Hyun-Tai Chung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hyun-Tai Chung has a total of 95 co-authors. Here are the top co-authors by number of shared publications:
- Sun Ha Paek
Department of Neurosurgery, Cancer Research Institute and Ischemic/Hypoxic Disease Institute, Seoul National University College of Medicine, Seoul, Korea
7 shared publications Tae Hoon Kim
Department of Nuclear Engineering Hanyang University College of Engineering Seoul Republic of Korea
7 shared publicationsHye Jeong Yang
Department of Biomedical Engineering, College of Medicine Catholic University of Korea Seoul Republic of Korea
6 shared publications- Hye Ran Park
Department of Neurosurgery, Soonchunhyang University Seoul Hospital, Seoul, Korea
6 shared publications - Kawngwoo Park
Department of Neurosurgery, Gachon University Gil Medical Center, Gachon University College of Medicine, 24, Namdong-Daero 774Beon-Gil, Namdong-Gu, Incheon, Republic of Korea
6 shared publications - Jae Meen Lee
Department of Neurosurgery and Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
5 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by XMLink in Journal of Korean Medical Science
- Vol. 41 (7) , e76
Single-Fraction Stereotactic Radiosurgery for Benign Perioptic Meningiomas: A Strategy for Long-Term Tumor Control and Radiation-Induced Optic Neuropathy Avoidance With a 10-Year Follow-up
Lee EJ, et al. J Korean Med Sci. 2026 Feb;41(7):e76. https://doi.org/10.3346/jkms.2026.41.e76
- 1 January 2026
- Published by XMLink in Journal of Korean Medical Science
- Vol. 41 (7) , e76
Open AccessSingle-Fraction Stereotactic Radiosurgery for Benign Perioptic Meningiomas: A Strategy for Long-Term Tumor Control and Radiation-Induced Optic Neuropathy Avoidance With a 10-Year Follow-up
Lee EJ, et al. J Korean Med Sci. 2026 Feb;41(7):e76. https://doi.org/10.3346/jkms.2026.41.e76
- Open Access
- 30 June 2025
- Published by The Korean Society of Stereotactic and Functional Neurosurgery in Neurofunction
- Vol. 21 (1) , 1-4
Physics and radiobiology of radiosurgery
Radiosurgery, a high-precision, high-dose modality, has revolutionized the field of radiation treatment. The physics of radiosurgery is integral to its design and commissioning. The technology relies on three-dimensional imaging, immobilization, setup, and patient positioning to maintain accuracy within the sub-millimeter range. However, it is particularly important to understand the physical processes causing biological effects. Stereotactic radiosurgery (SRS) currently plays a major role in the treatment of brain tumors due to its ability to precisely and accurately deliver a high dose of radiation to a target, effectively ablating viable tumors while minimizing the dose and preventing damage in surrounding normal tissue. The biological mechanisms underlying these new modalities have not been fully elucidated. Evidence now indicates that SRS with doses higher than about 10 Gy per fraction induces vascular damage in tumors, subsequently causing secondary and additional tumor cell death. The ensuing degradation of tumor cells then releases massive amounts of tumor-specific antigens, thereby elevating the antitumor immune response and suppressing the recurrence of tumors and metastasis. The radiobiology of radiosurgery is thus a complex interplay of physical precision and biological responses, making it a powerful tool in the fight against cancer.
- 30 June 2025
- Published by The Korean Society of Stereotactic and Functional Neurosurgery in Neurofunction
- Vol. 21 (1) , 1-4
Open AccessPhysics and radiobiology of radiosurgery
Radiosurgery, a high-precision, high-dose modality, has revolutionized the field of radiation treatment. The physics of radiosurgery is integral to its design and commissioning. The technology relies on three-dimensional imaging, immobilization, setup, and patient positioning to maintain accuracy within the sub-millimeter range. However, it is particularly important to understand the physical processes causing biological effects. Stereotactic radiosurgery (SRS) currently plays a major role in the treatment of brain tumors due to its ability to precisely and accurately deliver a high dose of radiation to a target, effectively ablating viable tumors while minimizing the dose and preventing damage in surrounding normal tissue. The biological mechanisms underlying these new modalities have not been fully elucidated. Evidence now indicates that SRS with doses higher than about 10 Gy per fraction induces vascular damage in tumors, subsequently causing secondary and additional tumor cell death. The ensuing degradation of tumor cells then releases massive amounts of tumor-specific antigens, thereby elevating the antitumor immune response and suppressing the recurrence of tumors and metastasis. The radiobiology of radiosurgery is thus a complex interplay of physical precision and biological responses, making it a powerful tool in the fight against cancer.
