Luca Nocetti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Luca Nocetti has a total of 210 co-authors. Here are the top co-authors by number of shared publications:
- Patrizia Baraldi
Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Modena, Italy
5 shared publications - Marco Esposito
S. C. Fisica Sanitaria, Firenze—Azienda Sanitaria USL Toscana Centro, Bagno a Ripoli, Firenze, Italy
4 shared publications - Marco Giannelli
Azienda Ospedaliero-Universitaria Pisana
4 shared publications - Sabrina Morzenti
Medical Physics, San Gerardo Hospital, Monza, Italy
4 shared publications Antonio Ciccarone
A.O.U. Mayer, Firenze, Italy
3 shared publications- Carlo Adolfo Porro
Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, 41125 Modena, Italy
3 shared publications
Latest Publications
- 4 November 2022
- Published by American Chemical Society (ACS) in Environmental Health Perspectives
- Vol. 130 (11) , 117701
Selenium Species in Cerebrospinal Fluid and Hippocampal Volume among Individuals with Mild Cognitive Impairment
- 4 November 2022
- Published by American Chemical Society (ACS) in Environmental Health Perspectives
- Vol. 130 (11) , 117701
Selenium Species in Cerebrospinal Fluid and Hippocampal Volume among Individuals with Mild Cognitive Impairment
- 28 April 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (2) , 279-289
Attenuation assessment of medical protective eyewear: the AVEN experience
The goal of this paper is to test the attenuation capability of seven models of protective eyewear used in routine clinical practice. Scattered radiation from a standard patient was simulated by using a water tank located over the treatment couch of a GE Innova 3100 x-ray angiography system. Seven protective eyewear models were tested using an anthropomorphic phantom mimicking the first operator. At each test, 4 thermoluminiscent dosimeters were placed on the phantom (respectively in front of the protective eyewear, under the eyewear, on the left earpiece and at chest level) in order to have an eyewear-independent reference. A test session without glasses was also acquired. Each model was tested with standard posterior–anterior (PA) projections and the two most common protective eyewear were tested using LAO90° and LAO45°CRA30° projections. A worst-case scenario was created to be sure of having an upper limit for the assessment of eyewear attenuation in routine clinical practice. In PA projections, the absolute attenuation value ranged between 71% and 81%, while relative attenuation between dose measured at eye lens and that measured at eyewear earpiece ranged from 67% to 85%. The slightly wider range was probably due to scatter radiation variability; anyway, differences are still included in the variable uncertainty of experimental measurements. It is worth noting that #3 eyewear model (the one without lateral protection) allows an attenuation similar to that of #5 eyewear model (with 0.5 mm lead lateral protection) in LAO90° and LAO45°CRA30° projections. Despite the experimental limitations, a description of the radiation properties of protective eyewear concerning radiation attenuation can be useful to rely on protection devices which can be used in routine clinical practice.
- 28 April 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (2) , 279-289
Attenuation assessment of medical protective eyewear: the AVEN experience
The goal of this paper is to test the attenuation capability of seven models of protective eyewear used in routine clinical practice. Scattered radiation from a standard patient was simulated by using a water tank located over the treatment couch of a GE Innova 3100 x-ray angiography system. Seven protective eyewear models were tested using an anthropomorphic phantom mimicking the first operator. At each test, 4 thermoluminiscent dosimeters were placed on the phantom (respectively in front of the protective eyewear, under the eyewear, on the left earpiece and at chest level) in order to have an eyewear-independent reference. A test session without glasses was also acquired. Each model was tested with standard posterior–anterior (PA) projections and the two most common protective eyewear were tested using LAO90° and LAO45°CRA30° projections. A worst-case scenario was created to be sure of having an upper limit for the assessment of eyewear attenuation in routine clinical practice. In PA projections, the absolute attenuation value ranged between 71% and 81%, while relative attenuation between dose measured at eye lens and that measured at eyewear earpiece ranged from 67% to 85%. The slightly wider range was probably due to scatter radiation variability; anyway, differences are still included in the variable uncertainty of experimental measurements. It is worth noting that #3 eyewear model (the one without lateral protection) allows an attenuation similar to that of #5 eyewear model (with 0.5 mm lead lateral protection) in LAO90° and LAO45°CRA30° projections. Despite the experimental limitations, a description of the radiation properties of protective eyewear concerning radiation attenuation can be useful to rely on protection devices which can be used in routine clinical practice.
