Ahmad Falahatpisheh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmad Falahatpisheh has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Arash Kheradvar
Department of Radiological Sciences, University of California, Irvine, USA
9 shared publications Elliott M. Groves
University of California, Irvine
4 shared publications- Boyce E. Griffith
Department of Mathematics, University of North Carolina, Chapel Hill, NC, USA
3 shared publications Craig A. Simmons
University of Toronto
3 shared publications- Craig J. Goergen
Weldon School of Biomedical Engineering Purdue University West Lafayette Indiana USA
3 shared publications Frank Baaijens
Eindhoven University of Technology
3 shared publications
Latest Publications
- 1 January 2015
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 49, 264-271
A measure of axisymmetry for vortex rings
- 1 January 2015
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 49, 264-271
A measure of axisymmetry for vortex rings
- 9 December 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (4) , 833-843
Emerging Trends in Heart Valve Engineering: Part I. Solutions for Future
As the first section of a multi-part review series, this section provides an overview of the ongoing research and development aimed at fabricating novel heart valve replacements beyond what is currently available for patients. Here we discuss heart valve replacement options that involve a biological component or process for creation, either in vitro or in vivo (tissue-engineered heart valves), and heart valves that are fabricated from polymeric material that are considered permanent inert materials that may suffice for adults where growth is not required. Polymeric materials provide opportunities for cost-effective heart valves that can be more easily manufactured and can be easily integrated with artificial heart and ventricular assist device technologies. Tissue engineered heart valves show promise as a regenerative patient specific model that could be the future of all valve replacement. Because tissue-engineered heart valves depend on cells for their creation, understanding how cells sense and respond to chemical and physical stimuli in their microenvironment is critical and therefore, is also reviewed.
- 9 December 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (4) , 833-843
Emerging Trends in Heart Valve Engineering: Part I. Solutions for Future
As the first section of a multi-part review series, this section provides an overview of the ongoing research and development aimed at fabricating novel heart valve replacements beyond what is currently available for patients. Here we discuss heart valve replacement options that involve a biological component or process for creation, either in vitro or in vivo (tissue-engineered heart valves), and heart valves that are fabricated from polymeric material that are considered permanent inert materials that may suffice for adults where growth is not required. Polymeric materials provide opportunities for cost-effective heart valves that can be more easily manufactured and can be easily integrated with artificial heart and ventricular assist device technologies. Tissue engineered heart valves show promise as a regenerative patient specific model that could be the future of all valve replacement. Because tissue-engineered heart valves depend on cells for their creation, understanding how cells sense and respond to chemical and physical stimuli in their microenvironment is critical and therefore, is also reviewed.
- 2 December 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (4) , 844-857
Emerging Trends in Heart Valve Engineering: Part II. Novel and Standard Technologies for Aortic Valve Replacement
The engineering of technologies for heart valve replacement (i.e., heart valve engineering) is an exciting and evolving field. Since the first valve replacement, technology has progressed by leaps and bounds. Innovations emerge frequently and supply patients and physicians with new, increasingly efficacious and less invasive treatment options. As much as any other field in medicine the treatment of heart valve disease has experienced a renaissance in the last 10 years. Here we review the currently available technologies and future options in the surgical and transcatheter treatment of aortic valve disease. Different valves from major manufacturers are described in details with their applications.
- 2 December 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (4) , 844-857
Emerging Trends in Heart Valve Engineering: Part II. Novel and Standard Technologies for Aortic Valve Replacement
The engineering of technologies for heart valve replacement (i.e., heart valve engineering) is an exciting and evolving field. Since the first valve replacement, technology has progressed by leaps and bounds. Innovations emerge frequently and supply patients and physicians with new, increasingly efficacious and less invasive treatment options. As much as any other field in medicine the treatment of heart valve disease has experienced a renaissance in the last 10 years. Here we review the currently available technologies and future options in the surgical and transcatheter treatment of aortic valve disease. Different valves from major manufacturers are described in details with their applications.