- Open Access
- 29 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-9
Diagnosis of trigeminal neuralgia based on plain skull radiography using convolutional neural network
This study aimed to determine whether trigeminal neuralgia can be diagnosed using convolutional neural networks (CNNs) based on plain X-ray skull images. A labeled dataset of 166 skull images from patients aged over 16 years with trigeminal neuralgia was compiled, alongside a control dataset of 498 images from patients with unruptured intracranial aneurysms. The images were randomly partitioned into training, validation, and test datasets in a 6:2:2 ratio. Classifier performance was assessed using accuracy and the area under the receiver operating characteristic (AUROC) curve. Gradient-weighted class activation mapping was applied to identify regions of interest. External validation was conducted using a dataset obtained from another institution. The CNN achieved an overall accuracy of 87.2%, with sensitivity and specificity of 0.72 and 0.91, respectively, and an AUROC of 0.90 on the test dataset. In most cases, the sphenoid body and clivus were identified as key areas for predicting trigeminal neuralgia. Validation on the external dataset yielded an accuracy of 71.0%, highlighting the potential of deep learning-based models in distinguishing X-ray skull images of patients with trigeminal neuralgia from those of control individuals. Our preliminary results suggest that plain x-ray can be potentially used as an adjunct to conventional MRI, ideally with CISS sequences, to aid in the clinical diagnosis of TN. Further refinement could establish this approach as a valuable screening tool.
- 29 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-9
Open AccessDiagnosis of trigeminal neuralgia based on plain skull radiography using convolutional neural network
This study aimed to determine whether trigeminal neuralgia can be diagnosed using convolutional neural networks (CNNs) based on plain X-ray skull images. A labeled dataset of 166 skull images from patients aged over 16 years with trigeminal neuralgia was compiled, alongside a control dataset of 498 images from patients with unruptured intracranial aneurysms. The images were randomly partitioned into training, validation, and test datasets in a 6:2:2 ratio. Classifier performance was assessed using accuracy and the area under the receiver operating characteristic (AUROC) curve. Gradient-weighted class activation mapping was applied to identify regions of interest. External validation was conducted using a dataset obtained from another institution. The CNN achieved an overall accuracy of 87.2%, with sensitivity and specificity of 0.72 and 0.91, respectively, and an AUROC of 0.90 on the test dataset. In most cases, the sphenoid body and clivus were identified as key areas for predicting trigeminal neuralgia. Validation on the external dataset yielded an accuracy of 71.0%, highlighting the potential of deep learning-based models in distinguishing X-ray skull images of patients with trigeminal neuralgia from those of control individuals. Our preliminary results suggest that plain x-ray can be potentially used as an adjunct to conventional MRI, ideally with CISS sequences, to aid in the clinical diagnosis of TN. Further refinement could establish this approach as a valuable screening tool.
- Open Access
- 1 January 2025
- Published by XMLink in Journal of Korean Medical Science
- Vol. 40 (32) , e195
Fractionated Gamma Knife Radiosurgery as a Primary Treatment for Large Brain Metastases
Myeong HS, et al. J Korean Med Sci. 2025 Jun;40:e195. https://doi.org/10.3346/jkms.2025.40.e195
- 1 January 2025
- Published by XMLink in Journal of Korean Medical Science
- Vol. 40 (32) , e195
Open AccessFractionated Gamma Knife Radiosurgery as a Primary Treatment for Large Brain Metastases
Myeong HS, et al. J Korean Med Sci. 2025 Jun;40:e195. https://doi.org/10.3346/jkms.2025.40.e195
- Open Access
- 1 January 2024
- Published by XMLink in Journal of Korean Medical Science
- Vol. 39 (32) , e229
