Ryu Kato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ryu Kato has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Yokoi
The University of Electro-Communications
21 shared publicationsTamio Arai
Dept. of Precision Eng., Univ. of Tokyo, Tokyo, Japan
21 shared publicationsFeng Duan
Dept. of Autom., Nankai Univ., Tianjin, China
9 shared publicationsJeffrey Too Chuan Tan
9 shared publications- Tamio Arai
The University of Tokyo
9 shared publications - Hiroshi Yokoi
University of Tokyo
8 shared publications
Latest Publications
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 4623-4626
Development of Hand-Assistance Device using Hand-Joint Orthosis and Neuromuscular Electrical Stimulation
The development of self-help devices has attracted attention in the light of improving the activities of daily living (ADL) in patients with finger paralysis. These devices are required to reduce discomfort and enable greater degrees of grasping motions in patients. In this study, we developed a lightweight self-help device that uses neuromuscular electrical stimulation and hand-joint orthosis to finely control the fingers. In addition, we examined the possible grasping actions by testing how well the users of this device exhibited improvements in their ADL. Our results indicate that our self-help device can potentially be adapted to address finger paralysis.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
- Vol. 2021, 4623-4626
Development of Hand-Assistance Device using Hand-Joint Orthosis and Neuromuscular Electrical Stimulation
The development of self-help devices has attracted attention in the light of improving the activities of daily living (ADL) in patients with finger paralysis. These devices are required to reduce discomfort and enable greater degrees of grasping motions in patients. In this study, we developed a lightweight self-help device that uses neuromuscular electrical stimulation and hand-joint orthosis to finely control the fingers. In addition, we examined the possible grasping actions by testing how well the users of this device exhibited improvements in their ADL. Our results indicate that our self-help device can potentially be adapted to address finger paralysis.
- Open Access
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 13 (2) , 17-00596
Estimating wrist joint angle with limited skin deformation information
Ascertaining a person's motion intentions through muscle activity is important for controlling various assistive devices for people with disabilities. Several techniques have been proposed for estimating the extent of intended joint angle motion using skin deformation information derived from muscle contractions. The objective of this study is to verify our signal processing procedure for estimating intended wrist joint angle with skin deformation information in able-bodied subjects and subjects with an upper-limb amputation. Skin deformation was measured with a tactile sensor consisting of 48 distance sensors over a large measurement area. The root-mean-square error (RMSE) of the measured and estimated angles are evaluated offline using multiple linear regression in one individual with an upper-limb amputation and five able-bodied participants. In all tests, subjects undertook a wrist flexion and extension task guided by visual feedback, measured in real time. Sensors are selected in descending order of the standard deviation of each sensor's value. Strong relationships occur between the position and displacement of the area of greatest skin deformation and the intended wrist joint angle in all subjects. The minimum RMSE was 8.19° for the individual with an upper-limb amputation using 48 sensors as input, and 2.24° for able-bodied individuals using 16 sensors. One-way repeated-measures analysis of variance showed that at least 16 sensors are needed to reliably record skin deformation. Skin deformation analyzed with multiple linear regression is a plausible means of estimating intended wrist joint angle in persons with an upper-limb amputation. Even when a limited number of sensors (≥16) are used, continuous joint angle can be estimated reliably. These findings will inform the design of assistive devices that must noninvasively determine muscle activity.
- 1 January 2018
- Published by Japan Society of Mechanical Engineers in Journal of Biomechanical Science and Engineering
- Vol. 13 (2) , 17-00596
Open AccessEstimating wrist joint angle with limited skin deformation information
Ascertaining a person's motion intentions through muscle activity is important for controlling various assistive devices for people with disabilities. Several techniques have been proposed for estimating the extent of intended joint angle motion using skin deformation information derived from muscle contractions. The objective of this study is to verify our signal processing procedure for estimating intended wrist joint angle with skin deformation information in able-bodied subjects and subjects with an upper-limb amputation. Skin deformation was measured with a tactile sensor consisting of 48 distance sensors over a large measurement area. The root-mean-square error (RMSE) of the measured and estimated angles are evaluated offline using multiple linear regression in one individual with an upper-limb amputation and five able-bodied participants. In all tests, subjects undertook a wrist flexion and extension task guided by visual feedback, measured in real time. Sensors are selected in descending order of the standard deviation of each sensor's value. Strong relationships occur between the position and displacement of the area of greatest skin deformation and the intended wrist joint angle in all subjects. The minimum RMSE was 8.19° for the individual with an upper-limb amputation using 48 sensors as input, and 2.24° for able-bodied individuals using 16 sensors. One-way repeated-measures analysis of variance showed that at least 16 sensors are needed to reliably record skin deformation. Skin deformation analyzed with multiple linear regression is a plausible means of estimating intended wrist joint angle in persons with an upper-limb amputation. Even when a limited number of sensors (≥16) are used, continuous joint angle can be estimated reliably. These findings will inform the design of assistive devices that must noninvasively determine muscle activity.