- 5 November 2014
- Published by Springer Nature in Experiments in Fluids
- Vol. 55 (11) , 1-15
Three-dimensional reconstruction of cardiac flows based on multi-planar velocity fields
- 5 November 2014
- Published by Springer Nature in Experiments in Fluids
- Vol. 55 (11) , 1-15
Three-dimensional reconstruction of cardiac flows based on multi-planar velocity fields
- 7 October 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (4) , 858-870
Emerging Trends in Heart Valve Engineering: Part III. Novel Technologies for Mitral Valve Repair and Replacement
In this portion of an extensive review of heart valve engineering, we focus on the current and emerging technologies and techniques to repair or replace the mitral valve. We begin with a discussion of the currently available mechanical and bioprosthetic mitral valves followed by the rationale and limitations of current surgical mitral annuloplasty methods; a discussion of the technique of neo-chordae fabrication and implantation; a review the procedures and clinical results for catheter-based mitral leaflet repair; a highlight of the motivation for and limitations of catheter-based annular reduction therapies; and introduce the early generation devices for catheter-based mitral valve replacement.
- 7 October 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 43 (4) , 858-870
Emerging Trends in Heart Valve Engineering: Part III. Novel Technologies for Mitral Valve Repair and Replacement
In this portion of an extensive review of heart valve engineering, we focus on the current and emerging technologies and techniques to repair or replace the mitral valve. We begin with a discussion of the currently available mechanical and bioprosthetic mitral valves followed by the rationale and limitations of current surgical mitral annuloplasty methods; a discussion of the technique of neo-chordae fabrication and implantation; a review the procedures and clinical results for catheter-based mitral leaflet repair; a highlight of the motivation for and limitations of catheter-based annular reduction therapies; and introduce the early generation devices for catheter-based mitral valve replacement.
- 1 September 2014
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 60 (5) , 545-552
The Effects of Positioning of Transcatheter Aortic Valves on Fluid Dynamics of the Aortic Root
Transcatheter aortic valve implantation is a novel treatment for severe aortic valve stenosis. Due to the recent use of this technology and the procedural variability, there is very little data that quantify the hemodynamic consequences of variations in valve placement. Changes in aortic wall stresses and fluid retention in the sinuses of Valsalva can have a significant effect on the clinical response a patient has to the procedure. By comprehensively characterizing complex flow in the sinuses of Valsalva using digital particle image velocimetry and an advanced heart-flow simulator, various positions of a deployed transcatheter valve with respect to a bioprosthetic aortic valve (valve-in-valve) were tested in vitro. Displacements of the transcatheter valve were axial and directed below the simulated native valve annulus. It was determined that for both blood residence time and aortic Reynolds stresses, it is optimal to have the annulus of the transcatheter valve deployed as close to the aortic valve annulus as possible.
- 1 September 2014
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 60 (5) , 545-552
The Effects of Positioning of Transcatheter Aortic Valves on Fluid Dynamics of the Aortic Root
Transcatheter aortic valve implantation is a novel treatment for severe aortic valve stenosis. Due to the recent use of this technology and the procedural variability, there is very little data that quantify the hemodynamic consequences of variations in valve placement. Changes in aortic wall stresses and fluid retention in the sinuses of Valsalva can have a significant effect on the clinical response a patient has to the procedure. By comprehensively characterizing complex flow in the sinuses of Valsalva using digital particle image velocimetry and an advanced heart-flow simulator, various positions of a deployed transcatheter valve with respect to a bioprosthetic aortic valve (valve-in-valve) were tested in vitro. Displacements of the transcatheter valve were axial and directed below the simulated native valve annulus. It was determined that for both blood residence time and aortic Reynolds stresses, it is optimal to have the annulus of the transcatheter valve deployed as close to the aortic valve annulus as possible.