Long-Term Outcomes of Gamma Knife Radiosurgery for Cerebral Cavernous Malformations: 10 Years and Beyond
Myeong HS, et al. J Korean Med Sci. 2024 Jul;39:e229. https://doi.org/10.3346/jkms.2024.39.e229
- 1 January 2024
- Published by XMLink in Journal of Korean Medical Science
- Vol. 39 (32) , e229
Open AccessLong-Term Outcomes of Gamma Knife Radiosurgery for Cerebral Cavernous Malformations: 10 Years and Beyond
Myeong HS, et al. J Korean Med Sci. 2024 Jul;39:e229. https://doi.org/10.3346/jkms.2024.39.e229
- Open Access
- 1 January 2024
- Published by XMLink in Journal of Korean Medical Science
- Vol. 39 (29) , e217
Long-Term Outcome of Time-Staged Gamma Knife Radiosurgery for Large Arteriovenous Malformations
Myeong HS, et al. J Korean Med Sci. 2024 Jul;39:e217. https://doi.org/10.3346/jkms.2024.39.e217
- 1 January 2024
- Published by XMLink in Journal of Korean Medical Science
- Vol. 39 (29) , e217
Open AccessLong-Term Outcome of Time-Staged Gamma Knife Radiosurgery for Large Arteriovenous Malformations
Myeong HS, et al. J Korean Med Sci. 2024 Jul;39:e217. https://doi.org/10.3346/jkms.2024.39.e217
- 7 February 2023
- Published by Wiley in Medical Physics
- Vol. 50 (6) , 3816-3824
Consistency of dose rates after applying machine‐specific reference correction factors for the gamma knife 16 mm collimator field
Background: The machine-specific reference (msr) correction factors (k(Qmsr,Q0)(fmsr,fref)) were introduced in International Atomic Energy Agency (IAEA) Technical Report Series 483 (TRS-483) for reference dosimetry of small fields. Several correction factor sets exist for a Leksell Gamma Knife (GK) Perfexion or Icon. Nevertheless, experiments have not rigorously validated the correction factors from different studies. Purpose: This study aimed to assess the role and accuracy of k(Qmsr,Q0)(fmsr,fref) values in determining the absorbed dose rates to water in the reference dosimetry of Gamma Knife. Methods: The dose rates in the 16 mm collimator field of a GK were determined following the international code of practices with three ionization chambers: PTW T31010, PTW T31016 (PTW Freiberg GmbH, New York, NY), and Exradin A16 (Standard Imaging, Inc., Middleton, WI). A chamber was placed at the center of a solid water phantom (Elekta AB, Stockholm, Sweden) using a detector-specific insert. The reference point of the ionization chamber was confirmed using cone-beam CT images. Consistency checks were repeated five times at a GK site and performed once at seven GK sites. Correction factors from six simulations reported in previous studies were employed. Variations in the dose rates and relative dose rates before and after applying the k(Qmsr,Q0)(fmsr,fref) were statistically compared. Results: The standard deviation of the dose rates measured by the three chambers decreased significantly after any correction method was applied (p = 0.000). When the correction factors of all studies were averaged, the standard deviation was reduced significantly more than when any single correction method was applied (p <= 0.030), except for the IAEA TRS-483 correction factors (p = 0.148). Before any correction was applied, there were statistically significant differences among the relative dose rates measured by the three chambers (p = 0.000). None of the single correction methods could remove the differences among the ionization chambers (p <= 0.038). After TRS-483 correction, the dose rate of Exradin A16 differed from those of the other two chambers (p <= 0.025). After the averaged factors were applied, there were no statistically significant differences between any pairs of chambers according to Scheffe's post hoc analyses (p >= 0.051); however, PTW T31010 differed from PTW 31016 according to Tukey's HSD analyses (p = 0.040). Conclusion: The k(Qmsr,Q0)(fmsr,fref) significantly reduced variations in the dose rates measured by the three ionization chambers. The mean correction factors of the six simulations produced the most consistent results, but this finding was not explicitly proven in the statistical analyses.