- 11 February 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 269-282
Development of New Cosmetic Gloves for Myoelectric Prosthetic Hand by Using Thermoplastic Styrene Elastomer
- 11 February 2017
- Published by Springer Nature in Advances in Intelligent Systems and Computing
- p. 269-282
Development of New Cosmetic Gloves for Myoelectric Prosthetic Hand by Using Thermoplastic Styrene Elastomer
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2016, 5124-5127
Development of five-finger robotic hand using master-slave control for hand-assisted laparoscopic surgery
This study aims to develop a robotic hand as a substitute for a surgeon's hand in hand-assisted laparoscopic surgery (HALS). We determined the requirements for the proposed hand from a surgeon's motions in HALS. We identified four basic behaviors: “power grasp,” “precision grasp,” “open hand for exclusion,” and “peace sign for extending peritoneum.” The proposed hand had the minimum necessary DOFs for performing these behaviors, five fingers as in a human's hand, a palm that can be folded when a surgeon inserts the hand into the abdomen, and an arm for adjusting the hand's position. We evaluated the proposed hand based on a performance test and a physician's opinions, and we confirmed that it can grasp organs.
- 18 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2016, 5124-5127
Development of five-finger robotic hand using master-slave control for hand-assisted laparoscopic surgery
This study aims to develop a robotic hand as a substitute for a surgeon's hand in hand-assisted laparoscopic surgery (HALS). We determined the requirements for the proposed hand from a surgeon's motions in HALS. We identified four basic behaviors: “power grasp,” “precision grasp,” “open hand for exclusion,” and “peace sign for extending peritoneum.” The proposed hand had the minimum necessary DOFs for performing these behaviors, five fingers as in a human's hand, a palm that can be folded when a surgeon inserts the hand into the abdomen, and an arm for adjusting the hand's position. We evaluated the proposed hand based on a performance test and a physician's opinions, and we confirmed that it can grasp organs.
- 1 January 2014
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 80 (3) , 259-264
Five-fingered Myoelectric Hand for Realizing a Precise Human-hand Function
- 1 January 2014
- Published by Japan Society for Precision Engineering in Journal of the Japan Society for Precision Engineering
- Vol. 80 (3) , 259-264
Five-fingered Myoelectric Hand for Realizing a Precise Human-hand Function
- 1 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 2054-2059
Development of five-finger multi-DoF myoelectric hands with a power allocation mechanism
For use as five-finger myoelectric hands in daily living, robotic hands must be 1) lightweight and human sized as well as possess 2) human-like multiple degrees of freedom (DoF) and a high grip force. The compatibility of these requirements is a trade-off; ideal robotic hands have yet to sufficiently satisfy both these requirements. Herein a power allocation mechanism is proposed to improve the grip force without increasing the size or weight of robotic hands using redundant DoF during pinching motions. Additionally, this mechanism is applied to an actual five-finger myoelectric hand, which can make seven types of motions that are necessary for activities of daily living (ADL) and realizes about a 60% improvement in fingertip force, allowing three fingers to pinch objects exceeding 1 kg.
- 1 May 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 2054-2059
Development of five-finger multi-DoF myoelectric hands with a power allocation mechanism
For use as five-finger myoelectric hands in daily living, robotic hands must be 1) lightweight and human sized as well as possess 2) human-like multiple degrees of freedom (DoF) and a high grip force. The compatibility of these requirements is a trade-off; ideal robotic hands have yet to sufficiently satisfy both these requirements. Herein a power allocation mechanism is proposed to improve the grip force without increasing the size or weight of robotic hands using redundant DoF during pinching motions. Additionally, this mechanism is applied to an actual five-finger myoelectric hand, which can make seven types of motions that are necessary for activities of daily living (ADL) and realizes about a 60% improvement in fingertip force, allowing three fingers to pinch objects exceeding 1 kg.
- 7 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 10 (2) , 465-470
An Assembly-Skill-Transferring Method for Cellular Manufacturing System—Part I: Verification of the Proposed Method for Motor Skill
Although a cellular manufacturing system can produce diversified products flexibly, its assembly efficiency is mainly limited by the operators' assembly performance. To improve the operators' assembly performance without longtime training, an assembly-skill-transferring method was proposed to realize the assembly skill transfer process from skilled operators to novice operators. In the cellular manufacturing system, the assembly skills consist of cognition skills and motor skills. Taking a “Peg-in-Hole Task” as an example, the effect of the proposed assembly transfer method was verified for motor skills. The results show that the proposed assembly-skill-transferring system can improve the novice operators' assembly performance greatly.
- 7 March 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Automation Science and Engineering
- Vol. 10 (2) , 465-470
An Assembly-Skill-Transferring Method for Cellular Manufacturing System—Part I: Verification of the Proposed Method for Motor Skill
Although a cellular manufacturing system can produce diversified products flexibly, its assembly efficiency is mainly limited by the operators' assembly performance. To improve the operators' assembly performance without longtime training, an assembly-skill-transferring method was proposed to realize the assembly skill transfer process from skilled operators to novice operators. In the cellular manufacturing system, the assembly skills consist of cognition skills and motor skills. Taking a “Peg-in-Hole Task” as an example, the effect of the proposed assembly transfer method was verified for motor skills. The results show that the proposed assembly-skill-transferring system can improve the novice operators' assembly performance greatly.