- 20 April 2016
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 39 (2) , 583-589
Reducing absorbed dose to eye lenses in head CT examinations: the effect of bismuth shielding
The eye lens is considered to be among the most radiosensitive human tissues. Brain CT scans may unnecessarily expose it to radiation even if the area of clinical interest is far from the eyes. The aim of this study is to implement a bismuth eye lens shielding system for Head-CT acquisitions in these cases. The study is focused on the assessment of the dosimetric characteristics of the shielding system as well as on its effect on image quality. The shielding system was tested in two set-ups which differ for distance (“contact” and “4 cm” Set up respectively). Scans were performed on a CTDI phantom and an anthropomorphic phantom. A reference set up without shielding system was acquired to establish a baseline. Image quality was assessed by signal (not HU converted), noise and contrast-to-noise ratio (CNR) evaluation. The overall dose reduction was evaluated by measuring the CTDIvol while the eye lens dose reduction was assessed by placing thermoluminescent dosimeters (TLDs) on an anthropomorphic phantom. The image quality analysis exhibits the presence of an artefact that mildly increases the CT number up to 3 cm below the shielding system. Below the artefact, the difference of the Signal and the CNR are negligible between the three different set-ups. Regarding the CTDI, the analysis demonstrates a decrease by almost 12 % (in the “contact” set-up) and 9 % (in the “4 cm” set-up). TLD measurements exhibit an eye lens dose reduction by 28.5 ± 5 and 21.1 ± 5 % respectively at the “contact” and the “4 cm” distance. No relevant artefact was found and image quality was not affected by the shielding system. Significant dose reductions were measured. These features make the shielding set-up useful for clinical implementation in both studied positions.
- 20 April 2016
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 39 (2) , 583-589
Reducing absorbed dose to eye lenses in head CT examinations: the effect of bismuth shielding
The eye lens is considered to be among the most radiosensitive human tissues. Brain CT scans may unnecessarily expose it to radiation even if the area of clinical interest is far from the eyes. The aim of this study is to implement a bismuth eye lens shielding system for Head-CT acquisitions in these cases. The study is focused on the assessment of the dosimetric characteristics of the shielding system as well as on its effect on image quality. The shielding system was tested in two set-ups which differ for distance (“contact” and “4 cm” Set up respectively). Scans were performed on a CTDI phantom and an anthropomorphic phantom. A reference set up without shielding system was acquired to establish a baseline. Image quality was assessed by signal (not HU converted), noise and contrast-to-noise ratio (CNR) evaluation. The overall dose reduction was evaluated by measuring the CTDIvol while the eye lens dose reduction was assessed by placing thermoluminescent dosimeters (TLDs) on an anthropomorphic phantom. The image quality analysis exhibits the presence of an artefact that mildly increases the CT number up to 3 cm below the shielding system. Below the artefact, the difference of the Signal and the CNR are negligible between the three different set-ups. Regarding the CTDI, the analysis demonstrates a decrease by almost 12 % (in the “contact” set-up) and 9 % (in the “4 cm” set-up). TLD measurements exhibit an eye lens dose reduction by 28.5 ± 5 and 21.1 ± 5 % respectively at the “contact” and the “4 cm” distance. No relevant artefact was found and image quality was not affected by the shielding system. Significant dose reductions were measured. These features make the shielding set-up useful for clinical implementation in both studied positions.
- 12 April 2016
- Published by Springer Nature in Brain Topography
- Vol. 29 (5) , 679-692
Brain Activation Patterns Characterizing Different Phases of Motor Action: Execution, Choice and Ideation
Motor behaviour is controlled by a large set of interacting neural structures, subserving the different components involved in hierarchical motor processes. Few studies have investigated the neural substrate of higher-order motor ideation, i.e. the mental operation of conceiving a movement. The aim of this functional magnetic resonance imaging study was to segregate the neural structures involved in motor ideation from those involved in movement choice and execution. An index finger movement paradigm was adopted, including three different conditions: performing a pre-specified movement, choosing and executing a movement and ideating a movement of choice. The tasks involved either the right or left hand, in separate runs. Neuroimaging results were obtained by comparing the different experimental conditions and computing conjunction maps of the right and left hands for each contrast. Pre-specified movement execution was supported by bilateral fronto-parietal motor regions, the cerebellum and putamen. Choosing and executing finger movement involved mainly left fronto-temporal areas and the anterior cingulate. Motor ideation activated almost exclusively left hemisphere regions, including the inferior, middle and superior frontal regions, middle temporal and middle occipital gyri. These findings show that motor ideation is controlled by a cortical network mainly involved in abstract thinking, cognitive and motor control, semantic and visual imagery processes.
- 12 April 2016
- Published by Springer Nature in Brain Topography
- Vol. 29 (5) , 679-692
Brain Activation Patterns Characterizing Different Phases of Motor Action: Execution, Choice and Ideation
Motor behaviour is controlled by a large set of interacting neural structures, subserving the different components involved in hierarchical motor processes. Few studies have investigated the neural substrate of higher-order motor ideation, i.e. the mental operation of conceiving a movement. The aim of this functional magnetic resonance imaging study was to segregate the neural structures involved in motor ideation from those involved in movement choice and execution. An index finger movement paradigm was adopted, including three different conditions: performing a pre-specified movement, choosing and executing a movement and ideating a movement of choice. The tasks involved either the right or left hand, in separate runs. Neuroimaging results were obtained by comparing the different experimental conditions and computing conjunction maps of the right and left hands for each contrast. Pre-specified movement execution was supported by bilateral fronto-parietal motor regions, the cerebellum and putamen. Choosing and executing finger movement involved mainly left fronto-temporal areas and the anterior cingulate. Motor ideation activated almost exclusively left hemisphere regions, including the inferior, middle and superior frontal regions, middle temporal and middle occipital gyri. These findings show that motor ideation is controlled by a cortical network mainly involved in abstract thinking, cognitive and motor control, semantic and visual imagery processes.