- 7 February 2023
- Published by Wiley in Medical Physics
- Vol. 50 (6) , 3816-3824
Consistency of dose rates after applying machine‐specific reference correction factors for the gamma knife 16 mm collimator field
Background: The machine-specific reference (msr) correction factors (k(Qmsr,Q0)(fmsr,fref)) were introduced in International Atomic Energy Agency (IAEA) Technical Report Series 483 (TRS-483) for reference dosimetry of small fields. Several correction factor sets exist for a Leksell Gamma Knife (GK) Perfexion or Icon. Nevertheless, experiments have not rigorously validated the correction factors from different studies. Purpose: This study aimed to assess the role and accuracy of k(Qmsr,Q0)(fmsr,fref) values in determining the absorbed dose rates to water in the reference dosimetry of Gamma Knife. Methods: The dose rates in the 16 mm collimator field of a GK were determined following the international code of practices with three ionization chambers: PTW T31010, PTW T31016 (PTW Freiberg GmbH, New York, NY), and Exradin A16 (Standard Imaging, Inc., Middleton, WI). A chamber was placed at the center of a solid water phantom (Elekta AB, Stockholm, Sweden) using a detector-specific insert. The reference point of the ionization chamber was confirmed using cone-beam CT images. Consistency checks were repeated five times at a GK site and performed once at seven GK sites. Correction factors from six simulations reported in previous studies were employed. Variations in the dose rates and relative dose rates before and after applying the k(Qmsr,Q0)(fmsr,fref) were statistically compared. Results: The standard deviation of the dose rates measured by the three chambers decreased significantly after any correction method was applied (p = 0.000). When the correction factors of all studies were averaged, the standard deviation was reduced significantly more than when any single correction method was applied (p <= 0.030), except for the IAEA TRS-483 correction factors (p = 0.148). Before any correction was applied, there were statistically significant differences among the relative dose rates measured by the three chambers (p = 0.000). None of the single correction methods could remove the differences among the ionization chambers (p <= 0.038). After TRS-483 correction, the dose rate of Exradin A16 differed from those of the other two chambers (p <= 0.025). After the averaged factors were applied, there were no statistically significant differences between any pairs of chambers according to Scheffe's post hoc analyses (p >= 0.051); however, PTW T31010 differed from PTW 31016 according to Tukey's HSD analyses (p = 0.040). Conclusion: The k(Qmsr,Q0)(fmsr,fref) significantly reduced variations in the dose rates measured by the three ionization chambers. The mean correction factors of the six simulations produced the most consistent results, but this finding was not explicitly proven in the statistical analyses.
- Open Access
- 7 January 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (4)
Optimal mask fixation method for frameless radiosurgery with Leksell Gamma Knife IconTM
The Leksell Gamma Knife (LGK) IconTM is used for mask‐based and frame‐based fixation. The mask fixation provides a noninvasive method. However, an optimal mask fixation method is yet to be established. We evaluated the characteristics of three mask fixation methods (Plain, Folded, and Wide) for the LGK IconTM. Force‐sensitive resistor sensors were attached to the forehead, supraorbital, zygoma, mandible, and occipital bone of the phantom, and digital humidity and temperature sensors were attached to both temporal lobes. Cone‐beam computed tomography (CBCT) and high‐definition motion management (HDMM) for each mask fixation method were used to evaluate the phantom motion during the initial application. Subsequently, the mask was removed and reapplied on the second (1st reapplication) and third days (2nd reapplication). In the initial application, forces acting on most portions of the phantom were stabilized within 1.5 h. The largest force acted on the occipital bone for the Plain and Wide methods and on the mandible for the Folded method. The temperature rapidly approaches the initial temperature, whereas the humidity gradually approached the initial humidity in all fixation methods. The Folded method exhibited a significantly lower translation along the Y‐axis of the Leksell coordinate system, and rotations along all axes were under 0.5°. The HDMM values remained at 0.1 mm for all fixation methods. In the reapplications, the force acting on the occipital bone was significantly greater than that during the initial application for all mask fixation methods; the temperature and humidity remained unchanged. All mask fixation methods in the 1st reapplication were not significantly different from those in the 2nd reapplication. The Folded method is recommended as an optimal mask fixation for patients who require tight fixation; the Wide method can be considered if patient comfort is a priority.
- 7 January 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (4)
Open AccessOptimal mask fixation method for frameless radiosurgery with Leksell Gamma Knife IconTM
The Leksell Gamma Knife (LGK) IconTM is used for mask‐based and frame‐based fixation. The mask fixation provides a noninvasive method. However, an optimal mask fixation method is yet to be established. We evaluated the characteristics of three mask fixation methods (Plain, Folded, and Wide) for the LGK IconTM. Force‐sensitive resistor sensors were attached to the forehead, supraorbital, zygoma, mandible, and occipital bone of the phantom, and digital humidity and temperature sensors were attached to both temporal lobes. Cone‐beam computed tomography (CBCT) and high‐definition motion management (HDMM) for each mask fixation method were used to evaluate the phantom motion during the initial application. Subsequently, the mask was removed and reapplied on the second (1st reapplication) and third days (2nd reapplication). In the initial application, forces acting on most portions of the phantom were stabilized within 1.5 h. The largest force acted on the occipital bone for the Plain and Wide methods and on the mandible for the Folded method. The temperature rapidly approaches the initial temperature, whereas the humidity gradually approached the initial humidity in all fixation methods. The Folded method exhibited a significantly lower translation along the Y‐axis of the Leksell coordinate system, and rotations along all axes were under 0.5°. The HDMM values remained at 0.1 mm for all fixation methods. In the reapplications, the force acting on the occipital bone was significantly greater than that during the initial application for all mask fixation methods; the temperature and humidity remained unchanged. All mask fixation methods in the 1st reapplication were not significantly different from those in the 2nd reapplication. The Folded method is recommended as an optimal mask fixation for patients who require tight fixation; the Wide method can be considered if patient comfort is a priority.