- 5 February 2013
- Published by IGI Global Scientific Publishing
- p. 412-427
Multi-Modal Assembly-Support System for Cellular Manufacturing
Cellular manufacturing meets the diversified production and quantity requirements flexibly. However, its efficiency mainly depends on the operators’ working performance. In order to improve its efficiency, an effective assembly-support system should be developed to assist operators during the assembly process. In this chapter, a multi-modal assembly-support system (MASS) was proposed, which aims to support operators from both information and physical aspects. To protect operators in MASS system, five main safety designs as both hardware and control levels were also discussed. With the information and physical support from the MASS system, the assembly complexity and burden to the assembly operators are reduced. To evaluate the effect of MASS, a group of operators were required to execute a cable harness task. From the experimental results, it can be concluded that by using this system, the operators’ assembly performance is improved and their mental work load is reduced. Consequently the efficiency of the cellular manufacturing is improved.
- 5 February 2013
- Published by IGI Global Scientific Publishing
- p. 412-427
Multi-Modal Assembly-Support System for Cellular Manufacturing
Cellular manufacturing meets the diversified production and quantity requirements flexibly. However, its efficiency mainly depends on the operators’ working performance. In order to improve its efficiency, an effective assembly-support system should be developed to assist operators during the assembly process. In this chapter, a multi-modal assembly-support system (MASS) was proposed, which aims to support operators from both information and physical aspects. To protect operators in MASS system, five main safety designs as both hardware and control levels were also discussed. With the information and physical support from the MASS system, the assembly complexity and burden to the assembly operators are reduced. To evaluate the effect of MASS, a group of operators were required to execute a cable harness task. From the experimental results, it can be concluded that by using this system, the operators’ assembly performance is improved and their mental work load is reduced. Consequently the efficiency of the cellular manufacturing is improved.
- Open Access
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2013, _J151024-1
J151024 Decision technique of the most suitable placement of the stimulation electrode for limbs control using surface electrical stimulation : Design of a pulse select circuit selecting the most suitable electrodes from many electrodes
Precise motor point stimulation is needed for efficient functional electrical stimulation (FES) because the stimulation of the motor point makes the muscle to contract the most. However physical therapists have difficulties of determining the position of motor point, because the position of motor point is different about 20% of muscle length among individuals. Therefore the purpose of this paper is to develop the automated FES electrodes positioning system which can stimulate the motor point precisely. This research deals with this purpose by developing the pulse select circuit, which can allocate FES stimuli to the multiple arbitrary electrodes. Therefore this circuit can search the most efficient pattern of electrodes positions by selecting stimulating electrodes in various patterns. Thus developed circuit can change position and area of stimulation at once: a wide variety of muscles are applicable. Moreover, developed circuit can be applied to other bio-instrumentation system which searches the best stimulation position. The developed pulse select circuit consists of a microcomputer, demultiplexers and photo-MOS relays, and it can select one arbitrary FES output line out of four output lines, and assign the selected output line to multiple arbitrary electrodes.
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2013, _J151024-1
Open AccessJ151024 Decision technique of the most suitable placement of the stimulation electrode for limbs control using surface electrical stimulation : Design of a pulse select circuit selecting the most suitable electrodes from many electrodes
Precise motor point stimulation is needed for efficient functional electrical stimulation (FES) because the stimulation of the motor point makes the muscle to contract the most. However physical therapists have difficulties of determining the position of motor point, because the position of motor point is different about 20% of muscle length among individuals. Therefore the purpose of this paper is to develop the automated FES electrodes positioning system which can stimulate the motor point precisely. This research deals with this purpose by developing the pulse select circuit, which can allocate FES stimuli to the multiple arbitrary electrodes. Therefore this circuit can search the most efficient pattern of electrodes positions by selecting stimulating electrodes in various patterns. Thus developed circuit can change position and area of stimulation at once: a wide variety of muscles are applicable. Moreover, developed circuit can be applied to other bio-instrumentation system which searches the best stimulation position. The developed pulse select circuit consists of a microcomputer, demultiplexers and photo-MOS relays, and it can select one arbitrary FES output line out of four output lines, and assign the selected output line to multiple arbitrary electrodes.
- 1 January 2013
- Published by The Robotics Society of Japan in Journal of the Robotics Society of Japan
- Vol. 31 (1) , 51-59
Discrimination Analysis and Movement Decision of the Prosthetic Arm by Using Monkey ECoGs Data Associated with Self-feeding Motions
- 1 January 2013
- Published by The Robotics Society of Japan in Journal of the Robotics Society of Japan
- Vol. 31 (1) , 51-59
Discrimination Analysis and Movement Decision of the Prosthetic Arm by Using Monkey ECoGs Data Associated with Self-feeding Motions