Sabha Raj Arya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sabha Raj Arya has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Rakesh Maurya
Department of Electrical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, India
20 shared publications Rakesh Maurya
Sardar Vallabhbhai National Institute of Technology
18 shared publications- Ashutosh K. Giri
Government Engineering College Bharuch
10 shared publications Khyati D. Mistry
Department of Electrical Engineering, Sardar Vallabhbhai National Institute of Technology, Surat, Gujarat, India
9 shared publicationsPrashant Kumar
School of Sustainability Studies, Symbiosis Skills and Professional University, Pune, Maharashtra, India
9 shared publicationsJayadeep Srikakolapu
Sardar Vallabhbhai National Institute of Technology
8 shared publications
Latest Publications
- 6 April 2026
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 47 (1)
Power quality features in distributed power generation using a gradient adaptive algorithm with optimised PI gain
- 6 April 2026
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 47 (1)
Power quality features in distributed power generation using a gradient adaptive algorithm with optimised PI gain
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 14839-14848
Optimal HONN for Parameter Estimation in Adaptive Speed Control of IRFOC-Based Induction Motor Drives
This paper presents a two-fold control framework for parameter-adaptive indirect rotor field-oriented control (IRFOC) of induction motor drives (IMDs), combining higher-order neural network (HONN)-based estimation with elitist teaching–learning based optimization (ETLBO). Unlike conventional adaptive and neural estimation techniques that rely on multi-layer structures and heuristic tuning, the proposed approach exploits single-layer trainable HONNs, namely Pi–Sigma, Sigma–Pi, and Jordan Pi Sigma neural networks for simultaneous sensorless speed and motor parameter estimation, offering faster learning, improved fault tolerance, and enhanced approximation capability. A key novelty lies in the dual utilization of the non-parametric ETLBO algorithm, which optimally trains the HONN weights and biases while also tuning PI controller gains using the integral time square error (ITSE) criterion, thereby eliminating manual parameter selection and reducing computational burden. Comprehensive validation through statistical indices, dynamic response analysis, MATLAB/Simulink simulations, and d-SPACE Micro-lab box based experimental studies confirms that the ETLBO-optimized JPSNN achieves superior estimation accuracy, faster convergence, and robust dynamic performance across wide operating conditions. The proposed methodology delivers a computationally efficient, fully adaptive, and experimentally verified solution for high-performance sensorless IMD control.
- 9 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 14839-14848
Optimal HONN for Parameter Estimation in Adaptive Speed Control of IRFOC-Based Induction Motor Drives
This paper presents a two-fold control framework for parameter-adaptive indirect rotor field-oriented control (IRFOC) of induction motor drives (IMDs), combining higher-order neural network (HONN)-based estimation with elitist teaching–learning based optimization (ETLBO). Unlike conventional adaptive and neural estimation techniques that rely on multi-layer structures and heuristic tuning, the proposed approach exploits single-layer trainable HONNs, namely Pi–Sigma, Sigma–Pi, and Jordan Pi Sigma neural networks for simultaneous sensorless speed and motor parameter estimation, offering faster learning, improved fault tolerance, and enhanced approximation capability. A key novelty lies in the dual utilization of the non-parametric ETLBO algorithm, which optimally trains the HONN weights and biases while also tuning PI controller gains using the integral time square error (ITSE) criterion, thereby eliminating manual parameter selection and reducing computational burden. Comprehensive validation through statistical indices, dynamic response analysis, MATLAB/Simulink simulations, and d-SPACE Micro-lab box based experimental studies confirms that the ETLBO-optimized JPSNN achieves superior estimation accuracy, faster convergence, and robust dynamic performance across wide operating conditions. The proposed methodology delivers a computationally efficient, fully adaptive, and experimentally verified solution for high-performance sensorless IMD control.