- Open Access
- 1 January 2023
- Published by XMLink in Journal of Korean Medical Science
- Vol. 38 (40) , e332
Long-Term Outcome of Unilateral Acoustic Neuromas With or Without Hearing Loss: Over 10 Years and Beyond After Gamma Knife Radiosurgery
Park HR, et al. J Korean Med Sci. 2023 Oct;38(40):e332. https://doi.org/10.3346/jkms.2023.38.e332
- 1 January 2023
- Published by XMLink in Journal of Korean Medical Science
- Vol. 38 (40) , e332
Open AccessLong-Term Outcome of Unilateral Acoustic Neuromas With or Without Hearing Loss: Over 10 Years and Beyond After Gamma Knife Radiosurgery
Park HR, et al. J Korean Med Sci. 2023 Oct;38(40):e332. https://doi.org/10.3346/jkms.2023.38.e332
- Open Access
- 1 November 2022
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 65 (6) , 861-867
Preliminary Study on Natural Killer Cell Activity for Interferon-Gamma Production after Gamma Knife Radiosurgery for Brain Tumors
Objective : High-dose radiation is well known to induce and modulate the immune system. This study was performed to evaluate the correlation between clinical outcomes and changes in natural killer cell activity (NKA) after Gamma Knife Radiosurgery (GKS) in patients with brain cancer.Methods : We performed an open-label, prospective, cross-sectional study of 38 patients who were treated with GKS for brain tumors, including metastatic and benign brain tumors. All of the patients underwent GKS, and blood samples were collected before and after GKS. NKA was measured using an enzyme-linked immunosorbent assay kit, to measure interferon-gamma (IFNγ) secreted by ex vivo-stimulated NK cells from whole blood. We explored the correlations between NK cell-produced IFNγ (NKA-IFNγ) levels and clinical parameters of patients who were treated with GKS for brain tumors.Results : NKA-IFNγ levels were decreased in metastatic brain tumor patients compared to those with benign brain tumors (p<0.0001). All the patients who used steroid treatment to reduce brain swelling after GKS had an NKA-IFNγ level of zero except one patient. High NKA-IFNγ levels were not associated with a rapid decrease in brain metastasis and did not increase after GKS.Conclusion : The activity of NK cells in metastatic brain tumors decreased more than that in benign brain tumors after GKS.
- 1 November 2022
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 65 (6) , 861-867
Open AccessPreliminary Study on Natural Killer Cell Activity for Interferon-Gamma Production after Gamma Knife Radiosurgery for Brain Tumors
Objective : High-dose radiation is well known to induce and modulate the immune system. This study was performed to evaluate the correlation between clinical outcomes and changes in natural killer cell activity (NKA) after Gamma Knife Radiosurgery (GKS) in patients with brain cancer.Methods : We performed an open-label, prospective, cross-sectional study of 38 patients who were treated with GKS for brain tumors, including metastatic and benign brain tumors. All of the patients underwent GKS, and blood samples were collected before and after GKS. NKA was measured using an enzyme-linked immunosorbent assay kit, to measure interferon-gamma (IFNγ) secreted by ex vivo-stimulated NK cells from whole blood. We explored the correlations between NK cell-produced IFNγ (NKA-IFNγ) levels and clinical parameters of patients who were treated with GKS for brain tumors.Results : NKA-IFNγ levels were decreased in metastatic brain tumor patients compared to those with benign brain tumors (p<0.0001). All the patients who used steroid treatment to reduce brain swelling after GKS had an NKA-IFNγ level of zero except one patient. High NKA-IFNγ levels were not associated with a rapid decrease in brain metastasis and did not increase after GKS.Conclusion : The activity of NK cells in metastatic brain tumors decreased more than that in benign brain tumors after GKS.