Anna Turyanskaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna Turyanskaya has a total of 107 co-authors. Here are the top co-authors by number of shared publications:
- Christina Streli
Atominstitut, TU Wien, Stadionallee 2, 1020 Vienna, Austria
15 shared publications - Mirjam Rauwolf
Atominstitut, TU Wien, Stadionallee 2, 1020 Vienna, Austria
10 shared publications Peter Wobrauschek
TU Wien, Atominstitut, Stadionallee 2, Vienna, 1020, Austria
6 shared publicationsPaul Roschger
Ludwig Boltzmann Institute of Osteology at the Hanusch Hospital of OEGK and AUVA Trauma Centre Meidling, 1140 Vienna, Austria
5 shared publicationsMirjam Rauwolf
TU Wien, Atominstitut, Stadionallee 2, Vienna, 1020, Austria
4 shared publicationsRolf Simon
Karlsruher Institute for Technology (KIT), ANKA Synchrotron Radiation Source, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen, Karlsruhe, 76344, Germany
4 shared publications
Latest Publications
- Open Access
- 1 July 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (14) , 4683-4699
Cross-modality imaging of bisphosphonate-treated murine jawbones
In this proof-of-principle study, we established and implemented a cross-modality imaging (CMI) pipeline to characterize and compare bisphosphonate (BIS)-treated jawbones of Sprague-Dawley rats after tooth extraction after physical therapies (photobiomodulation and extracorporeal shockwave therapy (PBMT and ESWT)). We showcase the feasibility of such a CMI approach and its compatibility across imaging modalities to probe the same region of interest (ROI) of the same jawbone. Jawbones were imaged in toto in 3D using micro-Computed Tomography to identify ROIs for subsequent sequential 2D analysis using well-established technologies such as Atomic Force Microscopy and Scanning Electron Microscopy, and recent imaging approaches in biomedical settings, such as micro-X-Ray Fluorescence Spectroscopy. By combining these four modalities, multiscale information on the morphology, topography, mechanical stiffness (Young's modulus), and calcium, zinc and phosphorus concentrations of the bone was collected. Based on the CMI pipeline, we characterized and compared the jawbones of a previously published clinically relevant rat model of BIS-related osteonecrosis of the jawbone (BRONJ) before and after treatment with BISs, PBMT and ESWT. While we did not find that physical therapies altered the mechanical and elemental jawbone parameters with significance (probably due to the small sample size of only up to 5 samples per group), both ESWT and PBMT reduced pore thicknesses and bone-to-enamel distances significantly compared to the controls. Although focused on BIS-treated jawbones, the established CMI platform can be beneficial in the study of bone-related diseases in general (such as osteoarthritis or -porosis) to acquire complementary hallmarks and better characterize disease status and alleviation potentials.
- 1 July 2021
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (14) , 4683-4699
Open AccessCross-modality imaging of bisphosphonate-treated murine jawbones
In this proof-of-principle study, we established and implemented a cross-modality imaging (CMI) pipeline to characterize and compare bisphosphonate (BIS)-treated jawbones of Sprague-Dawley rats after tooth extraction after physical therapies (photobiomodulation and extracorporeal shockwave therapy (PBMT and ESWT)). We showcase the feasibility of such a CMI approach and its compatibility across imaging modalities to probe the same region of interest (ROI) of the same jawbone. Jawbones were imaged in toto in 3D using micro-Computed Tomography to identify ROIs for subsequent sequential 2D analysis using well-established technologies such as Atomic Force Microscopy and Scanning Electron Microscopy, and recent imaging approaches in biomedical settings, such as micro-X-Ray Fluorescence Spectroscopy. By combining these four modalities, multiscale information on the morphology, topography, mechanical stiffness (Young's modulus), and calcium, zinc and phosphorus concentrations of the bone was collected. Based on the CMI pipeline, we characterized and compared the jawbones of a previously published clinically relevant rat model of BIS-related osteonecrosis of the jawbone (BRONJ) before and after treatment with BISs, PBMT and ESWT. While we did not find that physical therapies altered the mechanical and elemental jawbone parameters with significance (probably due to the small sample size of only up to 5 samples per group), both ESWT and PBMT reduced pore thicknesses and bone-to-enamel distances significantly compared to the controls. Although focused on BIS-treated jawbones, the established CMI platform can be beneficial in the study of bone-related diseases in general (such as osteoarthritis or -porosis) to acquire complementary hallmarks and better characterize disease status and alleviation potentials.