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 7 (3) , 1089-1098
Power Quality Enhancement Using Dynamic Voltage Restorer With Echo State Network and Type-2 Fuzzy Logic Control
This research proposes an Echo-State Network (ESN) driven strategy to improve Power Quality (PQ) in utility grids through Dynamic Voltage Restorer (DVR) implementation. With the growing integration of nonlinear or critical loads, PQ degradation has become a pressing concern. The ESN-based algorithm efficiently estimates fundamental voltage quantities from a disturbed grid and supports PQ improvement. The proposed approach integrates an Echo State Network (ESN) for real-time estimation of fundamental voltage components and an adaptive Interval Type-2 Fuzzy Logic (IT2 FLC) controller for DC link voltage stabilization. This dynamic controller mitigates voltage stress and maintains a robust DC voltage level, crucial for generating the reference load voltage. The controller gains are optimized using the bio-inspired Gorilla Troops Algorithm (GTA), which enables a low computational burden and enhanced adaptability to grid disturbances. Additionally, it is noteworthy that the proposed technique reduces the values of settle and rise time (0.15s, 0.19s), overshoot and undershoot (3.28%, 3.56%), and recovery time to 0.421s. These statistics indicate that it outperforms the traditional SRF-PI and LSM-IT1 FLC strategies. The hybrid ESN and GTA IT2 FLC framework allows online gain tuning, ensuring sinusoidal load voltage and a significant reduction in total harmonic distortion from 12.19% to 2.74%. The proposed method delivers superior performance even in disturbed grid conditions, offering fast rise time, minimal overshoot, and less steady-state errors compared to conventional SRF-PI and LMS-Fuzzy Logic Controller (LMS-FLC). The findings obtained from a scaled-down prototype of DVR highlight the approach's effectiveness.
- 3 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 7 (3) , 1089-1098
Power Quality Enhancement Using Dynamic Voltage Restorer With Echo State Network and Type-2 Fuzzy Logic Control
This research proposes an Echo-State Network (ESN) driven strategy to improve Power Quality (PQ) in utility grids through Dynamic Voltage Restorer (DVR) implementation. With the growing integration of nonlinear or critical loads, PQ degradation has become a pressing concern. The ESN-based algorithm efficiently estimates fundamental voltage quantities from a disturbed grid and supports PQ improvement. The proposed approach integrates an Echo State Network (ESN) for real-time estimation of fundamental voltage components and an adaptive Interval Type-2 Fuzzy Logic (IT2 FLC) controller for DC link voltage stabilization. This dynamic controller mitigates voltage stress and maintains a robust DC voltage level, crucial for generating the reference load voltage. The controller gains are optimized using the bio-inspired Gorilla Troops Algorithm (GTA), which enables a low computational burden and enhanced adaptability to grid disturbances. Additionally, it is noteworthy that the proposed technique reduces the values of settle and rise time (0.15s, 0.19s), overshoot and undershoot (3.28%, 3.56%), and recovery time to 0.421s. These statistics indicate that it outperforms the traditional SRF-PI and LSM-IT1 FLC strategies. The hybrid ESN and GTA IT2 FLC framework allows online gain tuning, ensuring sinusoidal load voltage and a significant reduction in total harmonic distortion from 12.19% to 2.74%. The proposed method delivers superior performance even in disturbed grid conditions, offering fast rise time, minimal overshoot, and less steady-state errors compared to conventional SRF-PI and LMS-Fuzzy Logic Controller (LMS-FLC). The findings obtained from a scaled-down prototype of DVR highlight the approach's effectiveness.
- 26 July 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (11) , 14383-14405
Power quality improvement through UPQC-P using multiple-enhanced Lyapunov-demodulated quadrature signal generator
- 26 July 2025
- Published by Springer Nature in Electrical Engineering
- Vol. 107 (11) , 14383-14405
Power quality improvement through UPQC-P using multiple-enhanced Lyapunov-demodulated quadrature signal generator
- 20 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 8542-8554
Frequency Adaptive Enhanced Reduced-Order Generalized Integrator Control for Operation of DVR
This paper introduces a fundamental sequence component extractor using a frequency-adaptive enhanced reduced-order generalized integrator (FAEROGI)-based control scheme, developed to optimize the control of dynamic voltage restorer (DVR). The proposed control scheme reliably extracts fundamental positive sequence components (FPSCs) even under voltage distortion, offering advantages like a simple design with lower complexity, faster dynamic response, elimination of phase-lock or frequency-lock loops, and no need for low-pass filters. Traditional controllers, such as Proportional Integral (PI) controllers, have limited gain coefficients for optimal voltage regulation. This issue is addressed through the implementation of two distinct active disturbance rejection controllers (ADRCs) that regulate DC-link and load voltages, resulting in improved reference load voltage generation. To achieve optimal gain, ADRCs are tuned using the Cuckoo search optimization (CSO) algorithm, inspired by the Cuckoo bird’s adaptive foraging behavior. The CSO-optimized ADRC controller demonstrates superior performance, achieving minimal overshoot and faster settling times compared to a CSO-optimized PI controller. The FAEROGI control scheme is modeled and simulated in the MATLAB/Simulink environment, with performance evaluated under various grid voltage disturbances. Experimental results validated with a dSPACE board confirm the effectiveness and accuracy of the FAEROGI-based control technique.