- 1 February 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 133
AIFM multicenter intercomparison of MR scanners for proton spectroscopy – preliminary results
- 1 February 2016
- Published by Elsevier in Physica Medica
- Vol. 32, 133
AIFM multicenter intercomparison of MR scanners for proton spectroscopy – preliminary results
- 26 May 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 43 (1) , 213-219
Quality assurance multicenter comparison of different MR scanners for quantitative diffusion-weighted imaging
Purpose To propose a magnetic resonance imaging (MRI) quality assurance procedure that can be used for multicenter comparison of different MR scanners for quantitative diffusion‐weighted imaging (DWI). Materials and Methods Twenty‐six centers (35 MR scanners with field strengths: 1T, 1.5T, and 3T) were enrolled in the study. Two different DWI acquisition series (b‐value ranges 0–1000 and 0–3000 s/mm2, respectively) were performed for each MR scanner. All DWI acquisitions were performed by using a cylindrical doped water phantom. Mean apparent diffusion coefficient (ADC) values as well as ADC values along each of the three main orthogonal directions of the diffusion gradients (x, y, and z) were calculated. Short‐term repeatability of ADC measurement was evaluated for 26 MR scanners. Results A good agreement was found between the nominal and measured mean ADC over all the centers. More than 80% of mean ADC measurements were within 5% from the nominal value, and the highest deviation and overall standard deviation were 9.3% and 3.5%, respectively. Short‐term repeatability of ADC measurement was found <2.5% for all MR scanners. Conclusion A specific and widely accepted protocol for quality controls in DWI is still lacking. The DWI quality assurance protocol proposed in this study can be applied in order to assess the reliability of DWI‐derived indices before tackling single‐ as well as multicenter studies. J. Magn. Reson. Imaging 2015.
- 26 May 2015
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 43 (1) , 213-219
Quality assurance multicenter comparison of different MR scanners for quantitative diffusion-weighted imaging
Purpose To propose a magnetic resonance imaging (MRI) quality assurance procedure that can be used for multicenter comparison of different MR scanners for quantitative diffusion‐weighted imaging (DWI). Materials and Methods Twenty‐six centers (35 MR scanners with field strengths: 1T, 1.5T, and 3T) were enrolled in the study. Two different DWI acquisition series (b‐value ranges 0–1000 and 0–3000 s/mm2, respectively) were performed for each MR scanner. All DWI acquisitions were performed by using a cylindrical doped water phantom. Mean apparent diffusion coefficient (ADC) values as well as ADC values along each of the three main orthogonal directions of the diffusion gradients (x, y, and z) were calculated. Short‐term repeatability of ADC measurement was evaluated for 26 MR scanners. Results A good agreement was found between the nominal and measured mean ADC over all the centers. More than 80% of mean ADC measurements were within 5% from the nominal value, and the highest deviation and overall standard deviation were 9.3% and 3.5%, respectively. Short‐term repeatability of ADC measurement was found <2.5% for all MR scanners. Conclusion A specific and widely accepted protocol for quality controls in DWI is still lacking. The DWI quality assurance protocol proposed in this study can be applied in order to assess the reliability of DWI‐derived indices before tackling single‐ as well as multicenter studies. J. Magn. Reson. Imaging 2015.
- 7 August 2014
- Published by Springer Nature in La radiologia medica
- Vol. 120 (2) , 228-238
Transvaginal ultrasound assessment of uterine scar after previous caesarean section: comparison with 3T-magnetic resonance diffusion tensor imaging
This study aimed to evaluate 3-T magnetic resonance imaging in the analysis of caesarean scars in women with prior caesarean section (pCS) and investigate the potential added value of diffusion tensor imaging (3T-MR-DTI) with fibre tracking reconstruction, compared with transvaginal ultrasound (TVUS).
- 7 August 2014
- Published by Springer Nature in La radiologia medica
- Vol. 120 (2) , 228-238
Transvaginal ultrasound assessment of uterine scar after previous caesarean section: comparison with 3T-magnetic resonance diffusion tensor imaging
This study aimed to evaluate 3-T magnetic resonance imaging in the analysis of caesarean scars in women with prior caesarean section (pCS) and investigate the potential added value of diffusion tensor imaging (3T-MR-DTI) with fibre tracking reconstruction, compared with transvaginal ultrasound (TVUS).
- 1 April 2013
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 31 (3) , 353-358
An algorithm to estimate anatomical connectivity between brain regions using diffusion MRI
- 1 April 2013
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 31 (3) , 353-358
An algorithm to estimate anatomical connectivity between brain regions using diffusion MRI