- 1 September 2012
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 35, 2-8
High-speed particle image velocimetry to assess cardiac fluid dynamics in vitro: From performance to validation
- 1 September 2012
- Published by Elsevier in European Journal of Mechanics - B/Fluids
- Vol. 35, 2-8
High-speed particle image velocimetry to assess cardiac fluid dynamics in vitro: From performance to validation
- 1 March 2012
- Vol. 21 (2) , 225-233
The Effects of Dynamic Saddle Annulus and Leaflet Length on Transmitral Flow Pattern and Leaflet Stress of a Bileaflet Bioprosthetic Mitral Valve
Background and aim of the study: The study aim was to determine the effect of mitral saddle annulus and leaflet length on peak leaflet stress and transmitral flow pattern when utilizing a novel bileaflet bioprosthetic valve. Methods: A novel valve, which closely mimics the saddle annulus motion of the mitral valve was developed. A series of computational analyses and in-vitro hemodynamic studies was performed to assess the effect of annulus dynamics and leaflet length on stress distribution at the leaflet tips as well as the transmitral flow pattern downstream of the valve. Results: The analysis showed that the dynamic annulus may significantly reduce stress along the tip of the leaflets compared to the rigid annulus in a standard trileaflet valve. The leaflet length may also significantly alter stress distribution over the leaflets by affecting the annulus dynamics. It was shown in vitro that the interaction between the leaflet and the ventricular results in fundamentally distinct transmitral vortex formation patterns. Conclusion: Motion of the mitral saddle annulus along with the leaflet length is a critical factor that minimizes stress distribution at the tips of the leaflets due to a dampening of the pressure load exerted over the valve during the cardiac cycle. The length of the leaflets, and their proximity to the ventricular wall, have been shown to have significant effects on transmitral vortex formation and energy dissipation during blood transfer from the left atrium towards the aorta via left ventricle. The Journal of Heart Valve Disease 2012;21:225-233
- 1 March 2012
- Vol. 21 (2) , 225-233
The Effects of Dynamic Saddle Annulus and Leaflet Length on Transmitral Flow Pattern and Leaflet Stress of a Bileaflet Bioprosthetic Mitral Valve
Background and aim of the study: The study aim was to determine the effect of mitral saddle annulus and leaflet length on peak leaflet stress and transmitral flow pattern when utilizing a novel bileaflet bioprosthetic valve. Methods: A novel valve, which closely mimics the saddle annulus motion of the mitral valve was developed. A series of computational analyses and in-vitro hemodynamic studies was performed to assess the effect of annulus dynamics and leaflet length on stress distribution at the leaflet tips as well as the transmitral flow pattern downstream of the valve. Results: The analysis showed that the dynamic annulus may significantly reduce stress along the tip of the leaflets compared to the rigid annulus in a standard trileaflet valve. The leaflet length may also significantly alter stress distribution over the leaflets by affecting the annulus dynamics. It was shown in vitro that the interaction between the leaflet and the ventricular results in fundamentally distinct transmitral vortex formation patterns. Conclusion: Motion of the mitral saddle annulus along with the leaflet length is a critical factor that minimizes stress distribution at the tips of the leaflets due to a dampening of the pressure load exerted over the valve during the cardiac cycle. The length of the leaflets, and their proximity to the ventricular wall, have been shown to have significant effects on transmitral vortex formation and energy dissipation during blood transfer from the left atrium towards the aorta via left ventricle. The Journal of Heart Valve Disease 2012;21:225-233
- 1 February 2012
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 25 (2) , 220-227
Assessment of Transmitral Vortex Formation in Patients with Diastolic Dysfunction
- 1 February 2012
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 25 (2) , 220-227
Assessment of Transmitral Vortex Formation in Patients with Diastolic Dysfunction
- 17 September 2009
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 46 (1) , 15-23
Numerical investigation of natural convection of Al2O3 nanofluid in vertical annuli
- 17 September 2009
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 46 (1) , 15-23
Numerical investigation of natural convection of Al2O3 nanofluid in vertical annuli