- Open Access
- 26 May 2021
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 3 (3) , 100182
Thickness determination of the tidemark of human articular cartilage using high-resolution micro-XRF imaging of zinc and lead
- 26 May 2021
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 3 (3) , 100182
Open AccessThickness determination of the tidemark of human articular cartilage using high-resolution micro-XRF imaging of zinc and lead
- Open Access
- 5 May 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (7) , 1512-1523
Correlation of μXRF and LA-ICP-MS in the analysis of a human bone-cartilage sample
In this study we combined μXRF and LA-ICP-MS on the very same human femoral head sample. Obtained spatial elemental distributions within bone and cartilage tissues are accompanied by absolute quantitative data.
- 5 May 2021
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 36 (7) , 1512-1523
Open AccessCorrelation of μXRF and LA-ICP-MS in the analysis of a human bone-cartilage sample
In this study we combined μXRF and LA-ICP-MS on the very same human femoral head sample. Obtained spatial elemental distributions within bone and cartilage tissues are accompanied by absolute quantitative data.
- Open Access
- 6 May 2020
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 100 (11) , 4226-4236
Total reflection X‐ray fluorescence analysis of elemental composition of herbal infusions and teas
BACKGROUND: The elemental composition of herbal infusions and teas has not been sufficiently investigated. It could potentially be used for defining fingerprints for individual herbal / tea infusions, differentiation of botanical families, detecting the influence of packaging, and other purposes. The objective of this study was to determine the elemental composition, including the trace element content, of various herbal infusions and teas by means of total reflection X‐ray fluorescence analysis (TXRF), with a chemometrics approach using principal component analysis (PCA).RESULTS: This study determined the elemental composition of various herbal infusions and teas, including trace elements, using total reflection X‐ray fluorescence (TXRF). The methodology for the sample preparation was established, including the multiple‐steepings procedure for the two tea samples (Oolong and Pu‐erh). Data from 29 samples were collected. We hypothesized that the elemental content of infusions could reflect certain features, such as the influence of processing and the type of tea.CONCLUSION: A chemometric approach (PCA) was applied, and differences between teas and herbal infusions were found. This was further corroborated by explicit differentiation of one botanical family, Theaceae. The influence of packaging (tea bags) on herbal material was identified. The three types of tea (Camellia sinensis) appeared to be separated with PCA, and elemental concentrations in Pu‐erh changed with multiple steepings.
- 6 May 2020
- Published by Wiley in Journal of the Science of Food and Agriculture
- Vol. 100 (11) , 4226-4236
Open AccessTotal reflection X‐ray fluorescence analysis of elemental composition of herbal infusions and teas
BACKGROUND: The elemental composition of herbal infusions and teas has not been sufficiently investigated. It could potentially be used for defining fingerprints for individual herbal / tea infusions, differentiation of botanical families, detecting the influence of packaging, and other purposes. The objective of this study was to determine the elemental composition, including the trace element content, of various herbal infusions and teas by means of total reflection X‐ray fluorescence analysis (TXRF), with a chemometrics approach using principal component analysis (PCA).RESULTS: This study determined the elemental composition of various herbal infusions and teas, including trace elements, using total reflection X‐ray fluorescence (TXRF). The methodology for the sample preparation was established, including the multiple‐steepings procedure for the two tea samples (Oolong and Pu‐erh). Data from 29 samples were collected. We hypothesized that the elemental content of infusions could reflect certain features, such as the influence of processing and the type of tea.CONCLUSION: A chemometric approach (PCA) was applied, and differences between teas and herbal infusions were found. This was further corroborated by explicit differentiation of one botanical family, Theaceae. The influence of packaging (tea bags) on herbal material was identified. The three types of tea (Camellia sinensis) appeared to be separated with PCA, and elemental concentrations in Pu‐erh changed with multiple steepings.
