High Accuracy in Complex Water
The electrochemical sensors loaded with nanomaterials have exhibited a great sensitivity. Nonetheless, the field detection for complex waterbodies can be affected by cross-sensitivity, environmental conditions such as temperature and pH value, as well as the relatively low reproducibility and stability of nanomaterials. In this paper, a simultaneous calibration and detection (SCD) strategy is proposed to introduce a simultaneous and precise calibration during field electrochemical detection, which is composed of a linear regression algorithm and a compact electrochemical sensor containing a series of identical sensing cells. This design can significantly mitigate cross-sensitivity in complex water and the inconsistency of sensing materials. Applied in the NO2- detection for practical waterbodies, the SCD strategy has exhibited a relative error of no more than 9.6% for the measurement compared to the results obtained by the standard Griess method and higher accuracy than the normal electrochemical method. The SCD strategy is independent of sensing materials, indicating that it can be widely applied to various detections by just switching the corresponding sensing material.
- 30 July 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (8) , 3986-3993
A Simultaneous Calibration and Detection Strategy for Electrochemical Sensing with High Accuracy in Complex Water
The electrochemical sensors loaded with nanomaterials have exhibited a great sensitivity. Nonetheless, the field detection for complex waterbodies can be affected by cross-sensitivity, environmental conditions such as temperature and pH value, as well as the relatively low reproducibility and stability of nanomaterials. In this paper, a simultaneous calibration and detection (SCD) strategy is proposed to introduce a simultaneous and precise calibration during field electrochemical detection, which is composed of a linear regression algorithm and a compact electrochemical sensor containing a series of identical sensing cells. This design can significantly mitigate cross-sensitivity in complex water and the inconsistency of sensing materials. Applied in the NO2- detection for practical waterbodies, the SCD strategy has exhibited a relative error of no more than 9.6% for the measurement compared to the results obtained by the standard Griess method and higher accuracy than the normal electrochemical method. The SCD strategy is independent of sensing materials, indicating that it can be widely applied to various detections by just switching the corresponding sensing material.