- 20 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 8542-8554
Frequency Adaptive Enhanced Reduced-Order Generalized Integrator Control for Operation of DVR
This paper introduces a fundamental sequence component extractor using a frequency-adaptive enhanced reduced-order generalized integrator (FAEROGI)-based control scheme, developed to optimize the control of dynamic voltage restorer (DVR). The proposed control scheme reliably extracts fundamental positive sequence components (FPSCs) even under voltage distortion, offering advantages like a simple design with lower complexity, faster dynamic response, elimination of phase-lock or frequency-lock loops, and no need for low-pass filters. Traditional controllers, such as Proportional Integral (PI) controllers, have limited gain coefficients for optimal voltage regulation. This issue is addressed through the implementation of two distinct active disturbance rejection controllers (ADRCs) that regulate DC-link and load voltages, resulting in improved reference load voltage generation. To achieve optimal gain, ADRCs are tuned using the Cuckoo search optimization (CSO) algorithm, inspired by the Cuckoo bird’s adaptive foraging behavior. The CSO-optimized ADRC controller demonstrates superior performance, achieving minimal overshoot and faster settling times compared to a CSO-optimized PI controller. The FAEROGI control scheme is modeled and simulated in the MATLAB/Simulink environment, with performance evaluated under various grid voltage disturbances. Experimental results validated with a dSPACE board confirm the effectiveness and accuracy of the FAEROGI-based control technique.
- 20 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (5) , 6253-6262
Dynamic Voltage Restorer With Integration of Least Mean Square and Optimal Type-2 Fuzzy
The voltage disturbances are compensated by a series connected device called a Dynamic Voltage Restorer (DVR) in a grid supply system. Three phase DVR is operated with a proposed control based on Zero Attractive Least Mean Square (ZA-LMS) for compensation of the voltage Power Quality (PQ) concerns. The ZA-LMS uses a variable step size for weight updating under dynamics. Secondly, the DC and AC-link is associated with a severe voltage fluctuation and it affects the performance of DVR. To address this issue, an Interval Type-2 Fuzzy Controller (IT2 FC) is developed and compared with a classical Type-1 Fuzzy Logic Controller (T1 FLC). An Osprey Inspired Optimizer (ISO) is utilized to achieve the optimum values of variables for T1 FLC and IT2 FC to accelerate the system response, save time and more accuracy is achieved. The parameters of antecedent and consequent are optimized by ISO method and observed that under transitory scenario IT2 FC outperforms the T1 FLC with an improved response of Settle time (ts3), Overshoot (Os3), and Undershoot (Us3) of 0.121s, 2.2%, and 5.6% as per Table-1. This shows that the IT2 FC yields potential results compared to conventional T1FC controllers under a dynamic. For validating the developed control schemes simulation and experimentation results are demonstrated to show the efficacy of ZA-LMS integrated with IT2 FC under different grid conditions.