- Open Access
- 14 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-9
Detection and imaging of gadolinium accumulation in human bone tissue by micro- and submicro-XRF
Gadolinium-based contrast agents (GBCAs) are frequently used in patients undergoing magnetic resonance imaging. In GBCAs gadolinium (Gd) is present in a bound chelated form. Gadolinium is a rare-earth element, which is normally not present in human body. Though the blood elimination half-life of contrast agents is about 90 minutes, recent studies demonstrated that some tissues retain gadolinium, which might further pose a health threat due to toxic effects of free gadolinium. It is known that the bone tissue can serve as a gadolinium depot, but so far only bulk measurements were performed. Here we present a summary of experiments in which for the first time we mapped gadolinium in bone biopsy from a male patient with idiopathic osteoporosis (without indication of renal impairment), who received MRI 8 months prior to biopsy. In our studies performed by means of synchrotron radiation induced micro- and submicro-X-ray fluorescence spectroscopy (SR-XRF), gadolinium was detected in human cortical bone tissue. The distribution of gadolinium displays a specific accumulation pattern. Correlation of elemental maps obtained at ANKA synchrotron with qBEI images (quantitative backscattered electron imaging) allowed assignment of Gd structures to the histological bone structures. Follow-up beamtimes at ESRF and Diamond Light Source using submicro-SR-XRF allowed resolving thin Gd structures in cortical bone, as well as correlating them with calcium and zinc.
- 14 April 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-9
Open AccessDetection and imaging of gadolinium accumulation in human bone tissue by micro- and submicro-XRF
Gadolinium-based contrast agents (GBCAs) are frequently used in patients undergoing magnetic resonance imaging. In GBCAs gadolinium (Gd) is present in a bound chelated form. Gadolinium is a rare-earth element, which is normally not present in human body. Though the blood elimination half-life of contrast agents is about 90 minutes, recent studies demonstrated that some tissues retain gadolinium, which might further pose a health threat due to toxic effects of free gadolinium. It is known that the bone tissue can serve as a gadolinium depot, but so far only bulk measurements were performed. Here we present a summary of experiments in which for the first time we mapped gadolinium in bone biopsy from a male patient with idiopathic osteoporosis (without indication of renal impairment), who received MRI 8 months prior to biopsy. In our studies performed by means of synchrotron radiation induced micro- and submicro-X-ray fluorescence spectroscopy (SR-XRF), gadolinium was detected in human cortical bone tissue. The distribution of gadolinium displays a specific accumulation pattern. Correlation of elemental maps obtained at ANKA synchrotron with qBEI images (quantitative backscattered electron imaging) allowed assignment of Gd structures to the histological bone structures. Follow-up beamtimes at ESRF and Diamond Light Source using submicro-SR-XRF allowed resolving thin Gd structures in cortical bone, as well as correlating them with calcium and zinc.
- 11 February 2020
- Published by Wiley in X-Ray Spectrometry
- Vol. 49 (3) , 424-433
Determining elemental strontium distribution in rat bones treated with strontium ranelate and strontium citrate using 2D micro‐XRF and 3D dual energy K‐edge subtraction synchrotron imaging
Strontium‐based medications, such as strontium ranelate, have been suggested to have therapeutic effects in patients with osteoporosis. Strontium salts available off‐shelf in stores across North America are assumed to provide similar effects as strontium ranelate and thus should lead to similar distributions of elemental strontium incorporated in bone. The objective of this study was to compare the spatial distribution of strontium in animal bones following the administration of strontium ranelate and strontium citrate. Seventeen‐week‐old Sprague–Dawley rats were split into three groups over 10 weeks and given 625 mg/kg/day of strontium ranelate and 676 mg/kg/day of strontium citrate; the control group received no additional supplementary strontium. The humeri were collected from all animals, and strontium distribution was mapped using 2D micro‐XRF and 3D dual energy K‐edge subtraction (KES) imaging. 2D and 3D elemental mapping methods demonstrated that strontium delivered during treatment by both salts had the same spatial distribution. 3D elemental strontium maps of treated animal bones showed that strontium was largely observed in the trabecular regions under the epiphyseal (growth) plate. The thickness of the strontium layers in both the strontium ranelate and strontium citrate sample was not significantly different ( p = .9201). 2D micro‐XRF and 3D dual‐energy KES images effectively elucidated the spatial distribution of elemental strontium in calcified tissue. These methods provide a novel approach to evaluating the potential efficacy of strontium supplements in the treatment of osteoporosis.