- 20 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (5) , 6253-6262
Dynamic Voltage Restorer With Integration of Least Mean Square and Optimal Type-2 Fuzzy
The voltage disturbances are compensated by a series connected device called a Dynamic Voltage Restorer (DVR) in a grid supply system. Three phase DVR is operated with a proposed control based on Zero Attractive Least Mean Square (ZA-LMS) for compensation of the voltage Power Quality (PQ) concerns. The ZA-LMS uses a variable step size for weight updating under dynamics. Secondly, the DC and AC-link is associated with a severe voltage fluctuation and it affects the performance of DVR. To address this issue, an Interval Type-2 Fuzzy Controller (IT2 FC) is developed and compared with a classical Type-1 Fuzzy Logic Controller (T1 FLC). An Osprey Inspired Optimizer (ISO) is utilized to achieve the optimum values of variables for T1 FLC and IT2 FC to accelerate the system response, save time and more accuracy is achieved. The parameters of antecedent and consequent are optimized by ISO method and observed that under transitory scenario IT2 FC outperforms the T1 FLC with an improved response of Settle time (ts3), Overshoot (Os3), and Undershoot (Us3) of 0.121s, 2.2%, and 5.6% as per Table-1. This shows that the IT2 FC yields potential results compared to conventional T1FC controllers under a dynamic. For validating the developed control schemes simulation and experimentation results are demonstrated to show the efficacy of ZA-LMS integrated with IT2 FC under different grid conditions.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Adaptive Parameter Measurement in Sensorless Speed Control of Induction Motor for Vehicle Loads
A self-constructing intelligence training-based Adaptive Neuro-fuzzy inference system (ANFIS) is employed to measure parameters of adaptive sensorless indirect field orientation control induction motor drive (IFOC-IMD). To intensify IMD functional performance indices, the fuzzy-neural hybridization control strategy of evolving-Takagi–Sugeno–Kang (e-TSK) is employed to measure instantaneous parameters. To avoid slow convergence, local minima, and provide a derivative-free solution, a nature-inspired metaheuristic Biogeography-Based Optimization (BBO) is integrated into eTSK-ANFIS training. It plays an important role in designing the optimal rules and appropriate selection of membership functions. The statistical performance measurement metrics are adopted to evaluate model performance during training and testing. An objective function (MSE) of a predictive model is reported as 0.004618 in training and 0.004885 in the testing phase. This will ensure the ANFIS estimator drastically enhances the measurement of parameters and consistently mimics reference speed. The BBO algorithm is also implemented to obtain the optimized fractional-order proportional integral (FOPI) gains of speed and current controllers for the generation of reference signals with minimized error. It provides the lower value of maximum peak overshot and settling time. The Performance results confirm that the proposed measurement-based adaptive control strategy ensures satisfactory robustness with accurate measurement and stable operation of the system under dynamics.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Adaptive Parameter Measurement in Sensorless Speed Control of Induction Motor for Vehicle Loads
A self-constructing intelligence training-based Adaptive Neuro-fuzzy inference system (ANFIS) is employed to measure parameters of adaptive sensorless indirect field orientation control induction motor drive (IFOC-IMD). To intensify IMD functional performance indices, the fuzzy-neural hybridization control strategy of evolving-Takagi–Sugeno–Kang (e-TSK) is employed to measure instantaneous parameters. To avoid slow convergence, local minima, and provide a derivative-free solution, a nature-inspired metaheuristic Biogeography-Based Optimization (BBO) is integrated into eTSK-ANFIS training. It plays an important role in designing the optimal rules and appropriate selection of membership functions. The statistical performance measurement metrics are adopted to evaluate model performance during training and testing. An objective function (MSE) of a predictive model is reported as 0.004618 in training and 0.004885 in the testing phase. This will ensure the ANFIS estimator drastically enhances the measurement of parameters and consistently mimics reference speed. The BBO algorithm is also implemented to obtain the optimized fractional-order proportional integral (FOPI) gains of speed and current controllers for the generation of reference signals with minimized error. It provides the lower value of maximum peak overshot and settling time. The Performance results confirm that the proposed measurement-based adaptive control strategy ensures satisfactory robustness with accurate measurement and stable operation of the system under dynamics.
- 26 February 2025
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 46 (1)
Linear Kalman filter frequency-locked loop algorithm for control of dynamic voltage restorer
- 26 February 2025
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 46 (1)
Linear Kalman filter frequency-locked loop algorithm for control of dynamic voltage restorer