- 11 February 2020
- Published by Wiley in X-Ray Spectrometry
- Vol. 49 (3) , 424-433
Determining elemental strontium distribution in rat bones treated with strontium ranelate and strontium citrate using 2D micro‐XRF and 3D dual energy K‐edge subtraction synchrotron imaging
Strontium‐based medications, such as strontium ranelate, have been suggested to have therapeutic effects in patients with osteoporosis. Strontium salts available off‐shelf in stores across North America are assumed to provide similar effects as strontium ranelate and thus should lead to similar distributions of elemental strontium incorporated in bone. The objective of this study was to compare the spatial distribution of strontium in animal bones following the administration of strontium ranelate and strontium citrate. Seventeen‐week‐old Sprague–Dawley rats were split into three groups over 10 weeks and given 625 mg/kg/day of strontium ranelate and 676 mg/kg/day of strontium citrate; the control group received no additional supplementary strontium. The humeri were collected from all animals, and strontium distribution was mapped using 2D micro‐XRF and 3D dual energy K‐edge subtraction (KES) imaging. 2D and 3D elemental mapping methods demonstrated that strontium delivered during treatment by both salts had the same spatial distribution. 3D elemental strontium maps of treated animal bones showed that strontium was largely observed in the trabecular regions under the epiphyseal (growth) plate. The thickness of the strontium layers in both the strontium ranelate and strontium citrate sample was not significantly different ( p = .9201). 2D micro‐XRF and 3D dual‐energy KES images effectively elucidated the spatial distribution of elemental strontium in calcified tissue. These methods provide a novel approach to evaluating the potential efficacy of strontium supplements in the treatment of osteoporosis.
- 1 July 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 149, 200-205
Elemental imaging of trace elements in bone samples using micro and nano-X-ray fluorescence spectrometry
- 1 July 2019
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 149, 200-205
Elemental imaging of trace elements in bone samples using micro and nano-X-ray fluorescence spectrometry
- Open Access
- 1 July 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 897, 114-119
Temporary implementation and testing of a confocal SR-XRF system for bone analysis at the X-ray Fluorescence beamline at Elettra- 1 July 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 897, 114-119
Open AccessTemporary implementation and testing of a confocal SR-XRF system for bone analysis at the X-ray Fluorescence beamline at Elettra - Open Access
- 13 June 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (4) , 1189-1195
Characterization of a submicro-X-ray fluorescence setup on the B16 beamline at Diamond Light Source
An X-ray fluorescence setup has been tested on the B16 beamline at the Diamond Light Source synchrotron with two different excitation energies (12.7 and 17 keV). This setup allows the scanning of thin samples (thicknesses up to several micrometers) with a sub-micrometer resolution (beam size of 500 nm × 600 nm determined with a 50 µm Au wire). Sensitivities and detection limits reaching values of 249 counts s−1 fg−1 and 4 ag in 1000 s, respectively (for As Kα excited with 17 keV), are presented in order to demonstrate the capabilities of this setup. Sample measurements of a human bone and a single cell performed at B16 are presented in order to illustrate the suitability of the setup in biological applications.
- 13 June 2018
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 25 (4) , 1189-1195
Open AccessCharacterization of a submicro-X-ray fluorescence setup on the B16 beamline at Diamond Light Source
An X-ray fluorescence setup has been tested on the B16 beamline at the Diamond Light Source synchrotron with two different excitation energies (12.7 and 17 keV). This setup allows the scanning of thin samples (thicknesses up to several micrometers) with a sub-micrometer resolution (beam size of 500 nm × 600 nm determined with a 50 µm Au wire). Sensitivities and detection limits reaching values of 249 counts s−1 fg−1 and 4 ag in 1000 s, respectively (for As Kα excited with 17 keV), are presented in order to demonstrate the capabilities of this setup. Sample measurements of a human bone and a single cell performed at B16 are presented in order to illustrate the suitability of the setup in biological applications.